Video camera boxes flameproof

Video camera boxes flameproof
P.118/121 ANGLAIS
22/10/03
11:07
Page 118
Video camera boxes flameproof
Zone 1 & 2 - 21 & 22
ATEX
IEC
EC
II 2 G/D
IP66
EEx de or EEx d IIB or IIC T6 to T3 T = 127°C IK08/09/10
TECHNICAL DATA
Zones : 1 and 2, and 21- 22
Classification :
• According to CENELEC :
0951 30 camera boxes 475mm
- Conforming to ATEX 94/9 EC Directive and standards EN 50014-18-19
- EC 0081
except Cat. No. 0950 75: EEx de IIB T (* for gas
0951 48 camera
box adjustable
- EC 0081
• Grey painted aluminium alloy box
• Pyrex glass window
• Threaded flameproof joints
• Compatible with any camera model with the following specifications :
- Length compatible with one of the two sizes (475 or 735 mm)
- Max. cross-section of the camera ≤ 127cm2
- Residual energy of the capacitors (before opening): ≤ 20 µJ
- Max. power: 14 W at 240 V 50/60 Hz or 12 V….
• Warm up time (see manufacturer’s instructions)
• Two M20 threaded cable entries
Weight
(Kg)
Volume
(dm3)
Cat. No.
Pack
14.2
18.7
41
61
0951 30
0951 31
1
1
Compact camera boxes IIC
• Two threaded M20 entries at the bottom
• Equipped with a support plate
• 1 toughened glass window, usable ø 84 mm
• 2 internal earths : M4 screw. External earth: M6 screw
• Max. power 10 W
Cat. No.
Pack
3.5
13
0931 55
1
1
2
0931 98
1
Temp. class
For Ta > + 40°C
T5
T3
T6
T6
T5
Approvals :
Type
CENELEC
IEC
Declaration
of conformity
0951 30
0951 31
CAM
03 ATEX 6080
Ex 03.014
50255
0951 48
0931 55
0950 75
PJ70
02 ATEX 6227
Ex 02.020
50239
BR2d
03 ATEX 6062
Ex 03.007
50256
LT2d
02 ATEX 6165
Ex 02.017
50246
- Mechanical resistance (IK code) according to EN 50102
0951 48
Operating temperature : - 40°C to + 55 °C
Dimensions (mm) :
1
67
0931 98
Fixing
accessory for
0931 55
¿
200
144
0931 55
0950 75/80
15
144
150
175
333
506
723
0950 48
• Grey painted aluminium body.
• Toughened glass globe int. Ø 205 mm
• One M20 cable entry via the top
• Max. power 85 W
166
334
360
Ø 338
240
405
0951 30
86.7
0950 75
0950 80
For special options, please consult us
• 4 cable entries on request (Cat. No. 0951 30/31)
Cable glands (see pages 252-263)
Part number in bold : fast moving references
0951 30/31
0951 48
0931 55
0950 75
Gas
Temp. class
For Ta ≤ + 40°C
T6
T4
Anticorrosion treatment and climate protection : see page G50
Camera box with globe for motorised IIB
camera which can be adjusted on site
and in any direction
19
Dust temp.
For Ta = + 40°C
+ 100°C
+ 127°C
+ 85°C
+ 85°C
- 0951 30/31/48 IK10 - 0931 55 IK09 - 0950 75 IK08
• Grey painted aluminium body
• Toughened glass window, usable Ø 155 mm
• Two M20 cable entries, one of which has a blanking plug
• Max. power 70 W (for T6 or T5 requirements, the power must be
reduced. Please consult us)
Camera box with globe
Hinged fixing on ceiling
T (*)temp.
- IP 66 according to EN 60529 and IEC 60529
Volume
27
- DIPA 21 TA = (*)
Protection index :
Weight
8
except Cat. No. 0950 75: Ex d IIB T (*)
Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust
Camera box manually adjustable on site
and in any direction IIC
Adjustable camera box
- Conforming to standards IEC 60079-0/1/7 Ex d IIC T6
1
1
10
Compact camera box
Hinged bracket
for compact camera
II 2 D T = (*) for dust
• According to IEC :
475 and 735 mm video camera boxes IIC
475 mm camera box
735 mm camera box
II 2 G for gas EEx d IIC T (*) for gas
fl 120
3 x fl 10,5
120¡
fl 150
75
475
M8
225
0951 31 (L = 735)
Product features/customer benefits
- 4 types of box: covering all types of camera
Data sheet available on request
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising