Rate Contract - Accuster Technologies

Rate Contract - Accuster Technologies
Rate Contract
Government of India
Directorate General of Supplies & Disposals
Jeevan Tara Building, 5 Sansad Marg
New Delhi-110001
Tel Number 23360610/23360537
Digitally signed by:
Sharma Tilak Raj
Email Id:
trsharma.dgsnd@nic.in
Rate Contract no. PCML/AM-4/RC-CD020000/0715/74/NB107/1061
Dated
01-AUG-14
To,
ACCUSTER TECHNOLOGIES PVT. LTD.
PLOT NO. 41,SECTOR-8,MANESAR,GURGAON
GURGAON
Sub: Rate Contract for supply of Portable Compact Mobile Lab
Validity: From 01-AUG-14 To 30-MAR-15 .
Ref:(1) This Office Tender Enquiry No. PCML/AM-4/RC-CD020000/0715/74
Opened on 16-JUL-14.
(2) Your Quotation No. And Dated
.
Dear Sir,
You are hereby informed that your above refered tender read with subsequent letters mentioned above for the Stores
specified in the Schedules annexed has been accepted. This rate contract will be governed by the terms and conditions
brought in the Form no. DGS&D 1001 including DGS&D Arbitration Clause available from DGS&d sales counter
on payment of Rs. 50/- The dispute cannot be referred by the contractor or entertained by facilitation Council or any
other adjudicating forum.The Rate Contract and the schedules annexed here to shall be the sole repository of this Rate
Contract/Transaction.
SCHEDULES ANNEXED
1.Schedule "A" Description of stores,prices,duties/taxes.
2.Schedule "B" special conditions of contract / Other information.
3.Schedule "C" Information to DDOs about parallel rate contracts.
4.Annexure - Technical Specification
5. Schedule "D" - Format of Letter of Authority
"Suspense Account facilities for indentors of Central Civil Ministries/Departments and UT Administration,except for
M/o Defence,M/o Railways and D/o Posts,have been withdrawn with effect from 03.07.2012. As per revised
procedures/guidelines, the indentors are required to place funds at the disposal of O/o Chief Controller of
Accounts(Supply),D/o Commerce,16-A,Akbar Road Hutments,New delhi-110011 in the form of letter of Authority.
The format of Letter of Authority is attached. The indentors are advised to allocate funds to cover the cost of stores
ordered, which includes value of supply orders inclusive of all duties & taxes asper relevent Rate Contract plus 5% of
the value of supply order towards other incidental charges in case of Rate Contract with firm & final prices or 10% of
the value of supply order towards other incidental charges in case of rate contract with price variation clause. In
addition,indentors are also required to include 2.0% of the cost of the stores(i.e value of supply order + incidental
charges) as DGS&D department charges. Supply Order not accompanied with letter of authority in the prescribed
format along with requisite funds shall not be considered as valid supply orders. Ink-signed copy of Letter of
Authority is to be sent to the Office of chief Controller of Accounts(Supply),D/o Commerce,16-A, Akbar Road
Hutments, New Delhi-110011 by Speed Post under intimation to RC holder.Purchase Directorate concerned in
Page 1 of 40
Download Date: 01-AUG-14
DGS&D Headquarters and Inspecting Officer concerned.
The above instructions shall apply to all supply orders placed on or after 03.07.2012."
Yours Faithfully,
(
)
Assistant Director(S)/Section Officer/Dy.Director/Director/DDG(S)
For and on behalf of the purchaser named in the Form DGS&D 1001.
Page 2 of 40
Download Date: 01-AUG-14
COPY TO:
1.The Chief Controller of Accounts,Department of commerce,New Delhi/
COA Mumbai/COA Kolkata,COA Chennai.
(Through authentication cell) This issues with the approval of competent authority.
2.Deputy Director General of Supplies & Disposals,Chennai -10 copies each
3.Deputy Director General of Supplies & Disposals,Kolkata -10 copies each
4.Deputy Director General of Supplies & Disposals,Mumbai -10 copies each
5.Deputy Director General (QA),Kolkata -10 copies each
6.Deputy Director General (QA),Chennai -10 copies each
7.Deputy Director General (QA),Mumbai -10 copies each
8.Deputy Director General (QA),DGS&D -10 copies each
9.Inspection Authority ADG(QA) DGS&D New Delhi - 110001.
10.Quality assurance Officer Director (QA) Delhi Directorate/ Mumbai,Chennai/Kolkata.
11.Concurrent Audit
12.MIS Cell
13.Ledger clerk
14.O.L.Section
15.All Direct Demanding Officers as per mailing list maintained by DGS&D.
16.Concerned CQA(for defence item only)-As per Clause 19 of RC
17.Concerned SQAO(for defence item only)-As per Clause 20 of RC
(
)
Assistant Director (S) / Section Officer / Deputy Director/Director/DDG(S)
FOR DIRECTOR GENERAL OF SUPPLIES & DISPOSALS
Page 3 of 40
Download Date: 01-AUG-14
SCHEDULE - A
1.Rate Contract No.:-PCML/AM-4/RC-CD020000/0715/74/NB107/1061
Dated 01-AUG-14 For the Supply of Portable Compact Mobile Lab
2.Advance Rate Contract No.:Dated
3.(a) Name and Full Address of the Firm :ACCUSTER TECHNOLOGIES PVT. LTD.
PLOT NO. 41,SECTOR-8,MANESAR,GURGAON
GURGAON
HARYANA - 122050
Tel. No. - 08527895901,08527895900
Fax - -Email - support@accuster.com
(b) Name and Full Address of Manufacturer :Plot No. 41, Sector-8, IML Maneser, GURGAON, HARYANA-122050
(c) Brand: ACCUSTER
4.Validity of Rate Contract: 01-AUG-14 To 30-MAR-15
5.Description of Item, Specification,Unit, Rate
--------------------------------------------------------------------------------------------------------------------------------------------Item Model
Store Description
Unit
Rate
No. No.
(in Rs)
ED
ED%
CST/VAT CST/VAT% Service Tax
--------------------------------------------------------------------------------------------------------------------------------------------1
Description of Equipment: Portable compact NOS.
mobile lab with Accurate All
Main Equipment
N.A
Min.Order Qty(in unit):- 1
2
Page 4 of 40
Main Equipment
Excl.
Lead Time(in days):-45
327075
Rs. THREE
LAKHS
TWENTYSEVEN
THOUSAN
D
SEVENTYFIVE ONLY
5.25
Rate of Supply(monthly):-50
Description of Equipment: Portable compact NOS.
mobile lab with Accukine
362675
Rs. THREE
LAKHS
SIXTYTWO
THOUSAN
D SIX
HUNDRED
SEVENTYFIVE ONLY
Download Date: 01-AUG-14
N.A
Min.Order Qty(in unit):- 1
3
Main Equipment
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Main Equipment
Main Equipment
NOS.
Excl.
Lead Time(in days):- 45
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
436100
Rs. FOUR
LAKHS
THIRTYSIX
THOUSAN
D ONE
HUNDRED
ONLY
5.25
Description of Equipment: Accurate All
Analyzer
Min.Order Qty(in unit):- 1
Page 5 of 40
5.25
Description of Equipment: LaBike
N.A
Main Equipment
Excl.
273675
Rs. TWO
LAKHS
SEVENTYTHREE
THOUSAN
D SIX
HUNDRED
SEVENTYFIVE ONLY
Rate of Supply(monthly):-50
Min.Order Qty(in unit):- 1
7
Rate of Supply(monthly):-50
Lead Time(in days):- 45
N.A
Main Equipment
238075
Rs. TWO
LAKHS
THIRTYEIGHT
THOUSAN
D
SEVENTYFIVE ONLY
5.25
Description of Equipment: Portable compact NOS.
mobile static lab with Accukine
Min.Order Qty(in unit):- 1
6
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
N.A
5
5.25
Description of Equipment: Portable compact NOS.
mobile static lab with Accurate All
N.A
4
Excl.
NOS.
67195
Rs. SIXTYSEVEN
THOUSAN
D ONE
HUNDRED
NINETYFIVE ONLY
5.25
Rate of Supply(monthly):-50
Description of Equipment: Accukine
Analyzer
NOS.
107690
Rs. ONE
LAKHS
SEVEN
THOUSAN
D SIX
Download Date: 01-AUG-14
HUNDRED
NINETY
ONLY
N.A
Min.Order Qty(in unit):- 1
8
Lead Time(in days):- 45
Lead Time(in days):-
2500
Rs. TWO
THOUSAN
D FIVE
HUNDRED
ONLY
N.A
Distance Slab: Above 1,000 Kms
NOS.
Spares - PCML
Excl.
13.13
Rate of Supply(monthly):-50
Spare Description: Incubator Wire
NOS.
Excl.
Lead Time(in days):- 45
N.A
Min.Order Qty(in unit):- 1
Rate of Supply(monthly):-50
NOS.
Excl.
Lead Time(in days):- 45
98
Rs.
NINETYEIGHT
ONLY
13.13
Spare Description: Sensor
Spares - PCML
1470
Rs. ONE
THOUSAN
D FOUR
HUNDRED
SEVENTY
ONLY
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Spares - PCML
Rate of Supply(monthly):-50
Spare Description: Incubator PCB + Display NOS.
Spares - PCML
5000
Rs. FIVE
THOUSAN
D ONLY
N.A
Lead Time(in days):- 45
N.A
Page 6 of 40
NOS.
Freight Chgs(Including
boarding,lodging &
onetime onsite training
for main equipment)
Min.Order Qty(in unit):- 1
14
Rate of Supply(monthly):-
Rate of Supply(monthly):-50
N.A
13
0
Rs. ZERO
ONLY
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
12
NOS.
Min.Order Qty(in unit):- 1
N.A
11
Rate of Supply(monthly):-50
Distance Slab: 500 to 1000 Kms
Freight Chgs(Including
boarding,lodging &
onetime onsite training
for main equipment)
N.A
10
5.25
Freight Chgs(Including
Distance Slab: Below 500 Kms
boarding,lodging &
onetime onsite training
N.A
for main equipment) N.A
Min.Order Qty(in unit):-
9
Excl.
490
Rs. FOUR
HUNDRED
NINETY
ONLY
13.13
Rate of Supply(monthly):-50
Spare Description: Incubator Switch
NOS.
49
Rs. FORTYNINE
Download Date: 01-AUG-14
ONLY
N.A
Min.Order Qty(in unit):- 1
15
Spares - PCML
Rate of Supply(monthly):-50
Spare Description: Analyzer PCB
NOS.
Min.Order Qty(in unit):- 1
Spares - PCML
Spare Description: Display Screen
NOS.
Spares - PCML
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Spares - PCML
Excl.
Lead Time(in days):- 45
NOS.
4900
Rs. FOUR
THOUSAN
D NINE
HUNDRED
ONLY
13.13
Rate of Supply(monthly):-50
NOS.
490
Rs. FOUR
HUNDRED
NINETY
ONLY
13.13
Rate of Supply(monthly):-50
Spare Description: USB Port (to connect
laptop)
Min.Order Qty(in unit):- 1
Page 7 of 40
Excl.
Lead Time(in days):- 45
N.A
Spares - PCML
Rate of Supply(monthly):-50
Spare Description: Fuse along with holder
N.A
20
Excl.
784
Rs. SEVEN
HUNDRED
EIGHTYFOUR
ONLY
13.13
Spare Description: Inbuilt Printer circuit
Min.Order Qty(in unit):- 1
19
Excl.
Lead Time(in days):- 45
N.A
18
13.13
Rate of Supply(monthly):-50
Min.Order Qty(in unit):- 1
Spares - PCML
Excl.
19600
Rs.
NINETEEN
THOUSAN
D SIX
HUNDRED
ONLY
Lead Time(in days):- 45
N.A
17
13.13
Lead Time(in days):- 45
N.A
16
Excl.
NOS.
1960
Rs. ONE
THOUSAN
D NINE
HUNDRED
SIXTY
ONLY
13.13
Rate of Supply(monthly):-50
Spare Description: Mobile Lab power Circuit NOS.
2940
Rs. TWO
THOUSAN
D NINE
HUNDRED
FORTY
ONLY
Download Date: 01-AUG-14
N.A
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
21
Spares - PCML
Spares - PCML
NOS.
Spares - PCML
Page 8 of 40
Excl.
Lead Time(in days):- 45
NOS.
4900
Rs. FOUR
THOUSAN
D NINE
HUNDRED
ONLY
13.13
Rate of Supply(monthly):-50
NOS.
Spare Description: Mobile lab fitting
Min.Order Qty(in unit):- 1
Spares - PCML
Excl.
Lead Time(in days):- 45
N.A
26
Rate of Supply(monthly):-50
Spare Description: Outside Battery Pack (2
batteries)
Min.Order Qty(in unit):- 1
1470
Rs. ONE
THOUSAN
D FOUR
HUNDRED
SEVENTY
ONLY
13.13
Excl.
Lead Time(in days):- 45
N.A
25
13.13
Excl.
Spare Description: Inbuilt Battery
Min.Order Qty(in unit):- 1
Spares - PCML
1470
Rs. ONE
THOUSAN
D FOUR
HUNDRED
SEVENTY
ONLY
Rate of Supply(monthly):-50
N.A
24
NOS.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Spares - PCML
1470
Rs. ONE
THOUSAN
D FOUR
HUNDRED
SEVENTY
ONLY
Rate of Supply(monthly):-50
Spare Description: Power Supply AdapterIncubator
N.A
NOS.
13.13
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
23
Rate of Supply(monthly):-50
Spare Description: Power Supply AdapterAnalyzer
N.A
22
13.13
Excl.
11760
Rs.
ELEVEN
THOUSAN
D SEVEN
HUNDRED
SIXTY
ONLY
13.13
Rate of Supply(monthly):-50
Spare Description: Mobile Lab Main Switch
NOS.
490
Rs. FOUR
HUNDRED
NINETY
Download Date: 01-AUG-14
ONLY
N.A
Min.Order Qty(in unit):- 1
27
Spares - PCML
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Spares - PCML
Spares - PCML
Excl.
490
Rs. FOUR
HUNDRED
NINETY
ONLY
13.13
Rate of Supply(monthly):-50
NOS.
245
Rs. TWO
HUNDRED
FORTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
NOS.
490
Rs. FOUR
HUNDRED
NINETY
ONLY
13.13
Lead Time(in days):- 45
Rate of Supply(monthly):-50
Item Description: Urea (2x50 Ml)
NOS.
N.A
Page 9 of 40
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Reagents - PCML
Excl.
Lead Time(in days):- 45
N.A
Min.Order Qty(in unit):- 1
980
Rs. NINE
HUNDRED
EIGHTY
ONLY
13.13
Spare Description: Outside Solar Panel
Connector
Reagents - PCML
NOS.
NOS.
Min.Order Qty(in unit):- 1
33
Rate of Supply(monthly):-50
Spare Description: Charging Cable
N.A
32
13.13
Spare Description: USB cable
Spares - PCML
14700
Rs.
FOURTEEN
THOUSAN
D SEVEN
HUNDRED
ONLY
Rate of Supply(monthly):-50
Min.Order Qty(in unit):- 1
Spares - PCML
Excl.
NOS.
Lead Time(in days):- 45
N.A
31
Rate of Supply(monthly):-50
Spare Description: Suitcase Wheel Each
Min.Order Qty(in unit):- 1
30
Excl.
Lead Time(in days):- 45
N.A
29
13.13
Spare Description: Mobile Lab outer casing
N.A
28
Excl.
Excl.
Lead Time(in days):- 45
570
Rs. FIVE
HUNDRED
SEVENTY
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Total & Direct Bilirubin
(4X60 ML)
NOS.
860
Rs. EIGHT
HUNDRED
Download Date: 01-AUG-14
SIXTY
ONLY
N.A
Min.Order Qty(in unit):- 1
34
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
N.A
Min.Order Qty(in unit):- 1
N.A
Min.Order Qty(in unit):- 1
38
N.A
Min.Order Qty(in unit):- 1
39
Page 10 of 40
Reagents - PCML
Excl.
Lead Time(in days):- 45
NOS.
954
Rs. NINE
HUNDRED
FIFTYFOUR
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: HDL - Cholesterol
(2X50ML)
Reagents - PCML
2184
Rs. TWO
THOUSAN
D ONE
HUNDRED
EIGHTYFOUR
ONLY
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
NOS.
13.13
Item Description: Creatinine (4X60ML)
Reagents - PCML
1092
Rs. ONE
THOUSAN
D NINETYTWO ONLY
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
NOS.
13.13
Item Description: Triglyceride (5x20ML)
Reagents - PCML
394
Rs. THREE
HUNDRED
NINETYFOUR
ONLY
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
NOS.
13.13
Item Description: Cholesterol (5x20ML)
Reagents - PCML
Min.Order Qty(in unit):- 1
37
Rate of Supply(monthly):-50
Excl.
Lead Time(in days):- 45
N.A
36
13.13
Item Description: Glucose (2X200 ML)
Reagents - PCML
N.A
35
Excl.
NOS.
578
Rs. FIVE
HUNDRED
SEVENTYEIGHT
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Uric Acid (5x20 ML)
NOS.
1307
Rs. ONE
THOUSAN
D THREE
HUNDRED
SEVEN
Download Date: 01-AUG-14
ONLY
N.A
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
40
N.A
N.A
43
N.A
44
Reagents - PCML
45
Reagents - PCML
Min.Order Qty(in unit):- 1
Excl.
Lead Time(in days):- 45
NOS.
1064
Rs. ONE
THOUSAN
D SIXTYFOUR
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Chloride (75 ML)
N.A
Page 11 of 40
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
323
Rs. THREE
HUNDRED
TWENTYTHREE
ONLY
Rate of Supply(monthly):-50
Item Description: Sodium Potassium (30
ML)
N.A
NOS.
13.13
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
423
Rs. FOUR
HUNDRED
TWENTYTHREE
ONLY
Rate of Supply(monthly):-50
Item Description: Alkaline Phosphates (15
ML)
Reagents - PCML
NOS.
13.13
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
665
Rs. SIX
HUNDRED
SIXTYFIVE ONLY
Rate of Supply(monthly):-50
Item Description: Albumin (5X50 ML)
Reagents - PCML
NOS.
13.13
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
323
Rs. THREE
HUNDRED
TWENTYTHREE
ONLY
Rate of Supply(monthly):-50
Item Description: Calcium OCPC (2X50
ML)
Reagents - PCML
NOS.
13.13
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
42
Rate of Supply(monthly):-50
Item Description: Magnesium KIT (25 ML)
Reagents - PCML
N.A
41
13.13
Excl.
NOS.
437
Rs. FOUR
HUNDRED
THIRTYSEVEN
ONLY
13.13
Rate of Supply(monthly):-50
Download Date: 01-AUG-14
46
Item Description: Total Protein (5X50 ML)
Reagents - PCML
N.A
Min.Order Qty(in unit):- 1
47
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Reagents - PCML
Reagents - PCML
Excl.
532
Rs. FIVE
HUNDRED
THIRTYTWO ONLY
13.13
Rate of Supply(monthly):-50
Item Description: SGPT (150 ML)
NOS.
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Excl.
Lead Time(in days):- 45
Excl.
532
Rs. FIVE
HUNDRED
THIRTYTWO ONLY
13.13
Rate of Supply(monthly):-50
NOS.
475
Rs. FOUR
HUNDRED
SEVENTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Phosphorus (75 ML)
N.A
Page 12 of 40
1092
Rs. ONE
THOUSAN
D NINETYTWO ONLY
13.13
Item Description: Haemoglobin (1000 ML)
Reagents - PCML
NOS.
Lead Time(in days):- 45
N.A
53
Rate of Supply(monthly):-50
NOS.
Min.Order Qty(in unit):- 1
52
13.13
Item Description: SGOT (150 ML)
N.A
51
1092
Rs. ONE
THOUSAN
D NINETYTWO ONLY
Rate of Supply(monthly):-50
Min.Order Qty(in unit):- 1
Reagents - PCML
Excl.
NOS.
Lead Time(in days):- 45
N.A
50
Rate of Supply(monthly):-50
Item Description: ALT (SGPT Kinetic)
(5X20 ML)
Reagents - PCML
N.A
49
Excl.
413
Rs. FOUR
HUNDRED
THIRTEEN
ONLY
13.13
Item Description: AST (SGOT Kinetic)
(5X20 ML)
Reagents - PCML
N.A
48
Excl.
NOS.
NOS.
608
Rs. SIX
HUNDRED
EIGHT
ONLY
13.13
Min.Order Qty(in unit):- 1
Lead Time(in days):- 45
Rate of Supply(monthly):-50
Consumables - PCML
Item Description: Washing System
NOS.
906
Download Date: 01-AUG-14
Rs. NINE
HUNDRED
SIX ONLY
N.A
Min.Order Qty(in unit):- 1
54
Consumables - PCML
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Consumables - PCML
Consumables - PCML
Consumables - PCML
Consumables - PCML
Excl.
Lead Time(in days):- 45
Rate of Supply(monthly):-50
Min.Order Qty(in unit):- 1
Excl.
Lead Time(in days):- 45
NOS.
475
Rs. FOUR
HUNDRED
SEVENTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
NOS.
475
Rs. FOUR
HUNDRED
SEVENTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
NOS.
2014
Rs. TWO
THOUSAN
D
FOURTEEN
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Micropipette ( 5- 50 ul)
N.A
352
Rs. THREE
HUNDRED
FIFTYTWO ONLY
13.13
Item Description: Battery Pack
Min.Order Qty(in unit):- 1
Page 13 of 40
Excl.
Lead Time(in days):- 45
N.A
Consumables - PCML
NOS.
Item Description: Microtips - Yellow (1000
pc)
Min.Order Qty(in unit):- 1
59
Excl.
Lead Time(in days):- 45
N.A
58
Rate of Supply(monthly):-50
Item Description: Microtips - Blue (500 pc)
Min.Order Qty(in unit):- 1
57
Excl.
Lead Time(in days):- 45
N.A
56
13.13
Item Description: Cuvette Box
N.A
55
Excl.
NOS.
4750
Rs. FOUR
THOUSAN
D SEVEN
HUNDRED
FIFTY
ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Micropipette - (100 - 1000 NOS.
ul)
4750
Rs. FOUR
THOUSAN
D SEVEN
HUNDRED
FIFTY
ONLY
Download Date: 01-AUG-14
N.A
Min.Order Qty(in unit):- 1
Consumables - PCML
60
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Consumables - PCML
Lead Time(in days):- 45
Rate of Supply(monthly):-50
Consumables - PCML
NOS.
Excl.
Lead Time(in days):- 45
Min.Order Qty(in unit):- 1
Consumables - PCML
Excl.
Lead Time(in days):- 45
Rate of Supply(monthly):-50
NOS.
Min.Order Qty(in unit):- 1
Excl.
Lead Time(in days):- 45
1425
Rs. ONE
THOUSAN
D FOUR
HUNDRED
TWENTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
Item Description: Micro Centrifuge Tube
(500 pc)
N.A
2900
Rs. TWO
THOUSAN
D NINE
HUNDRED
ONLY
13.13
Item Description: Cuvettes (100Pcs)
N.A
475
Rs. FOUR
HUNDRED
SEVENTYFIVE ONLY
13.13
Item Description: Solar Panel 20 W
Min.Order Qty(in unit):- 1
63
NOS.
Excl.
N.A
62
Rate of Supply(monthly):-50
Item Description: Tip Box
N.A
61
13.13
NOS.
475
Rs. FOUR
HUNDRED
SEVENTYFIVE ONLY
13.13
Rate of Supply(monthly):-50
6-Terms of Delivery:
Delivery at site on freight to pay basis. Freight Charges for items
8,9 & 10 shall be paid extra for distance slabs mentioned under
SCHEDULE - A.
7-Excise Duty:
As indicated against each item under clause 5 above
8-Sales Tax:
As indicated against each item under clause 5 above
9-Delivery Period:
As indicated against each item under clause 5 above
10(a)-Annual Turnover:
2010-11 48.1 Rs. in Lac
2011-12 108.52 Rs. in Lac
2012-13 330.93 Rs. in Lac
(b)-Monetary Limit(In Rs.):
11-Payment Terms:
Page 14 of 40
16600000
80% against inspection of stores(wherever applicable) and
provisional receipt of stores by consignee,and balance 20% on
acceptance.
Download Date: 01-AUG-14
12-Slab Discount Clause:
13-Prices:
14-Quantity Offered:
NIL
FIXED
NA
15-Minimum Quantity in Single Supply Order:
16-Minimum order Value in Single Supply Order:
17-Status of the RC Holding Firm:
SSI
18-Paying Authority:
(a)The payment to the suppliers in all the adhoc Contract
(A/Ts) and / or Supply Order placed against DGS&D Rate
Contracts shall be made directly by indentors i.e. order placing
authotity through their concerned Pay & Accounts Offices only,
instead of CCA(Supply) or its Regional Pay & Accounts
Offices of Department of Commerce.
(b)The payment to the supplier shall be paid by the indentors as
per prescribed forms of payments including timelines for
payments within 60 days of due date which must be ensured by
the indentors.Delays,if any, in this regard would render the
indentors responsible and not the DGS&D in any manner
whatsoever.
(c)Consequently,the requisite Departmental charges +
prevailing Service Tax thereon shall be deposited by the
respective Pay & Account offices (PAO) of the indentors
directly to the Receipt Head Account of DGS&D as prescribed
by CGA.
(d)Indentors shall be directly responsible for any noncompliance/default for the afore-said provisions.
19-Inspection Authority:
20-Quality Assurance Officer/Inspecting officer:
21-Place where the Stores are to be Tendered
for Inspection:
Plot No. 41, Sector-8, IML Maneser, GURGAON,
HARYANA-122050.
22-R/C is DDOs Operated:
Yes
With effect from First October two thousand eight ( 01-10-2008 ),all supply order(s) against this Rate Contract must
be placed by Direct Demanding Officer(s) on-line through D.G.S&D web site (www.dgsnd.gov.in) (indentor's page) only.
Supply order(s) in any other form placed on or after 01-10-2008 shall not be valid and shall not be acted upon by the
contractor or any other concerned agencies.
DDO shall download the supply order and send an ink signed copy to the concerned paying authority specified in the
rate contract through Registered / speed post immediately after on-line placement of Supply Order(s).
23-Packing & Specification :
see annexure
24- Departmental Charges : Departmental charges at the rates prescribed by government from time to time shall be
levied,for the services rendered by the Directorate General of Supplies and Disposal,in regard to Purchase & Inspection.
The rates currently applicable for departmental charges in regard to purchase and inspection of stores against DGS&D
R/C.
24(a) For Purchase : - Departmental Charges will be levied @1.0% of the value of the contract or supply order placed
against the DGS&D rate contract.
24(b) For Inspection :- Departmental Charges will be levied @1.0% of the value of the contract or supply order placed
against the DGS&D rate contract.
Page 15 of 40
Download Date: 01-AUG-14
24(c). The value of the Contract or Supply Order shall be all inclusive basis including all taxes & duties. Service tax at
prevailing rate as applicable shall be chargeable as extra on the Departmental Charges.
24(d) Such direct/referral Supply Orders being placed by various Government users on Rate Contract holding firms or
their dealers/sub agents,obtaining supplies and making direct payments to the firms for the cost of stores prescribed in the
Rate Contracts are liable to pay a nominal fee as Departmental Charges @0.25% of the value of Supply Order (all
inclusive including taxes & duties ) + Service Tax extra as applicable. After receipt of Supply Order,the firm will deposit
the said Departmental charges + service tax thereon at the rates provided in the R/C to the concerned Controller of
Accounts (CCA) viz. Delhi/Mumbai/Kolkata/Chennai, as the case may be ,as indicated in the R/C by way of Demand
Draft/Bank Transfer. In case , the supplies are made in installments, the aforesaid Departmental charges + Service Tax
can be paid by the firm with CCA on pro-rata basis based on the value of the supplies made. In case no supplies are made,
Departmental charges would not be payable / claimable as no service would deem to have been rendered by DGS&D.
The firms can claim Departmental charges from PAO of the indentor for the direct/referral orders placed by them.Those
who err/conceal/misrepresent/default in payment of prescribed Department Charges would be viewed adversely and shall
be liable for actions as deemed fit by DGS&D including de-registration,debarring or suspension of business
dealings,blacklisting , bad performance and denial of further Rate Contracts etc, in addition to recovery of the requisite
amounts.IT would be the responsibility of the user department to ensure that the prescribed departmental charges have
been paid by the supplier before releasing their payments for the supplies. The firm would also disclose the same to
DGS&D.
24(e) The Referral /Direct Orders placed by the indentor by tweaking DGS&D Rate Contract terms & condition and/or
Specifications and obtaining the supplies within 1% of the DGS&D Rate Contract prices, such transactions will fall
within the purview of DGS&D Rate Contract and will also attract the aforesaid Departmental Charges @0.25% of the
value of stores ordered and supplied alongwith applicable Service Tax thereon.
24(f) In the event of placing such Referral/Direct Supply Orders, indentors shall send e-mail to DGS&D for which a
special provision would be provided on DGS&D website. While the indentors placing on-line Supply Order on DGS&D
e-procurement portal shall have the protection under the terms & conditions of DGS&D Rate Contract, the same would
not be available in case they choose to place paper Supply Order and such transactions would be at their own risk.
(
)
Asstt. Director (S) / Section Officer / Dy. Director
For and behalf of the purchaser named in the Form DGS&D 1001.
All the R/C particulars including prices in respect of individual R/Cs are available on DGS&D website which can be
accessed by all.The DGS&D website is http://dgsnd.gov.in
Page 16 of 40
Download Date: 01-AUG-14
SCHEDULE - B
TEST REPORTS FOR REGISTRATION AND ACCEPTANCE OF GOODS:
In case of products having satisfactory test reports from International Laboratory Accreditation Cooperation (ILAC) or their
worldwide affiliated/recognized labs or NABL approved labs, it would be sufficient to consider the products of requisite quality
for acceptance without insistence for any further testing pursuant to DGS&D Manual Correction Slip No. 38 dated 18-12-2012.
Other Information
SPECIAL CONDITIONS
1. This NDP based Rate Contract shall be valid for 12 months.
2. Octroi Duty and Local Taxes shall be extra (only if exemption certificate is not provided by indenter /
consignee).
3. All other terms and conditions shall be as per DGS&D standard terms and conditions contained in DGS&D 68 (R),
DGS&D 1001 and DGS&D 229.
4 Guaranty/Warranty Certificate : It is certified that the store supplied are brand new, unused, non-refurbished and
original and any full confirm to the technical specifications and description given in the subject Rate Contract. It is
furthert that the supplied stores are covered by the OEM Guaranty/Warranty as per the subject Rate Contract.
5. The yield and rates of the Reagents and Consumables of the respective all 7 main items are optional items DDOs
may carry out their own due diligence including market survey before procuring these consumables.
Special Terms & Conditions
6. AMC CHARGES : It is Optional for the consignee to avail the AMC Charges. Same shall be payble per Unit extra on
comprehensive basis for all the parts and consumables and no payment will be made extra for thye same. All spares and
consumables to be suppplied/replaced should be genuine. In case of intermittent failure and repetitive problems due to
improper diagnosis of repair the system will be treated as continuously down.
ii.The service engineers would take up any reported fault within same day. As far as possible, the repairs would be
carried out on site itself. However, in case the equipment is taken to the workshop, the firm would provide a standby for
the same. The firm will also provide maintenance and repair services on holidays in case of emergency.
iii. If any Comact Portable Lab is not repaired within two days, the firm will provide a standbyComact Portable Lab. If,
however the firm fails to repair or provide a standby machine within 2 days, that a penalty of Rs.200/-(Rupees two
hundred only) per day or part thereon will be charged for delay beyond the two days till such time Comact Portable Lab
is repaired. In case the parts that require replacement, is not available, the same should be replaced with a higher level of
part that is compatible with the system.
iv. No advance payment in any case would be made. However, quarterly payment after completion of each quarter
would be made on production of satisfactory reports from the concerned users.
v. Firm shall have to deposit an amount of Rs. 50,000/- (Rupees Fifty Thousand only) as security deposit in the form of
Fixed Deposit Receipt (FDR) in the appropriate form in favour consignees and valid for the period of contract. The
security deposit will be released on completion of the contract. Backing out act in midstream without any explicit
consent of consignee would automatically debar the firm from any further dealing and the Security deposit would also
be forfeited. AMC charges aplicable after completion of standered guarantee/waranty are given below
Page 17 of 40
Download Date: 01-AUG-14
a. 1st year after warranty period @ 3% of the cost of the equipment
b. 2nd year after warranty period @ 4% of the cost of the equipment.
c. 3rd year after warranty period @ 5% of the cost of the equipment.
d. 4th year after warranty period @ 6% of the cost of the equipment.
7. INSPECTION : For stores procured against DGS&D Rate Contract the Inspection will be carriedout by User
Departments/DDO/Consignee itself or any authority/agency appointed by them.
Page 18 of 40
Download Date: 01-AUG-14
SCHEDULE - C
List of Parallel Rate Contract For Portable Compact Mobile Lab
Sr.No.
NAME & FULL ADDRESS OF FIRM
R/C NO & DATE
1
ACCUSTER TECHNOLOGIES PVT. LTD.
PCML/AM-4/RCCD020000/0715/74/NB107/1061
01-AUG-14
PLOT NO. 41,SECTOR-8,MANESAR,GURGAON
GURGAON
HARYANA
122050
NOTE:
(1) Before placing supply order, DDOs are advised to check with DGS&D or on the website whether any further RCs
have been awarded or amendments to Rate Contract have been issued.
(2) All the R/C particulars including prices in respect of individual R/C's are available on DGS&D website,which can
be accessed by all. The access code of DGS&D website is http://dgsnd.gov.in.
Page 19 of 40
Download Date: 01-AUG-14
ANNEXURE
Main Equipment
Specification :
Item 1
SPECIFICATIONS OF Mobile Lab PORTABLE COMPACT MOBILE BIOCHEMISTRY LABORATORY
MODEL : PCML - ALL
(ISO-9001,ISO-13485:2003, CE Marked and FITT Certified)
Portable Automated Biochemistry Laboratory - Open System.
It is of True Random Access with Direct Reading System.
PORTABLE COMPACT MOBILE LAB WITH BATTERY and SOLAR POWER BACK UP: LABORATORY IN
SUITCASE
ENCLOSING following items considered as 1 unit.
ACCURATE-ALL
Parameters
- Blood Analyzer
(36 investigations LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,
Indirect Bilirubin,Globulin,Albumin /Globulin Ratio, RBC,PCV,MCV,MCH,MCHC
a)Wave Length Range
:
410 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accuracy
:
Up to 3 decimal places.
e)Optical System (Photo Detector): Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption. requires less calibration Light source is much more
stable against the lamp because fluctuation in voltage will not effect
performance of the equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it more reliable andmaintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL The minimum known volume required,
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
<700 gm
r)Dimensions (in mm) :
<262 X 120 X 92
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
1)CENTRIFUGATION UNIT
Page 20 of 40
Download Date: 01-AUG-14
a)Fixed Angle Rotors
:
b)Adapter
:
c)Speed
:
d)Safety Provision
:
e)Slots to keep centrifuge
f)Operation
g)Power Supply
h)Dimension (in mm)
6 x 1.5 ml
Adapter for 0.2 ml & 0.5 ml tubes
6000 RPM
Lid interlocking
tubes : 8+ adapter of 16
:
:
:
Quick acceleration to full speed.
230V AC ±10%, 50Hz.
Diameter- 131.5 ,Height -128
:
:
:
:
:
:
:
Between 25°C (ambient temperature) to 45°C
Mica.
PID Controller
Simple at the user end.
230V AC ±10%, 50Hz.
Diameter-155.5 , Height -80 mm
25 samples incubation at one time
:
:
2.5ml
100
:
:
:
25 X 4 cuvettes
4, made of plastic
4
2)INCUBATION UNIT
a)Temperature Selection
b)Heating Material
c)Heating Control
d)Sensor Calibration
e)Power supply
f)Dimensions
g)Capacity
3)CUVETTES
Sample Capacity
Quantity
4)CUVETTE STAND
Carrying Capacity
Stand Cap
Quantity
5)MICROPIPETTES
a)Measuring Volume Range : 5-50ul
b)Measuring Volume Range : 100-1000ul
6)MICRO TIPS
Microtips
Quantity
(sample capacity):
:
Macrotips
Quantity
(sample capacity):
:
5-50ul
1000
100-1000ul
500
7)MICRO TIP BOX
:
2
a)Micro Box
b)Macro Box
:
:
100 insertions
100 insertions
8)REAGENTS CONTAINERS
Carrying capacity
: 10 Units
9)BLOOD CENTRIGUGE TUBE
Sample capacity
Quantity
:
1.5 ml
:
500
10)Centrifuge tubes stand fixed in the platform
:
15
11)OVERALL SPECIFICATIONS
Page 21 of 40
Download Date: 01-AUG-14
a)Power supply
: 230V AC ±10%, 50Hz.
b)Solar Power to run all components : 40-100 watt
Solar Panel :
Photonex/Tata BP/Power Tech/Equivalent brand
c)Battery POWER BACK-UP of 4 hours provided via one inbuilt battery and one
external battery pack.
External battery can be charged through any external dc power source like vehicle
etc.
d)Suitcase backside has 3 ports for AC , external battery(12 volt DC) and Solar
panel connection
e)Dimensions (in mm)
: 685 X 470 X 285.
f)Power circuit is powered by AC supply-230/110 volt , DC /battery supply - 12
volt and Solar panel(40- 100 watt) as well.
g)All the equipments (analyzer, centrifuge ,incubator) working on different power
sources are distinctively placed on single unbreakable platform in coordination
with each other inside the suitcase.
12)PATIENT MANAGEMENT SOFTWARE Version II Accurate All 10.0.1 Prerequisites
USB Driver
: Prolific USB Driver (PL-2303 USB-to-serial)
Microsoft Office
: XP , 2007 or above (licensed)
Database
: MS-Access 2007
Java Runtime Environment 1.6 or 1.7
Dropbox For syncing purpose.
Processor
: IntelCore,DualCore,Core2Duo,Atom,i3,i5.
Internet Connection At the time of Installation and syncing
Direct data transfer from Analyzer to data recorder and Reports can be generated
on organisation letter head and stored on laptop which can be used for future
reference.
13)Mini Laptop /Data Recorder loaded with PMS Version II : ASUS / ACER /HP/
Equivalent Brand
Window
based
RAM
1 GB or More
Hard Disk
320 GB or More
Processor
Dual core or Above
Operating System Windows 7 (32 bit)
14)CONNECTIVITY CABLE
:
2
USB PORT - Data Cable , Charging Cable.
15 ) Washing System :
made of plastic with 25 nozzles with bottle turner .
To be used in washing 25 cuvettes at one time
16)CASE / MOBILE CARYING PLATFORM
It is a suitcase comprising of :
1.Unbreakable Top plate : made of imported plastic where other componets of mobile
lab(centrifuge, incubator, cuvette stand, reagent stands, centrifuge tube stand)
are framed.
2.Bottom plate : made of imported plastic where batteries and power circuit are
framed
3.Bags placed in the upper lid of the suitcase to keep consumables.
17) RUCKSACK BAG
Page 22 of 40
Download Date: 01-AUG-14
It is a cover bag accommodating Mobile lab having 2 straps so as to carry it on
shoulders.
Dimensions : 635 mm x 290 mm x 480mm
18) Open System : Reagents from different sources can be utilized.
19) Batteries :
Luminous/Microtek/Intex/Zebronics /Equivalent brand
Type: LEAD ACID
Capacity : 7.2 Ah
1 Internal inbuilt battery
2 External battery
List of deliverables
Item 1 Model : PCML-ALL
Particulars
Accuster Mobile Lab Portable Compact Mobile Lab comprising the following
1.Accurate All Analyzer-USB port
2.Centrifuge
3.Power Backup (Designed for at least 4 hrs. backup)
4.Incubator
5.Case / Mobile Carrying Platform
6.Cover Bag/Rucksack bag
7.Cuvettes
8.Centrifuge Tubes
9.Cuvette Holder
10.Micropippette (5-50uL )-Accuster
11.Micropippette (100-1000uL )-Accuster
12.Microtips
13.Micro tip Holder
14.Patient Management Software
15.USB port for data connectivity, data cable , charging cable
16.Reagents Pack consisting of the following :-
QTY
a)KFT (Kidney Function Test) includes Urea /Uric Acid/Creatinine
b)LFT (Liver Function Test) includes Albumin/Total Bilirubin
c)Lipid Profile includes Cholesterol, HDL / Triglycerides
d)Diabetes includes Glucose
e)Anaemia includes Haemoglobin
1
1
1
1
1
17 Mini Laptop /Data Recorder loaded with PMS Version II
window based
1
18 Solar Panel
1
1
1
1
1
1
100 pcs
500 pcs
4 pcs
1 pc
1 pc
1500 pcs
2 pcs
1
1
1
Item No 2
SPECIFICATIONS OF Mobile Lab PORTABLE Compact Mobile
Model : PCML - KIN
BIOCHEMISTRY LABORATORY
(ISO-9001,ISO-13485:2003, CE Marked and FITT Certified)
Portable Automated Biochemistry Laboratory - Open System.
It is of True Random Access with Direct Reading System.
PORTABLE COMPACT MOBILE LAB WITH BATTERY and SOLAR POWER BACK UP: LABORATORY IN
SUITCASE ENCLOSING following items considered as 1 unit.
Page 23 of 40
Download Date: 01-AUG-14
ACCU-KIN - Blood Analyzer
Parameters
(37 investigations - LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,Indirect Bilirubin,Globulin,Albumin /Globulin Ratio,
RBC,PCV,MCV,MCH,MCHC,CK-MB
a)Wave Length Range
:
340 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accurac
:
Up to 3 decimal places.
e)Optical System (Photo Detector)
:
Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption.requires less calibration Light source is much more
stable
against the lamp because fluctuation in voltage will not effect performance of the
equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it
more reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
< 1.5 kg
r)Dimensions (in mm)
:
< 280 X 130 X 100
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
1)CENTRIFUGATION UNIT
a)Fixed Angle Rotors
b)Adapter
c)Speed
d)Safety Provision
e)Slots to keep centrifuge tubes
f)Operation
g)Power Supply
h)Dimension (in mm)
:
:
:
:
:
:
:
:
6 x 1.5 ml
Adapter for 0.2 ml & 0.5 ml tubes
6000 RPM
Lid interlocking
8 + adapter of 16
Quick acceleration to full speed.
230V AC ±10%, 50Hz.
Diameter- 131.5 ,Height -128
:
Between 25°C (ambient temperature)
:
:
Mica.
PID Controller
2)INCUBATION UNIT
a)Temperature Selection
to 45°C
b)Heating Material
c)Heating Control
Page 24 of 40
Download Date: 01-AUG-14
d)Sensor Calibration
e)Power supply
f)Dimensions
g)Capacity
:
:
:
:
Simple at the user end.
230V AC ±10%, 50Hz.
Diameter-155.5 , Height -80 mm
25 samples incubation at one time
:
:
2.5ml
100
:
:
:
25 X 4 cuvettes
4, made of plastic
4
:
:
5-50ul
100-1000ul
3)CUVETTES
Sample Capacity
Quantity
4)CUVETTE STAND
Carrying Capacity
Stand Cap
Quantity
5)MICROPIPETTES
a)Measuring Volume Range
b)Measuring Volume Range
6)MICRO TIPS
Microtips
Quantity
(sample capacity)
:
:
5-50ul
1000
Macrotips
Quantity
(sample capacity)
:
:
100-1000ul
500
7)MICRO TIP BOX
:
2
a)Micro Box
b)Macro Box
:
:
100 insertions
100 insertions
:
10 Units
:
:
1.5 ml
500
8)REAGENTS CONTAINERS
Carrying capacity
9)BLOOD CENTRIGUGE TUBE
Sample capacity
Quantity
10)Centrifuge tubes stand fixed in the platform
:
15
11)OVERALL SPECIFICATIONS
a)Power supply
:
230V AC ±10%, 50Hz.
b)Solar Power to run all components
:
40 - 100 watt
Solar Panel :
Photonex/Tata BP/Power Tech/Equivalent brand
c)Battery POWER BACK-UP of 4 hours provided via one inbuilt battery and one
external battery pack.
External battery can be charged through any external dc power source like vehicle
etc.
d)Suitcase backside has 3 ports for AC , external battery(12 volt DC) and Solar
panel connection
e)Dimensions (in mm)
:
685 X 470 X 285.
f)Power circuit is powered by AC supply-230/110 volt , DC /battery supply - 12
volt and Solar panel
(40- 100 watt) as well.
g)All the equipments (analyzer, centrifuge ,incubator) working on different power
Page 25 of 40
Download Date: 01-AUG-14
sources are
distinctively placed on single unbreakable platform in coordination with each
other inside the suitcase.
12)PATIENT MANAGEMENT SOFTWARE Version II - Accurate All 10.0.1 Prerequisites
USB Drive
:Prolific USB Driver (PL-2303 USB-to-serial)
Microsoft Office
:XP , 2007 or above (licensed)
Database
:MS-Access 2007
Java Runtime Environment :1.6 or 1.7
Dropbox For syncing purpose.
Processor
:IntelCore,DualCore,Core2Duo,Atom,i3,i5.
Internet Connection
:At the time of Installation and syncing
Direct data transfer from Analyzer to data recorder and Reports can be generated
on organisation
letter head and stored on laptop which can be used for future reference.
13) Mini Laptop /Data Recorder loaded with PMS Version II :
Equivalent Brand
Window
ASUS / ACER /HP/
based
RAM
Hard Disk
Processor
Operating System
1 GB or More
320 GB or More
Dual core or Above
Windows 7 (32 bit)
14)CONNECTIVITY CABLE
USB PORT -
:
2
Data Cable , Charging Cable.
15 ) Washing System
: made of plastic with 25 nozzles with bottle turner .
To be used in washing 25 cuvettes at one time
16)CASE / MOBILE CARYING PLATFORM
It is a suitcase comprising of :
1.Unbreakable Top plate : made of imported plastic where other componets of mobile
lab(centrifuge, incubator, cuvette stand, reagent stands, centrifuge tube stand)
are framed.
2.Bottom plate : made of imported plastic where batteries and power circuit are
framed
3.Bags placed in the upper lid of the suitcase to keep consumables.
17) RUCKSACK BAG
It is a cover bag accommodating Mobile lab having 2 straps so as to carry it on
shoulders.
Dimensions : 635 mm x 290 mm x 480mm
18) Open System : Reagents from different sources can be utilized.
19) Batteries
: Luminous/Microtek/Intex/Zebronics /Equivalent brand
Type: LEAD ACID
Capacity : 7.2 Ah
1 Internal inbuilt battery
Page 26 of 40
Download Date: 01-AUG-14
2 External battery
List of deliverables
Item 2 Model : PCML- KIN
Particulars
Accuster Mobile Lab Portable Compact Mobile Lab comprising the following
1. Accukine Analyzer-USB port
2. Centrifuge
3. Power Backup (Designed for at least 4 hrs. backup)
4. Incubator
5. Case / Mobile Carrying Platform
6. Cover Bag/Rucksack bag
7. Cuvettes
8. Centrifuge Tubes
500pcs
9. Cuvette Holder
pcs
10.Micropippette (5-50uL)
pc
11.Micropippette (100-000uL )
pc
12.Microtips
pcs
13.Micro tip Holder
pcs
14.Patient Management Software
15.USB port for data connectivity, data cable , charging cable
16 Reagents Pack consisting of the following :-
QTY
1
1
1
1
1
1
1
100 pcs
4
1
1
1500
2
1
1
a)KFT (Kidney Function Test) includes Urea /Uric Acid/Creatinine
b)LFT (Liver Function Test) includes Albumin/Total Bilirubin
c)Lipid Profile includes Cholesterol, HDL / Triglyceride
d)Diabetes includes Glucose
e)Anaemia includes Haemoglobin
1
1
1
1
1
17 Mini Laptop /Data Recorder loaded with PMS Version II
window based
1
18 Solar Panel
1
Item No 3
SPECIFICATIONS OF PORTABLE COMPACT STATIC BIOCHEMISTRY LABORATORY
Model : PCSL - ALL
(ISO-9001:2008,ISO-13485:2003, CE Marked and FITT Certified)
System Type
:
Automated Biochemistry Static Laboratory - Open System.
Providing True Random Access with Direct Reading System
PORTABLE COMPACT STATIC LAB: LABORATORY IN SUITCASE ENCLOSING following items
considered
as 1 unit.
1.ACCURATE-ALL - Blood Analyzer
Parameters
(36 investigations - LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Page 27 of 40
Download Date: 01-AUG-14
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,
Indirect Bilirubin,Globulin,Albumin /Globulin Ratio, RBC,PCV,MCV,MCH,MCHC
a)Wave Length Range
:
410 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accurac
:
Up to 3 decimal places.
e)Optical System (Photo Detector)
:
Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption.requires less calibration Light source is much more
stable
against the lamp because fluctuation in voltage will not effect performance of the
equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it
more reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
<700 gm
r)Dimensions (in mm)
:
<262 X 120 X 92
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
1)CENTRIFUGATION UNIT
a)Fixed Angle Rotors
b)Adapter
c)Speed
d)Safety Provision
e)Slots to keep centrifuge tubes
f)Operation
g)Power Supply
h)Dimension (in mm)
:
:
:
:
:
:
:
:
6 x 1.5 ml
Adapter for 0.2 ml & 0.5 ml tubes
6000 RPM
Lid interlocking
8 + adapter of 16
Quick acceleration to full speed.
230V AC ±10%, 50Hz.
Diameter- 131.5 ,Height -128
:
Between 25°C (ambient temperature)
:
:
:
:
:
:
Mica.
PID Controller
Simple at the user end.
230V AC ±10%, 50Hz.
Diameter-155.5 , Height -80 mm
25 samples incubation at one time
2)INCUBATION UNIT
a)Temperature Selection
to 45°C
b)Heating Material
c)Heating Control
d)Sensor Calibration
e)Power supply
f)Dimensions
g)Capacity
Page 28 of 40
Download Date: 01-AUG-14
3)CUVETTES
Sample Capacity
:
2.5ml
5.CUVETTE STAND
Carrying Capacity
:
25 X 4 cuvettes
:
:
5-50ul
100-1000ul
:
:
5-50ul
100-1000ul
6.MICROPIPETTES
Micropipettes Volume Range
Micropipettes Volume Range
7.MICRO TIPS
Microtips sample capacity
Macrotips sample capacity
8.CENTRIFUGE TUBES (sample collection & centrifugation)
Capacity
:
1.5 ml
9.PLATFORM
FRP based plate form
:
60 X 80 cm
10.PATIENT MANAGEMENT SOFTWARE Version II
Direct data transfer from Analyzer to Laptop and Reports can be generated on
organisation
letter head and stored on laptop which can be used for future reference.
Operating system: Window XP, 7, 8
Plateform:Java
Database: MS-Access 2007
Driver: PL-2303 USB-to-serial
Processor:Intel Core,DualCore,Core2Duo,Atom,i3,i5.
11.Mini Laptop /Data Recorder loaded with PMS Version II :
Equivalent Brand
Window based
RAM
Hard Disk
Processor
Operating System
ASUS / ACER /HP/
1 GB or More
320 GB or More
Dual core or More
Windows 7 (32 bit)
12.Power supply
:
230V AC ±10%, 50Hz.
All the equipments (analyzer, centrifuge, incubator) working on different power
sources are
distinctively placed on single unbreakable platform in coordination with each
other inside the
suitcase.
13.CONNECTIVITY CABLE
:
2
USB PORT - Data Cable, Charging Cable.
14.Washing System
: made of plastic with 25 nozzles with
bottle turner
To be used in washing 25 cuvettes at one time
Page 29 of 40
Download Date: 01-AUG-14
15.Wooden CASE / CARYING PLATFORM
It is a suitcase comprising of:
Unbreakable Top plate: made of imported plastic where other components of mobile
lab
(centrifuge, incubator, cuvette stand, reagent stands, centrifuge tube stand)
are framed.Bags placed in the upper lid of the suitcase to keep consumables.
16.Open System
utilized.
: Reagents from different sources can be
17.Overall Dimensions (mm)
:
< 600 x 500 x 180
List of Deliverables
Item 3 Model : PCSL - ALL
Particulars
Accuster Static Lab Portable Compact Static Lab comprising the following
1.Accurate All Analyzer -USB port
2.Centrifuge
3.Incubator
4.Wooden Case
6.Cuvettes
pcs
7.Centrifuge Tubes
pcs
8.Cuvette Holder
pcs
9.Micropippette (5-50uL )
10.Micropippette (100-1000uL
11.Microtips
pcs
12.Micro tip Holder
pcs
13.Patient Management Software
14.charging cable
2 Reagents Pack consisting of the following :a)KFT (Kidney Function Test) includes Urea /Uric Acid/Creatinine
b)LFT (Liver Function Test) includes Albumin/Total Bilirubin
c)Lipid Profile includes Cholesterol, HDL / Triglyceride
d)Diabetes includes Glucose
e)Anaemia includes Haemoglobin
15Mini Laptop/ Data Recorder loaded with PMS Version II
window based
QTY
1
1
1
1
1
100
500
4
1 pc
1 pc
1500
2
1
1
1
1
1
1
1
1
Item No 4
SPECIFICATIONS OF PORTABLE COMPACT STATIC BIOCHEMISTRY LABORATORY
Model : PCSL - KIN
(ISO-9001:2008,ISO-13485:2003, CE Marked and FITT Certified)
System Type
:
Automated Biochemistry Static Laboratory - Open System.
Providing True Random Access with Direct Reading System
PORTABLE COMPACT STATIC LAB: LABORATORY IN SUITCASE ENCLOSING following items
considered as 1 unit.
1.ACCU-KIN - Blood Analyzer
Parameters
(37 investigations - LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Page 30 of 40
Download Date: 01-AUG-14
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,
Indirect Bilirubin,Globulin,Albumin /Globulin Ratio, RBC,PCV,MCV,MCH,MCHC,CK-MB
a)Wave Length Range
:
340 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accurac
:
Up to 3 decimal places.
e)Optical System (Photo Detector)
:
Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption.requires less calibration Light source is much more
stable
against the lamp because fluctuation in voltage will not effect performance of the
equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it
more reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL - The minimum known volume
required,
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
< 1.5 kg
r)Dimensions (in mm)
:
< 280 X 130 X 100
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
1)CENTRIFUGATION UNIT
a)Fixed Angle Rotors
b)Adapter
c)Speed
d)Safety Provision
e)Slots to keep centrifuge tubes
f)Operation
g)Power Supply
h)Dimension (in mm)
:
:
:
:
:
:
:
:
6 x 1.5 ml
Adapter for 0.2 ml & 0.5 ml tubes
6000 RPM
Lid interlocking
8 + adapter of 16
Quick acceleration to full speed.
230V AC ±10%, 50Hz.
Diameter- 131.5 ,Height -128
:
Between 25°C (ambient temperature)
:
:
:
:
:
:
Mica.
PID Controller
Simple at the user end.
230V AC ±10%, 50Hz.
Diameter-155.5 , Height -80 mm
25 samples incubation at one time
2)INCUBATION UNIT
a)Temperature Selection
to 45°C
b)Heating Material
c)Heating Control
d)Sensor Calibration
e)Power supply
f)Dimensions
g)Capacity
Page 31 of 40
Download Date: 01-AUG-14
3)CUVETTES
Sample Capacity
:
2.5ml
5.CUVETTE STAND
Carrying Capacity
:
25 X 4 cuvettes
:
:
5-50ul
100-1000ul
:
:
5-50ul
100-1000ul
6.MICROPIPETTES
Micropipettes Volume Range
Micropipettes Volume Range
7.MICRO TIPS
Microtips sample capacity
Macrotips sample capacity
8.CENTRIFUGE TUBES (sample collection & centrifugation)
Capacity
:
1.5 ml
9.PLATFORM
FRP based plate form
:
60 X 80 cm
10.PATIENT MANAGEMENT SOFTWARE Version II
Direct data transfer from Analyzer to Laptop and Reports can be generated on
organisation
letter head and stored on laptop which can be used for future reference.
Operating system: Window XP, 7, 8
Plateform:Java
Database: MS-Access 2007
Driver: PL-2303 USB-to-serial
Processor:Intel Core,DualCore,Core2Duo,Atom,i3,i5.
11.Mini Laptop /Data Recorder loaded with PMS Version II :
Equivalent Brand
Window based
RAM
Hard Disk
Processor
Operating System
ASUS / ACER /HP/
1 GB or More
320 GB or More
Dual core or More
Windows 7 (32 bit)
12.Power supply
:
230V AC ±10%, 50Hz.
All the equipments (analyzer, centrifuge, incubator) working on different power
sources are
distinctively placed on single unbreakable platform in coordination with each
other inside the
suitcase.
13.CONNECTIVITY CABLE
:
2
USB PORT - Data Cable, Charging Cable.
14.Washing System
bottle turner
Page 32 of 40
: made of plastic with 25 nozzles with
Download Date: 01-AUG-14
To be used in washing 25 cuvettes at one time
15.Wooden CASE / CARYING PLATFORM
It is a suitcase comprising of:
Unbreakable Top plate: made of imported plastic where other components of mobile
lab
(centrifuge, incubator, cuvette stand, reagent stands, centrifuge tube stand)
are framed.Bags placed in the upper lid of the suitcase to keep consumables.
16.Open System
utilized.
: Reagents from different sources can be
17.Overall Dimensions (mm)
:
< 600 x 500 x 180
List of Deliverables
Item 4 Model : PCSL- KIN
Particulars
QTY
Accuster Static Lab Portable Compact Static Lab comprising the following
1
1.ACCU -KIN Analyzer -USB port
1
2.Centrifuge
1
3.Incubator
1
4.Wooden Case
1
6.Cuvettes
100
pcs
7.Centrifuge Tubes
500pcs
8.Cuvette Holder
4
pcs
9.Micropippette (5-50uL )
1 pc
10.Micropippette (100-1000uL
1 pc
11.Microtips
1500
pcs
12.Micro tip Holder
2
pcs
13.Patient Management Software
1
14.charging cable
1
2 Reagents Pack consisting of the following :a)KFT (Kidney Function Test) includes Urea /Uric Acid/Creatinine
1
b)LFT (Liver Function Test) includes Albumin/Total Bilirubin
1
c)Lipid Profile includes Cholesterol, HDL / Triglyceride
1
d)Diabetes includes Glucose
1
e)Anaemia includes Haemoglobin
1
15Mini Laptop/ Data Recorder loaded with PMS Version II
1
window based
Item No 5
Specifications of LaBike
Complete laboratory will be retrofitted on client¿s bike with complete framework
to keep equipments with
bio waste management facility
1 Mobile Lab with Accu - ALL
PORTABLE COMPACT MOBILE LAB WITH BATTERY and SOLAR POWER BACK UP: LABORATORY IN
SUITCASE
ENCLOSING following items considered as 1 unit.
ACCURATE-ALL
Parameters
Page 33 of 40
- Blood Analyzer
(36 investigations Download Date: 01-AUG-14
LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,
Indirect Bilirubin,Globulin,Albumin /Globulin Ratio, RBC,PCV,MCV,MCH,MCHC
a)Wave Length Range
:
410 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accuracy
:
Up to 3 decimal places.
e)Optical System (Photo Detector):Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps
are used thus reduced running
expenses and maintenance.
Very low power consumption.
requires less calibration
Light source is much more stable against
the lamp because fluctuation in voltage will not
effect performance of the equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it more
reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL - The minimum known volume required,
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
<700 gm
r)Dimensions (in mm)
:
<262 X 120 X 92
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage:3000 tests
1)CENTRIFUGATION UNIT
a)Fixed Angle Rotors
b)Adapter
c)Speed
d)Safety Provision
e)Slots to keep centrifuge tubes
f)Operation
g)Power Supply
h)Dimension (in mm)
:
:
:
:
:
:
:
:
6 x 1.5 ml
Adapter for 0.2 ml & 0.5 ml tubes
6000 RPM
Lid interlocking
8 + adapter of 16
Quick acceleration to full speed.
230V AC ±10%, 50Hz.
Diameter- 131.5 ,Height -128
:
Between 25°C (ambient temperature)
:
:
Mica.
PID Controller
2)INCUBATION UNIT
a)Temperature Selection
to 45°C
b)Heating Material
c)Heating Control
Page 34 of 40
Download Date: 01-AUG-14
d)Sensor Calibration
e)Power supply
f)Dimensions
g)Capacity
:
:
:
:
Simple at the user end.
230V AC ±10%, 50Hz.
Diameter-155.5 , Height -80 mm
25 samples incubation at one time
:
:
2.5ml
100
:
:
:
25 X 4 cuvettes
4, made of plastic
4
:
:
5-50ul
100-1000ul
3)CUVETTES
Sample Capacity
Quantity
4)CUVETTE STAND
Carrying Capacity
Stand Cap
Quantity
5)MICROPIPETTES
a)Measuring Volume Range
b)Measuring Volume Range
6)MICRO TIPS
Microtips
Quantity
(sample capacity)
:
:
5-50ul
1000
Macrotips
Quantity
(sample capacity)
:
:
100-1000ul
500
7)MICRO TIP BOX
:
2
a)Micro Box
b)Macro Box
:
:
100 insertions
100 insertions
:
10 Units
:
:
1.5 ml
500
8)REAGENTS CONTAINERS
Carrying capacity
9)BLOOD CENTRIGUGE TUBE
Sample capacity
Quantity
10)Centrifuge tubes stand fixed in the platform
:
15
11)OVERALL SPECIFICATIONS
a)Power supply
:
230V AC ±10%, 50Hz.
b)Solar Power to run all components
:
40 - 100 watt
Solar Panel :
Photonex/Tata BP/Power Tech/Equivalent brand
c)Battery POWER BACK-UP of 4 hours provided via one inbuilt battery and one
external battery pack.
External battery can be charged through any external dc power source like vehicle
etc.
d)Suitcase backside has 3 ports for AC , external battery(12 volt DC) and Solar
panel connection
e)Power circuit is powered by AC supply-230/110 volt , DC /battery supply - 12
volt and Solar panel
(40- 100 watt) as well.
f)All the equipments (analyzer, centrifuge ,incubator) working on different power
sources are
Page 35 of 40
Download Date: 01-AUG-14
distinctively placed on single unbreakable platform in coordination with each
other inside the suitcase.
12)PATIENT MANAGEMENT SOFTWARE Version II - Accurate All 10.0.1 Prerequisites
USB Drive
:Prolific USB Driver (PL-2303 USB-to-serial)
Microsoft Office
:XP , 2007 or above (licensed)
Database
:MS-Access 2007
Java Runtime Environment :1.6 or 1.7
Dropbox For syncing purpose.
Processor
:IntelCore,DualCore,Core2Duo,Atom,i3,i5.
Internet Connection
:At the time of Installation and syncing
Direct data transfer from Analyzer to data recorder and Reports can be generated
on organisation
letter head and stored on laptop which can be used for future reference.
13) Mini Laptop /Data Recorder loaded with PMS Version II :
Equivalent Brand
Window
ASUS / ACER /HP/
based
RAM
Hard Disk
Processor
Operating System
1 GB or More
320 GB or More
Dual core or Above
Windows 7 (32 bit)
14)CONNECTIVITY CABLE
USB PORT -
:
2
Data Cable , Charging Cable.
15 ) Washing System
: made of plastic with 25 nozzles with bottle turner .
To be used in washing 25 cuvettes at one time
16)CASE / MOBILE CARYING PLATFORM
It is a suitcase comprising of :
1.Unbreakable Top plate : made of imported plastic where other componets of mobile
lab(centrifuge, incubator, cuvette stand, reagent stands, centrifuge tube stand)
are framed.
2.Bottom plate : made of imported plastic where batteries and power circuit are
framed
3.Bags placed in the upper lid of the suitcase to keep consumables.
17) Open System : Reagents from different sources can be utilized.
18) Batteries
: Luminous/Microtek/Intex/Zebronics /Equivalent brand
Type: LEAD ACID
Capacity : 7.2 Ah
1 Internal inbuilt battery
2 External battery
18)Accessories
1) Portable Fridge
2) Microscope
3) Portable PC Based ECG-12 Lead
19) Small cabins to keep the reagents and the equipments
Page 36 of 40
Download Date: 01-AUG-14
a) Side Cabins (qty 2)
: <24'x16'x14'
(Front lid should make platform with 90 degree fall with support of chain)
Sliding tray column with various compartments in it
b) Top Cabins
: <28'x16'x14'
(top side rotatable solar panel 180 degree)
Both side panel after 90 degree rotation should make platform with side chains
front panel should also make platform with base support.
20) Ultra Portable foldable tent house to cover entire Laboratory work
Instant pop up tent :
base 5.5 ft and centre height 7 ft 6inces
Weight less than 5 kg
Seam taped Rainfly
Instant Pitching in 9 secs
Groundsheet included ,Foldable Chairs : 2
List of Deliverables
Item 5 :LaBike
Particulars
Qty
Accuster laBike comprises the following
1
2
3
4
Microscope
1
Serology Kits
1
PC Based ECG
1
Mobile Lab ,PCML ALL comprises following
Accurate All Analyzer-USB port
1
Centrifuge
1
Power Backup (Designed for at least 4 hrs. backup)
1
Incubator
1
Case / Mobile Carrying Platfom
1
Cuvettes
100 pcs
Centrifuge Tubes
500pcs
Cuvette Holder
4 pcs
Micropippette (5-50uL)
1 pc
Micropippette (100-1000uL)
1 pc
Microtips
1500 pcs
Micro tip Holder
2 pcs
Patient Management Software
1
USB port for data connectivity, data cable , charging cable
1
5 Reagents
Pack consisting of the following :-
KFT (Kidney Function Test) includes Urea /Uric Acid/Creatinine
LFT (Liver Function Test) includes Albumin/Total Bilirubin
Lipid Profile includes Cholesterol, HDL / Triglycerides
Diabetes includes Glucose
Anaemia includes Haemoglobin
Mini Laptop /Data Recorder loaded with PMS Version II
window based
6 Solar Panel
1
1
1
1
1
7 Portable Cold Storage Unit/Fridge
8 Instant Pop Up Tent
1
1
1
1
Item No 6
Specifications of ACCURATE-ALL - Biochemistry Semi Auto Blood Analyzer
Page 37 of 40
Download Date: 01-AUG-14
Model : ACC-ALL
ACCURATE-ALL - Blood Analyzer
Parameters
(36 investigations - LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,Indirect Bilirubin,Globulin,Albumin /Globulin Ratio,
RBC,PCV,MCV,MCH,MCHC
a)Wave Length Range
:
410 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accurac
:
Up to 3 decimal places.
e)Optical System (Photo Detector)
:
Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption.requires less calibration Light source is much more
stable
against the lamp because fluctuation in voltage will not effect performance of the
equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it
more reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL - The minimum known volume
required,
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
<700 gm
r)Dimensions (in mm)
:
262 X 120 X 92
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
Item No : 7
Specifications of ACCUKINE - Biochemistry Semi Auto Blood Analyzer
Model : ACC - KIN
ACCU-KIN - Blood Analyzer
Parameters
(37 investigations - LFT,KFT,Lipid,Electrolytes,Glucose,Hematology):
Egfr, Glucose, Hb,Urea,Uric acid, SGOT,SGPT, Creatinine, Cholesterol, Total
Bilirubin,
Direct
Bilirubin,TotaProtein,Calcium,Chloride,Sodium,Potassium,LDL,HDL,ALP,Albumin,
Triglyceride,Magnesium,Phosphorus,BUN UREA /RATIO ,BUN,LDL Calculative, VLDL,
HDL/LDL Ratio,Indirect Bilirubin,Globulin,Albumin /Globulin Ratio,
RBC,PCV,MCV,MCH,MCHC,CK-MB
Page 38 of 40
Download Date: 01-AUG-14
a)Wave Length Range
:
340 - 650 nm,
b)Calibration
:
Multi Point Calibration
c)Measuring Modes
:
%Transmission, Absorbance
d)Photometric Accurac
:
Up to 3 decimal places.
e)Optical System (Photo Detector)
:
Silicon Photodiode
f)Display
:
Bright Green LCD display
g)Keyboard
:
Soft push-membrane type
h)Have measurement range from 0.001 to 2.300 Abs
i)Light Source
:
Patented Solid State Chip based
LED which has long life, no Lamps are used thus reduced running expenses and
maintenance.
Very low power consumption.requires less calibration Light source is much more
stable
against the lamp because fluctuation in voltage will not effect performance of the
equipment.
j)Filters
:
No Filters are used.
k)It is microprocessor based and above all based on virtual filter technology
which makes it
more reliable and maintenance free for future.
l)Sample System
:
10mm path length Cuvette based
m)Sample Volume Required
:
5 µL - The minimum known volume
required,
n)Printer Output Device
:
In built thermal printer available
o)Power Supply
:
12V DC ±10%, 50Hz.
p)USB Port
:
Connectivity to Laptop
q)Weight
:
< 1.5 kg
r)Dimensions (in mm)
:
< 280 X 130 X 100
s)No pump system required for flow cell which reduces complexity and
delicacy in sample reading and sample analysis.
t)ISO Certified, CE marked
u)US FDA Registered
v)Internal Memory of test storage
:
3000 tests
Freight Chgs(Including boarding,lodging & onetime onsite training for main
equipment)
Specification :N.A.
Spares - PCML
Specification : Detail given in GTR
Reagents - PCML
Specification :N.A.
Consumables - PCML
Specification :N.A.
Page 39 of 40
Download Date: 01-AUG-14
LIST OF ALL AMENDMENTS
For RC No. PCML/AM-4/RC-CD020000/0715/74/NB107/1061
NOTE: No Amendments issued till date 01-AUG-14
Page 40 of 40
Download Date: 01-AUG-14
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project