CATALOGUE 2013 Fire Alarm Systems
C ATA L O G U E 2 0 1 3
Fire Alarm Systems
BELIEVE IN
SUCCESS
The ATEÏS Brand name, for more than three
decades, is synonymous with quality and is
backed with the assurance of Responsibility and
Rapid response-essential in building a strong
Relationship with our clients and customers.
VELOX is the new era by ATEÏS, shall service
the life safety market segment in particular, and
shall have the same commitment to excellence
and customer satisfaction, reflecting the same
quality we are known for by all our global
partners.
Operating from five offices, our engineers
constantly strive for excellence and outstanding
performance. By maintaining its headquarters
in Dubai-UAE, with support offices in Abu
2
Fire Alarm Systems
Dhabi, Qatar, Kingdom of Saudi Arabia, and
India, ATEÏS Middle East is guaranteed to
remain closer to the end user.
We deliver high-end fire alarm & mass
notification systems, background music and
professional audio systems that guarantee
security and protection backed by high fidelity
sound to provide an unbeatable combination of
comfort and peace of mind.
Over decades, VELOX is built on the strong
foundation of research and development in
fire detection and alarm systems technology,
delivered with the highest quality and safety
standards, with the commitment of five years
warranty.
Contents
NEW ERA OF INNOVATION YOU TR UST
4
TYPICAL SYSTEM DIAGRAM
6
INTELLIGENT FIRE ALARM CONTROL PANELS
8
CARDS & ACCESSORIES
10
PROGRAMMING DEVICE
12
CONFIGURATION SOFTWARE
13
INTELLIGENT DET ECTORS WITH ISOLATORS
14
INTELLIGENT DET ECTORS WITHOUT ISOLATORS
15
DECORATIVE SMOKE AND HEAT DETECTORS
16
INTELLIGENT ADDRESSABLE BEAM DETECTOR
17
INTELLIGENT ADDRESSABLE DUCT DETECTOR
18
ADDRESSABLE LOOP POWERED SOUNDER BASE
19
ADDRESSABLE SOUNDER & BEACON
20
INTELLIGENT REMOTE INDICATOR
21
ADDRESSABLE MANUAL CALL POINT
22
SINGLE & MULTIPLE CHANNEL INPUT/OUTPUT MODULES
23
MULTIPLE CHANNEL INPUT/OUTPUT MODULES
24
CUSTOMIZABLE SHOP INTERFACE
25
FIRE TELEPHONE SYSTEM
26
PARTS LIST
28
REFERENCES
31
3
NEW ERA OF
INNOVATION YOU TRUST
VELOX is delivered with intuitive
design, built on the foundation of
innovations and features that our
customers love, and delivered with
unparalleled synergy along with our
leading ATEIS Audio Solutions, that
re- defines the term “integration” in
a new form never recognized before.
A new era of fire detection is born, in many ways
it is the distinction that what our customers
love in our products. The full integration now
is simpler, more essential and certainly more
capable. We believe that VELOX integrated
solution is a new experience that harmoniously
integrates both audio and Fire detection. Our
engineers keeps on re-defining the boundaries
between them to a limit that unlikely you have
ever realized before.
Today, with over a three decades of innovation,
we built a new system with distinctive care and
quality. Our R&D has integrated both acoustics
and fire detection for the first time ever,
synonymously. We believe that the VELOX is
an experience. That experience is refined, and
pushed to the limit to define a new technology
that is simple to commission, easy to install,
and user friendly.
We have set the quality bars high, by choosing
Dubai Silicon Oasis-UAE as the home to
manufacture and design our products. We
comply to ISO 9001 across the manufacturing
and design, resulting in a bespoke and vivid
realization of both acoustics and fire detection
on one platform; thereby, setting a new era in
life safety market segment that has never been
realized before.
4
Fire Alarm Systems
ATEÏS GROUP
W O R L D WI DE
Jumeirah Group selected
the
ATEIS brand as their
preferred vender providing
life safety protection to
their iconic installations
across the UAE.
5
TYPICAL
SYSTEM DIAGRAM
VNB
BUILDING MANAGEMENT
SYSTEM
AUDIO CONTROL
ATEÏS GRAPHIC
COMMAND CENTER
PMIP D
Ethernet over TCP/IP
BAC NET
2 CORE 1.5 MM2 COPPER CABLE
BMS GATEWAY
UP TO
REMOTE CONTROL
TERMINALS
IP GATEWAY
200 PANELS ON THE LOOP
UP TO 1.5 KM
UP TO 1.5 KM
STANDALONE
FIRE PANEL
4 CORE 1MM
TWISTED
DATA CABLE
INTEGRATED FIRE
ALARM PANEL
FIRE ALARM PANEL
WIRELESS
CALL POINT
Beacon
DETECTOR
DETECTOR
WITH SOUNDER
WIRELESS
DETECTOR
500 M
MODULES
WIRELESS
BEACON
DETECTOR
WIRELESS
OUTPUT MODULE
MCP
500 M
SOUNDER FLASHER
WIRELESS
SPEAKER
TCP/IP
TRANSLATOR MODULE
TCP/IP
MCP
WIRELESS
DETECTOR
SOUNDER
ADDRESSABLE
TELEPHONE JACK
WIRELESS
SOUNDER
MINI MODULES
SOUNDER
WIRELESS
INPUT MODULE
UP TO 2 KM
PR
E
M
ORBIT STEERABLE
LINE ARRAY
ST
BASS ARRAY
SY
Fire Alarm Systems
D I O S P EAK ER
6
O -A U
PAVA Rack
ATEIS SECURED AUDIO
NETWORK 48 CHANNELS
PAVA Rack
ATEÏS REMOTE MAINTENANCE
MANAGEMENT CONTROL
BUILDING MANAGEMENT
SYSTEM
VNB
ATEÏS STUDIO
CONTROL CENTER
MUSIC SERVER
IP AUDIO STREAMING
Ethernet over TCP/IP
MODBUS
2 CORE 1.5 MM2 COPPER CABLE
BMS GATEWAY
UP TO 200 PANELS ON THE LOOP
UP TO 1.5 KM
REMOTE CONTROL
TERMINALS
UP TO 1.5 KM
STANDALONE
FIRE PANEL
FIRE ALARM PANEL
WITH SMOKE MANAGEMENT
SYSTEM
FIRE ALARM PANEL
EOL
MCP
DETECTOR
WITH SOUNDER
DETECTOR
EOL
BEAM DETECTOR
SOUNDER
SOUNDER
MODULES
FCU
MODULES
AHU
Shop IFU
EOL
CONTROLLER
MCP
SOUNDER FLASHER
MODULES
TCP/IP
DETECTOR
TCP/IP
EOL
SOUNDER
MCP
DETECTOR
SOUNDER
3008
MODULES
Intelligent Conventional
Fire Alarm Control Panel
SMOKE
EXTRACTING FAN
INDICATOR
ATEIS SECURED AUDIO
NETWORK 48 CHANNELS
PAVA Rack
PAVA Rack
STEERABLE LINE ARRAY
UP TO 2 KM
7
INTELLI GENT
FIRE ALARM CONTROL PANELS
VELOX 4000 fully integrates full audio and fire detection in a seamless synergy that redefines a
new era of fire detection and alarm systems. Fully complying and certified to EN54 part 2 and 4
The VELOX 4000 series is built on decades of innovation
foundation, support from 1 to 8 loops via common plug in
loop driver boards.
Fully integrated with ATEIS legendry public address and
evacuation systems, and can route simultaneously up
to 48 audio channels of sonic audio quality that support
192Kbit/sec of audio resolution. The evacuation network
can sustain up to 8,192 zones of speaker circuits, each of
1000 watt load capability like no other.
The bespoke panel is fully integrated with addressable
fire-man’s telephone communication system, that support
up to 256 circuits, which can drive telephone jacks or
addressable telephone handsets.
The system can handle 240 device per loop, and extend
its loop length up to 2Km over a two core copper cable.
The network can withstand up to 200 fire alarm control
panels on a peer-to-peer communication, and network can
be stretched on a span of 20Km over VELOX redundant
network.
Features
• Compliant with BS EN54 parts 2
&4
• 1, 2, 4 or 8 loop formats
• Up to 240 devices per loop
• Up to 1,000 fire detection zones
• Up to 200,000 devices per
network
• True peer-to-peer networking
• Networkable up to 200 nodes
• Loop length extendable up to 2
km
• Up to 1000 event logs per panel
for diagnosis of fault conditions
• Automatic and manual addressing
features
• Complex ‘Cause & Effect’ programming options
• Dedicated RS232 serial port for
PC or modem connection
• User-friendly menu and navigation
keys
• Multiple language display options
The VELOX 4000 can be delivered with multiple options
of standard or custom made controls and LED indications
to construct an LED mimic panel or smoke management
control, with vivid design that sets a new era of
customization.
TECHNICAL SPECIFICATIONS
NUMBER OF LOOPS
V E L OX 4200
VEL O X 4 4 0 0
VEL O X 4 8 00
1-2. Expandable via individual plug-in loop driver
1-4. Expandable via individual plug-in loop driver
2-8. Expandable via individual plug-in loop driver
LOOP CURRENT
500mA
ON BOARD RELAYS
2 x 1 Amp 30v AC/DC Programmable
ON BOARD POWER SUPPLY
MAINS SUPPLY
BATTERY CAPACITY
CHARGER CURRENT
APPROVALS
8
Fire Alarm Systems
4 Amp high efficiency switched mode
5 Amp high efficiency switched mode
230 V Ac (+10%, -15% tolerance) 50 /60 Hz 1.9 Amp
230 V Ac (+10%, -15% tolerance) 50 /60 Hz 1.7 Amp
24v 18 Ah internal. 24v 48 Ah external
2.0 Amp DDP monitored, temperature compensated integral charger
-
2.2 Amp DDP monitored, temperature compensated integral charger
BS EN54-2 & 4:1998
INTELLIGENT
FIRE ALARM CONTROL PANELS
2 LOOP
V ELO X 4200
•
•
•
•
•
V E LOX 4800
8 LOOP
Up to 50 additional programmable LEDs
•
•
•
•
Up to 8 programmable key switches or
4 plus printer
•
One or two loops
Medium enclosure
Maximum 12Ah internal batteries
•
• Large and Deep enclosure options
Plexi-glass door option
•
•
VELO X 4400
•
Extended enclosure
Maximum 45Ah internal batteries
Up to 200 additional programmable
LEDs,2 x switch cards or mimic
Up to 8 programmable key switches or
4 plus printer
Plexi-glass door and external battery
box option
Options for mimic panel or smoke management system.
MIMIC PANEL S
4 LOOP
•
•
•
•
Two to eight loops
• Simple graphical indication of local
zones
One to four loops
• Programmable mimic driver card and-
Large enclosure
LEDs
Maximum 17Ah internal batteries
• Flexibility in replacing or updating mimic
Up to 200 additional programmable
LEDs
Up to 8 programmable key switches or
4 plus printer
Plexi-glass door option
diagrams or zone layouts
• Supports Dynamix zoning
• Network connection options
• Available in custom sizes A0, A1, A2 or
•
• Deep and Extended enclosure options
• Options for mimic panel or smoke mana-
A3 on request
gement system.
V ELO X 4010 - 4020
V E LOX 2100 - 2200
REMOTE DISPLAY AND CONTROL TERMINALS
ANALOG ADDRESSABLE FIRE ALARM CONTROL PANELS
•
•
•
•
•
•
•
•
•
•
•
•
•
Graphical LCD display
Multiple-language support
Simple user control
Fully on-site programmable
V ELO X 4030 - 4035
One loop or two loop options
All devices are powered form the loop
In-built isolator in each device
20 programmable zonal LED indicators.
4 lines x 40 characters display
1000 events stored in the memory
Day / Night programming functions
Optional TCP/IP connectivity
Small – Medium size installation
4090- 4094 Ran g e
ON-BOA RD AND PORTABLE PRINTERS
•
• Fast and silent operation
• Automatic and on-demand options for
POWER SUPPLY UNITS
In-built battery backup
• Compliant with EN54 part 4
• Available as boxed and un-boxed ver-
printing
• Switched mode power supply (1.5A,
sions
3A, 5A)
• Onboard fault indications
9
CARDS &
ACCESSORIES
NETWORK CARDS
NETWORK CARDS
The 4420 and 4421 network cards allows VELOX 4200
and 4400 fire alarm control panels to be linked with other
similar panels or control and remote terminals on a single
network which can be configured either from the panel or
from a PC.
• True peer to peer network
• Connection of up to 200 panels on a network
• Network devices can be monitored from the control
panel
• Cross-panel reporting and control
• Flexibility in adding and removing control panels and
remote terminals
BMS/GRAPHICS INTERFACE CARD
The 4120 BMS interface card allows integration of fire
alarm control panels and remote terminals with building
management systems (BMS) and graphics PCs.
The interface allows handling of all network traffic and
event prioritization on a PC via an RS232 connection.
• Easy configuration and sector based programming via
software
• Compatible with 3rd party graphics systems
IP INTERFACE CARD
The 4124 IP Gateway Interface Card allows connection of
the 4000 series of fire alarm control panels and its network
to the Internet.
A standard Web browser can be used to monitor the fire
network and the obtain the state of the fire panel network
through visual indications.
•
•
•
•
Configuration over the Internet
Password protection
Event notification via Email
Multiple user permissions (maximum of 2 simultaneous
users)
• Compatible with IE6, IE7, and Firefox 2
BACNET/IP/MODBUS INTEGRATOR
The 4130 integrator provides protocol conversion for
BACNET, IP and MODBUS networks to link the fire detection
and alarm network with third-party building management
systems.
The protocol translator is installed with the 4120 BMS/
graphics interface card to allow external BMS/graphics
systems to issue commands and receive information over
an RS232 bi-directional serial port. Connectivity via IP
allows remote monitoring and programming.
• BACNET/IP or MODBUS/IP protocol conversion
• Provide full control on the network
• up to 400 points control
PERIPHERAL CARD
OUTPUT CARDS
Output cards 4042 and 4048 are 2-way and 8-way relay
output devices fitted as an internal peripheral with the
4000 series of fire alarm control panels.
All outputs can be individually programmed for any specific
function supported by the fire alarm control panel.
The output card provides a cost effective way to program
‘cause and effect’ functions.
10
Fire Alarm Systems
•
•
•
•
8 individually programmable outputs
Fast output response
Cost-effective option to additional hardware
Supports complex cause and effect configurations
INPUT CARD
The 4148 is an 8-way input card fitted as an internal
peripheral with the 4000 series of fire alarm control panels.
All 8 inputs can be individually programmed for any
specific function supported by the fire alarm control panel.
The input card provides a cost effective way to perform
latched or non-latched switching functions such as fire,
fault, alarm, security, disable, evacuate and so on.
• 8 individually programmable inputs with 8 on-board
green LEDs
• Fast input response for class change latching/non-latching
operations
• Easily programmable via on-board keypad or PCs
• Ideal for class change or non-latching operations where
fast input response is essential
PERIPHERAL BUS ADAPTOR CARD
The 4060 peripheral bus adaptor card provides a serial
interface bus for connection of a range of peripheral
modules such as a general routing interface.
• Optically isolated interface
• Compatible with a general routing interface
GENERAL ROUTING INTERFACE CARD
The 4061 general routing interface card is an optional
module that provides fire and fault routing outputs.
Two fire routing outputs are provided to distinguis between
fire alarm signals from a manual call point (MCP) and
automatic detector (AFD), if required.
• Monitored outputs to fire alarm and fault routing circuits
• Circuits are monitored for open and short circuit conditions
PROGRAMMABLE RELAY CARD
The 4064 programmable 4-way relay card is an optional
peripheral unit that provides four individually programmable
relay output circuits.
Up to 16 Cards can be connected to a multi-loop panel
giving a maximum of up to 64 additional local relay outputs.
• Individually programmable outputs
• An Input is provided to monitor the fault output from a
power supply
PROGRAMMABLE SOUNDER CARD
The 4062 programmable 4-way sounder card is an
optional peripheral unit that provides four individually
programmable and monitored sounder output circuits.
Up to 16 cards can be connected to a multi-loop panel
giving a maximum of up to 64 additional local sounder
outputs.
• Outputs are individually programmable and can be
synchronised in pulsing modes
• An Input is provided to monitor the fault output from a
power supply
ZONAL LED INDICATOR
Zonal LED indicators can be mounted on fire alarm control
panels to simultaneously display the status of all zones in
a fire condition.
The LED cards illuminate to indicate the status of zones
ranging from 20-200 zones.
The LED cards are available either as factory fitted to the
panels or as retro fit devices.
A power saving feature minimizes the power drawn from
the fire alarm control panel in the event of a fire.
•
•
•
•
LED cards support 20, 50, 100, and 200 zones
Simultaneous display of all zones in a fire condition
Supports Dynamix zoning
Factory fitted or retro fit options
11
SOUNDER SPLITTER CARD
The 4070 sounder splitter card splits an input from a
standard sounder circuit into 4 monitored outputs. The
circuits are fully monitored for open and short circuits, and
up to 1A is supplied to each circuit.
The 4070 operates in two modes, 1A and 4A splitter. The
modes are selected via jumper switches on the card. In the
1A mode, the sounder splitter card derives power from the
control panel’s auxiliary supply. In the 4A mode, the sounder
splitter card derives power from an external supply.
•
•
•
•
Configuration over the Internet
Password protection
Event notification via Email
Multiple user permissions (maximum of 2 simultaneous
users)
• Compatible with IE6, IE7, and Firefox 2
SOUNDER BOOSTER CARD
The 4072 sounder booster card provides increased
sounder output capability by boosting the input signal from
the sounder circuit of a fire alarm control panel. Up to 4A of
sounder drive current is provided to a single circuit.
• Up to 4A on a single sounder circuit
• Boosted sounder output circuit fully monitored for faults
• On-board LEDs for fault indication
PROGRAMMING DEVICE
LOOP DRIVER AND ANALYZER
The 40710 loop analyser is used to interface the fire
detection and alarm loop with a personal computer to test
and commission the loop without using a fire alarm control
panel.
The 40710 requires an external power supply, which is
connected to its 24V DC terminal. When used in place of the
fire alarm control panel, the 40700 supplies a loop current
of 500mA to power all connected devices for monitoring and
addressing the devices.
The user interface or application software on the PC allows
scanning of the entire loop to identify devices and report openand short-circuit faults, automatic sequential addressing of
devices, and activation of sounders and beacons.
•
•
•
•
•
Loop testing and commissioning via a PC
RS232 port for PC connectivity
Full loop scan for identification of devices and fault reporting
Automatic & Manual addressing of devices
Activation of sounders and beacons (individually or group)
for alarm tests
Monitoring of loop current and device status
•
• Installation map showing physical location of devices on the
loop to match with assigned addresses
• Poll data from devices to obtain their most recent statuses
• Manual activation of output relays
HANDHELD PROGRAMMING UNIT
The handheld 40700 programming unit is used to manually
assign addresses to devices on a fire detection loop.
The programming unit is connected to a device (detector,
sounder, call point, module, etc.) by means of an adaptor or
a special cable.
The device has four keys which allow incrementing or
decrementing the address of a device, store an address
into the memory of a connected device, or simply read the
address of a connected device.
An LCD on the programming unit displays basic information
on a connected device, such as the type of device, production
and test dates, and battery status.
12
Fire Alarm Systems
•
•
•
•
Manual addressing of detectors, sounders, call points, etc.
Menu driven programming device
Reads detector measurements of smoke
Displays manufacturing details of devices
CONFIGURATION
SOFTWARE
Features
• ‘Cause and effect’ programming
• Auto and pre-configured software
options
• Remote dial-up via modem
• User-friendly graphical interface
• User-defined logos for the fire
panel
Configuration Software comprises a range of specific tools allowing users to achieve
what they want quickly and easily, not get bogged down in large, clumsy
and complicated software.
Configuration Software is being continually developed
for the VELOX panel range, adding new features and
performance enhancements. Recently these have
included comprehensive false alarm management
and alarm verification features.
Our position in the global fire industry means we
help guide legislation and can implement software
changes quickly, keeping our customer systems
right up to date. We also listen closely to our
customers and often produce features for specific
client requirements.
The 4500 and 4501 configuration software for
VELOX 4000 panels is compatible with
Windows operating systems and
offers sophisticated ‘cause and
effect’ programming functionalities.
The 4502 remote dial-up software allows communication
with the 4000 series of fire alarm control panel via a modem or direct RS232 connection.
The 4503, 4504, 4505 graphical control software is used to setup a user friendly interface to control fire alarm
equipment by means of graphical maps, images, and text for monitoring installation sites and program graphical
command buttons for enabling or disabling devices.
Conf i g To o l
Termin al Tool
• Full configuration of single panel or
• Full configuration of single panel or
• Automatic design check of site confi-
• Automatic design check of site confi-
• Assistants menu helps the engineer to
• Assistants menu helps the engineer to
• Import, export information and print
• Import, export information and print
network system
network system
guration
guration
easily configure panels
easily configure panels
configuration reports
S er v i ce To o l
configuration reports
Log o Tool
• Extract device information and event
Dra wing Tools
Edit Tools
Communication to Panel
Preview Pan e
• Device History including last activation,
test, enable, disable and date created
•
User defined filters allow data to be
grouped and searched in many different
ways
• View device status, analogue values and
• Allows the installer’s logo to be displayed on the panels graphical LCD
display during Normal Operation
logs from single or multiple panels
ATEiS
ATEiS
Dra wing Ar ea
• Uploads standard bitmap images
• Tool allows creation of logos
• JPG and GIF images can be importedSOFTWARE
drift (contaminated) information
• Network simulation and test feature
• Categorise events and create User defined reports
13
INTELLI GENT
DETECTORS WITH ISOLATORS
ADDRESSABLE SMOKE & HEAT DETECTORS WITH
INBUILT SHORT CIRCUIT ISOLATORS
VELOX addressable detectors employ optical and thermal
detection technologies to sense fire conditions.
The V100, V200, and V350 range of
detectors come with inbuilt short circuit
isolators and a bi-colour (red/green)
LED for 360 visibility.
Combination of optical and thermal
detection in a single detector head
saves costs and spots both slow
smoldering and high energy
flaming fires.
Features
• Compliant with EN54 part 5, 7
and 17
• Inbuilt short-circuit isolators
• Double dust trap and protection
screen prevent entry of dust or
small insects
• Choice of various sensitivity levels
• Automatic & Manual addressing
features
• Responsive to magnet tests
• Tamper detection and fault indication on fire panel
• LED indicator with 360º visibility
• Automatic drift compensation
Up to 240 devices can be
connected on a single loop,
which can extend to 2 km as
per load calculations and cable
selections.
The devices are powered from
the same fire detection loop which
connects the fire alarm control panel,
sounders, beacons, manual call points, etc.
Therefore, additional power supply sources
are not required.
TECHNICAL SPECIFICATIONS
V 10 0
V2 0 0
POWER SUPPLY
AVERAGE STANDBY CURRENT CONSUMPTION
REMOTE OUTPUT MAX CURRENT
CONSUMPTION(EXTERNALLY LIMITED)
OPERATING TEMPERATURE RANGE
HUMIDITY
14
from 18 V (min) to 40 V (max)
70 uA @ 24 V
55 uA @ 24 V
20 mA
-30 °C to +70 °C
95% RH (no condensation)
HEIGHT (STANDARD BASE INCLUDED)
54 mm
DIAMETER
110 mm
WEIGHT (STANDARD BASE INCLUDED)
Fire Alarm Systems
V3 5 0
130 g
INTELLIGENT
DETECTORS WITHOUT ISOLATORS
Features
• Compliant with EN54 part 5 and 7
• Double dust trap and protection
screen prevents entry of dust or
small insects.
• Choice of various sensitivity levels
• Manual addressing via the 40700
handheld programmer
• Up to 240 device per loop
• LED indicator with 360° visibility
• Automatic drift compensation
ADDRESSABLE SMOKE & HEAT DETECTORS WITHOUT
INBUILT SHORT CIRCUIT ISOLATORS
VELOX addressable detectors employ optical and thermal
detection technologies to sense fire conditions
through sophisticated proven intelligent
algorithms.
The LV100, LV200, and LV350 range of
detectors comes with 360° LED, drift
compensation and multiple levels of
alarm sensitivities.
Combination of optical and
thermal detection in a single
detector head saves costs and
spots both slow smoldering and
high energy flaming fires.
Up to 240 devices can be
connected on a single loop,
which can extend up to 2Km of
loop length as per load calculations
and cable selections.
The devices are powered from the same
fire detection loop which connects the
fire alarm control panel, sounders, beacons,
manual call points, etc.
Therefore, additional power supply sources are not required.
TECHNICAL SPECIFICATIONS
LV 10 0
LV2 0 0
POWER SUPPLY
AVERAGE STANDBY CURRENT CONSUMPTION
REMOTE OUTPUT MAX CURRENT
CONSUMPTION(EXTERNALLY LIMITED)
OPERATING TEMPERATURE RANGE
HUMIDITY
from 18 V (min) to 40 V (max)
70 uA @ 24 V
55 uA @ 24 V
20 mA
-30 °C to +70 °C
95% RH (no condensation)
HEIGHT (STANDARD BASE INCLUDED)
54 mm
DIAMETER
110 mm
WEIGHT (STANDARD BASE INCLUDED)
LV3 5 0
130 g
15
DECORATIVE
SMOKE AND HEAT DETECTORS
The VELOX decorative line of smoke and heat detectors
is designed for installations that demand superior
aesthetics and seamless match with interior
architecture and decoration.
Intelligent, conventional, and wireless
detectors are available in a variety
of colors and patterns to blend in
with the wood, metal, and marble
finishes.
Decorative fire alarm detectors
have applications in historical
buildings, places of worship, and
government buildings, where
artistic design of structures is given
as much priority as architecture.
MARBLE
DECOR CODE
CARRARA
11
OBIRHO
12
GREEN ALPES
13
GREEN
14
BLACK
15
CARRARA
11
OBIRHO
12
GREEN ALPES
13
GREEN
14
BLACK
15
GREEN
14
BLACK
15
WOOD
DECOR CODE
METALS
DECOR CODE
PATTERNS
CARRARA
11
OBIRHO
12
To o r d e r a d e c o r a t i v e s e n s o r, a d d t h e c o l o r c o d e t o t h e p r o d u c t o r d e r c o d e .
Fo r e x a m p l e , t o o r d e r a s m o k e d e t e c t o r V 1 0 0 w i t h g r e e n m a r b l e p a t t e r n , r e q u e s t q u o t e f o r V 1 0 0 - 1 4
16
Fire Alarm Systems
INTELLIGENT
ADDRESSABLE BEAM DETECTOR
Features
• Compliant with BS EN54-12 and
UL268
• Ground level control
• Laser assisted alignment
• Building shift compensation
• Auto-optimize beam alignment
• up to 100 meters with additional
accessories
• loop powered with inbuilt isolator
• up to 100 unit on a single loop
now faster and boasting many new
useful features this is by far the best
beam on the market”
We have now designed completely new linear
stepper motors which have resulted in amazingly fast
commissioning and routine maintenance.
At 40 meters under test conditions we are recorded an
auto align times straight out of the box of 3m 02s and
once aligned a routine re-alignment was timed at 1m
07s.
This is class leading performance not only in terms of
speed but also in terms of advanced robust design built
for precise purpose.
Very low power, using only 3.5mA allowing 100
units of 40960 to be connected on the VELOX
loop with in-built isolator
Easy clean lenses the 40960 has been designed
to be easily cleaned with its flat surfaces. Unlike other
beams all the moving optics are safely encased inside the
waterproof enclosure and you are not going to knock the beam out of
alignment.
This means the 40960 can easily be cleaned from ground level using
something like a no-climb pole and suitable attachment.
TECHNICAL SPECIFICATIONS
40960
ELECTRICAL SPECIFICATIONS
Supply Voltage. 10.2 to 30 VDC
Supply Current. 3.5mA (constant current) in all operational states
Constant Current. 17mA (constant current) in fast commissioning
ENVIRONMENTAL SPECIFICATIONS
Temperature. -10°C to +55°C
Humidity. 10 to 95% RH Non-condensing
Protection Index. IP65 when suitably mounted and terminated
OPERATIONAL SPECIFICATIONS
Standard Product 5 to 40 metres
40960-80. Mid-Range Reflector Kit 40 to 80 metres
40960-100. Long Range Reflector Kit 80 to 100 metres
ALARM SENSITIVITY LEVELS
25%(1.25dB) to 50%(3dB) in 1%(0.05dB) increments (default 35% (1.87dB))
17
INTELLI GENT
ADDRESSABLE DUCT DETECTOR
The 40950 series of duct smoke detectors systems
samples air movement in heating and ventilation
ducts by means of an intelligent smoke detector,
housing, and air sampling tube.
An intelligent or conventional optical smoke
or heat detector can be mounted in the
40950 housing.
Air in the ducts is sampled by the
sampling tube/venturi pipe, which
extends from the detector housing into
the duct. The length of the Aluminium
sampling tube can be shortened
according to the diameter of the duct.
However, if the ventilation duct is wider
than 0.6 m, the sampling tube should
penetrate the whole duct.
Features
• Easy mounting of sampling tube
• Single pipe/air sampling system
• Each 40950 system does not
require more than one sampling
tube for supply and return of air
• Duct detectors can operate in air
speeds ranging from 0.5 m/s to
20 m/s
A filter can be attached to the duct detector for
operation in dust environments.
A flexible 40950-BR enables mounting of the 40950
housing on rectangular and circular ducts with
diameters as small as 100 mm.
TECHNICAL SPECIFICATIONS
40950
DIMENSIONS OF DDH:
180x183x235mm
WEIGHT OF DDH:
700g
0.5m/s to 20m/s
AIRFLOW SPEED IN DUCT:
OPERATING VOLTAGE OF BOOSTER FAN:
LENGTHS OF AIR SAMPLING TUBE:
DIAMETER OF DRILL HOLE ON THE DUCT:
APPROVALS:
18
Fire Alarm Systems
24V AC (separate external power supply)
40950-06
40950-15
40950-28
0.6m
1.5m
2.8m
38mm for installation of air sampling tube without the bracket 50mm for installation of air sampling tube with the bracket or booster fan
BS5839 parts 1 and 4 EN54 parts 5 and 7
ADDRESSABLE LOOP POWERED
SOUNDER BASE
Features
•
•
•
•
•
•
•
Compliant to EN54-3
Low current as low as 0.8 mA
World’s slimmest Sounder Base
Powered from the loop
Individually controlled
Does not consume any address
Up to 178 Sounder Base Sensor
on a single loop
The VELOX 40200 is the latest technology
from ATEIS,simple to install and easy
to program, make the VELOX loop
powered sounder the preffered
choice for many applications such
as offices, hotel rooms, kitchens,
and all other applications where
localized sound alarm is required.
The new VELOX sounder base
is a leading technology in alarm
systems, fully microprocessor
loaded, allowing four differ tones
and four different volume to be
selected. Furthermore, as low as
0.8mA of current consumption, make
it easy to connect 178 sounder base
along with 178 detectors.
The new VELOX sounder base, can as well extend the function of the remote alarm to the detector; hence a remote
indicator can be connected as well, which shall be activated along with the sounder.
The VELOX sounder technology does not require any address to be assigned to it. Once connected to the loop, the
sounder processor communicates with the VELOX fire panel and assigns a sub-address from the installed sensor.
TECHNICAL SPECIFICATIONS
40200
STANDARD
POWER SUPPLY
EN54-3
From 15 Vdc (Min) to 52 Vdc (Max)
ALARM CURRENT CONSUMPTION
0.8mA to 2.8mA (based on dBA output volume selection and tone selection)
OPERATING TEMPERATURE RANGE
-20 to 60 ˚C
HUMIDITY
NUMBER OF DEVICES ON THE LOOP
SOUND OUTPUT (MAX)
DIMENSION
95% RH (non-condencing)
178 sounder base
94 dBA
111 Dia (:mm), Height 31.5 (:mm)
WEIGHT
145 g
COLOR
RAL 9016 as standards , Decorative colors on demand optional
19
ADDRESSABLE
SOUNDER & BEACON
A selection of various tones and adjustable
sound output volume allows installation
and application of the VELOX range of
sounders in different environments.
Different tone patterns can be set to
identify alert and evacuation signals.
Tones for applications such as BS fire
tone, DIN tone and Dutch fire tone
can be selected from the fire alarm
control panel and programmed
for different situations and with
different time variations.
A rotary volume control at the
rear of the devices allows setting
up of the tone volumes according
to different requirements and
applications.
40300
Sounder
40320
Features
• Compliant
with
A1:2002, A2:2006
EN54-17:2005
EN54-3:2000
• Inbuilt short-circuit isolator
• Automatic & Manual addressing
features
• Up to 100 dB output at 1 m
• Fully synchronized tones
• Programmable tones from the fire
alarm control panel
• Selectable flash rate and light output intensity
The devices are powered from the
same fire detection loop which connects
the fire alarm control panel, detectors,
beacons, manual call points, etc. Therefore,
additional power supply sources are not required.
40321
40301
40340
Sounder Beacon
Waterproof Sounder Beacon
Waterproof Sounder
ADDRESSABLE BEACON
Loop powered high output (up to 100dBA)
intelligent wall mounted sounder with
integrated LED beacon.
Waterproof audiovisual sounders with
integrated LED beacon can be installed
in humid and wet environments.
Waterproof audiovisual sounders can be
installed in humid and wet environments.
Low current loop powered LED array
beacon.
TECHNICAL SPECIFICATIONS
40300 - 4030 1
40320 - 40321
POWER SUPPLY
MINIMUM OPERATING VOLTAGE
15 VDC
STANDBY CURRENT CONSUMPTION
ALARM CURRENT CONSUMPTION
70 uA (typical)
5 - 7 mA (at 24 V)
8 - 10 mA (at 24 V)
OPERATING TEMPERATURE RANGE
MAXIMUM WIRE GAUGE
1 DB(A) VARIATION DEPENDING ON TONE PATTERN
20
3 -6 mA (at 24 V)
-10 °C to +55 °C
HUMIDITY
SOUND OUTPUT VOLUME (SELECTABLE)
40340
19-30 VDC
80 - 100 dB(A)
5 - 85% RH
5 - 95% RH
2.5 mm2
0.5 - 2.5 mm2
89 - 100 dB(A)
-
BEACON FLASH RATE
-
1 Hz
0.5 / 1 Hz
BEACON FLASH LIGHT INTENSITY
-
> 1 Cd
0.5 / 1 Cd
Fire Alarm Systems
INTELLIGENT
REMOTE INDICATOR
Features
A D D R E S S A B L E R E M OT E I N D I C AT O R L A M P
• Powered from the fire alarm loop
• In-built isolator for protection
against short circuits
• Automatic & Manual addressing
features
• IP42 protection rating
The 40330 addressable remote
indicator lamp is an output device
that activates its LED to provide
a visual indication of fire alarm
conditions.
The addressable remote indicator
is controlled, activated and
deactivated from the fire alarm
control panel.
The device which can be mounted
on a wall or ceiling is ideal
for installation in sites where
detectors are inaccessible.
Features
• Directly powered from the detector head
• Fast localization of an alarm
condition
• Programmable from the fire alarm
control panel to respond to multiple detectors within a fire zone
R E M O T E I N D I C AT O R
LAMP FOR DETECTORS
The 3330 remote indicator lamp
provides local indication of fire
detector in alarm. The device
functions as an LED optical
repeater when wired to a detector.
The remote indicator is controlled
and powered directly by the detector, which supplies a current of 20 mA
to drive the indicator.
The repeater can be installed away from the detector to indicate an alarm
conditions by illumination of the LED.
The device can be mounted on a wall or ceiling.
TECHNICAL SPECIFICATIONS
40330
APPLIED VOLTAGE
18 — 40 Vdc
3330
AVERAGE CURRENT CONSUMPTION
AVERAGE STANDBY CURRENT CONSUMPTION
50 μA @ 24 Vdc
HUMIDITY (NON CONDENSING)
ACTIVATED LAMP CURRENT ABSORPTION
4.5 mA @ 24 Vdc
OPERATING TEMPERATURE RANGE
LOOP CABLE’S WIRE GAUGE RANGE
4.5 mA
95%
-30°C to +70°C
0.5 — 2.5 mm2
BODY COLOUR
White
OPERATING TEMPERATURE RANGE. NO CONDENSATION
-30 to +70 °C
LENS COLOUR
Red
MAXIMUM TOLERATED HUMIDITY. NO CONDENSATION
95% RH
DIMENSIONS
80 x 80 x 27 mm
21
1154h
ADDRESSABLE
MANUAL CALL POINT
The
intelligent
analogue
addressable manual call point
is an emergency alerting device
which can be activated by
pressing a transparent plastic
window on its front side.
The emergency call point once
activated can be reset by using a
key supplied with the device.
A bicolour (red/green) LED
provides the status of the device.
Features
• Compliant with EN54-11:2001 +
A1:2005 EN54-17:2005
• Transparent plastic window on
front panel for activation
• No glass breaking activation
• Key reset mechanism
• Automatic & Manual addressing
features
• Inbuilt short circuit isolators
Waterproof call points can be
installed in humid and wet
environments.
Up to 240 devices can be
connected on a single loop,
which can extend to 2 km as
per load calculations and cable
selections.
The devices are powered from
the same fire detection loop
which connects the fire alarm
control panel, detectors, beacons, sounders, etc. Therefore, additional power supply sources are not required.
40801
Waterproof Call point
The intelligent call point has a
resettable plastic element which has
the look of glass.
40802
Resettable Call point
40802 provides a clear plastic cover for
the 40800 callpoint that can be secured
to prevent miss-use and false alarms.
intelligent call point available in blue,
green, white, yellow colour
Call Point double action cover
TECHNICAL SPECIFICATIONS
40800
POWER SUPPLY VOLTAGE RANGE
from 18 Vdc to 40 Vdc
AVERAGE CURRENT CONSUMPTION
70 uA
LED CURRENT CONSUMPTION
6 mA ( @ 24 Vdc )
OPERATING TEMPERATURE RANGE
-20 °C to +65 °C
HUMIDITY
DIMENSIONS (W/O BACK BOX)
95% RH - no condensation
87 x 87 x 23 mm
MAXIMUM WIRE GAUGE
INTERNATIONAL PROTECTION RATING
22
40801
Fire Alarm Systems
119 x 128 x 62 mm
2.5 mm2
IP31
IP67
1154j
SINGLE & MULTIPLE CHANNEL
INPUT/OUTPUT MODULES
Features
VELOX input/output modules enable setting up of a
‘cause and effect’ plan for the various detection and
alerting devices and activate emergency measures
involved in life safety.
• Compliant with EN54-17:2005
and EN54-18:2005
• Devices are controlled and
monitored in supervised and unsupervised modes
• Automatic & Manual addressing
features
• Easy to mount
• Industrial applications
• Weather resistant
• Up to 240 devices per loop
• Powered from the loop
• Twin Bi-Color LED for Status and
Fire Single
• Inbuilt short circuit isolators
The modules act as an interface between the fire
detection loop and external devices on heating,
ventilation and air conditioning networks.
The addressable modules can be used to monitor
sensory devices via its input terminals and then
activate fire control mechanisms such as control of
fire shutters, sprinklers, ventilation and air conditioning
equipment via its output terminals.
The input modules can supervise devices for alarm,
short, open, and earth conditions.
The modules are available in various sizes and
designs to suit different conditions in commercial and
industrial sites and for greater flexibility in installing in
standard electrical boxes.
The devices are powered from the same fire detection
loop which connects the fire alarm control panel,
detectors, beacons, manual call points, etc. Therefore,
additional power supply sources are not required.
SINGLE CHANNEL MICRO
INPUT/OUTPUT MODULES
SINGLE CHANNEL DIN RAIL
MOUNT INPUT/OUTPUT
Analog Addressable Input &
Output Modules
SINGLE CHANNEL MINI
INPUT/OUTPUT MODULES
Micro input/output modules are
lightweight devices that provide flexibility
in installation.
DIN rail input/output modules are suitable
for industrial applications. They can be
mounted on 19-inch racks or in standard
electrical boxes.
The VELOX 40000 is the latest technology
from ATEIS, simple to install and easy to
program,
Mini input/output modules are suitable for
installation in commercial and industrial
environments.
TECHNICAL SPECIFICATIONS
40100-M
SUPERVISED INPUT
SUPERVISED OUTPUT
RELAY (FORM C) OUTPUT
NUMBER OF ADDRESSES ON LOOP
LOOP’S VOLTAGE RANGE
AVERAGE CURRENT CONSUMPTION
LED’S CURRENT CONSUMPTION
ANALOG ADDRESSABLE INPUT &
OUTPUT MODULES
MINI INPUT/OUTPUT
1
1
40010-M 40002-M 40110-M 40102-M
1
1
2*
1
1
1
2
1
2*
2
MICRO INPUT/
OUTPUT
DIN RAIL MOUNT INPUT/OUTPUT
40100
40010
40002
40110
40102
1
1
1
1
2*
1
1
1
2
1
2*
2
40100-D 40010-D 40002-D 40110-D 40102-D 40100-U 40001-U
1
1
1
1
2*
1
15-40 VDC
15-40 VDC
15-40 VDC
120 uA (@ 24 V)
120 uA (@ 24 V)
120 uA (@ 24 V)
6 mA (@ 24 V)
6 mA (@ 24 V)
6 mA (@ 24 V)
1
1
2
1
2*
2
1
1
1
1
15 V (min) - 40
V (max)
120 uA (@
24 V)
-
* Two single pole double thro w relays; both relays ha ve the same address and cannot be triggered individually.
23
MULTIPLE CHANNEL
INPUT/OUTPUT MODULES
multi-input, multi-output modules are addressable
control and monitoring devices used to supervise
and activate auxiliary devices such as sounders,
strobes, shutters, and water flow switches.
Modules with multiple inputs and
outputs are suitable replacements
for several single-input/output
modules installed for applications
such as control of elevators,
sprinkler systems, doors, and fire
fighting systems.
Each channel (input or output) on the
VMIC module can be controlled by the VELOX
4000 series of fire alarm control panels.
The input channels can be supervised for Normal,
Alarm, and Fault conditions by using end-of-line resistors.
The supervised output channels can be used to either monitor
an external load via an end-of-line resistor or supervise an external
power supply for the output. The relay (Form C) outputs are nonsupervised outputs for the control of auxiliary devices, and they can be
controlled by the fire alarm control panel.
Features
• Compliant with BS EN54-17 and
BS EN54-18
• Supervised input/output channels
• In-built isolator for protection
against short circuits.
• Automatic & Manual addressing
features
• Tri-color LED indicators
• Weatherproof enclosure with IP65
protection rating
• Up to 240 devices per loop
The devices are powered from the same fire detection loop which connects the fire alarm control panel, detectors,
sounders, beacons, manual call points, etc. Therefore, additional power supply sources are not required.
Features
ISOLATOR MODULE
• Protection against open and short
circuit faults
• Short-circuit isolation for up to 32
devices
ISOLATOR MODULE
isolator module provides short-circuit
isolation for analog intelligent fire detection
and alarm loops. The isolator module is
required when LV100, LV200 and LV350
smoke and heat detectors are used on the
loop, because the detectors come without
in-built short-circuit isolators.
TECHNICAL SPECIFICATIONS
ISOLATOR MODULE
40404
40422
SUPERVISED INPUT
SUPERVISED OUTPUT
RELAY (FORM C) OUTPUT
4
4
4
2
2
6
2
NUMBER OF ADDRESSES ON LOOP
LOOP’S VOLTAGE RANGE *
STANDBY CURRENT CONSUMPTION
OPERATING TEMPERATURE RANGE
HUMIDITY
DIMENSIONS
MAXIMUM NUMBER OF VEGA LITE DEVICES THAT CAN BE “CUT
OFF” BY THE ISOLATOR MODULE
MAX WIRE GAUGE RANGE
8
8
from 18 V to 40 V
500 μA at 24 V
-100 °C to + 55 °C
from 5 RH% to 85 RH%
210 x 170 x 65 mm
8
*Product opera tes do wn to 15 V, but without LED indica tion.
24
MULTIPLE CHANNEL INPUT/OUTPUT MODULES
Fire Alarm Systems
40602
40510
15-40 V
90 μA at 24 V
from -30 °C to + 70 °C
from 5 RH% to 85 RH%
75 x 52 x 28 mm (w/o brackets)
-
32 units
2.5 mm
2
CUSTOMIZABLE
SHOP INTERFACE
Features
• Interfacing of fire alarm loop with
conventional fire detection and
alarm networks
• EN54 compliant power supply
and charger
• Two LEDs on front panel indicate
power supply and fault conditions
• Multiple combinations of input/
output modules
• Flexible mounting and wiring
options
• IP30 protection
• Expandable up to 12 channel of
I/0
• DIN Rail for External Relay
connection
• Battery Backup for 24 h and 30
mim of alarm operation
The IFU100 is a customizable
enclosure
designed
to
accommodate
input/output
interface modules, relays, power
supply units and chargers
to function as an interfacing
device to link independent fire
alarm networks and security
mechanisms with the centralized
fire alarm and detection and
PAVA systems in a building.
The interface devices and power
supply are housed in the steel
enclosure which provides IP30
protection. The enclosure has a
key lock mechanism to restrict
unauthorized access.
The IFU100 is an easy-to-install unit that can interface addressable fire alarm networks with conventional fire
alarm networks and building management systems such as HVAC, lifts, security and power systems.
TECHNICAL SPECIFICATIONS
IFU100
POWER SUPPLY
220 - 230V AC (INPUT)
24V DC (OUTPUT)
DIMENSIONS
535 X 345 X 125 MM
INPUT SUPPLY
1.5A PSE:220-240V AC, 50/60HZ, FUSE T3.15H250 3.0A/5.0A PSE:120-230V AC, 50/60HZ,FUSE T3.15H250
OUTPUT VOLTAGE
MAX 28.5V DC, MIN 18.5V DC AT MINIMUM BATTERY VOLTAGE OF 19V WITH MAINS DISCONNECTED
CHARGER VOLTAGE
27.4V DC NOMINAL AT 20°C TEMPERATURE COMPENSATED OVER THE RANGE -5°C TO +45°C
OUTPUT CURRENT
1.5A PSU: 1.0A CONTINUOUS LOAD, 0.5A BATTERY CHARGE 3.0A PSU: 2.0A CONTINUOUS LOAD, 1.0A BATTERY CHARGE [3.0A TO LOAD IF
CONFIGURED FOR PSU ONLY] 5.0A PSU: 3.0A CONTINUOUS LOAD, 2.0A BATTERY CHARGE [5.0A TO LOAD IF CONFIGURED FOR PSU ONLY]
ENVIROMENT
ON BOARD INDICATION
INDOOR, DRY
MAINS FAIL, CHARGER FAIL, BATTERY OPEN CIRCUIT, BATTERY LOW & HEARTBEAT
25
FIRE
TELEPHONE SYSTEM
Features
The VELOX 4000 seris of integrated fire alarm, mass
notification and fire telephone systems come with a
master handset used to control all call operations on
an emergency voice communication system (EVCS).
• Up to 8 master handsets per system
• Up to 256 lines
• Unique 16-character name for
addressing each line
• Wall, desk, and rack mount
The master handset is connected to outstation
handsets on the fire telephone network via an eightline exchange, which is part of the EVCS network.
The VCC5 is a compact 5-line fire telephone system
suitable for small buildings which require a basic
emergency voice communication system (EVCS).
The VoCall VCX8 is an eight-line exchange used to
network and power the master handset and eight lines
on an emergency voice communication system (EVCS).
The VCX8 eight-line exchange is part of the EVCS
network comprising a master handset and outstation
handsets.
VoCall outstation handsets are connected to the line
exchange
of an emergency voice communication system (EVCS).
The handsets are part of the EVCS network comprising
a master handset and eight-line exchange.
The outstations have two type of fixed handsets. Type
A handset is used for evacuation or fire fighting. The
Type B handset is used where installation of a Type A
is impractical.
The VCRHS roaming handset can be connected to an
emergency voice communication system (EVCS) via a
telephone jack connected to EVCS network or the fire
detection loop in case of an integrated fire alarm fire
telephone system.
The roaming handset offer exceptional flexibility in
establishing communication via the EVCS network
comprising a master handset, eight-line exchange, and
outstation handsets.
An EVCS is a fixed, secure, bi-directional, full-duplex
voice communication system to assist fire fighters in an
emergency in high-rise buildings or large sites where
radio communication may not work.
TECHNICAL SPECIFICATIONS
VCM
DIMENSIONS
POWER SUPPLY
CURRENT
STANDARDS
26
VC X- 8
268 x 275 x 85mm
300mm x 350mm x 120mm
296 x 210 x 80mm
230V AC + 20%
230VAC +/- 10% 50/60Hz
230V AC + 20%
12V SLA 3.2AH
Deep discharge, Short,
Thermal
11 mA
1.49 Kg
6.5 Kg
1.6 kg
Stainless Steel Brushed
-
Zintec, Texture Powder
coated RAL7032
EN55103-1, EN55103-2 , BS5839-pt9,
BS5588-pt8
-
EN55103-1, EN55103-2,
EN61000-3-2, BS61000-3-3,
EN60950, ES5839-Part 9,
BS5588-Part 8
WEIGHT
MATERIAL
VCC5
Fire Alarm Systems
EVC S
EVC S
TYP E A
TYP E B
320 x 295 x
150mm
133 x 133 x
45mm
JA C K P L ATE
RO AMI NG
HANDSET
86 x 86 x 25mm
210 x 66 x
45mm
-
-
-
-
-
-
0.14 Kg
-
Zintec, Texture Powder coated
RAL3001 Single Red
Brushed Stainless
Steel
-
EN55103-1, EN55103-2,
EN60950, BS5839pt6,BS5588-pt8, EN60118-4
EN55103-1, EN55103-2, BS5839pt9, BS5588-pt8, BS60118-4
1.4 Kg
1.105 Kg
FIRE
TELEPHONE SYSTEM
VCX-8
T Y PE A
LINE EXCHANGE
OUTSTATIONS FIXED HANDSETS
• Up to 32 exchanges on the EVCS
• Up to 32 exchanges on the EVCS
• Up to 256 lines
• Full monitoring of each line for faults
• Battery backup up to 24 h and 30 min
•
•
•
•
network
network
alarm operation
V CC5
T Y PE B
COMPACT 5-LINE FIRE TELEPHONE
OUTSTATIONS FIXED HANDSETS
•
•
•
•
•
Compliant with BS5839-9
•
•
•
•
•
•
15 status LEDs
Full duplex system
V CR HS - V C R J PP
V CM
ROAMING HANDSET & TELEPHONE JACK
Master Handset
• Flexible roaming phone and cable
• Low-noise telephone jack
• Addressable telephone jack on fire panel
loop
Fully Monitored
Stainless Steel Option
network
Onsite programming not required
and BS5839-9, BS5588-8, BS601184
Full monitoring of each line for faults
• Up to 32 exchanges on the EVCS
Up to 5 outstations per system
• Compliant with EN55103-1, EN55103-2
Up to 256 lines
Up to 256 lines
Full monitoring of each line for faults
Hands Free Operation
Flashing Status LED
Duplex Speech
Stainless Steel Option
• Monitored Handset
• Large High Contrast Display(4x20 Character)
•
•
•
•
•
12 Key Quick Dial Keypad
Full Duplex System
Up-to Eight Masters Per System
Directory Dial Function
Controls Up-to 256 Lines (32 VCX-8
Exchanges)
• 16 Character Unique Name Per Line
• Dual Network Ports
• Remote Powered
27
PARTS LIST
FIRE ALARM C ON T ROL PA N E L S
4706/Y
High Intensity yellow LED & 600mm Lead for Boxed Mimic and Evac
Control Units
PRODUCT CODE
4706/G
High Intensity green LED & 600mm Lead for Boxed Mimic and Evac
Control Units
DESCR IPT ION
VELOX 4200 - 4400 - 4800
4200
1-2 loop (without glass door)
4200GLZ
1-2 loop (with glass door)
4200INT
1-2 loop (integrated with telephone and microphone)
4200INT/TEL
1-2 loop (integrated only with telephone)
4200INT/PSSDT
1-2 loop (integrated only with microphone)
4400
1-4 loop (without glass door)
4400GLZ
1-4 loop (with glass door)
4400INT
1-4 loop (integrated with telephone and microphone)
4400INT/TEL
1-4 loop (integrated only with telephone)
4400INT/MP
1-4 loop (customized with Mimic Panel)
4400INT/SM
1-4 loop (customized with smoke management control)
4800
2-8 loop (without glass door)
4800GLZ
2-8 loop (with glass door)
4800INT
2-8 loop (integrated with telephone and microphone)
4800INT/TEL
2-8 loop (integrated only with telephone)
4800INT/MP
2-8 loop (customized with Mimic Panel)
4800INT/SM
2-8 loop (customized with smoke management control)
4001
Loop driver card
VELOX 4030 - 4035 (ON-BOARD AND PORTABLE PRINTERS)
4030
On-board printer for 4200 /4400 - Fitted
4031
On-board printer for 4200 /4400 (Retro-fit)
4032
External boxed panel printer for 4200 /4400
Single Loop Analogue Addressable Fire Alarm Control Panel
2200
Two loop analogue addressable fire alarm control panel
ACCESSORIES
2232
RS232 communication card
2485
RS485 communication card
2019
TCP/IP communication card
2000-GUI
Graphical user interface utility
2000-RPS
Remote programming software
2000-PSU
Intelligent power supply unit
POWER SUPPLY UNITS
4090
1.5A PSU & charger (boxed - 7Ah battery capacity)
4091
3A PSU & charger (boxed - 7Ah battery capacity)
4092
3A PSU & charger (boxed - 17Ah battery capacity)
4093
5A PSU & charger (boxed - 17Ah battery capacity)
4094
5A PSU & charger (boxed - 24Ah battery capacity)
CARDS & ACCES S ORIES ( NET W ORK CARDS )
PRODUCT CODE
D ES C R I P TI O N
NETWORK CARDS
4420
Standard network card
4421
Fault-tolerant network card
4033
Spare shrink wrap battery pack for 4031 printer
BMS/GRAPHICS INTERFACE CARD
4034
Spare paper roll for 4031 printer (pack of 10)
4120
BMS/graphics interface card (standard network interface)
4035
Portable Thermal Printer c/w re-chargeable battery & leads
4121
BMS/graphics interface card (fault-tolerant network interface)
VELOX 4010 - 4020 (REMOTE DISPLAY AND CONTROL TERMINALS)
IP INTERFACE CARD
4010
Remote Display Terminal with standard network interface, 24V DC
4124
IP gateway with standard network interface (boxed)
4020
Remote Control Terminal with standard network interface, 24V DC
4125
IP gateway with fault-tolerant network interface (boxed)
4010/FT
Remote Display Terminal with fault-tolerant network interface, 24V DC
BACNET/IP/MODBUS INTEGRATOR
4020/FT
Remote Control Terminal with fault-tolerant network interface, 24V DC
4130
MIMIC PANELS (BOXED MIMIC AND EVACUATION CONTROL UNITS)
28
VELOX 2100 - 2200 (ANALOG ADDRESSABLE FIRE ALARM CONTROL PANELS)
2100
BACNET/IP/MODBUS Integrator
CARDS & ACCES S ORIES ( P ERIP HERAL CARD)
4727
100 zone panel mounted mimic for 4200 /4400. Artwork required.
4720
100 way remote LED mimic enclosure (type 1). Artwork required
PRODUCT CODE
4721
100 way remote LED mimic enclosure (type 2). Artwork required
OUTPUT CARDS
4722
Fault Tolerant 100 way remote LED mimic enclosure (type 1)
4042
2-way programmable relay output card
4723
Fault Tolerant100 way remote LED mimic enclosure (type 2)
4048
8-way programmable relay output card
4745
50 way network I/O controller boxed (type 2) c/w psu
INPUT CARD
4746
50 way fault-tolerant network I/O controller boxed (type 2) c/w psu
4148
D ES C R I P TI O N
8-way programmable relay input card
MIMIC PANELS (LED INDICATORS AND SWITCH INPUTS FOR BOXED MIMIC UNITS)
PERIPHERAL BUS ADAPTOR CARD
4726/F
High Intensity red LED for Boxed Mimic and Evac Control Units - Fitted
4060
4726/Y
High Intensity yellow LED for Boxed Mimic and Evac Control Units - Fitted
GENERAL ROUTING INTERFACE CARD
4726F/G
High Intensity green LED for Boxed Mimic and Evac Control Units - Fitted
4061
4731/2T
2-Position key switch trapped for 4745 and 4746 - Fitted
PROGRAMMABLE RELAY CARD
4731/2U
2-Position key switch un-trapped for4745 and 4746 - Fitted
4064
4-way relay card
4731/3U
3-Position key switch un-trapped for 4745 and 4746 - Fitted
4065
4-way relay card with 1.5A PSU (boxed)
4733
Non-illuminated push button for 4745 and 4746 - Fitted
PROGRAMMABLE SOUNDER CARD
4733/R
Illuminated (red) push button for 4745 and 4746 - Fitted
4062
4-way sounder card
4733/G
Illuminated (green) push button for 4745 and 4746 - Fitted
4063
4-way sounder card with 4A PSU (boxed)
4752
Mimic driven 10-way relay output card
ZONAL LED INDICATOR
4752/D
Mimic driven 10-way relay output card in din-rail carrier
Peripheral bus interface adaptor
Fire alarm routing interface card (monitored I/O)
4081
20 zone LED card for 4100 (fitted)
MIMIC PANELS (KEY SWITCHES AND PUSH BUTTONS FOR 50-WAY NETWORK I/O CONTROLLER )
4082
20 zone LED card for 4200/4400 (fitted)
4700
100 way remote LED mimic driver (un-boxed)
4083
50 zone LED card for 4200/4400 (fitted)
4700/FT
Fault Tolerant 100 way remote LED mimic driver (un-boxed)
4084
50 zone LED card for 4200/4400 (retrofit)
4705
50 way network I/O controller (un-boxed)
4085
100 zone LED card for 4200/4400 (fitted)
4705/FT
50 way fault-tolerant network I/O controller (un-boxed)
4086
100 zone LED card for 4200/4400 (retrofit)
4706
High Intensity red LED & 600mm Lead for Boxed Mimic and Evac
Control Units
4087
200 zone LED card for 4200/4400 (fitted)
4088
200 zone LED card for 4200/4400 (retrofit)
Fire Alarm Systems
PARTS LIST
SOUNDER SPLITTER CARD
4070
4-way sounder splitter card
4071
4-way sounder splitter card with 4A PSU boxed)
SOUNDER BOOSTER CARD
4072
4-way sounder booster card
4073
4-way sounder booster card with 4A PSU boxed)
CA RD S & AC C E SSORIE S ( P R O G R A M M I N G D EV I C E)
ADDRES S ABL E L OOP P OW ERED S OU NDER BAS E
PRODUCT CODE
D ES C R I P TI O N
40200
4 Tone Intelligent Addressable Loop Powered Sounder Base
40220
32 Tone Intelligent Addressable Loop Powered Sounder/Flasher Base
40201
Silicon Base Cover for Waterproof protection
ADDRES S ABL E S OU NDER & BEACON
PRODUCT CODE
D ES C R I P TI O N
40300
Intelligent Addressable loop Powered Wall Mounted Sounder
40300-H
Intelligent Addressable loop Powered Wall Mounted Sounder with Slow
Whoop Red
40300-HW
Intelligent Addressable loop Powered Wall Mounted Sounder with Slow
Whoop White
C ON FIGU RAT ION S OF T WA R E
40301
Intelligent Addressable loop powered, waterproof, Wall Mounted
Sounder
PRODUCT CODE
DESCR IPT ION
LOOP DRIVER AND ANALYZER
40710
Addressable Loop Line Driver
HANDHELD PROGRAMMING UNIT
40700
Addressable Device Programmer
PRODUCT CODE
DESCR IPT ION
40320
Intelligent Addressable Loop Powered Sounder Flasher, Wall Mounted.
4500
Configuration software & lead
40321
4501
Configuration software & USB upload/download lead
Intelligent Addressable Loop Powered, Waterproof, Sounder / Flasher,
Wall Mounted
4502
Remote dial-up software (virtual panel)
40340
intelligent Addressable Loop Powered Beacon
4503
Graphical control software (single panel, compact version)
INT EL L IGENT REMOT E INDICAT OR
4504
Graphical control software (up to 10 node connection)
4505
Graphical control software (up to 99 node connection)
PRODUCT CODE
D ES C R I P TI O N
4506
Logo programming software
40330
Intelligent Addressable Loop Powered Remote Indicator
3330
Remote Indicator Connected to Detector Base
INTELLI GE N T D E T E C T O R S W I T H & W I T H O UT I S O L AT O RS
PRODUCT CODE
DESCR IPT ION
INTELLIGENT DETECTORS WITH ISOLATORS
V100
Smoke detector with inbuilt short circuit isolator
V200
Smoke & heat detector with inbuilt short circuit isolator
V350
Heat detector with inbuilt short circuit isolator
INTELLIGENT DETECTORS WITHOUT ISOLATORS
LV100
Smoke detector without inbuilt short circuit isolator
LV200
Smoke & heat detector without inbuilt short circuit isolator
LV350
Heat detector without inbuilt short circuit isolator
DETECTORS & ACCESSORIES
40900
Standard adaptor base for mounting detectors
40900-R
Standard base with inbuilt relay
40900-S
Standard adaptor base with shorting clip
40900-DP
Deep adaptor base
TMD-01
Detector test magnet
DC100
Dust cover
CA100
Conduit adaptor
INTELLI GE N T AD D RE S S A B L E S M O K E B EA M D E T E C T O R
ADDRES S ABL E MANU AL CAL L P OINT
PRODUCT CODE
D ES C R I P TI O N
40800
Intelligent Addressable Manual Call Point
40800-B
Intelligent Addressable Manual Call Point in Blue Color
40800-G
Intelligent Addressable Manual Call Point in Green Color
40800-W
Intelligent Addressable Manual Call Point in While Color
40800-Y
Intelligent Addressable Manual Call Point in Yellow Color
40801
Intelligent Addressable Manual Call Point Waterproof
40800-F
Intelligent Addressable Manual Call Point installation frame
40802
Intelligent Addressable Manual Call Point double action cover
S INGL E & MU LT IP L E CHANNEL INP U T /OU T P U T MODULE S
PRODUCT CODE
D ES C R I P TI O N
SINGLE CHANNEL MINI INPUT/OUTPUT MODULES
40100-M
Single input mini module
40010-M
Single output mini module
40002-M
Dual output (Form C) mini module
40110-M
Single input/output mini module
40102-M
Single input/dual output (Form C) mini module
PRODUCT CODE
DESCR IPT ION
ANALOG ADDRESSABLE INPUT & OUTPUT MODULES
40960
Intelligent Reflective Beam Smoke Detector
40100
Single input module (4" x 4” wall mount)
40960-80
Range Extension Kit up to 80 meter
40010
Single output module (4” x 4” wall mount)
40960-100
Range Extension Kit up to 100 meter
40002
Dual output (Form C) module (4” x 4” wall mount)
40960-MP
Mounting Plate for Beam Head or Single Reflector
40110
Single input/output module (4” x 4” wall mount)
40960-AB
Adjustable Wall Bracket
40102
Single input/dual output (Form C) module (4” x 4” wall mount)
INTELLI GE N T AD D RE S S A B L E D UC T D ET E C T O R
PRODUCT CODE
DESCR IPT ION
40950
Intelligent Addressable Duct Detector with Standard Base
40951
Intelligent Addressable Duct Detector with Relay Rase
40950-06
0.6 meter Sampling Pipe
40950-15
1.5 meter Sampling Pipe
SINGLE CHANNEL DIN RAIL MOUNT INPUT/OUTPUT MODULES
40100-D
Single input module (DIN rail mount)
40010-D
Single output module (DIN rail mount)
40002-D
Dual output (Form C) module (DIN rail mount)
40110-D
Single input/output module (DIN rail mount)
40102-D
Single input/dual output (Form C) module (DIN rail mount)
SINGLE CHANNEL MICRO INPUT/OUTPUT MODULES
40950-28
2.8 meter Sampling Pipe
40950-BR
Installation Duct Detector Bracket
40100-U
Single supervised input module (micro module with flying leads)
40950-SG
Duct Detector Spare Gasket
40010-U
Single supervised output module (micro module with flying leads)
40950-DF
Duct Detector Filter
40004-U
Single form C output module (micro module with flying leads)
29
PARTS LIST
ACCESSORIES
MB100
Standard mounting box for modules
DMB100
Deep mounting box for modules
M ULTIP LE C HAN N E L INP UT / O UT P UT M O D UL E S
PRODUCT CODE
DESCR IPT ION
40404
4 input channels, 4 relay (Form C) output channels
40422
4 input channels, 2 supervised output channels, 2 relay (Form C)
output channels
40602
6 input channels, 2 relay (Form C) output channels
40500
Conventional zone module
40510
Isolator Module
ACCESSORIES
MB100
Standard mounting box for modules
DMB100
Deep mounting box for modules
C USTO M IZ ABL E SHOP I N T ER FA C E
PRODUCT CODE
DESCR IPT ION
IFU100
Customizable Shop Interface unit
FIRE TE L E PHON E S YST E M
PRODUCT CODE
DESCR IPT ION
VELOX 4000 SERIS / TEL
4200INT
1-2 loop fire alarm control panel integrated with fire telephone and
microphone
4200/TEL
1-2 loop fire alarm control panel integrated only with fire telephone
4400INT
1-4 loop fire alarm control panel integrated with fire telephone and
microphone
4400INT/TEL
1-4 loop fire alarm control panel integrated only with fire telephone
4800INT
2-8 loop fire alarm control panel integrated with fire telephone and
microphone
4800INT/TEL
2-8 loop fire alarm control panel integrated only with fire telephone
VCM (MASTER HANDSET)
VCM
Vocall Master Handset (rackmounted with GREEN LCD display)
VCWM
Wall mount master handset in VoCALL Compact Case with Revision
3 software (No audio out, No active relay output) for connection to
current exchanges
VCX-8 (LINE EXCHANGE)
VCX-8
Eight line exchange
VCC5 (COMPACT 5-LINE FIRE TELEPHONE)
VCC5
VoCALL Compact 5 Line Fire Telephone & Disabled Refuge System
VCRHS - VCRJPP (ROAMING HANDSET & TELEPHONE JACK)
VCRHS
Vocall Roaming handset
VCRJPP
Jack point PCB for installation into other plated as needed
VCRJP
Vocall single gang stainless Jack
TYPE A & TYPE B (OUTSTATIONS FIXED HANDSETS)
30
VCFHP
Vocall Red flush push door handset
VCFHP-SS
Vocall Stainless Steel flush door handset
VCSHP
Vocall Red surface push door handset
VCSHP-SS
Vocall Stainless Steel surface door handset
VCSHF
Type B Vocall surface with Red Overlay
VCSHF-SS
Type B Vocall Stainless Steel surface
VCFHB
Type B Stainless Steel Bezel to flush mount VCSHF
Fire Alarm Systems
REFERENCES
Many projects have already been installed by ATEÏS in the Middle East and India, and the company is proud to have been associated with these
major installations in the region — and particularly the Hospitality and Transportation sectors, where ATEÏS’ high end products have regularly been
implemented to fulfill their demanding requirements.
Middle East:
Abu Dhabi • yas waterworld • Ferrari World • Sky Tower-Al Reem
Island • Alwahda Mall • Al Quaa KG • Egyptian Orthodox Coptic Church
• Capital Plaza Mixed Use Development • Holiday Inn-Danet • Delma
Mall • Vision Suits • Masdar Institute of Science & Technology • Sheikha
Salama Grand Mosque • Building Materials City Mall • Al Wahda Grand
Millennium Hotel • Yacht Club, Yas Island • Yas Marina Hotel • Rotana
Hotel Yas Island • Centro Yas Hotel • Danet Mall • Marina Square Block
A and D- Al Reem Island • Mubadala Development Head Quarters •
Abu Dhabi Ladies Club • City of Light-Tamouh • Bustan Palace Hotel •
Novotel & IBIS Hotel- Abu Dhabi Gate • Future Schools • Burjeel Hospital • Bab Al Qasr • Al Ain Convention Center • Rihan Heights Arzaneh
Towers • Al Nasir HQ-ADNEC • Beach Towers-Al Reem Island • Hayat
Park –Al Saadiyat • Arjan Hotel • Presidential Flight Complex • Brooge
Pipe Academy • Brighton College • Dusit Hotel • Millennium Al Ain •
Emirates National School • Franco Emerian Hospital, Marasi Complex •
Arzanah Hospital • Centro Rotana Hotel-Airport Road • Al Badi Rotana
Hotel-ADNEC • Centro Rotana Hotel-ADNEC • Royal City Season Hotel
• Al Hamara Plaza Hotel • Al Waha Mall-Al Ain • Police Stations-Al Ain •
Theatre and Swimming Pool-Swiehan Base • Dubai • Metro Dubai Red
& Green Line • Emirates Towers • Dubai Festival Center • Mirdif Mall
• JAL Tower Hotel • Dubai Civil Defense HQ • Ibn Battuta Twin Tower •
Business Village • Jumeirah Zabeel Saray • Golden Miles Apartments
Palm Jumeirah • Shore line Apartments Palm Jumeirah • Ski Dubai
• Gate Village • 11 Towers • Dusit Hotel • Jumeirah Beach Hotel •
Marsa Plaza • Villa 18 in Umm al Sheif • Villa KTP2 at Palm Jumairah
• Damac Burjside Boulevard • City Premiere Hotel at Dubai Marina •
Le meridian Hotel at Mina Siyahi • Fujairah Commercial Complex • G+5
Commercial building Al Khan , SHJ • Azadi Factory, Iraq • Damac Burj
Terrace • Capital Bay Towers (Damac) • School for Ministry of Public
Works at RAK, Sharjah, Fujairah • Burj Development plot 55, 56, 57,
58 & 59 • Carrefour at FCC • Vox Cinemas at FCC • RAK Precast,
RAK • Majan printing press,RAK • Union cement factory,RAK • Union
fiber glass factory, RAK • Double Tree by Hilton, RAK • RAK Hotel •
Capital Hotel at RAK • Muscat City Center • Fujairah City Center • Ajman
City Center • Qatar • American School • ABM Military School • State
Security Bureau – Doha HQ • Doha Bank Head Quarters – West Bay •
Kahramaa Tower – West Bay • Doha City Centre • Al Madina Hotel •
Doha Convention Centre • MOI Head Quarters • North Gate Mall • Gulf
Mall • Turkish Embassy • Commercial Bank of Qatar HQ • Mazaya
Club house • Merqab Mall • Spinneys at Pearl Qatar • Masraf Al Rayyan
Building • Barwa City Phase • Mosque and Shopping Mall • Barwa City
Phase 1 Amenity - Mosque and Shopping Mall • Ramada / Radisson Blu
Hotel. Saudi Arabia • Correction Facility with MOI - Jeddah, Riyadh
& Taif • Lotus residential tower in Dammam • King Abdulla Project (KAP)
with MOI • Nakheel project in Riyadh • Aircraft Hangers with Ministry of
Defense & Aviation.
India:
Cognizant Technology Solutions • TATA AIG • McKinsey & Company •
Ashok Tower • Mumbai Cricket Academy • Bharti Airtel • Edelweiss •
CapeGemini • DigiCable • Jewel Mall • Sheth Corporate Tower • Banke
Bihari Temple • Holy Spirit Hospital • Automotive Research Association
of India • Goldman Sachs • TCS • Mansoft Systems • JP Morgan
• Adesh Tyagi’s Residence • Holistic Infrastucture Ltd. •
Harper Tech Pvt. Ltd. • Suzlon •
Vodafone • Future Generally
• IBIS • Novotel • JNPT
Office • Dahisar
Church • Honda
Factory • New
Era School • VLCC • Viner PMC Consultant • BEHR Paints • Vesta Hotel
• Trident Oberoi • Pawan Hans Helicopters • Shoppers Stop • Quest
• Taj Mahal Palace Hotel • Hilton Indus Hotel • Ahmedabad Airport
• Ashok Garden Residential Complex • Holiday Inn • KPMG • Sena
Bhavan • NASA Corporate Office • Lodha Bellisimo Residential Complex
• Lotus IT Park • Financial Technology Corporate Office • Cosy Resort
• Rajasthan Sammelan • Nanded Yeshwantrao Chauhan Museum •
Synergy • Dawn Mills • Columbia Asia Hospitals • Jamia Milia Indoor
Stadium• ADP • Toyota Bidadi • Wankhede Stadium • MCA Stadium •
Avinash Bhonsale Corporate Building • R K Puram Residential Complex
• Daman Casino • RPG • Citious Eclipsys • ASF Insignia • Asia Management School • ARA • The Capital Corporate Office • Lady Hospital •
Nokia • Citrix R & D Centre • Wells Fargo • Kongu Engineering College
• Amazon • Infinite Computers • Mewat Medical College • Mahila
Viswavidhyalaya • R.K Puram Cpwd Residential Society • Ashoka Hotel
• Radisson Hotel • Wyndhamn Hotel Delhi • Isbt Bus Terminal •
Pawan Hans Helipad • Commonwealth Games Village • Tata Capital •
Tata Motors • Wyndhamn Hotel Delhi • World Trade Centre • Orion Mall
• Brigade Office N Food Court • Bhuvneshwar Airport • Bnp Paribas •
Raipur Railways • Kolkata Airport • Vadodara Airport • Hexaware • Aga
Khan Academy • Jsw • Faureca • Inautix • Kga Hotel Kerala • Sabic
Pharma • Century Mills • Century Bhavan • Cgo Complex • All India
Institute of Medical Sceince, Bhopal (AIIMS).
Denmark:
The Crowne Plaza i Part, Copenhagen • Crowne Plaza Hotel Copenhagen ( Copenhagen Towers ) Opening nov 2009 • H&M Main Store
Amagertorv, Copenhagen • Føtex Food Hasseris, Aalborg • Føtex Food
Guldsmedegade, Aarhus • DS Centralstock, Aarhus • H&M Nørrebro,
Copenhagen • H&M, Odense • Panum Institute, Copenhagen.
Germany:
Deutsche Oper, Berlin • Bayrische Staatskanzlei, München • Kongresscenter, Würzburg • Fraunhofer Umsicht, Oberhausen • Heeresflugplatz,
Roth • Handels-Lehr-Anstalt, Bruchsal • Deutsches Luft- und Raumfahrtzentrum, Oberpfaffenhofen • Hauptbahnhof Darmstadt, Darmstadt •
Campus Westend, Johann Wolfgang Goethe-Universität, Frankfurt am
Main.
UK:
Royal festival Hall • Royal Halls, Harrogate • Victoria sq, Belfast •
Tallagh centre, Dublin • Snow hill • BASF Chemical plant, Midlands •
Lewisham Civic centre • Eltham Leisure centre Bahaus store, Iceland •
PFI Schools, Scotland • St Mirrens Stadium • White city Station • Derby
Shopping Centre • Derby Theatre.
Belgium:
North Galaxy, Brussels • European Parliament, Brussels • Exxon
Mobile, Brussels • Grain cake Bakery, Ath n Galery Theater Arenberg,
Brussels • Imagimons, Mons • Carrefour, Belgium • Bierset Airport,
Liège • Axa Bank, Brussels • Cynagogue de Forest, Brussels • Swift
La hulpe, Brussels • Fire station, Brussels • Fire station, Liège • Musée des beaux arts, Mons • Hospital, Mouscron • Galerie Anspach,
Brussels • Kempinski Hotel, Bruges.
Switzerland:
M1 and M2 subway lines,Lausanne • Universität, Sankt Gallen •
Shopping mall and football stadia, Neuchâtel • Hôpitaux Universitaires,
Genève • Pictet bank, Geneva • Theater, Sankt Gallen • Tramway
maintenance center, Basel • Notre-Dame church, Vevey • Airport,
Zürich.
Portugal:
Batalha Cathedral • Stella Maris Pavillion • Guarda Cathedral • Amadora Church.
Hong Kong:
Hong Kong Airport, Hong Kong.
Norway:
Bjørnholt VG skole, Oslo • HIBU (Highschool), Drammen • Gjøvik Olympic Arena, Fjellhallen, Gjøvik • Med vennlig, Hilsen.
Slovakia:
SAMSUNG LCD factory, Voderady • HANSOL LCD, Voderady • BANG
JOO Electronics, Šurany • JMT SK, Hlohovec.
France:
Rolland Garros stadium, Paris • Air France Roissy Headquarter, Paris
• France Stadium, Paris • St Exupery airport, Lyon • Department
Hall, Marseille • Pharo cultural center, Marseille • Communal headquarter, Marseille • Borely Hippodrome, Marseille • Congress Hall,
Dijon • Auditorium, Dijon • Mediacenter, Montpellier • Zenith, Pau
• Futuroscope, Poitiers • Merignac Airport, Bordeaux • Palais des
sports, Grenoble • Department Hall, Bastia • Congress Hall, Toulon •
Zenith, Toulouse • Airport St Martin, Antilles • Zara shops, Paris, Lyon,
Bordeaux, Marseille • St Microelectronics Plant, Grenoble • Caisse
d’epargne, bank Lyon • RATP line 11 symphonie, Paris • RER Nation/
Etoile station, Paris • SNCF railway stations, Metz, Besançon, Aix les
Bains, Lyon Perrache, Frejus-St Raphael, Charleville Mézières, Mulhouse, Montluçon, Le Havre, Brive, Voiron, Villefranche sur saône, Ouest
Lyonnais, Sarrebourg, Chambery, Brest, Morlaix, St Brieuc, Guingamp,
Valence ville, Hazebrouk, Roanne, Paris Nord, Paris Est, Nîmes, Marseille
St Charles, Monaco, Antibes, Angers, Lyon Part Dieu, Nancy stations •
TGV railway station East • Commercial Mall “Grand Littoral”, Marseille •
Nice côte d’azur T2, Airport • Footbal stadium, Grenoble • TRAM TRAIN,
Aulnay Bondy •Grimaldi forum, Monaco.
South Africa:
ABSA 160 Main • ABSA 170 Main Road JHB • Edgewood College •
Fairlands Office Development • Foschini Stanley Lewis Center • Kendal
Power Station • IDC Building Sandton • Melrose Arch New Car Park •
Parc Du Cap n Momentum HQ-Centurion • Nedbank BOE n Spar Distribution • Colloseum • Africa House • Cavendish Connect • SA NAVY n
ABSA 270 Main • UCT Woman Res.
Portugal:
Conference Rooms in the Hotel & Casino of “Chaves” • City of Chaves •
“Colombo” Shopping, Lisbon • Conference Room of “Carcavelos”
local hall, Village of Carcavelos •
Conference Room of
“Academia Militar” School, Lisbon •
City Hall swimming
pool of “Covilhã”, City of Covilhã •
“LUZ” Stadium systems improvement (Benfica Football
Club Stadium), Lisbon.
Italy:
Battistero del Duomo, Pisa • SanMiracoli, Casalbordino, Chieti
Maria della Scala in San
dele, Milano • Duomo
Gambarare,
Mira,
Venezia.
tuario Madonna dei
•
Santa
Fedi
ATEÏS Middle East FZCO.
P. O. Box 293640 Dubai United Arab Emirates
Tel: +971 4 3262730 - Fax: +971 4 3262731
www.ateis.ae
info@ateis.ae
ATEÏS Europe B.V.
ATEÏS France S.A.S
ATEÏS Suisse S.A.
Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDS
Phone: +31 (0)10 2088690 - Fax: +31 (0)10 2088699
www.ateis-europe.com
info@ateis-europe.com
34, av de l’europe - ZA de Font Ratel - 38640 Claix - FRANCE
Phone: +33 (0)4 76 99 26 30 - Fax: +33 (0)4 76 99 26 31
Sales: +33 (0)4 76 99 26 37
www.ateis-france.fr
contact@ateis.com
Chemin du Dévent, 1024 Ecublens - SWITZERLAND
Phone: +41 (0)21 881 25 10 - Fax: +41 (0)21 881 25 09
www.ateis.ch
info@ateis.ch
ATEÏS USA.
ATEÏS Germany GmbH.
ATEÏS CHINA
21 Sabin St. Pawtucket, RI 02860 - USA
Phone: 401-727-1600 - Fax: 401-727-0003
info@penton-usa.com
Kirchenstrasse 11 – 82194 Gröbenzell – DEUTSCHLAND
Phone: +49 (0) 8142 305070-30 – Fax: +49 (0) 8142 305070-39
www.ateis-germany.de
info@ateis-germany.de
Room 610, No. 255 Wubao Road, Minxing district
Shanghai - CHINA
Phone: 021-54495191/92 - Fax: 021-54495193
www.ateis.com.cn
ATEÏS Far East CORP.
ATEÏS Middle East FZCO.
ATEÏS SE PTE Ltd.
2F, No.60, Xing Hua 2nd Rd., Taizi, Taichung county, 427 TAIWAN, R.O.C.
Phone: +886 4 25333820 - Fax: +886 4 25333830
www.ateis.com
sales@ateis.com.tw
LIU 11 Dubai - Silicon Oasis - DUBAI UNITED ARAB EMIRATES
Phone: +971 4 3262730 - Fax: +971 4 3262731
www.ateis.ae
info@ateis.ae
Blk 209 New Upper - Rd #04-631 - SINGAPORE 460209
Phone: +65 6456 4448 - Fax: +65 6451 3426
www.ateis-europe.com
ashley@ateis-se.com.sg
Was this manual useful for you? yes no