Victron Energy Blue Smart IP22 Charger Datasheet
Advertisement
Advertisement
Blue Smart IP22 Charger
180-265 VAC
Blue Smart IP22
12/30 (3) www.victronenergy.com
Bluetooth Smart enabled
The Blue Smart IP22 Charger is the wireless solution to monitor voltage and current, to change settings and to update the charger when new features become available.
High efficiency
With up to 94% efficiency, these chargers generate up to four times less heat when compared to the industry standard.
And once the battery is fully charged, power consumption reduces to 0,5 Watt, some five to ten times better than the industry standard.
Adaptive 6-stage charge algorithm: test - bulk – absorption - recondition – float – storage
The Blue Smart Charger features a microprocessor controlled ‘adaptive’ battery management. The adaptive feature will automatically optimize the charging process relative to the way the battery is being used.
Storage Mode: less maintenance and aging when the battery is not in use
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V/cell (13,2V for a 12V battery) to minimize gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘equalize’ the battery. This feature prevents stratification of the electrolyte and sulfation, a major cause of early battery failure.
Also charges Li-ion (LiFePO₄) batteries
LiFePO₄ batteries are charged with a simple bulk – absorption – float algorithm.
NIGHT and LOW setting
When in NIGHT or LOW mode, the output current is reduced to max. 25% of the nominal output and the charger will be totally noiseless. The NIGHT mode automatically ends after 8 hours. The LOW mode can be ended manually.
Protected against overheating
Output current will reduce as temperature increases up to 50°C, but the Blue Smart Charger will not fail.
Eleven LEDs for status indication
Charge algorithm: TEST / BULK / ABSORPTION / RECONDITION / FLOAT / STORAGE / READY.
MODE button to set: NORMAL (14,4V) / HIGH (14,7V) / RECONDITION / LI-ION.
Blue Smart Charger
Input voltage range
Charge current, normal mode
Charge current, NIGHT or LOW
Efficiency
No load power consumption
Frequency
Number of outputs
Charge voltage 'absorption'
Charge voltage 'float'
Charge voltage 'storage'
Charge algorithm
Can be used as power supply
Protection
Operating temp. range
Humidity (non-condensing)
Material & Colour
Battery connection
230 V AC connection
Protection category
Weight
Dimensions (h x w x d)
Safety
Emission
Immunity
Automotive
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: [email protected] | www.victronenergy.com
12V, 1 output
15 / 20 / 30A
12V, 3 outputs
15 / 20 / 30A
180 – 265 VAC
15 / 20 / 30 A
7,5 / 10 / 15 A
93%
24V, 1 output
8 / 12 / 16A
24V, 3 outputs
8 / 12 / 16A
180 – 265 VAC
8/12/16 A
4 / 6 / 8 A
94%
0.5 W
45 – 65 Hz
1 3
Normal: 14,4V High: 14,6V Li-ion: 14,2V
0.5 W
45 – 65 Hz
1 3
Normal: 28,8V High: 29,2V Li-ion: 28,4V
Normal: 13,8V High: 13,8V Li-ion: 13,35V
Normal: 13,2V High: 13,8V Li-ion: n. a.
Normal: 27,6V High: 27,6V Li-ion: 26,7V
Normal: 26,4V High: 26,4V Li-ion: n. a.
6-stage adaptive
Yes
Battery reverse polarity (fuse) Output short circuit Over temperature
-20 to +50°C
Max 98%
ENCLOSURE
Aluminium (blue RAL 5012)
Screw terminals 13 mm² / AWG6
Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ)
IP22
1,3 kg
235 x 108 x 65 mm
STANDARDS
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-6-3, EN 61000-3-2
E4-10R
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
E4-10R