- No category
advertisement
Uninterruptible
Power Supplies
EnPlus
6kVA / 8kVA / 10kVA / 12kVA / 15kVA / 20kVA
Tower and Rackmount Option
Ex ce llence as a
Standard
• True On-Line Double Conversion technology provides
full protection from all power problems with pure sine
wave output
• Protects mission critical applications from downtime,
data loss, data corruption,and process interruption by
providing continuous well reglated clean power
• Fully digitalized microprocessor controlled
• LCD display, LEDs display for easy viewing of real
time operational status and control parameters, power
usage, battery run time and etc
• Audible sound for fault alert condition
• Plug & Play installation
• User swappable batteries replacement
• Extended run time capability with external battery
modules
• Custom design for long hour back-up
• Advanced Battery Management systems
• Automatic battery diagnostics and health check
• Cold start function (DC power on)
• Emergency Power Off function
• Load segmentation for priority load assignment
• UPS Management Software included for
monitoring and auto shutdown
• SNMP/Relay card connectivity available as option
• Standard RS232 serial communication with
USB port as option
• Conform to IEC61000-4, FCC Part 15 and
CISPR 22 design standard
EnPlus
6kVA / 8kVA / 10kVA / 12kVA / 15kVA / 20kVA
Tower & Rackmount
TECHNICAL DATA
POWER RATING
Nominal Output Power (VA)
Nominal Output Power (W)
Systems Topology
INPUT
Phase
Bypass Voltage
Input Voltage Range
Frequency
Frequency Window from mains
Ex ce llence as a
Standard
6000 8000 10000 12000 15000 20000
4200 5600 7000 8400 10500
On-line, double conversion topology with automatic bypass
14000
Single phase three wires or three phases five wires (8-20KVA)
184-265 VAC (user selectable)
120/140/160/180 VAC-276 VAC (Single phase)
208/242/277/312 VAC-478 VAC (Three phase)
50/60 Hz. Auto selection
45-65 Hz
Synchronization Window
Input Current (Single phase input) 23A 30.7A
Input Current (Three phase input) N.A 10.2A
Input Power Factor
OUTPUT
Output Voltage
Voltage Regulator
+/- 3 Hz
38.3A 46A 57.5A 76.6A
12.8A 15.3A 19.2A 25.5A
> 0.98 (1ph,3W), > 0.95 (3ph, 5W)
208/220/230/240 VAC, selectable form LCD panel
+/- 2%
Voltage Distortion
Frequency Regulation
Dynamic Response
Overload Capacity
Efficiency
BATTERY AND CONNECTION
Connection Input
<3% for linear load, <5% for non-linear load
+/-0.25 Hz (battery or free funning mode)
+/-9% max for 20% to 100% or 100% to 20% load step
110-125% 1 min, 126-150% 10sec
> 88%
Connection Output
Battery Type
Hardwired
Hardwired
7.2Ah/12V 7.2Ah/12V 34W/12V 7.2Ah/12V 7.2Ah/12V 9Ah/12V
Number of Batteries 20 20X2
Backup Time/Full load (min) 7 4 5
Recharge Time (to 90%)
7
< 4 hours to 90%
Dimension (WxDxH) mm w/o Isolation tx 257x590x 570 257 x 690 x 715 342x690x878
Dimension (WxDxH) mm w/ Isolation tx 257x590x700 342 x 690 x 715 342x690x878
Dimension (WxDxH) mm RM 6U 428x597x260 428 x 658 x 260
4
342 x 863 x 905
342 x 863 x 905
Not Available
4
Weight (KG) w/o Isolation tx 86 112
Weight (KG) w/ Isolation tx
130
123 178 180 180
Weight (KG) - RM 3U Power Module 20 24
175
225
Not Available
Weight (KG) - RM 3U Battery Module 66 66 68
ENVIRONMENTAL
Ambient Temperature +0 C°to +40 C° , Recommended +15 C°to +25 C°
Storage temperature -15 C° to +50 C°
Cooling Force air cooling
Humidity <95%, non-condensing
Audible Noise (dBA) <55 dBA on normal and battery mode
STANDARDS
Safety UL 1778, CE (20000VA)
Emissions IEC61000-4, FCC Part 15, CISPR22
Not Available
Specifications subject to change without notice