ACTpro 120e.indd

ACTpro 120e.indd
pro
ACTpro 120e Single Door Station
with 12V DC 2A power supply
Operating and
Installation Instructions
ACT Product Code: ACTpro 120e
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e PSU Installation Guide
The ACTpro 120e is a single door station with an integrated 12V DC 2A power supply. It
expands any of the existing ACTpro controllers (ACTpro 4000, 4200, 1520e, 1500e) by
one door.
The 2A output current is used to power
the door station and supply the battery
recharge current. 500mA is reserved for
battery recharge and to power the door
station. Therefore 1.5A is available to power
readers and the lock.
See “Installation Instructions” on page 6.
Example: Power budget of a typical single door read in/out installation.
Total Current Available
2000mA
ACT Door Station and Battery Recharge
500mA
ACT Reader X 2
200mA
Typical Mag Lock
800mA
Total Consumption
1500mA
Spare Capacity
500mA
Electrical Specification
Input Voltage
230VAC +/- 10%
Frequency
47-53Hz
Input Fuse
625mA 250V anti-surge fuse
Output Voltage
13.65V (+/-5%)
Max Load
2A @ 25°C
Electronic Output Fuse
Yes
Battery Current
~0.5A for a battery discharged to ~10V.
Battery Protections
Deep Discharge/Over Charge/Reverse Polarity
Operating Temperature
-10°C to +50°C
1
BN
R
G
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
For Wiegand readers, wire the
DATA 0 of the exit reader to SENSE
on the ACTpro 100e.
Max length 100m with 12V DC
Cable: 8 Core Screened
Belden 9504 or equivalent
Normally
Open
From Previous
Door Station/Controller
RED
GREEN
DATA
+12V
OV
SENSE
CLOCK
AUX RELAY MAIN RELAY
EXIT READERS
For Clock & Data readers, wire
exit readers in parallel but leave
the sense line unconnected.
ACT READER WIRE
COLOUR CODING
Y
BK
B
W
Normally
Closed
RS485
To Next
Door Station
12V
Diagram shows normally energised Magnetic Lock
IMPORTANT:
Place varistor across all lock terminals
1
0V
2
ON
120e
WIRING DIAGRAM
DOORS NETWORK
A
B
0V
3
4
5
6
7
8
DIP
Normally Closed
Break Glass Monitoring
Please Note:
If the Mains Present, Door Contact or
Break Glass Inputs are not used, they
should be linked to 0V or disabled via
software.
0V
+12V
DOOR
NETWORKS
MAINS
PRESENT
PUSH TO EXIT
OP3
OP2
0V
AUX I
DC
PB
NC
C
NO
NC
C
NO
B/GL
TAMP
DOOR
CONTACT
C
NO
NC
C
NO
NC
POLE A POLE B
BREAK GLASS UNIT
(Double Pole)
0V PSU
The unit will beep after 3 seconds.
The unit is now defaulted.
To do this, power the unit up with
ALL 8 DIP switches in OFF position.
FACTORY DEFAULT
This unit should be reset to its
factory default condition before
installation.
Red Fault LED illuminates on:
1. Tamper
2. Break Glass
3. Comms Offline
4. Mains Fault
5. Voltage Low
6. Current Limiting Fuse (500mA)
The Blue Comms OK LED is on while
ACTpro 120e is communicating with
the controller.
ACTpro 120e PSU Operating and Installation Manual
2
ACTpro 120e PSU Operating and Installation Manual
DIP Switch Addressing:
Door 1 is reserved for the ACTpro 1520e/1500e controller
Door 1 & 2 are reserved for all other ACTpro controllers
(ACTpro 4200, 4000, 3200, 3000, 2000)
Required
Address
3
01
02
03
04
05
06
07
01
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
02
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
03
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
04
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
05
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
06
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
07
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
08
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
09
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
10
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
11
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
12
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
13
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
14
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
15
OFF
OFF
OFF
OFF
ON
ON
ON
ON
16
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
17
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
18
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
19
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
20
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
21
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
22
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
23
OFF
OFF
OFF
ON
OFF
ON
ON
ON
24
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
25
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
26
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
27
OFF
OFF
OFF
ON
ON
OFF
ON
ON
28
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
29
OFF
OFF
OFF
ON
ON
ON
OFF
ON
30
OFF
OFF
OFF
ON
ON
ON
ON
OFF
31
OFF
OFF
OFF
ON
ON
ON
ON
ON
32
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
08
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
Wiring of entry & exit readers.
Entry Reader
ACTpro 1050e
Pin & Proximity Reader
SENSE
CLOCK
Exit Reader
(Do not connect to SENSE)
ACTpro 1030e
Proximity Reader
DATA
+12V
OV
RED
GREEN
Reader Recommended Controller
Terminal wiring colour
input Pin
Block
Signal information
SENSE
White
SENSE
For Entry readers connect the reader SENSE cable or
terminal to the SENSE input pin.
For Exit readers, do not use this input.
CLOCKGreen
CLOCK
This is the clock or strobe signal input on the ACTpro 120e. Connect the reader CLOCK cable or terminal on the reader to CLOCK input pin.
DATA
Blue
DATA
This is the Data input.
Connect the reader DATA cable or terminal on the reader
to DATA input pin.
+12V
Red
+12V
Positive +12V DC Supply voltage for the reader.
0V
Black
0V
0V Supply Voltage for the reader.
RED
Brown
RED
Red LED control output from the ACTpro 120e.
Connect the reader brown cable to the terminal marked
RED on the door station.
GREEN
Yellow
GREEN
Green LED control output from the ACTpro 120e.
Connect the reader green cable or terminal marked
GREEN on the ACTpro Door Station.
For Wiegand Entry Readers wire D0 to DATA Pin on ACTpro Door Station and D1 to
CLOCK pin on ACTpro Door Station.
For Wiegand Exit readers wire the D0 of the exit reader to SENSE pin on ACTpro Door
Stationand D1 to CLOCK pin on ACTpro Door Station.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
4
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e Door Station Status Indicators
Blue: Power
This indicates that the
ACTpro 120e has power.
!
Blue: Communications
Constant illumination indicates
that the door station is online.
!
!
Red: Fault
This illuminates to indicate a fault on the system.
Possible causes are:
1.
Tamper open: Door station housing is not closed.
2.
Break Glass: The fault LED will illuminate if the connected Emergency break
glass switch is activated.
3.
Comms Offline: Door station is offline.
4.
Mains Fault: ACTpro 100e Door Station will accept a mains present signal from a PSU (pre-wired on ACTpro 120e). This is wired into MAINS PRESENT input on the PCB. When the PSU has no mains supply the fault is active.
5.
Low Supply Voltage: When voltage to the +12V terminal is less than +9V.
6.
Fuse Blown: The +12V output on the READER terminals is current limited to provide
short circuit protection. The Fault LED will illuminate if too much current is drawn
from this connection.
5
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
LED indicators
Green - AC OK
Indicates that the AC Mains is within specification.
Amber – ON BATTERY
Indicates that the battery is supplying the output voltage.
Red - FUSE FAULT
Indicates electronic output shutdown fuse is active and
that no power is being supplied to the load.
The maximum current that the PSU can
guarantee is 1.5A plus 0.5A for battery
charging. Beyond this the fuse will trip
and the LED will stay on until the load is
fully disconnected.
Once the load has been disconnected,
remove devices to reduce the current
demand below 1.5A.
It is important to calculate the power
budget adequately. Please refer to the
section on the following page titled
‘Power Budget’ for more information.
Installation Instructions
The ACTpro 120e Door Station is for indoor installation only and must be installed as
permanently connected equipment.
An external mains disconnect device must be fitted. Before installation ensure that the
mains supply to the ACTpro 120e Door Station is disconnected.
Mains power should be connected to ACTpro 120e Door Station by a licensed electrician
in accordance with local/national codes.
Mounting
Mount the ACTpro 120e Door Station directly on to the wall with the supplied screws.
The keyed mounting hole should be screwed first to the wall to aid the mounting.
The unit should be installed in a ventilated area that allows for accessibility after
installation.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
6
ACTpro 120e PSU Operating and Installation Manual
Mains Power up
Attach a correctly rated mains cable and fasten using
the cable tie.
Use an approved external mains disconnect device.
Apply mains power. Check the ‘AC OK’ LED is on
and measure the +12V output.
L
N
Battery insertion
Disconnect the mains.
Ensure the battery has enough charge to supply the load.
Connect the red battery lead to the “+” battery terminal and the black lead to the “–”
terminal.
Apply the mains power and check the “AC OK” Green LED is illuminated.
Remove the mains power and check that “ON BATTERY” Amber LED is illuminated.
If the Amber led is illuminated the battery is now supplying the output.
Re-apply the mains power. The “AC OK” Led will illuminate and the “ON BATTERY” LED
will extinguish.
Power Budget
The PSU can supply up to 2A; 0.5A reserved for battery recharging and to power the door
station. 1.5A remains to power the locks and readers.
A complete access control system will require readers and a lock mechanism all of which
will require power.
The following table should be used for calculating the power budget.
ACTpro reader (1030/1040/1050/1060)
100mA
ACTPro MIFARE reader (1030/1040/1050)
100mA
Typical Mag Lock (consult your supplier)
800mA
7
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
ACTpro 120e PSU Operating and Installation Manual
ACTpro 120e Features and Specification:
Features:
Main relay and AUX relay
Supports all ACTpro readers (RFID 125KHz, MIFARE Classic, DESFire EV1)
Break glass monitoring
Voltage monitoring
Supports Clock and Data or Wiegand readers
Multiple entry & exit readers
Reader current limiting / short circuit protection
Request to exit
Door monitoring
Tamper and mains present monitoring
Status LED’s
Interlocking
Technical Details:
Relay contact rating
Main relay 5A / 50 Vac, AUX relay 1A / 50 Vac
Indoor use only
M
Compatible with all ACTpro Controllers
ACTpro 4200, 4000, 3200, 3000, 2000,1500e, 1520e
PSU Output Voltage:
12V DC
The power supply provides two 12V outputs. One pre-wired to power
the ACTpro Door station. Second is available to power locks.
The full load current shared between the two outputs, ACT recommend
that a maximum of 1.5A is used to power locks and readers. The
remaining 0.5A is used by the door station and battery charging.
Total current from both outputs must not exceed 2A.
Monitoring:
Mains present
Output Voltage
Tamper
The PSU MAINS PRESENT output is pre-wired to the MAINS PRESENT
input of the ACTpro 120e door station.
The PSU output voltage level is reported to the ACT Enterprise software and on the web browser.
The enclosure lid is tamper monitored.
Note: All faults including Mains Present and Tamper are reported on ACT Enterprise and via the web browser on the ACTpro 1520e controller.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
8
ACTpro 120e PSU Operating and Installation Manual
Push Button (PB)
PUSH TO EXIT
Push button is connected between PB input and 0V. When
push button is pressed the main relay is activated for the
configured time.
NC C NO
OP3
OP2
0V
AUX I
DC
PB
Push button is also referred to as Exit Button, Egress Button,
Request To Exit.
DOOR CONTACT
Door Contact (DC)
9
NC
C
NO
MAGNETIC LOCK
0V
EMERGENCY
DOOR RELEASE
NO C NC
MAINS PRESENT
BREAK GLASS
TAMP
BREAK GLASS
MONITORING
0V
+12V
When the Break Glass is not activated the
B/GL input pin is held low at 0V. When the
Break Glass device is activated the B/GL
input pin will lose the 0V (goes high) and
report a Break Glass event. The lock should
be wired such that when the break glass is
activated power to the lock is removed.
NC
C
NO
Relay
Break Glass Monitoring only
The break glass monitoring features only
monitors the break glass status and does
not remove power from the lock. ACT
assumes a double pole break glass unit is
used, one pole to disrupt the power to the
lock the second pole for monitoring.
AUX I
DC
PB
OP3
OP2
0V
Connect door contact between DC input and 0V.
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
12V
ACTpro 120e PSU Operating and Installation Manual
Ordering Information:
ACT Product Code
Product description
Controller
ACTpro 1520e
controller with integrated 12V DC 2A power supply
ACTpro 1500e
Single door IP controller expandable to 32 doors with ACTpro door stations
ACTpro 100e
Single door station
ACTpro 120e
ACTpro 100e door stations with integrated 12V DC 2A power supply
Readers
ACT RFID
ACTpro 1030e
ACT RFID slimline, proximity reader, IP67
ACTpro 1040e
ACT RFID Surface / Flush, proximity reader, IP67
ACTpro 1050e
ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro 1060e
ACT PIN only reader, IP67
ACTpro 1030PM
Panel mount multi-format proximity reader, IP67
ACTpro 1030e VR
Vandal Resistant cover for the ACTpro 1030e
ACTpro MIFARE
ACTpro MIFARE 1030
ACT RFID slimline, proximity reader, IP67
ACTpro MIFARE 1040
ACT RFID Surface / Flush, proximity reader, IP67
ACTpro MIFARE 1050
ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro MIFARE 1030PM
Panel mount multi-format proximity reader, IP67
ACTpro 1030 VR
Vandal Resistant cover for the ACTpro MIFARE 1030
ACTpro DESFire EV1
ACTpro DESFire EV1 1030
ACT RFID slimline, proximity reader, IP67
ACTpro DESFire EV1 1040
ACT RFID Surface / Flush, proximity reader, IP67
ACTpro DESFire EV1 1050
ACT RFID Surface/ Flush, PIN & proximity reader, IP67
ACTpro DESFire EV1 1030PM
Panel mount multi-format proximity reader, IP67
Cards and Fobs
ACT RFID ISO-B
ACT RFID Batch Cards
ACT RFID FOB-B
ACT RFID Batch Fobs
ACTpro MIFARE Card
ACT MIFARE 1K Cards
ACTpro MIFARE Fob
ACT MIFARE 1K Fobs
ACTpro DESFire EV1 Card
ACT DESFire EV1 Cards
Software
ACT Enterprise
PC application software
Accessories
ACT USB Reader
Multi format desktop card reader for ACT Enterprise software
Copyright © 2016 Access Control Technology Ltd. Part No.18-00100 Issue 1.0
10
This manual refers to the ACTpro 120e
door station with an integrated 12V
DC 2A power supply. Access Control
Technology Ltd. reserve the right to
change the contents of this manual and
the system it applies to without prior
notice.
While every effort has been taken
by ACT to ensure the accuracy of
the information contained within
this document, ACT assumes no
responsibility for any errors or
omissions. No liability is assumed
for damages resulting from the use
of information contained within this
document.
Certifications:
The ACTpro 120e Door Station complies
with the following European directives:
Information technology equipment Safety - EN60950-1
EMC Directive - 2004/108/EC
Ireland Office
Unit C1, South City Business Centre,
Tallaght, Dublin 24, Ireland
United Kingdom Office
Unit 601, Birchwood 1, Dewhurst Road,
Birchwood, Warrington, WA3 7GB, UK
Ireland: +353 (0)1 466 2570
UK: +44 (0)161 236 9488
Email: info@act.eu
www.act.eu
Copyright © 2016 Access Control Technology Ltd. Part No. 18-00100 Issue 1.0
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising