GEM-II Multi-Purpose Gas Detector

GEM-II Multi-Purpose Gas Detector
Self Contained - GAS DETECTION DATASHEET
GEM-II Multi-Purpose Gas Detector
technical drawing
F I XE D S YS TE M DATA S H E E T
GEM-II multi-purpose gas detector represents excellent value for the
end user. They are available in one or two channel configurations
accommodating accurate “smart” sensors and providing a wide range of
features. These features include CSA, UL and C-Tick certifications, RoHS
compliant circuit boards, two 5-amp dry contact relays, electronic
adjustable set points, audible alarm, time delays, analog output,
pluggable wiring terminal, rugged polycarbonate enclosure with hinged
door, Lexan label, and optional 4-digit display.
KEY FEATURES
» Single or dual channel operation
» Network multiple units
» Integral or remote sensors
» Integral plug and play “smart” sensors
» 4 - 20 mA linear output signal
» Three conduit entry ports
» Thermal resetting fuse
» LED light indicators
» Two 5-amp SPDT relays
» RoHS compliant circuit boards
» Economical
» CSA & UL certified
APPLICATIONS
» Parking Garages
» Repair Shops
» Ice Cleaning Machine Rooms
» Manufacturing Plants
» ... and many more
GEM-EECO-END-NJ model (picture to the right)
contains two integral sensors, carbon monoxide
(CO) & nitrogen dioxide (NO2), enclosed in a
standard PVC enclosure with a LED digital display
and 120 VAC transformer attached.
sample engineering specifications
Vehicle Exhaust Detection System for Carbon Monoxide & Nitrogen Dioxide
Supply a dual channel, self-contained gas detection system, model GEM-EECOEND, for the monitoring of carbon monoxide (gas engine exhaust) and nitrogen
dioxide (diesel engine exhaust), housed in a rugged, wall mount, dripproof PVC
enclosure with hinged, secured door. System power shall be 24 VAC nominal.
The system shall have two integral electrochemical sensors, one CO with
measurement range of 0 - 200 ppm CO in air and one NO2 with measurement
range of 0 - 10 ppm NO2 in air. Area of monitoring coverage is up to 5,000 7,000 ft2 per sensor.
The monitor shall provide an LED indicating light for power, low alarm, high
alarm, and fault condition plus channel indication LEDs, one audible alarm
with silence push-button and two SPDT dry contact alarm relays, each rated 5
A at 240 VAC. The system must be accurate enough to measure to government
workplace hazardous gas exposure standards. The system shall also provide
field adjustable time delays for “delays on make” and “delays on break” for
each sensor to allow custom configuration of fan control by the system relays,
if desired.
The controller shall provide a circuit test button to allow the user to confirm
system operation and exhaust fan control from the panel. The controller shall
also provide a push-button to allow the user to override the system control and
operate exhaust fans continuously for 15-minute segments to evacuate air from
specific parts of the parking garage. Installation height for the gas detection
controller with integral CO & NO2 sensors is 4 - 6 ft from the floor.
System operation shall be as follows: System relays are normally energized in
non-gas-alarm state so they act in failsafe operation. Upon detection of 25 ppm
CO in air or 0.5 ppm NO2 in air, the system shall illuminate the Low alarm LED
(amber) and the low gas alarm relay shall de-energize activating single-speed
exhaust fans or low speed of twospeed exhaust fans plus make up air fans. Upon
detection of 100 ppm CO in air or 2 ppm NO2, the system shall illuminate the
High alarm LED (red), the system audible alarm will be activated and the high
gas alarm relay shall deenergize activating high speed of two-speed exhaust
fans or remote alarm devices. Audible alarm can be silenced from the front
panel push button. In the event of a fail condition, the system audible alarm
shall be activated and the fail LED on the front panel shall illuminate red.
The contractor shall provide all wiring, conduit and interconnection required
for a successful installation. System should be tested and commissioned after
installation, with a report provided after the site visit.
More specification samples are available at www.critical-environment.com.
© February 2013 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | www.critical-environment.com
Self Contained - GAS DETECTION DATASHEET
GEM-II Multi-Purpose Gas Detector
MECHANICAL
Enclosure
Weight
Size
ELECTRICAL
Power Requirement
Current Draw
Wiring
Fuse
INPUT / OUTPUT
Outputs
Relay
General purpose PVC
600 g (1.2 lb)
5.3” x 6.8” x 2.6”
(135 mm x 173 mm x 66 mm)
15 - 30 VDC or 12 - 28 VAC
Approximately 125 mA
VDC three-conductor shielded
VAC four-conductor shielded
Automatic resetting thermal
Linear 4 - 20 mA (single)
Dry contact relays
(2) rated 5 amps @ 240 VAC SPDT
ENVIRONMENTAL (sensor dependant)
Operating Temperature
Humidity
-20°C to 50°C (-5°F to 120°F)
15 - 90% RH non-condensing
CERTIFICATION
CSA
UL
Certified
Certified
product codes
GEM -
-
-
Single / Dual Channel Sensor:
Options:
(You can select more than 1 option)
Type A: Single Channel
None
(Integral Electrochemical)
N
LED digital
AECO
CO sensor (0 - 200 ppm)
display
AEND
NO2 sensor (0 - 10 ppm)
J
Internal 120 VAC
AENO
NO sensor (0 - 100 ppm)
transformer
AEO2
O2 sensor (0 - 25% volume)
AESO
SO2 sensor (0 - 20 ppm)
B
BSCB
BSR2
BSOS
Type B: Single Channel (Remote Solid State Sensor)
No sensor
Combustible gas sensor (0 - 50% LEL)
Refrigerants (R22, R134A, R402A, R404A, R407C,
R410A, R422A, R422D, R507) sensor (0 - 2,000 ppm)
TVOCs sensor (0 - 500 ppm)
DECO-CCB
DECO-ECO
DECO-END
DEO2-EO2
DEND-END
DENO-ENO
Type D: Dual Channel (Integral & Remote Sensor)
Integral CO sensor (0 - 200 ppm) & remote
combustible solid state gas sensor (0 - 50% LEL)
Integral CO sensor (0 - 200 ppm) & AST-CCB
Integral CO sensor (0 - 200 ppm) & LPT-TCO
Integral CO sensor (0 - 200 ppm) & LPT-END
Integral O2 sensor (0 - 25% volume) & AST-OO2
Integral NO2 sensor (0 - 10 ppm) & LPT-END
Integral NO sensor (0 - 100 ppm) & AST-ENO
EECO-END
EECO-ENO
EECO-EO2
EECO-ESO
EEND-ESO
Type E: Dual Channel (Integral Sensors)
CO sensor (0 - 200 ppm) & NO2 sensor (0 - 10 ppm)
CO sensor (0 - 200 ppm) & NO sensor (0 - 100 ppm)
CO sensor (0 - 200 ppm) & O2 sensor (0 - 25% vol)
CO sensor (0 - 200 ppm) & SO2 sensor (0 - 20 ppm)
NO2 sensor (0 - 10 ppm) & SO2 sensor (0 - 20 ppm)
DECO-SCB
ACCESSORIES
Calibration kit for 17, 34, 58, 74, 103 L cylinders, 0.5
LPM flow regulator & adapter to fit 17 L cylinder
Metal protective guard, large, 16 gauge, galvanized
metal guards for controllers
Strobe & horn combo, remote
Enclosed external transformer, 120 - 22 VAC
CET-715A-CK1
SCS-8000-SPG
RSH-24
TIB-2250
© February 2013 Critical Environment Technologies Canada Inc. | Data subject to change without notice. | Toll Free: +1.877.940.8741 | www.critical-environment.com
F I XE D S YS TE M DATA S H E E T
technical specifications
GAS TYPE
Carbon Monoxide (CO)
Combustible Gas (solid state & catalytic)
Hydrogen (H2), Methane (CH4), Propane (C3H8), etc.
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Oxygen (O2)
Refrigerants (solid state)
R22, R134A, R402A, R404A, R407C, R410A, R422A, R422D, R507
Sulphur Dioxide (SO2)
TVOCs (solid state)