Power. Sheet.
Power. Sheet.
6CRV220
THE POWER OF 1
AGM Deep Cycle
VRLA AGM | Non-Spillable | Maintenance-Free
Crown Battery Manufacturing’s team of product and application experts
welcome the opportunity to discuss your technical requirements during
the design and specification stage. To access this support, please contact:
Crown Battery Manufacturing’s
Product Support Department
+1.419.334.7181 / Fax +1.419.334.7124
commercial@crownbattery.com
TERMINAL STYLE
Standard
PHYSICAL SPECIFICATIONS
BCI
Group
Size
Model
Description
Nominal
Voltage
GC2
6CRV220
6
Container
Height
Terminal
Height
in
mm
in
mm
in
mm
in
mm
lbs
kgs
Cover &
Container
Material
10.25
260
7.06
179
9.70
246
10.94
278
66
29.9
Polypropylene
Length
Width
Weight
Case to Cover
Seal Method
Heat Seal
ELECTRICAL SPECIFICATIONS
Ampere Hour Capacity (Ah)
Discharge Capacity Minutes
KWH (kWh)
Int Res.
Short Circuit Current
CCA
CA
100 Hr
20 Hr
5 Hr
75A
25A
20A
15A
5A
100 Hr
80°F / 27°C
Amperes
675
840
230
220
172
105
415
553
803
3330
1.34
1.06
3620
AGM BATTERY STATE OF CHARGE MEASUREMENT
State of Charge Percentage
100%
75%
50%
25%
0%
Open Circuit Voltage - Cell
2.14
2.09
2.04
1.99
1.94
Open Circuit Voltage - Battery
6.42
6.27
6.12
5.97
5.82
APPLICATION NOTES
Operating Temperature Range
Self Discharge
Terminal & Torque Specifications
Best Practices
Maximum Limit -4°F to 120°F
(-20°C to 49°C) with proper temperature
compensation controls. Lead acid
batteries are temperature sensitive: refer
to the temperature / capacity projection
chart to identify available capacity at the
application operating temperature.
Approximately 3% per
month at 80°F (27°C).
SAE / Automotive Terminal:
50 to 70 in-lbs / 6 to 8 Nm
Stainless Threaded Terminal:
100 to 120 in-lbs / 11 to 14 Nm
Fastener Type:
5/16”-18 S/S Keps Hex Nut/
Star Washer
Battery terminal connections
should be secured and tight at all
times. Replace torn or damaged
cabling or connectors.
Safety is Your Responsibility! Keep sparks, flames and cigarettes
away from batteries at all times. Maintain good ventilation when
working on or charging batteries.
Rate of self discharge
will vary depending on
storage temperature.
Application Note: Maintain a state
of charge greater than 60% when
operating batteries at temperatures
below 32°F (0°C).
14 4 5 Maje stic Drive
|
P.O. Box 9 9 0
|
Fremont, OH US A
|
Keep batteries and terminal connections clean, dry and free of dirt and
corrosion. Do not tamper with vent structures. Optimize the life of your
batteries by limiting duty cycle depth of discharge to 75% or less.
Charging service must be performed with equipment configured to
support the charging recommendations herein. Opportunity charging
service can be performed when batteries are no more than 50%
discharged. Batteries must be fully recharged after the termination of
duty cycle usage.
419.3 3 4.7181
|
Fa x 419.3 3 4.7124
|
w w w.crow nb at ter y.com
6CRV220 AGM Deep Cycle Battery
CYCLIC CHARGING
RENEWABLE POWER CHARGING
Proper charging of renewable power batteries is essential
to optimize the performance and life of the batteries. To
ensure dependability and life batteries should be charged
after each discharge period. Regular monitoring of battery
voltage condition is recommended to verify system recharging
performance. Refer to the following table for additional charge
control setting information.
Constant Voltage Charging
CYCLE CHARGE:
7.20 - 7.41 V
Temperature Correction:
+/- 3 mV / °C
FLOAT CHARGE:
6.60 V
Recommended Charge Current:
25 Amperes
Maximum Charge Current:
65 Amperes
Cyclic applications exceeding 50% depth-of-discharge may require different charger voltage set points.
Contact Crown Battery to discuss your application requirements.
DEPTH OF DISCHARGE EFFECT ON CYCLE LIFE
75% DOD
Cycles
End-Cycle
Voltage
50% DOD
Cycles
End-Cycle
Voltage
25% DOD
Cycles
End-Cycle
Voltage
550
5.97
1000
6.12
2400
6.27
The battery life references presented above are estimations based upon life cycle testing conducted at Crown Battery Manufacturing’s Test Center
in Fremont, Ohio USA. The data references are nominal and should not be construed as maximum or minimum values for specifications or final
design. Data for this product type may vary from that shown herein, and Crown Battery makes no warranties based upon the data shown above.
Voltage
Setting
VPC
Bulk
System Voltage
12 Volts
24 Volts
48 Volts
2.44
14.64
29.28
58.56
Absorption
2.42
14.52
29.04
58.08
Float
2.20
13.20
26.40
52.80
Effect of Ambient Temperature
on Battery Life
Typical battery life is based upon a baseline operating
temperature of 80°F / 27°C. Temperature increases
of 15°F / 10°C over the baseline will cause the
battery’s rate of internal chemical reactions to double
– something that will reduce battery life due to the
accelerated deterioration of internal components.
Please contact Crown Battery to discuss any minimal
requirements for battery life when operating batteries
in temperatures greater than 80°F / 27°C.
10.94 (278)
9.70 (246)
10.25 (260)
7.06 (179)
The data shown are nominal and should not be construed as maximum or minimum values for specification or final design.
Data for this product type may vary from that shown herein.
©2016 Crown Battery Manufacturing Company
1445 Majestic Drive | P.O. Box 990
Fremont, OH 43420-0990 USA
+1.419.334.7181 | Fax +1.419.334.7124
www.crownbattery.com
commercial@crownbattery.com
Visit our website at www.crownbattery.com
TDS-AGM06220-0416
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising