MEMORY HiCORDER MR8827

MEMORY HiCORDER MR8827
MEMORY HiCORDER MR8827
64
32 analog channels +
ch 32 logic channels
High-speed
Isolated testing
The Memory HiCorder MR8827 achieves isolated input between the main unit
and channel or between channels, at a maximum sampling speed of 20 MS/s
on all channels.
It provides mixed recording that combines 32 analog channels and 32 logic
channels, and logic input can be expanded up to 64 channels.
Welcome to the next generation of Hioki Memory HiCorders that deliver multichannel waveform recording of a diverse array of signals to meet complex and
demanding applications.
* When using 64 logic channels, 28 analog channels are available.
2
MR8827 - Evolving to the Next Stage of High-Speed
Waveform Recording
The high-performance 8826 delivered the most analog channels out of all portable-type
Memory HiCorders. The new MEMORY HiCORDER MR8827 inherits that concept and evolves
even further.
2x Logic Input Channels
20x Sampling Speed
1MS/s
20MS/s
32ch
64ch
A maximum of 8 logic probes can
be inserted in the main unit. Use of
2 Logic Unit 8973 will add 8 more
connections, supporting 64 channel
The sampling speed (for all channels
A/D converter integrated
in the input amp
logic signal input. (This reduces the
simultaneously) increased by 20
times, while maintaining isolated
input.
8x Internal Memory Capacity
64MW
512MW
number of available analog channels
Logic Unit 8973
to 28.)
Storage Devices and Media
USB Memory/CF Card
SSD (Solid State Drive)
With 8 times more internal memory
Use various storage devices and
capacity from 64 MW to 512 MW,
media with more capacity and faster
you can now record signals of fast
writing speeds than conventional
events easily and for extended pe-
drives or PC cards. The optional
riods of time.
internal SSD has 128 GB of capacity
so you can store large amounts of
data.
LCD Resolution
3x PC Transfer Speed
3 times faster
transfer speed!
Transferring speed of stored data
from internal memory or SSD to the
PC has greatly increased.
Conventional transfer time
10.4 inch TFT 10.4 inch SVGA
640×480
800×600
Overlapping waveforms are easier
to identify now with a new high
resolution LCD.
Data transfer time →
Easy Setup of Recording Paper
2x Paper Feeding Speed
25mm/sec
50mm/sec
Use of a high-speed thermal printer
gives you 2 times the printing
speed.
No more hassles of feeding
re c o rding pa p e r b et we e n t h e
rubber roller and the thermal head.
Just drop it in to set it up.
3
A4 Size Printer
Print in fine detail, with 2
times the paper feeding
speed. Get a printout of
enlarged waveforms on
A4 size paper so you can
check them easily on-site.
Sampling Speed and Recording Time
Scalable Input Channels
Memory functions
A maximum of 16 modules can
be connected on the rear side.
The main unit also has
connectors for connecting 8
logic probes.
Maximum recording length
Time axis
range/div
Samplingspeed
50 ns
100 ns
20 µs
50 µs
from typical oscilloscopes by
providing complete isolation for
the input of each channel, and
between each channel and
the main frame, enabling you
to handle electrical potential
Isolation element
differences among multiple
signals without any concern.
High Resolution LCD
Scroll
0.8 s
1.6 s
200 ns
500 ns
100 µs
200 µs
The MR8827 differentiates itself
32 channels
160,000 div
5 µs
10 µs
Isolated Input for Security
Recorder functions
1 µs
2 µs
500 µs
1 ms
2 ms
5 µs
10 µs
20 µs
10 ms
20 ms
50 ms
100 µs
200 µs
500 µs
5 ms
50 µs
3.2 s
8s
16 s
32 s
1 min 20 s
2 min 40 s
5 min 20 s
13 min 20 s
26 min 40 s
53 min 20 s
2 h 13 min 20 s
200 ms
500 ms
1s
2s
5s
10 s
100 ms
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
8 h 53 min 20 s
22 h 13 min 20 s
1 d 20 h 26 min 40 s
3 d 16 h 53 min 20 s
9 d 6 h 13 min 20 s
18 d 12 h 26 min 40 s
30 s
300 ms
55 d 13 h 20 min 0 s
50 s
1 min
100 s
2 min
500 ms
600 ms
1s
1.2 s
92 d 14 h 13 min 20 s
111 d 2 h 40 min 0 s
185 d 4 h 26 min 40 s
222 d 5 h 20 min 0 s
5 min
3s
Scroll
4 h 26 min 40 s
Scanning
Expand / shrink
Conventional devices used a 640×480 dot TFT LCD,
but the next-generation MR8827 uses an 800×600 dot
SVGA high resolution LCD to make it even easier to
identify overlapping measured waveforms.
1s
2s
5s
22 h 13 min 20 s
1 d 20 h 26 min 40 s
4 d 15 h 6 min 40 s
30 s
50 s
1 min
27 d 18 h 40 min 0 s
46 d 7 h 6 min 40 s
55 d 13 h 20 min 0 s
10 s
100 s
2 min
5 min
10 min
30 min
1h
9 d 6 h 13 min 20 s
92 d 14 h 13 min 20 s
111 d 2 h 40 min 0 s
277 d 18 h 40 min 0 s
- abbreviated - abbreviated - abbreviated -
Sampling period:
1 µs, 10 µs, 1 ms, 10 ms, 100 ms
*Select within 1/100 of the time axis.
Also limited by combination with the
time axis setting for memory recording.
Scanning
as binary or CSV data.
screen to check the expanded
form.
4 h 26 min 40 s
11 h 6 min 40 s
Specify the segment to save
cal axis, you can also split the
waveform of the shrunk wave-
1 h 6 min 40 s
2 h 13 min 20 s
Cutout
shrink the time axis or verti-
+ −
200 ms
500 ms
13 min 20 s
26 min 40 s
the waveform's cross point.
Not only can you expand or
Expand/Shrink
50 ms
100 ms
80,000 div
Scan data at the cursor and
check all or just part of it.
Expanded
waveform
10 ms
20 ms
Maximum recording length
- abbreviated -
Scroll through the waveform to
Shrunk
waveform
Time axis
range/div
Cutout
4
Signal Input and Output
The right module for your measurement needs
Inverter / UPS Test
Operation testing and evaluation during load
fluctuation
● Confirmation of UPS switching
●
ANALOG UNIT 8966
Recommended
LOGIC UNIT 8973
units
CURRENT UNIT 8971
Perfect for inverter and UPS evaluation / start-up tests.
Record using both logic (control signals) and analog
(primary/secondary voltage or current for a UPS or
inverter).
UPS
Inverter
Power Monitor and Logger
Torque
sensor
Identify power fluctuations when power supply is
turned ON/OFF and during load fluctuations
● Long-term fluctuations in power
●
Inverter
ANALOG UNIT 8966
Recommended
Load
Motor
Battery
HIGH RESOLUTION UNIT 8968
units
Pulse
Encoder
FREQ UNIT 8970
Load the analog output for the rms (instant power
/ voltage / current, etc.) calculated by the power
analyzer, or import the waveform output from the power
analyzer to observe data for long-term tests or irregular
waveforms.
D/A output
Power Analyzer (PW6001)
Control Simulation
Generate simulated output of each type of sensor
signal
● Fluctuating simulated output for 12 V DC car batteries
●
ARBITRARY WAVEFORM GENERATOR UNIT U8793
Recommended
WAVEFORM GENERATOR UNIT MR8490
units
PULSE GENERATOR UNIT MR8791
Use actual waveforms to perform testing on control
boards, such as for engine control, airbags, brake
systems, power steering, and active suspension. This
allows efficient simulation of actual waveforms obtained
from cars.
Generation
13 units
to choose
from
Voltage
ARBITRARY WAVEFORM HIGH VOLTAGE UNIT
GENERATOR UNIT
U8974
U8793
NEW
No. of channels: 2
Arbitrary waveform output
●
●
Output frequency range
10m Hz to 100 kHz
Max. output: 15 V
NEW
Measurement resolution: 16-bit
1/1600 of measurement range
High voltage
Commercial power supply
(primary/secondary)
●
Power equipment characteristics testing
Perfect for control testing of automobiles, high speed trains, and traditional trains
DC voltage
DIGITAL VOLTMETER
UNIT
MR8990
Generation
WAVEFORM
GENERATOR UNIT
MR8790
NEW
Measurement resolution: 24-bit No. of channels: 4
1/50 000 of measurement range Waveform output
●
●
●
●
●
Multi-channel
Minute sensor voltage
EV battery voltage
●
●
DC output: -10 V to 10 V
Sine wave output
10 mHz to 20 kHz
Pulse
PULSE GENERATOR
UNIT
MR8791
NEW
No. of channels: 8
Pulse output
●
●
Pulse output
0.1 Hz to 20 kHz
Pattern output
Voltage
ANALOG UNIT
8966
Measurement resolution: 12-bit
20 MS/s high-speed sampling
Various amps
Transducers
Sensors
●
Industrial meters
●
●
●
5
4 new modules added
NEW
Hioki has added new high-performance
NEW ARBITRARY WAVEFORM GENERATOR UNIT U8793 ►
modules in response to overwhelming
NEW HIGH VOLTAGE UNIT U8974 ►
demand.
The Memory HiCorder now supports
NEW WAVEFORM GENERATOR UNIT MR8790 ►
NEW PULSE GENERATOR UNIT MR8791 ►
a wide variety of measurements with a
total of 13 plug-in modules.
DIGITAL VOLTMETER UNIT MR8990 ►
Output and record results seamlessly
Just one MEMORY HiCORDER gives
y o u a f u n c t i o n g e n e ra to r m o d e,
arbitrary waveform generator mode,
and waveform measurement mode.
This makes it easy to obser ve
waveforms while varying test
conditions, such as changing the
signal's amplitude and frequency and
programming various waveforms to
output in order.
Generate
Record
Standalone testing
Output recorded waveforms
without modification
For example, you could output actual waveforms recorded
from a car without modification, and then use them for
standalone testing. You can also generate isolated output
of up to 15 V without a generator or amplifier, which is
traditionally necessary in order to generate output while
varying the signal's amplitude and frequency.
Max. 15 V output
Measurement
on actual car
Standalone
testing
Waveform Maker SF8000
for processing
as needed
Process actual waveforms for
reproducibility testing
Process and calculate signals recorded with the
M E M O R Y H i C O R D E R a n d o u t p u t t h e a r bi t ra r y
waveforms that you create.
Reproducibility testing
Output waveform example
Waveform Maker Software included
Sine wave
After you install the included SF8000 Waveform Maker
software on your computer, you can create waveforms
easily by either entering them directly or by entering the
functions behind them. You can also quickly add noise
and multiply waveforms.
Triangular
wave
Square
wave
Pulse wave
Ramp up
wave
Ramp down
wave
Sweep
output
Program
output
Program and generate connected waveforms
1000 V DC, 700 V AC high-voltage direct input
S inc e yo u c a n dire ctly inpu t up to
1000 V DC and 700 V AC, a differential
probe is no longer necessary.
Maximum rated voltage to ground is
1000 V for CAT III and 600 V for CAT IV
environments.
Battery
Load
Inverter
Motor
No differential probe needed
Direct voltage measurement
Temperature
Voltage
Distortion
Frequency, RPM
Current
Voltage
TEMP UNIT
8967
HIGH RESOLUTION
UNIT
8968
STRAIN UNIT
8969
FREQ UNIT
8970
CURRENT UNIT
8971
Measurement resolution: 16-bit
1/1000 of measurement range
Measurement resolution: 16-bit
1/1600 of measurement range
Measurement resolution: 16-bit
1/1250 of measurement range
Measurement resolution: 16-bit
1/2000 of measurement range
Measurement resolution: 12-bit Measurement resolution: 12-bit
Clamp sensor direct connection RMS measurement
●
Thermocouple
K, J, E, T, N, R, S, B, W
Supply voltage
Primary / secondary inverter
voltage
●
Motor voltage, etc.
Strain gauge converter
Dynamic strain ● Vibration
Pressure ● Acceleration
●
Weight, etc.
●
●
●
●
●
●
●
Encoder
Rotating pulse
●
●
●
Supply current
Inverter current
Motor current, etc.
DC/RMS UNIT
8972
Supply voltage
Primary / secondary inverter
voltage
●
Motor voltage, etc.
●
●
Contact
LOGIC UNIT
8973
No. of channels: 16
Observation of control signal
Voltage / non-voltage
contacts
Relay signals
●
AC / DC signals
●
●
6
Data Storage
Save on devices
and media
Input signals af ter A / D conversion
stored in internal memory can be saved
SSD
Input
Input
Transfer
on the optional internal SDD, USB mem-
CF card
ory, or CF card.
USB Memory stick
A/D conversion
Transfer to PC
Save on devices and media
Store in internal memory
LAN Connection
USB Connection
Check and analyze data saved in the
Use the H T T P function to operate
Use a PC to retrieve data saved on
internal SSD, USB memory, or CF card,
MR8 827 with a browser on a PC
devices and media such as internal
by transferring it to a PC, via LAN or
connected via LAN. You can also use
memory, SSD, or CF card connected to
USB.
the FTP function to retrieve data from
the main unit, via USB.
internal memor y, devices or media
connected to the main unit.
LAN
FTP
HTTP
USB
Data Analyze
WAVE PROCESSOR 9335
LAN COMMUNICATOR 9333
(Software sold separately)
(Software sold separately)
● Waveform display,
calculations
● Print function
● Auto-save waveform data to PC
● Remote control via LAN connection
● Save in CSV format and transfer to spreadsheet programs
■ 9335 Brief Specifications
■ 9333 Brief Specifications
Operating
Windows 10/8/7 (32/64-bit), Vista (32-bit), XP
environment
Operating
Windows 10/8/7 (32/64-bit), Vista (32-bit), XP, (9333 ver.1.09 or later)
environment
Functions
- Display functions: Waveform display, X-Y display, Cursor function, etc.
- File loading: Readable data formats (.MEM, .REC, .RMS, .POW) /
Maximum loadable file size: Maximum file size that can be saved by a
given device (file size may be limited depending on the computer configuration)
- Data conversion: Conversion to CSV format, Batch conversion of multiple files, etc.
Printing
- Print function: Printing image file output (expanded META type, ".EMF")
- Print formatting: 1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up, preview,
hard copy
Functions
- Auto-saves waveform data to PC, Remote control of Memory HiCorder
(by sending key codes and receiving images on screen), print report,
print images from the screen, receive waveform data in same format as
waveform files from the Memory HiCorder (binary only)
- Waveform data acquisition: Accept auto-saves from the Memory
HiCorder, same format as auto-save files of Memory HiCorder (binary
only), print automatically with a Memory HiCorder from a PC. The
Memory HiCorder’s print key launches printouts on the PC
- Waveform viewer: Simple display of waveform files, conversion to CSV
format, etc.
7
MEMORY HiCORDER MR8827
A4 size thermal
printer
10.4 inch SVGA waveform monitor
CF card slot
USB 2.0
Rack handle
USB 2.0
(connect to the PC)
LAN
External control connector
Input module slots
(maximum 16 modules)
iPad App for Memory HiCorder HMR Terminal
Free app (exclusively for iPad) downloadable from the App Store
● Freely control waveforms using iPad's gesture
controls
● Fingertip operation of Max. 32 channels of
waveform data
● Operate the Memory HiCorder via network
You can change settings, and monitor
waveforms during measurement.
Logic probe connectors
(for 8 units)
Wave Viewer Wv
(Bundled software)
● Check waveforms with
binary data on a PC
● Save data in CSV
format and transfer to
spreadsheet programs
*New function on Ver 2.0
■ HMR Terminal Brief specifications (free software)
Operating
iOS on the iPad (Apple Inc. )
environment
Functions
- Data acquisition: Send to iPad via FTP using a WiFi router, or load to
iPad via iTunes (PC app)
- Intuitively operate waveform level searches, maximum / minimum /
average values, zero position adjustment, and more at your fingertips
- Waveform monitoring
- Meter setting
* Logic waveforms and computational waveforms are not supported.
■ Wave Viewer (Wv) Brief Specifications
Operating
Windows 10/8/7 (32/64-bit), Vista (32-bit), XP
environment
Functions
- Simple display of waveform files
- Convert binary data files to text format, CSV, etc.
- Scroll function, enlarge/reduce display, jump to cursor/trigger position, etc.
8
Application
Ptionerfect
for recording a combinaof analog and logic signals that
require multiple channels.
Electric power
Power electronics
Transformer Interruption Tests
Interchannel isolation allows for safe circuit connections.
Simultaneous high-speed sampling can record waveforms
before and after the interruption, and allows you to input
many control and circuit signals.
Battery Charge/Discharge
Tests
Input and test the voltage of each battery cell. The MR8827
is built for up to 400 V DC input, protecting it even if high
voltage is applied when there is a short-circuit.
Inverter / UPS Test
Perfect for inverter and UPS evaluation and start-up tests.
Record using both logic (control signals) and analog input
(primary/secondary voltage or current for a UPS or inverter).
Power Monitor and Logger
INV
By loading the analog output for the effective value (instant
Power
power / voltage / current, etc.) calculated by the power
analyzer, or by importing the waveform output from the
power analyzer to MR8827, you can observe data for longterm tests or irregular waveforms.
Motor
Load
Power
POWER ANALYZER
MR8827
Torque
Meter
D/A output PW6001 or other
Torque / Rotation
9
Rsignals
ecord a diverse array of
simultaneously
Mechatronics
Automotive
ECU Evaluation
The 32 analog channels and 32 logic channels work great for
IN
OUT
observing input and output signals of an Engine Control Unit.
Over 4 hours of recording can be achieved with 1 ms sampling.
Engine Strain Measurements
Use the Strain Unit 8969 to perform strain measurements
of up to 32 channels. You can use the numerical value
calculation function to automatically calculate the maximum
value, minimum value, and P-P value of strain waveforms.
Vibration / Endurance Tests
Use the long 512 M W memor y to obser ve vibration
waveforms easily (Memor y function). Also, with the
recorder function, you can perform long-term observation
by capturing the waveform peaks while sampling at high
speeds.
Injection Molder Evaluation
Along with a pneumatic pressure or valve closure, you can
record the logic input from control signals. Select from a
rich lineup of Hioki input units that support a wide range of
sensors and converters.
MR8827
10
Main unit Specifications
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
MEMORY (high-speed recording)
Measurement functions
MEMORY (high-speed recording)
RECORDER (real-time recording)
X-Y RECORDER (X-Y real-time recording)
FFT (frequency analysis)
Time axis
5 μs to 5 min/div (100 samples/div) 26 ranges, External sampling (100
samples/div, or free setting),
Time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to 1/20000 in 13
stages
Main unit OS
μ ITRON (Non-Windows OS)
Sampling period
1/100 of time axis range (minimum 50 ns period)
Recording length
Built-in presets: (at 4, 8, 16ch mode) 25 to 20000 div, (at 4, 8 ch mode) 25
to 500000 div (at 4 ch mode) 25 to 1000000 div
Arbitrary presets: setting in 1 div steps, Max. 1280000 div (at 4ch mode),
640000 div (at 8ch mode), 320000 div (at 16ch mode), 160000 div (at 32ch
Pre-trigger
Record data from before the trigger point at 0 to +100% or -95% of the
recording length in 15 stages, or in 1 div step settings
[16 analog input modules]: 32 analog channels + 32 logic channels (logic
Number of channels
(Max.)
probe terminals standard, logic has common GND)
[14 analog input modules + 2 logic input modules]: 28 analog channels + 64
logic channels (standard 32 channels + 32 channels in Logic unit 8973 ×2)
mode)
* Max. up to two modules of the Logic Unit 8973, the Current Unit 8971 up to four modules
Maximum sampling
rate
20 MS/second (all channels simultaneously)
Internal memory
16MW/ch (total capacity 512MW memory), 16MW/ch (using 32 analog channels), 32MW/ch (using 16 analog channels), 64MW/ch (using 8 analog channels),
128MW/ch (using 4 analog channels)
Data storage media
CF card slot (standard) ×1 (up to 2GB, FAT, or FAT-32 format), USB port
×2 (USB 2.0)
Backup battery life
Clock and parameter setting backup: at least 10 years (reference value at
25°C)
External trigger input, Trigger output, External sampling input, GND,
External control conTwo external outputs (GO/NG output), Three external inputs (start/IN1, stop/
nectors
IN2, save/IN3)
LAN: 100BASE-TX (DHCP, DNS supported, FTP server, HTTP server)
External interfaces
USB: USB 2.0 compliant, series A receptacle ×1, series B receptacle ×1,
(File transfer SSD/ CF card to PC, or remote control from PC)
Environmental condi- Operation: 0°C to 40°C (32°F to 104°F), 20% to 80% rh
tions (No condensation) Storage: -10°C to 50°C (14°F to 122°F), 90% rh or less
Standards
Safety: EN61010
EMC: EN61326, EN61000-3-2, EN61000-3-3
Power supply
AC 100 to 240 V, 50/60 Hz
Power consumption
220 VA max. (when not using the printer), 350 VA max. (when using the
printer)
• Simultaneous calculation for up to 16 selected channels
Average value, effective (rms) value, peak to peak value, maximum
value, time to maximum value, minimum value, time to minimum value,
period, frequency, rise time, fall time, standard deviation, area value,
X-Y area value, specified level time, specified time level, pulse width,
Numerical calculation
duty ratio, pulse count, four arithmetic operations, time difference, phase
difference, high-level and low-level
• Calculation result evaluation output: GO/NG (with open-collector 5 V output)
• Automatic storing of calculation results
• For up to 16 freely selectable channels, the following functions can be
performed
Four arithmetic operations, absolute value, exponentiation, common
logarithm, square root, moving average, differentiation (primary,
Waveform processing
secondary), integration (primary, secondary), parallel displacement
along time axis, trigonometric functions, reverse trigonometric
functions, integration time correction for each NPLC setting, auto-saves
of calculation results
Memory segmentation • Max. 1024 blocks, sequential storage, multi-block storage
Other functions
401 mm (15.79 in)W × 233 mm (9.17 in)H × 388 mm (15.28 in)D, 12.6 kg
Dimensions and mass
(444.4 oz) (main unit only)
Supplied accessories
Instruction manual ×1, Application disk (Wave Viewer Wv, Communication
commands table) ×1, Power cord ×1, Input cord label ×1, USB cable ×1,
Printer paper ×1 (when equipped with a printer unit), Roll paper attachment
×2 (when equipped with a printer unit)
• X-Y waveform synthesis (1 screen, 4 screens)
• Overlay (always overlay when started/overlay only required waveforms)
• Automatic/ Manual/ A-B cursor range printing/ Report printing
• Logging is not available
Memory recording method
Sampling period
Sampling is done at the set
sampling period.
PRINTER UNIT U8350 (Factory-installed option)
Features
Printer paper one-touch loading, high-speed thermal printing
Recording paper
216 mm (8.50 in) × 30 m (98.43 ft), thermal paper roll (use the 9231 paper)
Recording witdh: 200 mm (7.87 in) 20 division full scale, 1 div = 10 mm
(0.39 in) 80 dots
Recording speed
Max. 50 mm (1.97 in)/sec
Paper feed density
10 lines/mm
RECORDER (Real-time recording)
10 ms to 1 hour/div, 19 ranges, time axis resolution 100 points/div
Time axis
Note: Out of data acquired at selected sampling rate, only maximum and
minimum value data determined using 100 points/div units are stored
Time axis compression selectable in 13 steps, from × 1/2 to × 1/20000
Sampling rate
1/10/100 µs 1/10/100 ms (selectable from 1/100 or less of time axis)
Supported
Display
* Real-time printing is possible at time axis settings slower than 500 ms/div
Display
10.4 inch SVGA-TFT color LCD (800 × 600 dots)
(Time axis 25 div × Voltage axis 20 div, X-Y 20 div × 20 div)
Languages
English, Japanese, Korean, Chinese
Waveform display
zoom/compression
Time axis: ×10 to ×2 (zoom at MEMORY function only), ×1, ×1/2 to
×1/20000, Voltage axis: ×100 to ×2, ×1, ×1/2 to ×1/10
Recording length
Built-in presets of 25 - 50000 div, or ‘‘Continuous’’ or arbitrary setting in
1 div steps (max. 80000 div)
Variable display
Upper/Lower limit set, display/div set
Waveform memory
Store data for most recent 80000 div in memory
Scaling
10:1 to 1000:1, automatic scaling for various probes
Manual scaling (conversion ratio setting, 2-point setting, unit setting)
Auto save
Data is automatically saved on CF card, USB memory stick or internal
SSD after measurement stops
Comment input
Alphanumeric input (title, analog and logic channels)
Simple input, history input, phrase input
Other functions
• Manual/ A-B cursor range printing/ Report printing
• Logging is not available
Logic waveform
Display point move 1 % step, Line width 3 types
Display partition
Max. eight divisions
Monitor function
• Input level monitor
• Numerical value (Sampling 10kS/s fixed, refresh rate 0.5s)
Other display functions
• Waveform inversion (positive/negative)
• Cursor measurement (A, B, 2-cursor, for all channels)
• Vernier function (amplitude fine adjustment)
• Zoom function (horizontal screen division, zoomed waveform shown in lower
section)
• 16 selectable colors for waveform display
• Zero position shift in 1% steps for analog waveform
• Global zero adjust for all channels and all ranges
Real-time printing
* Delayed print is performed when recording length is not set to ‘‘Continuous’’
and time axis setting is 10 ms - 200 ms/div
* When recording length is set to ‘‘Continuous’’ and time axis setting is 10 ms 200 ms/div, manual printing can be performed after measurement stop
Recorder recording method
High-speed sampling is
performed at the set sampling
frequency, culling data
Culling save
other than the maximum and
minimum values to create the
recording data of a certain
High-speed sampling
time.
Sampling period
Max.
Min.
11
MEMORY HiCORDER MR8827
X-Y RECORDER (X-Y real-time recording)
Trigger functions
Sampling period
1/10/100 ms (dot), 10/100 ms (line)
Trigger mode
MEMORY (high-speed recording), FFT: Single, Repeat, Auto
RECORDER (real-time recording): Single, Repeat
Recording length
Continuous
Trigger sources
CH1 to CH32 (analog), Standard Logic 32ch + Logic Unit (Max. 2 units 32
channels), External (a rise of 2.5V or terminal short circuit), Timer, Manual
(either ON or OFF for each source),
Logical AND/OR of sources
Screen, Printing
Split screen (1 or 4), Manual printing only
Number of X-Y
1 to 8 phenomenon
X-Y channel setting
Any 8 channels out of 16 can be selected for X axis and Y axis
respectively
X-Y axis resolution
25 dots/div (screen), horizontal 80 dots/div × vertical 80 dots/div (printer)
Waveform memory
Sampling data for last 16000000 points are stored in memory
Pen up/down
Simultaneous for all phenomena
External pen control
Possible via external input connector (simultaneous up/down for all
• Level: Triggering occurs when preset voltage level is crossed (upwards or
downwards)
Trigger types
phenomena)
FFT
Analysis mode
Storage waveform, Linear spectrum, RMS spectrum, Power spectrum,
Density of power spectrum, Cross power spectrum,
Auto-correlation function, Histogram, Transfer function, Crosscorrelation function, Impulse response, Coherence function,
1/1 Octave analysis, 1/3 Octave analysis, LPC analysis, Phase spectrum
Analysis channels
Selectable from all analog input channels
Frequency range
133 mHz to 8 MHz, External, (resolution 1/400, 1/800, 1/2000, 1/4000)
Number of sampling
points
1000, 2000, 5000, 10000 points
Window functions
Rectangular, Hanning, Hamming, Blackman, Blackman-Harris, Flat-top,
Exponential
Display format
Single, Dual, Nyquist, Running spectrum
Averaging function
Time axis / frequency axis simple averaging, Exponential averaging, Peak
hold (frequency axis),
Averaging times (2 to 10000 times)
Print functions
Same as the MEMORY function (partial print not available)
• Voltage drop: Triggering occurs when voltage drops below peak voltage
setting (for 50/60 Hz AC power lines only)
• Window: Triggering occurs when window defined by upper and lower
limit is entered or exited
• Period: Rising edge or falling edge cycle of preset voltage value is
monitored and triggering occurs when defined cycle range is exceeded
• Glitch: Triggering occurs when pulse width from rising or falling edge
of preset voltage value is under run
• Event setting: Event count is performed for each source, and triggering
occurs when a preset count is exceeded
• Logic: 1, 0, or ×, Pattern setting
Level setting
resolution
0.1% of full scale (full scale = 20 divisions)
Trigger filter
Selectable 0.1 div to 10.0 div 9 steps, or OFF (at MEMORY function)
ON (10 ms fixed) or OFF (at RECORDER function)
Trigger output
Other functions
Open collector (5 voltage output, active Low)
At Level setting: pulse width (Sampling period × data number after trigger)
At Pulse setting: pulse width (2 ms)
Trigger priority (OFF/ON), Pre-trigger function for capturing data from
before / after trigger event (at MEMORY function), Level display during
trigger standby, Start and stop trigger (At RECORDER function), Trigger
search function
Other functions
Waveform judgment
function
(In MEMORY or FFT
function)
• Area comparison with reference waveform area for time domain
waveform, X-Y waveform, or FFT analysis waveform
• Parameter calculated value comparison with reference value
• Output: GO/NG decision, Open-collector 5V,
*100 msec/div (1 msec sampling) and thereafter allows for evaluation in almost
real-time.
How is FFT Analysis Performed?
Designate a range of the wave-
Waveform in the
MEM function
form stored in the memory func-
changes over time in 3-D.
tion to perform FFT analysis. It
is rendered simultaneously on
the screen.
D is pl ay t h e s p e c t r u m a s i t
FFT analysis
V
dB
Convert data measured with few
1000P
calculation points into data with
value (sum of the power spec-
many points for re-analysis.
*Not possible with frequency
averaging ON
Scale by dB. Input the overall
trum) directly as a dB value.
10000P
-6.51 dB
93.50 dB
Before scaling
After scaling
12
Optional Specifications (sold separately)
Dimensions and mass: approx. 106 mm (4.17 in) W ×
19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: None
ANALOG UNIT 8966
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for voltage measurement
Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF),
Max. rated voltage to ground: 300 V AC or DC (with input isolated from the main unit,
Input terminals
the maximum voltage that can be applied between input channel and chassis, and between
input channels without damage)
5 mV to 20 V/div, 12 ranges, full scale: 20 div,
AC voltage for possible measurement/display using the memory function: 280 V rms,
Measurement range
Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz
Measurement resolution 1/100 of range (using 12-bit A/D conversion)
20 MS/s (simultaneous sampling in 2 channels)
Maximum sampling rate
Measurement accuracy ±0.5% of full scale (with filter 5 Hz, zero position accuracy included)
Frequency
DC to 5 MHz -3 dB, (with AC coupling: 7 Hz to 5 MHz -3 dB)
characteristics
AC/DC/GND
Input coupling
400 V DC (maximum voltage that can be applied between input connectors without
Maximum input voltage
damage)
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 204.5 mm (8.05 in) D, approx. 240 g (8.5 oz)
Accessories: Ferrite clamp × 2
TEMP UNIT 8967
Measurement functions
Input terminals
Temperature measurement
range
Note: Upper and lower limit values
depend on the thermocouple
Thermocouple range
(JIS C 1602-1995)
(ASTM E-988-96)
Data refresh rate
Measurement accuracy
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Number of channels: 2, for temperature measurement with thermocouple (voltage
measurement not available)
Thermocouple input: plug-in connector, Recommended wire diameter: single-wire, 0.14 to 1.5
mm 2, braided wire 0.14 to 1.0 mm 2 (conductor wire diameter min. 0.18 mm), AWG 26 to 16
Input impedance: min. 5 M Ω (with line fault detection ON/OFF),
Max. rated voltage to ground: 300 V AC or DC (with input isolated from the main unit, the
maximum voltage that can be applied between input channel and chassis, and between input
channels without damage)
10°C (50°F)/div (-100°C to 200°C (-148°F to 392°F)), 50°C (122°F)/div (-200°C to 1000°C
(-328°F to 1832°F)), 100°C (212°F)/div (-200°C to 2000°C (-328°F to 3632°F)), 3 ranges,
full scale: 20 div,
Measurement resolution: 1/1000 of measurement range (using 16-bit A/D conversion)
K: -200°C to 1350°C (-328°F to 2462°F), J: -200°C to 1100°C (-328°F to 2012°F), E: -200°C
to 800°C (-328°F to 1472°F), T: -200°C to 400°C (-328°F to 752°F), N: -200°C to 1300°C
(-328°F to 2372°F), R: 0°C to 1700°C (32°F to 3092°F), S: 0°C to 1700°C (32°F to 3092°F),
B: 400°C to 1800°C (752°F to 3272°F), W (WRe5-26): 0°C to 2000°C (32°F to 3632°F),
Reference junction compensation: internal/ external (switchable), Line fault detection ON/
OFF possible
3 methods, Fast: 1.2 ms (digital filter OFF), Normal: 100 ms (digital filter 50/60 Hz), Slow:
500 ms (digital filter 10 Hz)
Thermocouple K, J, E, T, N: ±0.1% of full scale ±1°C (±1.8°F) (±0.1% of full scale ±2°C
(±3.6°F) at -200°C to 0°C (-328°F to 32°F)),
Thermocouple R, S, B, W: ±0.1% of full scale ±3.5°C (±6.3°F) (at 0°C (32°F) to less than 400°C
(752°F); However, no accuracy guarantee of less than 400°C (752°F) for B), ±0.1% f.s. ±3°C
(±5.4°F) (at 400°C (752°F) or more)
Reference junction compensation accuracy: ±1.5°C (±2.7°F) (added to measurement accuracy
with internal reference junction compensation)
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: None
HIGH RESOLUTION UNIT 8968
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for voltage measurement
Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF),
Max. rated voltage to ground: 300 V AC, DC (with input isolated from the unit,
Input terminals
the maximum voltage that can be applied between input channel and chassis and between
input channels without damage)
5 mV to 20 V/div, 12 ranges, full scale: 20 div,
AC voltage for possible measurement/display using the memory function: 280 V rms,
Measurement range
Low-pass filter: 5/50/500 Hz, 5k/50k Hz
Integrated filter for suppressing aliasing distortion caused by FFT processing (automatic
Anti-aliasing filter
cutoff frequency setting/OFF)
Measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion)
Maximum sampling rate
Measurement accuracy
Frequency
characteristics
Input coupling
Maximum input voltage
1 MS/s (simultaneous sampling in 2 channels)
±0.3% of full scale (with filter 5 Hz, zero position accuracy included)
DC to 100 kHz -3 dB (with AC coupling: 7 Hz to 100 kHz -3 dB)
AC/DC/GND
400 V DC (maximum voltage that can be applied between input connectors without
damage)
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 220 g (7.8 oz)
Accessories: Conversion cable 9769 × 2 (cable length 50 cm/1.64 ft)
STRAIN UNIT 8969
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and autobalance; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Number of channels: 2, for distortion measurement (electronic auto-balancing, balance
adjustment range
within ±10 000 µe or less)
Weidmuller SL 3.5/7/90G
(via Conversion Cable 9769, TAJIMI PRC03-12A10-7M10.5)
Max. rated voltage to ground: 33 V rms or 70 V DC (with input isolated from the unit,
Input terminals
the maximum voltage that can be applied between input channel and chassis and between
input channels without damage)
Strain gauge converter, Bridge impedance: 120 Ω to 1 kΩ, Bridge voltage: 2 V ±0.05 V,
Suitable transducer
Gauge rate: 2.0
20 µe to 1000 µe/div, 6 ranges, full scale: 20 div,
Measurement range
Low-pass filter: 5/10/100 Hz, 1 kHz
Measurement resolution 1/1250 of measurement range (using 16-bit A/D conversion)
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: None
FREQ UNIT 8970
Measurement functions
Number of channels: 2, for voltage input based frequency measurement, rotation, power
frequency, integration, pulse duty ratio, pulse width
Input terminals
Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF),
Max. rated voltage to ground: 300 V AC or DC (with input isolated from the main unit,
the maximum voltage that can be applied between input channel and chassis, and between
input channels without damage)
Frequency mode
Range: Between DC to 100 kHz (minimum pulse width 2 μs), 1 Hz/div to 5 kHz/div (full
scale = 20 div), 8 settings
Accuracy: ±0.1% f.s. (exclude 5 kHz/div), ±0.7% f.s. (at 5 kHz/div)
Rotation mode
Range: Bet ween 0 to 2 million rotations/minute (minimu m pulse width 2 μs),
100 (r/min)/div to 100 k (r/min)/div (full scale = 20 div), 7 settings
Accuracy: ±0.1% f.s. (excluding 100 k (r/min)/div), ±0.7% f.s. (at 100 k (r/min)/div)
Power frequency mode
Range: 50 Hz (40 to 60 Hz), 60 Hz (50 to 70 Hz), 400 Hz (390 to 410 Hz) (full scale =
20 div), 3 settings
Accuracy: ±0.03 Hz (50, 60 Hz), ±0.1 Hz (400 Hz range)
Integration mode
Range: 2 k counts/div to 1 M counts/div, 6 settings
Accuracy: ±range/2000
Duty ratio mode
Range: Between 10 Hz to 100 kHz (minimum pulse width 2 μs), 5%/div (full scale =
20 div)
Accuracy: ±1% (10 Hz to 10 kHz), ±4% (10 kHz to 100 kHz)
Pulse width mode
Range: Between 2 μs to 2 sec, 500 μs/div to 100 ms/dv (full scale = 20 div), Accuracy:
±0.1% f.s.
Measurement resolution
1/2000 of range (Integration mode), 1/500 of range (exclude integration, power frequency
mode), 1/100 of range (power frequency mode)
Input voltage range and
threshold level
±10 V to ±400 V, 6 settings, selectable threshold level at each range
Other functions
Slope, Level, Hold, Smoothing, Low-pass filter, Switchable DC/AC input coupling,
Frequency dividing, Integration over-range keep/return
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm (0.78 in)
H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: CONVERSION CABLE 9318 × 2
(To connect the current sensor to the 8971)
CURRENT UNIT 8971
200 kS/s (simultaneous sampling across 2 channels)
±(0.5% f.s. +4 µe) (5 Hz filter ON)
DC to 20 kHz +1/-3 dB
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, Current measurement with optional current sensor,
Input terminals
Sensor connector (input impedance 1 MΩ, exclusive connector for current sensor via
conversion cable the 9318, common GND with recorder)
Compatible current
sensors
CT6863, CT6862, 9709, CT6841, CT6843, CT6844, CT6845, 9272-10 (To connect the 8971
via conversion cable the 9318)
Measurement range
Using 9272-10 (20 A), CT6841: 100 mA to 5 A/div (f.s. = 20 div, 6 settings)
Using CT6862: 200 mA to 10 A/div (f.s. = 20 div, 6 settings)
Using 9272-10 (200 A), CT6843, CT6863: 1 A to 50 A/div
(f.s. = 20 div, 6 settings)
Using CT6844, CT6845, 9709: 2 A to 100 A/div (f.s. = 20 div, 6 settings)
Measurement accuracy
(with 5 Hz filter ON)
Note: Add the accuracy
and attributes of the
current sensor being used.
±0.65% f.s.
RMS amplitude accuracy: ±1% f.s. (DC, 30 Hz to 1 kHz), ±3% f.s. (1 kHz to 10 kHz)
RMS response time: 100 ms (rise time from 0 to 90% of full scale),
Crest factor: 2
Frequency characteristics: DC to 100 kHz, ±3 dB (with AC coupling: 7 Hz to 100 kHz)
Measurement resolution 1/100 of range (using 12-bit A/D conversion)
Maximum sampling rate
1 MS/s (simultaneous sampling in 2 channels)
Other functions
Input coupling: AC/DC/GND, Low-pass filter: 5, 50, 500, 5 k, 50 kHz
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: None
DC/RMS UNIT 8972
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for voltage measurement, DC/RMS selectable
Input terminals
Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF),
Max. rated voltage to ground: 300 V AC or DC (with input isolated from the main unit,
the maximum voltage that can be applied between input channel and chassis, and between
input channels without damage)
Measurement range
5 mV to 20 V/div, 12 ranges, full scale: 20 div,
AC voltage for possible measurement/display using the memory function: 280 V rms,
Low-pass filter: 5/50/500 Hz, 5 k/100 kHz
Measurement resolution 1/100 of range (using 12-bit A/D conversion)
Maximum sampling rate
1 MS/s (simultaneous sampling in 2 channels)
Measurement accuracy
±0.5% of full scale (with filter 5 Hz, zero position accuracy included)
RMS measurement
RMS amplitude accuracy: ±1% f.s. (DC, 30 Hz to 1 kHz), ±3% of full scale (1 kHz to
100 kHz)
Response time: SLOW 5 s (rise time from 0 to 90% of full scale), MID 800 ms (rise time
from 0 to 90% of full scale), FAST 100 ms (rise time from 0 to 90% of full scale),
Crest factor: 2
Frequency
characteristics
DC to 400 kHz -3 dB, (with AC coupling: 7 Hz to 400 kHz -3 dB)
Input coupling
AC/DC/GND
Maximum input voltage
400 V DC (maximum voltage that can be applied between input connectors without
damage)
Measurement functions
Maximum sampling rate
Measurement accuracy
After auto-balancing
Frequency
characteristics
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time;
Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 190 g (6.7 oz)
Accessories: None
LOGIC UNIT 8973
Measurement functions Number of channels: 16 channels (4 ch/1 probe connector × 4 connectors)
Input terminals
Mini DIN connector (for HIOKI logic probes only),
Compatible logic probes: 9320-01, 9327, MR9321-01
13
MEMORY HiCORDER MR8827
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 260 g (9.2 oz)
Accessories: None
DIGITAL VOLTMETER UNIT MR8990
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and calibration,
Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for DC voltage measurement
Input terminals
Banana input connectors (Input resistance: 100 MΩ or higher with 100 mV f.s. to 10 V f.s.
range, otherwise 10 MΩ)
Max. rated voltage to ground: 300 V AC or DC (with input isolated from the main unit,
the maximum voltage that can be applied between input channel and chassis, and between
input channels without damage)
Measurement range
100 mV f.s. (5 mV/div) to 1000 V f.s. (50 V/div), 5 ranges, full scale: 20 div
Measurement resolution
1/50 000 of measurement range (using 24 bit ΔΣ modulation A/D)
Integration time
20 ms ×NPLC (during 50 Hz), 16.67 ms ×NPLC (during 60 Hz)
Response time
2 ms +2× integration time or less (rise - f.s. → + f.s., fall + f.s. → - f.s.)
Basic measurement
accuracy
±0.01% rdg. ±0.0025% f.s. (at range of 1000 mV f.s.)
Maximum input voltage
500 V DC (maximum voltage that can be applied between input connectors without damage)
NEW
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 230 g (8.1 oz)
Accessories: None
HIGH-VOLTAGE UNIT U8974
(Accuracy at 23 ±5°C/73 ±9°F, 20 to 80% rh after 30 minutes of warm-up time and zero
adjustment; Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement functions
Number of channels: 2, for voltage measurement, DC/RMS selectable
Maximum rated voltage to ground: 1000 V AC or DC (CAT III), 600 V AC or DC
(CAT IV)
Input terminals
Banana input terminal (Input impedance: 4 MΩ, Input capacitance: 5 pF)
Measurement range
200 mV, 500 mV, 1, 2, 5, 10, 20, 50 V/div (DC mode)
500 mV, 1, 2, 5, 10, 20, 50 V/div (RMS mode)
Measurement
resolution
1/1600 of measurement range (using 16-bit A/D conversion)
Maximum sampling rate
1 MS/s
Measurement accuracy
±0.25% f.s. (with filter 5 Hz, zero position accuracy included)
RMS measurement
RMS accuracy: ±1.5% f.s. (DC, 30 Hz to 1 kHz), ±3% f.s. (1 kHz to 100 kHz)
Response time: High speed 150 ms, Medium speed 500 ms, Low speed 2.5 s
Frequency
characteristics
DC to 100 kHz -3 dB
Input coupling
DC / GND
Maximum input voltage
1000 V DC, 700 V AC
NEW
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 250 g (8.8 oz)
Accessories: None
ARBITRARY WAVEFORM GENERATOR UNIT U8793
Output terminal
Output voltage range
Max. output current
FG function
Arbitrary waveform
generator mode
Sweep function
Program function
Other
(Accuracy at 23 ±5°C/73 ±9°F, 80% rh or less after 30 minutes or more of warm-up time;
Power supply frequency range of installed MEMORY HiCORDER at 50 Hz/60 Hz ±2 Hz;
Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Number of channels: 2, SMB terminal (Output impedance: 1 Ω or less)
Max. rated voltage to ground: 33 V rms AC or 70 V DC
-10 V to 15 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
10 mA (Allowable load resistance: 1.5 kΩ or more)
DC, Sine wave, Square wave, Pulse wave, Triangular wave, Ramp wave, Output
frequency: 0 Hz to 100 kHz
Waveforms measured by MR8847A, etc., generated by Hioki Model 7075 or SF8000, CSV waveforms
D/A refresh rate: 2 MHz (using 16-bit D/A)
Frequency, Amplitude, Offset, Duty (Pulse only)
Max. 128 steps (Number of loops for each step, Number of total loops)
Self-test function (Voltage), External input/output control
Cable length and mass: Input side: 70 cm (2.30 ft), Output side: 1.5 m
(4.92 ft), Approx. 170 g (6.0 oz)
DIFFERENTIAL PROBE P9000
Measurement modes
Division ratio
DC output accuracy
Effective value
measurement accuracy
Input resistance/
capacity
Maximum input voltage
Maximum rated voltage to
ground
Operating temperature
range
Power supply
Accessories
(Accuracy guaranteed for 1 year,
Post-adjustment accuracy guaranteed for 1 year)
P9000-01: For waveform monitor output, Frequency characteristics: DC to 100 kHz
-3 dB
P9000-02: Switches between waveform monitor output/AC effective value output
Wave mode frequency characteristics: DC to 100 kHz -3 dB,
RMS mode frequency characteristics: 30 Hz to 10 kHz, Response time: Rise
300 ms, Fall 600 ms
Switches between 1000:1, 100:1
±0.5% f.s. (f.s. = 1.0 V, division ratio 1000:1), (f.s. = 3.5 V, division ratio 100:1)
±1% f.s. (30 Hz to less than 1 kHz, sine wave), ±3% f.s. (1 kHz to 10 kHz, sine wave)
H-L: 10.5 MΩ, 5 pF or less (At 100 kHz)
1000 V AC, DC
1000 V AC, DC (CAT III)
-40°C to 80°C (-40°F to 176°F)
(1) AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 6 VA (including AC adapter),
0.9 VA (main unit only)
(2) USB bus power (5 V DC, USB micro-B connector), 0.8 VA
(3) External power source 2.7 V to 15 V DC, 1 VA
Instruction manual ×1, Alligator clip ×2, Carrying case ×1
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section
cable 46 cm (1.51 ft), approx. 350 g (12.3 oz)
DIFFERENTIAL PROBE 9322
(Accuracy guaranteed for 1 year)
Functions
For high-voltage f loating measurement, power line surge noise detection, RMS
rectified output measurement
DC mode
For waveform monitor output, Frequency characteristics: DC to 10 MHz (±3 dB),
Amplitude accuracy: ±1% of full scale (at max. 1000 V DC), ±3% of full scale (at
max. 2000 V DC) (full scale: 2000 V DC)
AC mode
For detection of power line surge noise, Frequency characteristics: 1 kHz to 10 MHz
±3 dB
RMS mode
DC/AC voltage RMS output detection, Frequency characteristics: DC, 40 Hz to 100
kHz, Response speed: 200 ms or less (400 V AC), Accuracy: ±1% of full scale (DC,
40 Hz to 1 kHz), ±4% of full scale (1 kHz to 100 kHz) (full scale: 1000 V AC)
Input
Input type: balanced differential input, Input impedance/capacitance: H-L 9 MΩ/
10 pF, H/L-unit 4.5 MΩ/20 pF,
Max. rated voltage to ground: when using grabber clip 1500 V AC/DC (CAT II),
600 V AC/DC (CAT III), when using alligator clip: 1000 V AC/DC (CAT II), 600 V
AC/DC (CAT III)
Maximum input voltage
2000 V DC, 1000 V AC (CAT II), 600 V AC/DC (CAT III)
Output
Voltage divider for 1/1000 of input, BNC connectors (output switchable for 3 modes
DC, AC, RMS)
Power supply
Any of the following: (1) AC Adapte 9418-15, (2) Power Cord 9248 with Probe Power
Unit 9687, (3) Power Cord 9324 + Conversion Cable 9323 with HiCORDER
logic terminal, (4) Power Cord 9325 with F/V Unit 8940
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section
cable 30 cm (0.98 ft), approx. 150 g (5.3 oz)
Note: The unit-side plug of the 9320-01 and 9327 is different from the 9320.
LOGIC PROBE 9320 -01/9327
NEW
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 230 g (8.1 oz)
Accessories: None
WAVEFORM GENERATOR UNIT MR8790
(Accuracy at 23 ±5°C/73 ±9°F, 80% rh after 30 minutes of warm-up time;
Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Output terminal
Number of channels: 4, SMB terminal (Output impedance: 1 Ω or less)
Max. rated voltage to ground: 33 V rms AC or 70 V DC
Output voltage range
-10 V to 10 V (Amplitude setting range: 0 V to 20 V p-p, Setting resolution: 1 mV)
Max. output current
5 mA
Output function
DC, Sine wave (Output frequency range: 0 Hz to 20 kHz)
Accuracy
Amplitude accuracy: ±0.25% of setting ±2 mV p-p (1 Hz to 10 kHz)
Offset accuracy: ±3 mV
DC output accuracy: ±0.6 mV
Other
Self-test function (Voltage, Current)
NEW
Dimensions and mass: approx. 106 mm (4.17 in) W × 19.8 mm
(0.78 in) H × 196.5 mm (7.74 in) D, approx. 230 g (8.1 oz)
Accessories: None
PULSE GENERATOR UNIT MR8791
Output terminal
Output mode 1
Output mode 2
Other
(Accuracy at 23 ±5°C/73 ±9°F, 80% rh or less with no condensation;
Accuracy guaranteed for 1 year)
Number of channels: 8, Connector: D-sub, half-pitch, 50-pin
Max. rated voltage to ground: 33 V rms AC or 70 V DC (between unit and output channels)
Logic output/Open collector output
Pattern output: Read frequency: 0 Hz to 120 kHz, 2048 logic patterns
Pulse output: Frequency 0 Hz to 20 kHz, Duty 0.1% to 99.9%
Logic output: Output voltage level: 0 V to 5 V
(H level: 3.8 V or more, L level: 0.8 V or less)
Open collector output: Absolute maximum rated voltage for collector/emitter: 50 V
Overcurrent protection: 100 mA
Self-test function
Functions
Detection of voltage signal or relay contact signal for High/Low state recording
Input
4 channels (common ground between unit and channels), digital/contact input,
switchable (contact input can detect open-collector signals)
Input resistance: 1 MΩ (with digital input, 0 to +5 V)
500 kΩ or more (with digital input, +5 to +50 V)
Pull-up resistance: 2 kΩ (contact input: internally pulled up to +5 V)
Digital input threshold
1.4 V/ 2.5 V/ 4.0 V
Contact input
detection resistance
1.4 V: 1.5 kΩ or higher (open) and 500 Ω or lower (short)
2.5 V: 3.5 kΩ or higher (open) and 1.5 kΩ or lower (short)
4.0 V: 25 kΩ or higher (open) and 8 kΩ or lower (short)
Response speed
9320-01: 500 ns or lower, 9327: detectable pulse width 100 ns or higher
Maximum input voltage
0 to +50 V DC (the maximum voltage that can be applied across input pins without
damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m
(3.28 ft), approx. 320 g (11.3 oz)
Note: The unit-side plug of the MR9321-01 is different from the MR9321.
LOGIC PROBE MR9321-01
Detection of AC or DC relay drive signal for High/Low state recording
Can also be used for power line interruption detection
4 channels (isolated between unit and channels), HIGH/LOW range switching
Input
Input resistance: 100 kΩ or higher (HIGH range), 30 kΩ or higher (LOW range)
170 to 250 V AC, ±DC 70 to 250 V (HIGH range)
Output (H) detection
60 to 150 V AC, ±DC 20 to 150 V (LOW range)
0 to 30 V AC, ±DC 0 to 43 V (HIGH range)
Output (L) detection
0 to 10 V AC, ±DC 0 to 15 V (LOW range)
Rising edge 1 ms max., falling edge 3 ms max. (with HIGH range at 200 V DC, LOW
Response time
range at 100 V DC)
250 V rms (HIGH range), 150 V rms (LOW range) (the maximum voltage that can be
Maximum input voltage
applied across input pins without damage)
Functions
14
System Chart of Options
Model : MEMORY HiCORDER MR8827
Model Name
(Order Code)
Input modules
(Note)
* Input cords not included. Please purchase them separately.
* When using 9709 with Current Unit 8971, a total of 7 current probes can be used.
ANALOG UNIT 8966
2 ch, Voltage input, DC to 5 MHz bandwidth
MR8827
(Max. 32ch, 512MW memory, main unit only)
*Cannot operate alone, You must install other options
TEMP UNIT 8967
2 ch, thermocouple temperature input
HIGH RESOLUTION UNIT 8968
2 ch, voltage input, DC to 100 kHz bandwidth
STRAIN UNIT 8969
2 ch, strain gauge type converter amp
Conversion Cable 9769
(For and bundled with the strain unit)
FREQ UNIT 8970
2 ch, for measurement of frequency, RPM, pulse, etc.
CURRENT UNIT 8971
2 ch, for measuring current using dedicated current sensors,
bundled two Conversion cable 9318
Note: Max. up to 4 modules can be installed in the MR8847A, MR8827
Note: Main unit MR8827 cannot operate alone. You must install
one or more optional input modules in the unit.
Printer options
DC/RMS UNIT 8972
2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100
kHz bandwidth
*PRINTER UNIT is a built-in option that must be
specified upon order.
PRINTER UNIT U8350
Specified upon order. Printing width 200 mm (7.87 inch).
Compatible recording paper: Model 9231
LOGIC UNIT 8973
RECORDING PAPER 9231
DIGITAL VOLTMETER UNIT MR8990
4 terminals, 16 ch
Note: Max. up to 2 modules can be installed in the MR8827
A4 width 216 mm (8.50 in) × 30 m (98.43 ft), 6 rolls/set
2ch, high-precision DC V, 0.1 μV resolution, maximum sampling
rate 500 times/s
NEW
Storage media
HIGH-VOLTAGE UNIT U8974
2ch, voltage input, max. 1000 V DC and 700 V AC
* SSD is a built-in option that must be specified upon
order. * The CF card includes a PC card adapter.
SSD UNIT U8330
Specified upon order; built-in type, 128 GB
Output modules
WAVEFORM GENERATOR UNIT MR8790
NEW
PULSE GENERATOR UNIT MR8791
NEW
ARBITRARY WAVEFORM GENERATOR UNIT U8793
* CF Card Precaution
Use only CF Cards sold by HIOKI. Compatibility and performance are not
guaranteed for CF cards made by other manufacturers. You may be unable to read
from or save data to such cards.
* Input cords not included. Please purchase separately.
NEW
PC CARD 2G 9830
4ch, DC Output: ±10 V,
Sine wave output: 10 mHz to 20 kHz
8ch, Pulse output: 0.1 Hz to 20 kHz, Pattern output
(2 GB)
PC CARD 1G 9729
(1 GB)
PC CARD 512M 9728
2ch, 10 mHz to 100 kHz function generator, arbitrary waveform
generator with 2 MHz D/A refresh rate, -10 V to 15 V output
(512 MB)
PC Software
Output cable
WAVE PROCESSOR 9335
CONNECTION CABLE L9795-01
NEW
CONNECTION CABLE L9795-02
Convert data, print and display waveforms
LAN COMMUNICATOR 9333
• Waveform data collect function
• Remote control with the PC
* Please contact your local HIOKI distributor for
connectors that support Model MR8791.
NEW
Maximum rated voltage to ground: 33 V AC
rms or 70 V DC, SMB terminal - alligator
clip, Cord length: 1.5 m (4.92 ft)
Maximum rated voltage to ground: 33 V
AC rms or 70 V DC, SMB terminal - BNC
terminal, Cord length: 1.5 m (4.92 ft)
iPad App for MEMORY HiCORDER HMR
Terminal
Download from the App Store (exclusively for
Apple iPad)
LAN CABLE 9642
Straight Ethernet cable, supplied with straight
to cross conversion cable, 5 m (16.41 ft) length
Logic signal measurement
LOGIC PROBE 9327
Recommended
LOGIC PROBE MR9321-01
Recommended
4-channel type, for voltage/contact signal ON/
OFF detection (response pulse width 100 ns
or more, miniature terminal type)
4 isolated channels, ON/OFF detection of AC/
DC voltage (miniature terminal type)
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal ON/
OFF detection (response pulse width 500 ns
or more, miniature terminal type)
Case
CONVERSION CABLE 9323
CARRYING CASE (special order)
hard trunk type
Inquire with your local Hioki distributor.
* Used for connecting the 9320/9321/MR9321 and the
9324 to the Memory HiCorder with small logic terminal
models * This cable is not required for the small-terminal
types 9327, 9320-01, 9321-01 and MR9321-01.
15
MEMORY HiCORDER MR8827
* You can connect up to 4 Current Unit 8971 to the Memory HiCorder main unit, allowing up to 8 current sensors to be used.
* There is no limit if you connect a current sensor to the voltage input analog unit.
INPUT CORD (A)
* Voltage is limited to the specifications of the
input modules in use
CONNECTION CORD L9790
Recommended
Flexible φ 4.1 mm (0.16 in) thin dia. cable allowing
for up to 600 V input, 1.8 m (5.91 ft) length * The
end clip is sold separately.
High-Precision pull-through current sensors, observe
waveforms from DC to distorted AC
AC/DC CURRENT SENSOR CT6862, 1 MHz band width, 50 A
AC/DC CURRENT SENSOR CT6863, 500 kHz band width, 200 A
ALLIGATOR CLIP L9790-01
Observe waveforms from DC to distorted AC
AC/DC CURRENT PROBE CT6841, 1 MHz band width, 20 A
AC/DC CURRENT PROBE CT6843, 500 kHz band width, 200 A
GRABBER CLIP 9790-02
Observe waveforms of distorted AC (cannot for DC)
CLAMP ON SENSOR 9272-10, 100 kHz band width, 200 A
Red/black set attaches to the ends of the cables
L9790
Red/black set attaches to the ends of the cables
L9790 * When this clip is attached to the end of
the L9790, input is limited to CAT II 300 V. Red/
black set.
CONTACT PIN 9790-03
Red/black set attaches to the ends of the cables
L9790
INPUT CORD (B)
Up to 200 A (High precision)
* Voltage is limited to the specifications of the
input modules in use
CONNECTION CORD L9198
φ 5.0 mm (0.20 in) dia., cable allowing for up to
300 V input, 1.7 m (5.58 ft) length, small alligator
clip
CONNECTION CORD L9197
Up to 1000 A (High precision)
High-Precision pull-through current sensors, observe
waveforms from DC to distorted AC
AC/DC CURRENT SENSOR 9709, 100 kHz band width, 500 A
Observe waveforms from DC to distorted AC
AC/DC CURRENT PROBE CT6844, 200 kHz band width, 500 A
AC/DC CURRENT PROBE CT6845, 100 kHz band width, 500 A
AC/DC CURRENT PROBE CT6846, 20 kHz band width, 1000 A
CLAMP ON PROBE 3276
GRABBER CLIP 9243
CLAMP ON PROBE 3274
Wide DC to 10 MHz bandwidth, up to 150 A rms
CLAMP ON PROBE 3275
* This probe does not expand the maximum rated
voltage above ground of an isolated input.
Up to 4 current probes connectable
DC, 1 Hz to 10 kHz (-3dB), 600 A, 1 mV/A output
AC/DC CURRENT SENSOR CT7642, (Auto zero
CT7742)
DC, 1 Hz to 10 kHz (-3dB), 2000 A, 1 mV/A output
* Voltage to ground is within this product’s specifications, separate power source is also required.
DISPLAY UNIT CM7290
Power supply for the CT7600/7700 series single drive, Measure,
Display, Signal output function
DIFFERENTIAL PROBE P9000-01
(Wave Only) For Memory HiCorder,
1 kV AC, DC, Frequency band: 100 kHz
100 to 240 V AC
POWER SUPPLY 3269
AC/DC CURRENT SENSOR CT7636, (Auto zero
CT7736)
Max. rated voltage to earth is same as for
input module, max. input voltage 5 kV peak (up
to 1MHz), 1.5 m (4.92 ft) length
AC ADAPTER Z1008
Single current probe connectable (2 units
possible depending on conditions)
DC, 1 Hz to 10 kHz (-3dB), 100 A, 1 mV/A output
10:1 PROBE 9666
(Switch between Wave/RMS) For Memory
HiCorder, 1 kV AC, DC, Frequency band: 100
kHz
Power supply * Necessary for use high speed current probes
POWER SUPPLY 3272
100 A to 2000 A (Medium speed) A
AC/DC CURRENT SENSOR CT7631, (Auto zero
CT7731)
Max. rated voltage to earth is same as for
input module, max. input voltage 1 kV rms (up
to 500 kHz), 1.5 m (4.92 ft) length
DIFFERENTIAL PROBE P9000-02
Cord has insulated BNC connectors at both ends,
signal output use, 1.6 m (5.25 ft) length
Wide DC to 100 MHz bandwidth, 10 mA-class to 30 Arms
10:1 PROBE 9665
INPUT CORD (D)
CONNECTION CORD L9217
Wide DC to 50 MHz bandwidth, 10 mA-class to 30 Arms
Wide DC to 2 MHz bandwidth, up to 500 A rms
INPUT CORD (C)
Power supply for current sensors when used alone
10 mA class to 500 A (High speed)
CLAMP ON PROBE 3273-50
φ 5.0 mm (0.20 in) dia., cable allowing for up to
600 V input, 1.8 m (5.91 ft) length, detachable
large alligator clips are bundled
Attaches to the tip of the banana plug cable, CAT
III 1000 V, 196 mm (7.72 in) length
Power supply * Not necessary when using Current Unit 8971.
SENSOR UNIT 9555-10
Custom cable
*For P9000. Inquire with your
local Hioki distributor.
(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable
100 A to 2000 A (Medium speed) B
CLAMP ON AC/DC SENSOR CT9691-90
DC to 10 kHz (-3dB), 100 A, Output 0.1 V/f.s. Set model with the CT6590
CLAMP ON AC/DC SENSOR CT9692-90
DC to 20 kHz (-3dB), 200 A, Output 0.2 V/f.s. Set model with the CT6590
CLAMP ON AC/DC SENSOR CT9693-90
DC to 15 kHz (-3dB), 2000 A, Output 0.2 V/f.s. Set model with the CT6590
INPUT CORD (E)
* Voltage to ground is within this product’s specifications, separate power source is also required.
500 A to 5000 A *For commercial power lines, 50/60 Hz
CLAMP ON PROBE 9018-50
DIFFERENTIAL PROBE 9322
1 kV AC, 2 kV DC, Frequency band: 10 MHz
Good phase characteristics, Frequency characteristics: 40 Hz to 3 kHz, 10
to 500 A AC range, output 0.2 V AC f.s.
CLAMP ON PROBE 9132-50
AC ADAPTER 9418-15
Frequency characteristics: 40 Hz to 1 kHz, 20 to 1000 A AC range, output
0.2 V AC f.s.
100 to 240 V AC
Other options for Input
INPUT CORD (F)
* Voltage input via banana terminals limited by the
voltage specifications of the respective input unit.
CONNECTION CABLE L4940
Banana plug - banana plug, Cord length: 1.5 m (4.92 ft)
EXTENSION CABLE L4931
Extend the length of banana plug cables, Cable length:
1.5 m (4.92 ft)
ALLIGATOR CLIP L4935
Attach to the tip of banana plug cables, CAT IV 600 V,
CAT III 1000 V
BUS BAR CLIP L4936
CONNECTION CORD L9217
Cord has insulated BNC connectors at both
ends, signal output use, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
Receiving side banana terminal, output BNC
terminal
CONNECTION CORD 9165
Metallic BNC at both ends, for metallic BNC
terminals, 1.5 m (4.92 ft) , not CE marked
CONVERSIONCABLE 9318
For connecting CT6841/43 and similar
probes to 8971/40/51.
GRABBER CLIP 9243
Attach to the tip of banana plug cables, red/black set,
full length: 196mm (7.72 in), CAT III 1000 V
Cable length: 70 cm, tips interchangeable with
a pin test lead or alligator clip, maximum input
voltage: CAT IV 600 V, CAT III 1000 V
10 mA range/10 μA resolution to 200 A range, with monitor/analog
output 1 V f.s.
OUTPUT CORD 9094
3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
CONVERSION ADAPTER 9199
Receiving side banana, output BNC terminal
AC ADAPTER 9445-02
For EU 100 to 240 V AC, 9 V/ 1 A
Attach to the tip of banana plug cables,CAT III 1000 V
TEST LEAD L2200
CLAMP ON LEAK HiTESTER 3283
AC ADAPTER 9445-03
MAGNETIC ADAPTER L4937
*For the MR8990 *Voltage is limited to the
specifications of the input modules in use
LEAK CURRENT *For commercial power lines, 50/60 Hz
For USA, 100 to 240 V AC, 9 V/ 1 A
Attach to the tip of banana plug cables, CAT III 600 V
INPUT CORD (G)
AC FLEXIBLE CURRENT SENSOR CT9667-01/-02/-03
10 Hz to 20 kHz, 5000 A/ 500 A AC, 500 mV/f.s. output, φ 100 to 254 mm
(3.94 to 10.00 in), 3 loop diameters
Temperature sensor
THERMOCOUPLE
*For reference only. Please purchase
locally.
NEW
ARBITRARY WAVEFORM
GENERATOR UNIT U8793
Generate and record
in a single unit
2 channels, SMB terminals
2 types of output cables (sold separately) ►
Anomaly Simulation
Reproduce and output the observed waveforms
without modification. When resolving problems
observed during research or development, you can
reproduce such problems for efficient testing.
Recommended units
Record anomalous
waveforms
ARBITRARY WAVEFORM
GENERATOR UNIT
U8793
ANALOG UNIT
8966
●
HIGH RESOLUTION
UNIT
8968
Max. 15 V output + amplifier
Reproduce and output
anomalous waveforms
Create power supply waveforms such as power supply dips, instantaneous
interruptions, and voltage fluctuations for immunity tests to regulate malfunctions in
equipment caused by power supply harmonics to perform evaluation testing.
Replace multiple DMMs with a single unit
Save space by replacing multiple desktop DMM units with a single MEMORY HiCORDER.
This eliminates the need to control multiple units and simplifies your system.
Recommended
units
DIGITAL VOLTMETER UNIT
MR8990
Install up to 16 DVM Units to
expand up to 32 channels
2 channels, banana input terminal
High precision, high resolution
DIGITAL VOLTMETER UNIT MR8990
Fine precision and resolution
Measurement range
Proprietary specifications for DC voltage
measurements
Measure minute fluctuations in sensor output for
automobiles or voltage fluctuations in batteries with
high precision and at high resolution. The maximum
voltage that you can input is 500 V DC. Another
feature is high input resistance.
Effective input
range
(Guaranteed
measurement
accuracy range)
Max.
resolution
5 mV/div
(f.s. = 100 mV)
-120 mV to 120 mV
50 mV/div
(f.s. = 1000 mV)
-1200 mV to 1200 mV
1 μV
-12 V to 12 V
10 μV
500 mV/div (f.s. = 10 V)
0.1 μV
5 V/div
(f.s. = 100 V)
-120 V to 120 V
100 μV
50 V/div
(f.s. = 1000 V)
- 500 V to 500 V
1 mV
Input
resistance
100 MΩ
or more
Measurement accuracy
NPLC:
less than 1
NPLC:
1 or more
±0.01% rdg.
±0.015% f.s.
±0.01% rdg.
±0.01% f.s.
±0.01% rdg.
±0.0025% f.s.
10 MΩ
±5%
±0.025% rdg.
±0.0025% f.s.
● 6.5-digit display (Resolution: 0.1 μV), 24-bit high resolution
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) SALES & TRADING CO., LTD.
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: info@hioki.com.cn
DISTRIBUTED BY
HIOKI SINGAPORE PTE. LTD.
TEL +65-6634-7677 FAX +65-6634-7477
HEADQUARTERS
E-mail: info-sg@hioki.com.sg
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568
HIOKI KOREA CO., LTD.
http://www.hioki.com / E-mail: os-com@hioki.co.jp TEL +82-2-2183-8847 FAX +82-2-2183-3360
E-mail: info-kr@hioki.co.jp
HIOKI USA CORPORATION
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: hioki@hiokiusa.com
All information correct as of May 20, 2016. All specifications are subject to change without notice.
MR8827E4-65E
Printed in Japan
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising