custom power design
_________________________________________________________________________________________________________________________________________________________________________________
CUSTOM POWER DESIGN
ELECTRONICS CONSULTANTS PROVIDING CUSTOM DESIGN, DEVELOPMENT, TEST & SUPPORT
_________________________________________________________________________________________________________________________________________________________________________________
Tel: + 44 (0)118 930 2113/2299
A DIVISION OF SMET LTD
Fax: +44 (0)118 930 2206
_________________________________________________________________________________________________________________________________________________________________________________
www.custompowerdesign.co.uk
Unit 2, The Markham Centre, Station Road, Theale, Berks. RG7 4PE.
custom@custompowerdesign.co.uk
‘HANDY MAINS’ 700W HIGH SURGE STATIC INVERTER.
MODEL
SM3496
SM3497
SM3498
SM3499
BATTERY
12V
12V
12V
12V
SOCKET
UK 13A AND UK 13A
DOUBLE EURO SHUKO
UK AND EURO SHUKO
UK AND IEC 320 C13
MODEL
SM3506
SM3507
SM3508
SM3509
BATTERY
24V
24V
24V
24V
SOCKET
UK 13A AND UK 13A
DOUBLE EURO SHUKO
UK AND EURO SHUKO
UK AND IEC 320 C13
___________________________________________________________________________________________________________________________________________________________________________________
accommodating starting surge for motors, microwave use
and aggressive use of power tools.
The battery input is via internal 5mm stud terminals. The unit
may be turned off and on remotely, by a low current control
input to a 6.35mm spade terminal. An earth stud is fitted on
the outside of the box for chassis connection.
BATTERY SELECTION: Only heavy duty (high discharge
rate) batteries are suitable as a power source. Fully sealed
types should be used in enclosed spaces (especially inside
the home). Ordinary car batteries are only suitable in well
ventilated areas.
SPECIFICATION:
12V TYPES
24V TYPES
Battery:
12V nominal.
24V nominal.
Voltage Range:
11V - 14.5V.
21.6V - 30V.
Current, No Load:
0.5A
0.35A
Per 10W loading:
1A
0.5A
Remote On/Off:
The units draw <1mA until the
control input is connected to
battery positive.
INPUT
Temporary Outdated Picture. The unit now includes an on/off switch.
•
•
•
•
•
•
SWITCH SELECT 230V / 115V AC OUTPUT
BUILDING SITE USE (110V RANGE).
RUNS SMALL MICROWAVES AND FRIDGES.
HIGH OUTPUT POWER IN COMPACT SIZE.
HIGH CONVERSION EFFICIENCY.
REMOTE ON / OFF CONTROL FACILITY.
GENERAL DESCRIPTION. Small floor mounting converters,
available with other input and output voltages, generating
mains level power, capable of powering most small office or
laboratory equipment from any 12 or 24 volt battery system
They are particularly aimed at small refrigerators and
microwave ovens.
Dual outlet sockets are fitted to the unit (see model numbers
for details). The input may be isolated from chassis The
output is isolated via a safety barrier from the input.
The output is a stepped odd function wave AC output of
nominally 230V/115V RMS Switchable, with a peak voltage
appropriate to mains, corresponding to a quasi sine wave.
This output, suitable for switched mode supplies, is required
for machines employing a mains transformer, making it
suitable for almost all equipment.
The specification allows for up to 700 watts of continuous
power to be used, with short surges up to 1200 watts,
OUTPUT
Output Voltage:
115/230V ± 10% RMS selectable
Frequency:
50Hz nominal, 48Hz to 53Hz.
Output Wave Form:
Quasi sine wave.
Power, Nominal:
700 Watts continuous (resistive).
Power, Short term:
1050 Watts for 5 minutes.
1200Watts for 10 seconds.
Protection:
Current and temperature limit.
GENERAL
Size:
Weight:
170mm x 155mm x 180mm.
7.4 Kg.
Storage Temperature:
Operating Temperature:
-40 to +70C.
-40 to +35C.
Manufacturer:
Made in the United Kingdom
___________________________________________________________________________________________________________________________________________________________________________________
CAUTION: This adaptor is supplied on the basis of the user determining the suitability for the purpose for which it is to be used. Do not use in a
moving vehicle without the consent of the vehicle maker. Do not use for aviation or marine applications without written agreement. Do not use for
life dependent applications. The negative input lead is connected to case and output ground making the unit suitable only for negative earth systems.
We reserve the right to change the specification without notice
Document 3498-993
_______________________________________________________________________________________________________________________________________________
SMET Limited. Registered in England & Wales, Number 6760677.
Registered .Office: Bell House, Ashford Hill Road, Ashford Hill, Berks. RG19 8BB.
VAT No. (GB) 944 0645 24