MPR - z-trauq inc.
New Generation Network Analyzers
MPR-4 Series
16MB
Event Records
Pcs / Box
Alarm
Log Records
* *
16MB
16MB
Operating Hours
Meter
*
*
*
*
*
Pulse Counter
*
*
*
*
*
Voltage/Current
Unbalances
*
*
*
*
*
Real Time Clock
*
*
*
*
*
Memory
RS-485
Harmonics 1-51st
Temperature
MPR-47S
96x96
*
*
*
*
*
Pulse Output
96x96
*
*
*
*
*
AO V
96x96
MPR-46S
*
*
*
*
*
Relay Output
MPR-46
AO mA
96x96
Digital Output
96x96
MPR-45S
Digital Input
MPR-4 Series
MPR-45
THD-I
Product Code
THD-V
Dimensions / mm
PRODUCT SELECTION
TABLE
3xV, 3xI, Frequency, W,
VAr, VA,• •P, • •Q, • •S,
kWh, kVArh,Demand,
Max., Min. Cos• •,
I neutral
With their compact design and 45mm depth, MPR-4 series new generation
network analyzers occupy less space in the panels and have a wide range of
operating voltage (45-265 VAC/DC). In addition up to 16 MB internal memory,
they offer wide I/O solutions with their replaceable modular structure based on
customer requirements and areas of application.
*
*
*
* *
Modular structure
Standard
96 x 96 x 45 mm compact design
Voltage / Current unbalance measurement
Modular I / O
Harmonic Measurement up to 51st
256 Event Records
Module Table
96 x 96 x 45 mm
compact design
Modular I / O
0,5
Measurement
Class 0,5
Product
Code
Type
Operating Range
MM-102
Digital Output Module (2DO)
5-24 VDC
MM-120
Digital Input Module (2DI)
5-24 VDC
MM-122
Digital I/O Module (2DI-2DO)
5-24 VDC
MM-144
Digital I/O Module (4DI-4DO)
5-24 VDC
MM-002
Relay Output Module (2 Relays)
5A/250 VAC;NO
MM-202
Analog Output Module (2 AO)
(0-10 VDC) (0-5 VDC) (-5...+5 VDC) (-10...+10 VDC)
(0-20mA) (0-24mA) (4-20mA)
* I/O module can be attached to a single device
Application Areas:
Automation
Industrial
Applications
Energy
Distribution
Data System
Rooms
SPECIFICATIONS
MPR-45S
MPR-45
ENCLOSURE
MPR-46S
MPR-46
MPR-47S
96x96x45mm
Terminals = IP20, Enclosure Protection Class = IP51
LCD, with backlight
Dimensions
Protection Class
Display
MEASUREMENTS
VOLTAGE
Measurement Range
10 - 400 VAC (L-N) 10 - 690 VAC (L-L)
1-400.0 kV Transformer Ratio: 1-5000
1
Measurement Range with Transformer
Accuracy
Input Impedance
Burden (Input Load)
>1M Ω
<0,5 VA
CURRENT
Nominal Current
Minimum Current
Measurement Range
In : 5A / 1A
5 mA
50 mA - 5,5 A Accuracy: 0.5% ± 1 Digit
50 mA -10000 A
0,5 VA
1,2 In continuous
10xIn
Measurement Range with Transformer
Burden
Overload Current
Short Time Overload (1s)
POWER/ENERGY
Active Power
Reactive Power
Apparent Power
Power Factor
Active Energy
Reactive Energy
Total Harmonic Distortion (THD)
Separate Harmonics
Demand Period
Frequency
-
Range: 0 - 1 GW,Accuracy: 1% ± 1 Digit
Range: 0 - 1 GVAr,Accuracy: 1% ± 1 Digit
Range: 0 - 1 GVA, Accuracy: 1% ± 1 Digit
Range: ±1.00, Accuracy : ± 0,02
Range: 0 - 99 999 999 kWh or MWh, Accuracy: 1% 1 class
Range: 0 - 99 999 999 kVArh or MVArh, Accuracy : 2% class 2
THD-V, THD-I
-
Up to 51st Harmonics
1,2,5,10,15,20,30,60 minimum adjustable
45-65 Hz
SUPPLY
45 - 265 VAC/DC
50/60 Hz
<5 VA
PULSE OUTPUT
- 50MWh/pulse)
* Active Energy Output (1kWh/pulse
(1kVArh/pulse - 50MVArh/pulse)
* Reactive Energy Output
50 mA
* Max.
5..24 VDC
* 100 …2500 ms
* Max. 30 VDC
*
Energy Pulse Output
Pulse Width
MEMORY
Internal Memory Size
COMMUNICATION
Communication Interface/Protocol
Transfer Speed
-
16MB
-
16MB
-
RS-485 / MODBUS RTU
2400-115200 bps
-
RS-485 / MODBUS RTU
2400-115200 bps
AMBIENT CONDITIONS
- 5 / +55 C
- 25 / +700C
III
II
90%
0
Operating Temperature
Storage Temperature
Overvoltage Category
Pollution Degree
Ambient Humidity
STANDARDS
EN 61326-1, EN 61557-12, EN 62053, EN 61010-1, EN 61000-6-2
EN 61000-6-4, EN 55011, EN 60068-2
Applied Security Standards
CONNECTIONS
Mounting
Connection Terminals
Connection Types
Front Panel Mounting with Rear Terminals
Screw Terminal with Socket
3P4W, 3P3W, 3 Phase (Aron), 3P4W Balanced, 3P3W Balanced
* Provided with digital output I / O modules
Connection Diagrams PR19 - MPR 4 Series (96x96mm)
MPR-4 Series (3 Phase without
neutral 3P3W connection)
L1
L2
L3
N
L1
L2
L3
N
L1
L2
L3
N
Strommesseingänge
I k
IL3
I k
ILN
Strommesseingänge
k I
k
IL1 I L 2
I
I
k
IL3
I
k
ILN
k I
k
I
IL1 I L 2 L3I L 3L4 I NL N
L1 L2
I
Dimensions
L1
L2
L3
N
Strommesseingänge
Externe
Versorgung
MPR-4 Series (3 Phase connection
in balanced network)
Externe
Versorgung
63
Strommesseingänge
46
Externe
Versorgung
k I
IL1
IL2
IL3
ILN
96
k I k
IL1 I L 2
Externe
Versorgung
MPR-4 Series (3 Phase, Aron
connection)
99
MPR-4 Series (3 Phase neutral
3P4W connection)
Module
L1
L2
Module
Module
L3
L4
N
Spannungsmesseingänge
GND B A TR
L1
RS-485
L1
L2
L3
N
Z-TRAUQ INC.
L2
L3
L4
N
Spannungsmesseingänge
L1
GND B A TR
RS-485
L1
L2
L3
N
www.z-trauq.com
L2
Module
L3
L4
N
Spannungsmesseingänge
L1
L2
L3
N
877-798-9836
GND B A TR
L1
RS-485
L2
L3
L4
N
Spannungsmesseingänge
L1
L2
L3
N
GND B A TR
RS-485
96
TYP PR19
Z-TRAUQ INC./BROYCE
TEL. : (877) 798-7287
FAX :
(877) 479-5878
MPR-50 / MPR-52S / MPR-60S / MPR-63
NETWORK ANALYSERS
Measured Parameters ( MPR-50 )
Phase - Neutral
Voltages (VLN)
Phase - Phase
Voltages (VLL)
Neutral Current
Active Power (P)
Total Current (åI)
Reactive Power (Q)
Power Factor (P.F)
Apparent Power (S)
Cosj
Total Active Power (åP)
Max. Demand
Frequency (Hz)
Total Reactive Power (åQ)
Phase Currents (I)
Max / Min. Values
Total Apparent Power (åS)
Average Phase Neutral Voltage
Average Phase Phase Voltage
Total Harmonic Distortion
for Voltage (THD V %)
Active Energy Import (kWh)
Active Energy Export (kWh)
Reactive Energy Capacitive (kVArh)
Reactive Energy Inductive (kVArh)
Total Harmonic Distortion
for Current (THD I %)
Measured Parameters ( MPR-52S-10 / MPR-60S )
Individual Harmonics
for Voltage - up to 31th
Individual Harmonics
for Current - up to 31th
Measured Parameters ( MPR-63 )
247 DEVICES CAN BE CONNECTED SERIALLY BY USING REPEATERS.
MAX. 1200 mt.
MAX. 1200 mt.
4x0,75 LIYCY cable*
RS485/USB or ETHERNET
CONVERTER
4x0,75 LIYCY cable*
D+ D- GND
CAT 5
Network Cable
...
MPR-52S-10
#247
MPR53CS-96
#246
REPEATER
RPT-1
MPR-60S
#31
MPR-63
#1
* Recommended 4x0,75 LIYCYmm2 cable for RS-485 communications
9
www.z-trauq.com
Bulletin ent110717R0
MPR-50 / MPR-52S / MPR-60S / MPR-63
MODEL
MPR-50
NETWORK ANALYSERS
MPR-52S-10
MPR-63
MPR-60S
SPECIFICATIONS
HOUSING
96x96mm PR19
IP40 Front Panel; IP54 Optional
0,75 kg/device
Backlit 3,6” LCD
Dimensions
Protection Class
Weight
Display
MEASUREMENTS
Voltage
Measuring Range
Measuring Range with Transformer
Accuracy
Input Impedence
Burden
Overload Voltage
1.0-300V AC (L-N); 2.0-500V AC (L-L)
Transformer Ratio: 1.0-4000
%0.5 ± 2 Digit
1.8MΩ
<0.5 VA
1.2 x Measurement Range
Current
In : 5A
5 mA
5 mA - 5,5 AAccuracy: 0.5% ±2 digit
mA 10000 ATransformer Ratio: 1-5000.0
0,5 VA
2xIn
10xIn
Nominal Current
Lowest Current
Measurement Range
Measurement Range with Transformer
Burden
Akım Current
Overload
Discontinuous Overload Current
Power/Energy
0 - 4000 MW
Accuracy: %1 ± 2 Digit
0 - 4000 MVAr
Accuracy: %2 ± 2 Digit
0 - 4000 MVA
Accuracy: %2 ± 2 Digit
±1.00 Accuracy: ± 0,01
0 99 999 999 kWh or MWh
Accuracy: 1% ±2 Digit
0 99 999 999 kVArh or MVArh Accuracy: 1% ±2 Digit
THD V%, THD I%
Active Power
Reactive Power
Apparent Power
Power Factor
Active Energy
Reactive Energy
Total Harmonic Distortion(THD)
Harmonics
Demand/Demand Time
2-31 (V)Voltage and (I)Current
15 min.
Frequency
45-65 Hz
SUPPLY
85 -265 V AC/DC
Operating Voltage
50/60 Hz
<6 VA
Operating Frequency
Power Consumption
INPUT/OUTPUT/SETTINGS
Digital Input
Digital Output
-
2
-
-
-
2 (MPR60S-10/20/40)
2 (MPR60S-21/41)
(0)4-20 mA (MPR60S-40/41; MPR63-40/41/42)
(0)2-10 V DC (MPR60S-20/21; MPR63-20/21)
Analog Output
Contact Output
Energy Pulse Output
-
Delay Time
-
2 (MPR63-10/20/40/42)
2 (MPR63-21/41)
2 NO contacts 5A ; 1250 VA cosj=1.00
Active Energy Output(1kWh/pulse - 50MWh/pulse)
Reactive Energy Output(1kVArh/pulse - 50MVArh/pulse)
Voltage Parameters 0-300 sec.; Current and Power
Parameters 0-900 sec.; Frequency, PF, cos and
Harmonics Parameters 0-600 sec.
PULSE OUTPUT
-
Switching Current
Switching Voltage
Pulse Duration
Maximum Voltage
Max. 50 mA
5..24 V DC
100 …2500 msec.
Max. 30 V DC
MEMORY
-
Data Logging
Capacity
Selectable 28 parameters with Time Stamp(1500 records)
1MB
COMMUNICATION
Interface/Protocol
Transfer Rate
-
RS 485 / MODBUS RTU
-
1200 - 38400
AMBIENT CONDITIONS
Ambient Temperature
- 5 / +550C
Storage Temperature
- 25 / +700C
Overvoltage Category
III
Pollution Degree
Ambient Humidity
II
%90
STANDARDS & APPROVALS
Security Standards
EMC Standards
Approvals
EN-61010-1
EN-61000-6-2, EN-61000-6-4
CSA, CSAus, CE
CONNECTIONS
Installation
Connection Terminals
Connection Types
www.z-trauq.com
Terminal / Flush-mounting with rear terminals
Socket Type Terminal with Screws
3 Phase+Neutral(3P4W), 3 Phase(3P3W), 3 Phase(Aron), 1 Phase
Bulletin ent110717R0
10
Connection Diagrams
When potential transformers are used
* Maintain
CT Polarity
UU
3 Phase 3 wire Delta
..
L3
L2
L1
UU
.
UU
.
.
1
3
5
current inputs
FU
2
2 x PT UUU
UUU
1 phase
UUU
UUU
4
6
.
.
voltage inputs
L1 L2 L3
* Maintain
CT Polarity
3 Phase 4 wire WYE
..
N
L3
L2
L1
.
3 x PT UUUUUU UUU
1 phase UUUUUUUUU
.
N
L1
2 Phase 3 wire
N
.
1
3
5
2
4
6
current inputs
FU
Single phase connection
UU
UU
.
UU
.
voltage inputs
L1 L2 L3 N
.