Rack Power Distribution Unit - AP7551
Rack Power Distribution Unit—AP7551
Description
This booklet provides information on installing and operating the
AP7551, a single-phase Rack Power Distribution Unit (PDU).
20 IEC-320-C13; 4 IEC-320-C19 outlets
IEC 309 plug
Inventory
Translations
Quantity
Item
2
Cord retention tray (with 8 flat-head screws
and 24 wire ties)
1
Basic and Metered PDU Utility CD
1
Warranty registration card
This manual is available in English on the enclosed CD.
Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM
verfügbar.
Ce manuel est disponible en français sur le CD-ROM ci-inclus.
Questo manuale è disponibile in italiano nel CD-ROM allegato.
ИНСТРУКЦИЯ ПО ИСПОЛЬЗОВАНИЮ НА РУССКОМ ЯЗЫКЕ ПРИЛАГАЕТСЯ НА
ДИСКЕ (CD).
Instrukcja Obslugi w jêzyku polskim jest dostêpna na CD.
Este manual está disponible en español en el CD-ROM adjunto.
This manual is available in Turkish on the enclosed CD.
Receiving inspection
Please recycle
Inspect the package and contents for shipping damage, and make sure
that all parts were sent. Report any damage immediately to the shipping
agent, and report missing contents, damage, or other problems
immediately to APC or your APC reseller.
The shipping materials are recyclable. Please save them for
later use, or dispose of them appropriately.
InfraStruXure certified
This product is certified for use in InfraStruXure systems. See the
InfraStruXure Manager’s configuration instructions included with your
system.
2
Rack Power Distribution Unit — AP7551
How to Install the PDU
Attach the cord
retention trays
Attach the cord retention trays to the PDU, using four flat-head screws
(provided) per tray.
Attach cords to the tray
Attach a cord to the tray by looping the cord and securing it to the tray,
using a wire tie (provided).
Each cord must be secured to the tray so that you can
unplug it from the PDU without removing the wire tie.
Note
Mounting options
Install the PDU in the rear of the NetShelter VX Enclosure, in the cable
channel directly behind the rear vertical mounting rails. You can install
the PDU in one of two ways: using toolless mounting pegs (provided) or
the mounting brackets (sold separately).
You can order a rack-mount bracket kit from APC
(AR8116BLK).
Note
Rack Power Distribution Unit — AP7551
3
How to Install the PDU
Toolless mounting
1. Slide the mounting pegs into the holes located in the channel in the
rear panel of the enclosure.
2. Snap the PDU into place by pushing it downward until it locks into
position.
You can mount two PDUs on one side of the enclosure by
using the toolless mounting method.
Note
4
Rack Power Distribution Unit — AP7551
How to Install the PDU
Bracket-mounting
You can order a rack-mount bracket kit from APC (AR8116BLK). The
brackets attach to the PDU in either of two directions, shown in the
figures in step 1. Consider the orientation of the PDU in the enclosure
before attaching the brackets. A recessed orientation allows the PDU to
be mounted flush with the enclosure; a raised orientation allows you to
route cables through the channel (see the figures in step 2).
1. Attach two brackets to the rear of the PDU, using two pan-head
screws (provided in the bracket kit) for each bracket.
– Recessed orientation
– Raised orientation
You can mount two PDUs on one side of the enclosure by
using the raised orientation.
Note
Rack Power Distribution Unit — AP7551
5
How to Install the PDU
2. Insert mounting screws (provided with the bracket kit) in the top
and bottom positions in the channel where the brackets align with
the holes. Tighten the screws to secure the PDU to the enclosure.
– Recessed orientation
– Raised orientation
6
Rack Power Distribution Unit — AP7551
Specifications
AP7551
Electrical
Nominal input voltage
230V
Acceptable input voltage
± 10% Nominal input voltage
Input frequency
47–63 Hz
Input connectors
IEC 309 plug
Output connectors
20 IEC–320–C13; 4 IEC–320–C19 outlets
Maximum total current draw
16 A
Physical
Size (H × W × D)
63.75 ×2.19×1.73 in
(161.92 ×5.56×4.39 cm)
Weight
10.7 lb (4.85 kg)
Shipping weight
12.7 lb (5.76 kg)
Environmental
Elevation (above MSL)
Operating
Storage
0–15,000 ft (0–4500 m)
0–50,000 ft (0–15 000 m)
Temperature
Operating
Storage
0 to 45° C (32 to 115° F)
–25 to 65° C (–13 to 149°F)
Humidity
Operating
Storage
5–95% RH Non-condensing
5–95% RH Non-condensing
Approvals
Safety verification
VDE 0805, CE, EN 60950, IEC 60950
Rack Power Distribution Unit — AP7551
7
Warranty and Service
Limited warranty
APC warrants the PDU to be free from defects in materials and
workmanship for a period of two years from the date of purchase. Its
obligation under this warranty is limited to repairing or replacing, at its
own sole option, any such defective products. This warranty does not
apply to equipment that has been damaged by accident, negligence, or
misapplication or has been altered or modified in any way. This
warranty applies only to the original purchaser.
Warranty limitations
Except as provided herein, APC makes no warranties, express or
implied, including warranties of merchantability and fitness for a
particular purpose. Some jurisdictions do not permit limitation or
exclusion of implied warranties; therefore, the aforesaid limitation(s) or
exclusion(s) may not apply to the purchaser.
Except as provided above, in no event will APC be liable for direct,
indirect, special, incidental, or consequential damages arising out of
the use of this product, even if advised of the possibility of such
damage.
Specifically, APC is not liable for any costs, such as lost profits or
revenue, loss of equipment, loss of use of equipment, loss of software,
loss of data, costs of substitutes, claims by third parties, or otherwise.
This warranty gives you specific legal rights and you may also have
other rights, which vary according to jurisdiction.
Obtaining service
To obtain support for problems with your PDU:
0
1. Note the serial number and date of purchase. The serial number is
located on the bottom of the PDU.
2. Contact Customer Support at a phone number located on the back
cover. A technician will try to help you solve the problem by
phone.
3. If you must return the product, the technician will give you a return
material authorization (RMA) number. If the warranty expired, you
will be charged for repair or replacement.
4. Pack the unit carefully. The warranty does not cover damage
sustained in transit. Enclose a letter with your name, address, RMA
number and daytime phone number; a copy of the sales receipt;
and a check as payment, if applicable.
5. Mark the RMA number clearly on the outside of the shipping
carton.
6. Ship by insured, prepaid carrier to the address provided by the
Customer Support technician.
8
Rack Power Distribution Unit — AP7551
Life-Support Policy
General policy
American Power Conversion (APC) does not recommend the use of any
of its products in the following situations:
• In life-support applications where failure or malfunction of the
APC product can be reasonably expected to cause failure of the
life-support device or to affect significantly its safety or
effectiveness.
• In direct patient care.
APC will not knowingly sell its products for use in such applications
unless it receives in writing assurances satisfactory to APC that (a) the
risks of injury or damage have been minimized, (b) the customer
assumes all such risks, and (c) the liability of American Power
Conversion is adequately protected under the circumstances.
a
Examples of life-support
devices
The term life-support device includes but is not limited to neonatal
oxygen analyzers, nerve stimulators (whether used for anesthesia, pain
relief, or other purposes), autotransfusion devices, blood pumps,
defibrillators, arrhythmia detectors and alarms, pacemakers,
hemodialysis systems, peritoneal dialysis systems, neonatal ventilator
incubators, ventilators (for adults and infants), anesthesia ventilators,
infusion pumps, and any other devices designated as “critical” by the
U.S. FDA.
Hospital-grade wiring devices and leakage current protection may be
ordered as options on many APC UPS systems. APC does not claim that
units with these modifications are certified or listed as hospital-grade by
APC or any other organization. Therefore these units do not meet the
requirements for use in direct patient care.
Rack Power Distribution Unit — AP7551
9
APC Worldwide Customer Support
Customer support for this or any other APC product is available at no charge in any of the following ways:
• Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC
Knowledge Base, and to submit customer support requests.
– www.apc.com (Corporate Headquarters)
Connect to localized APC Web sites for specific countries, each of which provides customer support
information.
– www.apc.com/support/
Global support with FAQs, knowledge base, and e-support.
• Contact an APC Customer Support center by telephone or e-mail.
– Regional centers:
APC headquarters U.S., Canada
(1)(800)800-4272 (toll free)
Latin America
(1)(401)789-5735 (USA)
Europe, Middle East, Africa
(353)(91)702020 (Ireland)
Japan
(0) 35434-2021
– Local, country-specific centers: go to www.apc.com/support/contact for contact information.
Contact the APC representative or other distributor from whom you purchased your APC product for information on
how to obtain local customer support.
Entire contents copyright © 2003 American Power Conversion. All rights reserved.
Reproduction in whole or in part without permission is prohibited. APC, the APC logo,
InfraStruXure, and NetShelter are trademarks of American Power Conversion Corporation and
may be registered in some jurisdictions. All other trademarks, product names, and corporate
names are the property of their respective owners and are used for informational purposes only.
990-1419
03/2003
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising