Maintenance-free UPS does away with battery replacement New uninterruptible DC power supply with capacitor technology Uninterruptible power supplies usually store electrical energy in rechargeable lead-acid batteries. The temperatures inside a control cabinet, however, shorten the service life of the battery substantially, making battery replacement a routine necessity – for instance, once a year at a cabinet temperature of 40 °C. Not so in the case of the innovative DC UPS from SITOP. Capacitors with a long service life mean you don‘t have to replace batteries, which is how the totally maintenance-free UPS pays for itself within a short time. As no hydrogen is emitted even in the event of a fault, there is no need for ventilation of the site. The much shorter charging times also mean fast availability following a power failure. The 24 V DC UPS comes in degree of protection IP65 for distributed use, and in IP20 for DIN-rail mounting. This means it is possible to back up data after a power failure, and to safely shut down a PC-based control application, for example. SITOP UPS500 Answers for industry. The advantages at a glance Totally maintenance-free DC UPS with high-capacity double-layer capacitors • Modularly cascadable for DIN-rail mounting: SITOP UPS500S basic unit 24 V/15 A with integral 2.5 or 5 kW energy storage, combinable with up to 3 UPS501S expansion modules (5 kW) • SITOP UPS500P 24 V/7 A in degree of protection IP65 for distributed use, e.g. on support arms • Long-life capacitors eliminate battery replacement: After 8 years, the UPS500 still has 80% of its rated capacity at an ambient temperature of 50°C • Totally maintenance-free • No ventilation of the mounting location is necessary (VDE 0510 Part 2 / EN 50272-2) • Backup is available again quickly • Safe shutdown and correct restart of SIMATIC PCs • Software tool supports further processing and response of the PC: www.siemens.com/sitop-ups Technical data SITOP Order Nos. Input data Input voltage Ue rated / range Connection threshold for backup Input current Ie rated Mains buffering Range adjustable via DIP switches Response to return of input voltage after the set buffer time On/Off control current circuit (via external floating NO contacts) Output data Output voltage (backup and standard mode) Ua rated / range Output current Ia Load current Efficiency (rated operation) / power losses Protection and monitoring Polarity reversal protection Overload/short-circuit protection Standard mode Backup mode Alarm (not ready for backup) Capacitor charging (over 85% charged) Control signals On/Off control signal via floating NO contact ”Remote timer start“ via USB interface USB interface Specification 2.0 with Full Speed, i.e. 2 Mbit/s Connection to PC: General data Radio interference level (EN 55022) / immunity Protection class Degree of protection (EN 60529) Ambient temperature during operation / Transport and storage temperature Dimensions (W x H x D) in mm Weight Mounting Approvals Order No. Description Dimensions (W x H x D) in mm Weight UPS500S – basic units 15 A 2.5 kW: 6EP1 933-2EC41, 5 kWs: 6EP1 933-2EC51 UPS500P – basic unit 7 A, IP65 10 kWs: 6EP1933-2NC11 DC 24 V / 22 … 29 V DC 24 V / 22.5 … 29 V 22.5 V DC ± 0.1 V (factory setting), UPS500S adjustable in range 22 to 25.5 V DC (in 0.5 V steps) 15.2 A + approx. 2.3 A in charge mode 7A + approx. 2 A in charge mode 5, 15, 25, 35, 45, 55, etc. to 315 seconds (in 10 s steps) or – max. backup time Interruption of Ua for 5 s for automatic restart of PCs or optionally no interruption Backup mode is terminated by opening the control current circuit – 24 V DC +/– 3% 24 V DC +/– 3% 0 ... 15 A 1 A (factory setting) or 2 A, selectable 97.5 % / 9 W 0 to 7 A 2A 96.9% / 5.2 W Against reversed input voltage Yes, restart LED green (o.k.) and floating changeover switch LED yellow (Bat) and floating changeover switch LED red (Alarm) and floating changeover switch Second LED green (Bat > 85 %) and floating NO contact LED green (o.k.) LED yellow (Bat) LED red (Alarm) Second LED green (Bat > 85 %) Backup mode is terminated by opening the control current circuit -Starts mains buffering for the set backup time Starts mains buffering for the set backup time Output of all alarm signals and receipt of the signal ”Remote timer start“ Supply + 5V from DC UPS („self powered“) Supply + 5V from PC („bus powered“) Commercially available 4-core shielded cable, 90 ohms, max. 5 m, USB series „B“ connector to DC UPS Class B / immunity to EN 61000-6-2 Class B / immunity to EN 61000-6-2 Class III (ext. circuit and power supply unit: Class III (ext. circuit and power supply unit: SELV voltage to SELV voltage to EN 60950 necessary) EN 60950 necessary) IP20 IP65 0 to +60 °C (UPS500P: 0 ... +55°C) for natural convection climate class 3K3 to EN 60721 / –40 to +70 °C 120 x 125 x 125 (free space required 50 mm above and 50 mm below) Approx. 1.0 kg Snapped onto standard DIN rail EN 50022-35x15/7.5 CE, UL 508 / CSA C22.2, File E197259 470 (without connector) x 80 x 80 Approx. 2.2 kg Screw-mounted in all installation positions CE, UL508 planned, File E179336 SITOP UPS501S expansion module 5 kW 6EP1935-5PG01 Expansion module to extend the backup time, up to 3 units can be connected in parallel with a basic unit via connecting cable 70 × 125 × 125 Approx. 0.7 kg Connector set for SITOP UPS500P 6EP1975-2ES00 Connector for input and output, and preassembled USB cable in 2 m length --- Backup and charging times Configurations SITOP UPS500S/501S Basic module 2.5 kWs Expansion modules – Total energy 2.5 kWs Backup current Backup times 0.5 A 134 sec 0.8 A 90 sec 1A 75 sec 2A 38 sec 3A 26 sec 4A 19 sec 5A 15 sec 6A 12 sec 7A 10 sec 8A 8 sec 10 A 6 sec 12 A 4 sec 15 A 3 sec Charging current Charging times 2A 54 sec 1A 110 sec Siemens AG Industry Sector Systems Engineering P.O. Box 23 55 90713 FÜRTH GERMANY www.siemens.com/sitop 5 kWs – 5 kWs 2.5 kWs 1 × 5 kWs 7.5 kWs 5 kWs 1 × 5 kWs 10 kWs 2.5 kWs 2 × 5 kWs 12.5 kWs 5 kWs 2 × 5 kWs 15 kWs 2.5 kWs 3 × 5 kWs 17.5 kWs 5 kWs 3 × 5 kWs 20 kWs UPS500P 10 kWs – 10 kWs 236 sec 167 sec 138 sec 76 sec 52 sec 39 sec 31 sec 26 sec 21 sec 18 sec 15 sec 12 sec 9 sec 390 sec 266 sec 219 sec 122 sec 82 sec 61 sec 49 sec 40 sec 34 sec 29 sec 23 sec 19 sec 14 sec 478 sec 346 sec 296 sec 156 sec 106 sec 81 sec 65 sec 55 sec 47 sec 40 sec 32 sec 26 sec 20 sec 632 sec 440 sec 365 sec 203 sec 136 sec 101 sec 81 sec 67 sec 58 sec 50 sec 39 sec 32 sec 25 sec 748 sec 527 sec 414 sec 230 sec 159 sec 120 sec 95 sec 80 sec 69 sec 59 sec 47 sec 38 sec 30 sec 851 sec 580 sec 490 sec 265 sec 186 sec 139 sec 111 sec 94 sec 81 sec 69 sec 54 sec 44 sec 35 sec 1007 sec 706 sec 572 sec 306 sec 213 sec 160 sec 130 sec 106 sec 82 sec 79 sec 62 sec 52 sec 40 sec 647 sec 435 sec 351 sec 152 sec 108 sec 84 sec 68 sec 57 sec 49 sec – – – – 120 sec 205 sec 158 sec 311 sec 223 sec 425 sec 263 sec 503 sec 318 sec 625 sec 355 sec 695 sec 417 sec 816 sec 360 sec – Subject to change without prior notice Order No.: E80001-A2540-P310-X-7600 21/17769 GI.SE.ST.SITP.52.9.02 SB 11082. Printed in Germany © Siemens AG 2008 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement