Miyoko Macro / Medi / Mini Pendant (Textile)

Miyoko Macro / Medi / Mini Pendant (Textile)
Miyoko Macro / Medi / Mini Pendant (Textile)
Installation, maintenance, use and waste management instructions
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
Technical Information
IP23
Art. no
20720-30 Macro
20720-32 Macro
Lightsource
E27
TC-TEL GX24q-4 42W
Weight
3.5 kg
20730-30 Medi
20730-32 Medi
E27
TC-TEL GX24q-3 32W
5 kg
20740-30 Micro
E27
2.5 kg
UL version available
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
General Installation
Technical data on the internal label.
Luminaire only to be used indoor.
In case of damage, always contact manufacturer before switching on product.
For cleaning instructions, see section ”General Maintenance Recommendations”.
To replace electrical equipment such as LED-module, ballast, etc. please contact manufacturer.
Electronic equipment may be sensitive to voltage surges.
Where applicable installation of a protection device against overvoltage should be used to protect
the luminaire from risk of damage.
In some cases, luminaires are manufactured by hand crafted procedures throughout the process.
Therefore small imperfections might be visible and are part of the luminaire appearance.
In order to protect and maintain the luminaire over time, see section
”General Maintenance Recommendations”.
Modification of the luminaire without written permission is strictly forbidden.
Installation of this luminaire must be carried out by a qualified person in accordance with good
electrical practice and the appropriate national wiring regulations.
Do not use lamps with higher power than indicated.
Disconnect main voltage before maintenance operations.
General Maintenance Recommendations
Luminaires should normally be cleaned in connection with relamping.
Reflective surfaces ought to be cleaned if / when dust or grime is discovered.
Always disconnect the voltage before cleaning, make sure electrical components and cabling is not
exposed to cleaning agent or water.
Use clean antistatic gloves when handling parts that are to be cleaned.
Unpowdered latex gloves to be used during washing.
Wash using a clean cloth, without microfiber or cotton.
Make sure to often change water and cloths.
For high reflective materials, use cleaning leather / compressed air where applicable.
Drying spots might occur when self drying.
In general, indoor luminaires are to be cleaned after 2-3 years. Outdoor luminaires after 5 year.
Contact manufacturer if uncertain.
Recommended cleaning / material in regards of pollution, see below.
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
Part / Material
Normal pollution
Severe Pollution
Means of drying
Lacquered surface
Aluminium
Aluzink
Dust / Vacuum with soft brush.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Use detergent agent, without
bate- or abrasive effect, in
lukewarm water.
Clean with damp cloth.
Wipe with dry, soft antistatic
cleaning or cotton cloth.
Let dry at room temperature.
Aluminum (polished)
Brass
Chrome
Dust / Vacuum with soft brush.
Blow dust with compressed air
where applicable.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Use detergent agent, without
bate- or abrasive effect, in
lukewarm water.
Clean with damp cloth.
Wipe with dry, soft antistatic
cleaning or cotton cloth.
Let dry at room temperature.
Untreated brass
Untreated corten
Untreated copper
Untreated corten
Untreated ore
Untreated materials such as
brass, copper etc. obtain a
patina when oxidizing.
To maintain the oxidized
appearance the surface should
not be polished.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Wipe with dry, soft antistatic
cleaning or cotton cloth.
Let dry at room temperature.
Luminaire body / Shade
Dust / Vacuum with soft brush.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Acrylic
Dust / Vacuum with soft brush.
Blow dust with compressed air
where applicable.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Use detergent agent, without
bate- or abrasive effect, in
lukewarm water.
Clean with damp cloth.
Wipe with dry, soft antistatic
cleaning or cotton cloth.
Let dry at room temperature.
Textile
Dust / Vacuum with soft brush.
Contact manufacturer.
Contact manufacturer.
Wood
Dust / Vacuum with soft brush or
clean cotton cloth.
Dust / Vacuum with soft brush.
Blow dust with compressed air
where applicable.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp cloth.
Contact manufacturer.
Contact manufacturer.
Use detergent agent, without
bate- or abrasive effect, in
lukewarm water.
Clean with damp cloth.
Wipe with dry, soft antistatic
cleaning or cotton cloth.
Dust / Vacuum with soft brush.
Blow dust with compressed air
where applicable.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp antistatic cloth.
Change water and cloth
regularly.
Use neutral detergent agent,
without bate- or abrasive effect,
in lukewarm water.
Clean with damp antistatic cloth.
Change water and cloth
regularly.
Dry with compressed air.
Dust / Vacuum with soft brush.
Blow dust with compressed air
where applicable.
Use a neutral cleaning agent in
lukewarm water. Clean with
damp antistatic cloth.
Change water and cloth
regularly.
Use neutral detergent agent,
without bate- or abrasive effect,
in lukewarm water.
Clean with damp antistatic cloth.
Change water and cloth
regularly.
Wipe with dry, soft antistatic
cleaning cloth.
Glass
Let dry at room temperature.
NOTE! Depending on the
waterquality drying spots might
occur.
Reflectors / Louvres
Anodized aluminium
Polished surfaces
Metallized surfaces.
Lacquered surface
Acrylic louvres
Wipe with dry, soft antistatic
cleaning cloth.
Let dry at room temperature.
NOTE! Depending on the
waterquality drying spots might
occur.
Let dry at room temperature.
NOTE! Depending on the
waterquality drying spots might
occur.
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
Installation Miyoko Macro / Medi / Mini Pendant (Textile)
1.
2.
3.
4.
5.
Make sure that the voltage and frequency of the mains corresponds with the luminaire.
Attach the ceiling attachment.
Connect mains to ceiling attachment.
Connect canopy to ceiling attachment.
Adjust height of luminaire with the wire-gripper (Macro / Medi), cutting of excessive wire.
Adjust height of luminaire with the strain relief (Micro).
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
Waste Management Instructions
WEEE directive
The crossed out wheel-bin that is featured on the label of Your product indicates that this product must not be disposed of via
the normal household waste stream.
To prevent possible harm to the environment or human health, this product should be separated from other waste streams to
ensure that it can be recycled in an environmentally sound manner.
For more information in regards of local collection faciliies, please contact Your local government office or the retailer where
You purchased this product.
©BLOND BELYSNING AB, SILKESVÄGEN 13, 331 53 VÄRNAMO, SWEDEN
www.blond.se
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising