LED Driver Compact dimming Driver LCA 44W 700

LED Driver Compact dimming Driver LCA 44W 700
LED Driver
Compact dimming
Driver LCA 44W 700-1050mA flexC PH-C SR ADV
ADVANCED series
Product description
• Dimmable constant current LED Driver (SELV)
• Independent LED Driver with cable clamps
• Selectable output current between 700 and 1,050 mA
• Max. output power 44 W
• Up to 87 % efficiency
• Dimmable via leading edge and trailing edge phase dimmers
• Dimming range 5 to 100 % (depending on dimmer)
• Nominal life-time up to 50,000 h
• For luminaires of protection class I and protection class II
• For luminaires with M and MM as per EN 60598, VDE 0710 and
VDE 0711
• Temperature protection as per EN 61347-2-13 C5e
• 5-year guarantee
Housing properties
• Casing: polycarbonate, white
• Type of protection IP20
Interfaces
• Terminal blocks: 0° screw terminals
Functions
• Overload protection
• Short-circuit protection
• No-load protection
• Overtemperature protection
• Burst protection voltage 1 kV
• Surge protection voltage 1 kV (L to N)
• Surge protection voltage 2 kV (L/N to earth)
È
Standards, page 3
Wiring diagrams and installation examples, page 3
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com
1
LED Driver
Compact dimming
Driver LCA 44W 700-1050mA flexC PH-C SR ADV
ADVANCED series
198 – 264 V
Max. input current (at 230 V, 50 Hz, full load)
0.22 A
Leakage current (at 230 V, 50 Hz, full load)
< 500 µA
Mains frequency
50 Hz
Overvoltage protection
320 V AC, 1 h
Max. input power
53 W
Typ. power consumption (at 230 V, 50 Hz, full load)1
50 W
Min. output power
18 W
Max. output power
44 W
Typ. efficiency (at 230 V / 50 Hz / full load)1
87 %
λ (at 230 V, 50 Hz, full load)1
0.95
Output current
tolerance1 2
tc
13
220 – 240 V
AC voltage range
31
Rated supply voltage
Ø7
2
Technical data
68
34
4,5
119
± 7.5 %
1,500 mA
Max. output voltage
60 V
THD (at 230 V, 50 Hz, full load)
< 15 %
Output LF current ripple (< 120 Hz)
± 30 %
Time to light (at 230 V, 50 Hz, full load)
≤ 0.5 s
Turn off time (at 230 V, 50 Hz, full load)
≤ 0.5 s
Hold on time at power failure (output)
0s
Ambient temperature ta (at life-time 50,000 h)
40 °C
Storage temperature ts
-40 ... +80 °C
Dimensions L x W x H
130 x 68 x 31 mm
10,5
tc
4,5
Max. output current peak3
18,5
130
36
Ordering data
Article
number
Type
Packaging, Packaging, Packaging, Weight per
carton
low volume high volume pc.
LCA 44W 700-1050mA flexC PH-C SR ADV 87500605 30 pc(s).
390 pc(s).
1,950 pc(s).
0.175 kg
Specific technical data
Type
LCA 44W 700-1050mA flexC PH-C SR ADV
1 Test
Min.
forward
voltage
Max.
forward
voltage
Max.
output
power
Typ. power consumption Typ. current consumption Max. casing
Ambient
(at 230 V, 50 Hz,
(at 230 V, 50 Hz,
temperature temperature ta
full load)
full load)
tc
max.
I-out select
700 mA
28 V
42 V
30 W
34 W
150 mA
75 °C
-20 ... +50 °C +LED / –700mA
1,050 mA
28 V
42 V
44 W
50 W
220 mA
80 °C
-20 ... +50 °C +LED / –1050mA
result at 1,050 mA.
2 Output
3 Test
Output
current2
current is mean value.
result at 25 °C.
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com
2
LED Driver
Compact dimming
3.4 Fixing conditions
EN 55015
EN 60598-1
EN 61000-3-2
EN 61000-3-3
EN 61347-1
EN 61347-2-13
EN 61547
EN 62384
Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum
ambient temperature (ta) stated on the device. Minimum distances stated
below are recommendations and depend on the actual luminaire.
Is not suitable for fixing in corner.
Leuchte
Luminaire
>20 mm
1. Standards
>100 mm
>50 mm
1.1 Glow wire test
according to EN 61347-1 with increased temperature of 850 °C passed.
The LED module and all contact points within the wiring must be sufficiently
insulated against 3.5 kV surge voltage.
2. Thermal details and life-time
3.5 Wiring guidelines
2.1 Expected life-time
Expected life-time
Type
Current
LCA 44W 700-1050mA flexC PH-C
SR ADV
700 mA
1,050 mA
ta
tc
Life-time
tc
Life-time
40 °C
65 °C
50,000 h
70 °C
50,000 h
50 °C
75 °C
30,000 h
80 °C
30,000 h
The LED Driver is designed for a life-time stated above under reference
conditions and with a failure probability of less than 10 %.
3.6 Replace LED module
3. Installation / wiring
1. Mains off
2. Remove LED module
3. Wait for 20 seconds
4. Connect LED module again
3.1 Circuit diagram
220–240 V
50 Hz
Hot plug-in or output switching of LEDs is not permitted and may cause a
very high current to the LEDs.
LED
+
–
+LED
–1050mA
–700mA
SEC
L
N
• All connections must be kept as short as possible to ensure good EMI
behaviour.
• Mains leads should be kept apart from LED Driver and other leads
(ideally 5 – 10 cm distance)
• Max. length of output wires is 2 m.
• Incorrect wiring can damage LED modules.
• The wiring must be protected against short circuits to earth
(sharp edged metal parts, metal cable clips, louver, etc.).
• The current selection has to be installed in the accordance to the
requirement of low voltage installation.
Phase cut
dimmer
ô
ô
PRI
LCA ... SR ADV
3.2 Wiring type and cross section
The wiring can be in stranded wires with ferrules or solid.
For perfect function of the cage clamp terminals the strip length should be
4 – 5 mm for the input terminal.
The max. torque at the clamping screw (M3) is 0.2 Nm.
Input / Output terminal
0,5 – 2,5
max. ∅ = 10,0 mm
min. ∅ = 2,2 mm
4–5
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com
3
LED Driver
Compact dimming
4.2 Power factor vs load
3.7 Current select
For 1,050 mA current use this terminals:
0,99
Power factor
L
SEC
LED
+LED
–1050mA
–700mA
+
–
1,00
~
~
N
0,98
0,97
For 700 mA current use this terminals:
0,96
65
L
75
80
85
90
95
100
Load [%]
4.3 Input power vs load
55
~
~
50
Input power [W]
N
70
SEC
LED
+LED
–1050mA
–700mA
+
–
3.8 Mounting of device
Max. torque for fixing: 0.5 Nm/M4
4. Electrical values
45
40
35
30
25
Test at 230 V 50 Hz.
20
65
4.1 Efficiency vs load
90
70
75
80
85
Load [%]
90
95
100
75
80
85
Load [%]
90
95
100
4.4 Input current vs load
240
88
220
87
Input current [mA]
Efficiency [%]
89
86
85
84
83
65
70
75
85
80
Load [%]
90
95
100
200
180
160
140
120
100
65
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com
70
4
LED Driver
Compact dimming
4.5 THD vs load
THD without harmonic < 5 mA (0.6 %):
14
13
THD [%]
12
11
10
9
8
7
6
70
65
75
80
85
Load [%]
90
100
95
4.6 Iout vs Vin
At min. load:
100
90
80
70
60
50
40
Iout [%]
Iout [%]
At full load:
100
90
80
70
60
50
40
30
20
30
20
10
0
10
0
30
20
40
50
60
Vin[%]
70
80
100
90
20
30
40
50
60
Vin[%]
70
80
100
90
Remark: Dimming curve based on DIMMER ELKO 315GLE!
700 mA
1050 mA
4.7 Maximum loading of automatic circuit breakers
Automatic circuit
breaker type
Installation Ø
C10
C13
C16
C20
B10
B13
B16
B20
1.5 mm2
1.5 mm2
1.5 mm2
2.5 mm2
1.5 mm2
1.5 mm2
1.5 mm2
2.5 mm2
Imax
Time
32
41
51
63
32
41
51
63
8A
100 µs
LCA 44W 700-1050mA flexC PH-C SR ADV
Inrush current
4.8 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load)
in %
LCA 44W 700-1050mA flexC PH-C SR ADV
THD
< 15
3.
< 12
5.
<5
7.
<3
9.
<3
11.
<3
Acc. to 6100-3-2. Harmonics < 5 mA or < 0.6 % (whatever is greater) of the input current are
not considered for calculation of THD.
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com
5
LED Driver
Compact dimming
5. Functions
6. Miscellaneous
5.1 Short-circuit behaviour
6.1 Isolation and electric strength testing of luminaires
In case of a short circuit on the output side (LED) the LED Driver protects itslef.
After elimination of the short-circuit fault the LED Driver will recover
automatically.
Electronic devices can be damaged by high voltage. This has to be considered
during the routine testing of the luminaires in production.
5.2 No-load operation
In no-load operation the output voltage will not exceed the specified max.
output voltage.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A,
each luminaire should be submitted to an isolation test with 500 V DC for
1 second. This test voltage should be connected between the interconnected
phase and neutral terminals and the earth terminal.
The isolation resistance must be at least 2 MΩ.
5.3 Overload protection
As an alternative, IEC 60598-1 Annex Q describes a test of the electrical
strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic
devices this test must not be conducted.
If the output voltage range is exceeded the LED Driver will protect itself and
LED may flicker. After elimination of the overload, the nominal operation is
restored automatically.
6.2 Storage conditions
5.4 Over temperature protection
Humidity:
5 % up to max. 85 %,
not condensed
(max. 56 days/year at 85 %)
The LED Driver is protected against temporary thermal overheating.
If the temperature limit is exceeded the output current is reduced to limit tc
at a certain level.
Storage temperature:
-40 °C up to max. +80 °C
The devices have to be within the specified temperature range (ta) before
they can be operated.
6.3 Additional information
Additional technical information at www.tridonic.com → Technical Data
Guarantee conditions at www.tridonic.com → Services
Life-time declarations are informative and represent no warranty claim.
No warranty if device was opened.
Data sheet 07/17-LC456-1
Subject to change without notice.
www.tridonic.com