Anver Vacuum Pumps
Section
Vacuum
Pumps and
Stations
Vacuum Pumps & Stations
Air-Powered Mini-Vacuum Stations
132 00 158 • Revision H
Control Number: 111504
ANVER AL101, AL1001/20 and AL1001/25 Series of Mini-Vacuum Stations
ANVER Air-Powered Mini-Vacuum Stations are low cost, compact, require little maintenance and feature quality
ANVER venturi vacuum generators. A vacuum check valve maintains vacuum in case of power failure. On clean,
smooth, non-porous material, the unit will hold vacuum per ASME Standard B30.20a-2001 for Vacuum Lifting
Devices allowing the operator to put down the load safely. A vacuum release/blow-off valve ensures a quick and
consistent attach and release for high production usage. Air supply must be clean, dry and regulated.
AL101 Features:
Stainless Steel
Enclosure and Plated
Components
5.00
(127)
1.56
(40)
4.44
(113)
1
10
AL
1.50
(38) 1.31
(33)
2.50
(64)
0.56 (14)
3.50
(89)
1/4" NPT
VACUUM PORT
1/4" NPT
COMPRESSED
AIR PORT
AL1001 Features:
• Include a pressure gauge for
monitoring incoming compressed air
• These Mini-Vacuum Stations also
perform well on slightly porous material
• An internal air filter with replaceable
element on vacuum port protects
against contamination
11.00
(279)
2.00
(51)
(3) 8-32 UNF
TAPPED HOLES
Bottom View
Mounting Bolt Pattern
AL
10
01
1/4" NPT
COMPRESSED
AIR PORT WITH
SLIDE VALVE
5.50
(140)
3/8" NPT
VACUUM
PORT
8.50
(216)
3.56
(90)
9.50
(241)
(4) 1/4-20 UNC
TAPPED HOLES
Bottom View
Mounting Bolt Pattern
Specifications:
ANVER
Item
No.
Vacuum
Generator
Model
Number
Vacuum
Flow
SCFM
(l/min.)
Air
Consumption
SCFM
(l/min.)
Optimum
Supply
Pressure
(PSI)
Maximum
Vacuum
in. Hg
(mm Hg)
Weight
lbs.
(kg)
AL101
VR09
0.74
(21)
1.27
(36)
72.5
27
(686)
7
(3)
AL1001/20
JE20H
4.30
(122)
7.00
(198)
72.5
27
(686)
16
(7)
AL1001/25
JE25H
7.00
(198)
9.50
(269)
72.5
27
(686)
16
(7)
36 Parmenter Road • Hudson MA 01749 USA • 978-568-0221 • 800-654-3500 • FAX 978-568-1570 • www.anver.com • E-Mail: sales@anver.com
Vacuum Pumps & Stations
Electric Powered Mini-Vacuum Stations
ANVER EP1001 Series of Mini-Vacuum Stations
These low cost, compact electric-powered vacuum stations require little maintenance. A vacuum check valve is provided to
maintain vacuum in case of power failure. On clean, smooth, non-porous material, the unit will hold vacuum per ASME
Standard B30.20a-2001 for Vacuum Lifting Devices allowing the operator to put down the load safely. A vacuum
attach/release valve is included to ensure a consistent attach/release.
Features a quality ANVER electric vacuum pump and a vacuum gauge to monitor vacuum level. Continuously running vacuum pump makes this vacuum station perform well on slightly porous material. An internal vacuum filter with replaceable element protects against contamination.
EP
115 VAC
TWIST-LOC
POWER CORD
4 FT. LONG
10
11.00
01
PO
WER
5.50
ON
VA
CU
OFF UM
8.50
1/4" NPT
VACUUM PORT
3.56
9.50
(4) 1/4-20 UNC
TAPPED HOLES
Specifications:
Model
Number
Vacuum
Pump No.
Supply
Voltage
Vacuum Flow
SCFM
(l/min.)
Max. Vacuum *
in. Hg
(mm Hg)
Weight
lbs.
(kg)
EP1001
PMP-085-115
115-60-1
0.85
(24.12)
44
(610)
16
(7)
Air Powered Vacuum Pumps and Stations
Mitey-AirVac Air Powered Vacuum Stations
MTY-1 Air Powered Vacuum Station
Features:
• Low cost, light weight, subcompact size, requires little
or no maintenance.
• Internal vacuum check valve maintains vacuum in case of
power loss. On clean, smooth, non-porous material, the unit
will hold vacuum per ASME Standard B30.20a-2001 for
vacuum lifting devices, allowing the operator to put down the
load safely.
• Available in a panel face mounted push-button switch for
release/blow-off (shown at left) or with a remote switch
which activates a blow-off for quick release.
• Vacuum gauge for monitoring manifold vacuum level.
• Low compressed air consumption. No moving parts to create
heat of any type.
• Symmetrical mounting hole locations for multiple
mounting orientations.
MTY-2 Air Powered Vacuum Station
Features:
• Higher flow version of the MTY-1.
• Available in four flow rates and generating capacities.
• Higher flow for faster evacuation.
• Good for use on non-porous to slightly porous materials.
(4) M5
TAPPED
HOLES
3.31
(84)
4.11
(104)
3.31
(84)
3.66
(93)
(4) M5
TAPPED
HOLES
1.55
(39)
1/4" NPTF
COMPRESSED
AIR PORT
2.50
(64)
0.50
(13)
(4) M5
TAPPED
HOLES
1/4" PUSH-CONNECT
TUBE FITTINGS FOR
REMOTE RELEASE/BLOW-OFF
1/4" NPTF
VACUUM PORT
1/4" NPTF
COMPRESSED
AIR PORT
5.25
(133)
*
(4) M5
TAPPED
HOLES
2.50
(64)
MTY-1
4.11
(104) 1.55
(39)
1.28
(33)
1/4" PUSH
CONNECT
TUBING FITTING
VACUUM PORT
1.28
(33)
6.41
(163)
0.50 (13)
0.88 (22)
1.55
(39)
MTY-2
0.50
(13)
1/4" PUSH-CONNECT
TUBE FITTINGS FOR
REMOTE RELEASE/BLOW-OFF
*
5.25
(133)
0.50 (13)
0.88 (22)
1.55
(39)
Air Powered Vacuum Pumps and Stations
Mitey-AirVac Air Powered Vacuum Stations
Station
Number
Generator
Number
Compressed Air
Consumption
SCFM
(l/min.)
Vacuum Flow
SCFM
(l/min.)
Supply
Pressure
PSI
Rated
Vacuum
in. Hg
(mm Hg)
Unit Weight
Lbs.
(Kg)
MTY-1-09
VR09
1.27
(36)
0.74
(21)
72
26
(660)
2
(0.9)
MTY-1-09-FB
VR09
1.27
(36)
0.74
(21)
72
26
(660)
2
(0.9)
MTY-2-12
JE12H
2.37
(67)
1.59
(45)
72
26
(660)
3
(1.4)
MTY-2-12-FB
JE12H
2.37
(67)
1.59
(45)
72
26
(660)
3
(1.4)
MTY-2-15
JE15H
3.53
(100)
2.47
(70)
72
26
(660)
3
(1.4)
MTY-2-15-FB
JE15H
3.53
(100)
2.47
(70)
72
26
(660)
3
(1.4)
MTY-2-20
JE20H
6.36
(180)
4.41
(125)
72
26
(660)
3
(1.4)
MTY-2-20-FB
JE20H
6.36
(180)
4.41
(125)
72
26
(660)
3
(1.4)
MTY-2-25
JE25H
9.53
(270)
7.06
(200)
72
26
(660)
3
(1.4)
MTY-2-25-FB
JE25H
9.53
(270)
7.06
(200)
72
26
(660)
3
(1.4)
Optional Remote Mounted Switch and Tubing
MTY-SW
Optional Remote Mounted Switch Mounted - Mounts in a 5/8" Hole.
PC-T14
Remember to purchase PC-T14 Tubing - Sold Separately - (Keep in mind that you need to
specify a length of tubing long enough for both incoming and outgoing control)
8060301
Vac-Pack Vacuum Generator
Air Powered
132 00 367
Control Number 022704C
MANIFOLD
VACUUM GAUGE
FILTER
VIEW PORT
VP
1/4" NPTF
INPUT AIR
SUPPLY
PORT
F-5
VPF-57 AIR Series
7 VAIR
ANVER’s latest models of vacuum generators
feature high capacity pumps, valves, filters and
gauges for trouble-free operation in the most
demanding production environments. Designed
for use with a wide assortment of vacuum lifter
assemblies and interchangeable pad attachments.
These high quality Vac-Packs are ruggedly built,
yet affordably priced for unmatched value. The
VPF-57 AIR Series features a sturdy welded
frame construction for heavy weight load
lifting capability.
ac Se
-P rie
ac s
k
22.25"
(565 mm)
17.94"
(456 mm)
17.38"
(441 mm)
ATTACH / RELEASE
SLIDE VALVE
(2) 3/8" NPTF
VACUUM PORTS
PRESSURE GAUGE
Features:
Maintenance:
■ Air Powered Vacuum Generator
No electric power required, operates using dry, clean
compressed air for vacuum generation. The vacuum
generator is a single stage unit with no moving
parts or rubber gaskets to maintain or replace.
■ Air Filter
Oversized air filter provided inside the front cover features a
screw-on clear filter bowl for easy filter cleaning.
General:
■ Standard Frame Construction
The VPF-57 AIR Series has a fully welded frame
with a vacuum reservoir and load lifting capacity rating of
2,200 lb. (998 kg) for 3” sq. beams.
■ Front Mounted Gauges
Includes both an input air pressure and vacuum
indicator gauges, front mounted for continuous
monitoring by the operator. Also included is a
filter view port to monitor filter for cleaning.
■ (Optional) Heavy Duty Frame Construction Available
Load lifting capacity rating of 4,100 lb. (1,860 kg) for 3” x 6”
beams. Consult factory for application requirements.
■ Ergonomic Front Handlebar
Easy to grasp, large loop handlebar allows the
operator to easily and safely maneuver the
attached load without pushing on the load itself.
■ Versatility
For larger load lifting capability or alternate power
requirements, ANVER offers electric powered and
self-powered mechanical vacuum generators, all with standard mounting designs for interchangeability.
■ Slide Control Valve
The slide valve permits rapid vacuum attach
and release and is mounted to the handlebar
for convenient access by the operator.
Options:
■ Vacuum Check Valve and Reservoir
A check valve and a vacuum reservoir help to
maintain vacuum if the supply of compressed air is
interrupted, for safe handling of non-porous loads.
■ Takes Standard Dry, Clean Shop Air
Input Pressure to be regulated to 75 psi. Provided with 1/4”
NPT input air supply connector and shut-off slide valve.
Specifications:
Vac-Pack
Model No.
VPF-57/20-AIR
(Standard)
VPF-57/25-AIR
VPF-57/30-AIR
VPF-57/20HD-AIR
VPF-57/25HD-AIR
VPF-57/30HD-AIR
Vacuum
Flow
(scfm)
4.3
■ Optional Vacuum Leakage Sensing System (VLS-07)
The VLS-07 Series are battery powered units
consisting of solid state circuitry with microcontroller,
pressure sensor, LCD digital display of inches of Hg, warning
audible horn and red light. System is plumbed
to the Vac-Pack and monitors vacuum level triggering
the alarm in the event of unsafe vacuum level.
■ Optional Water Trap (WT-PF)
For wet applications: prevents saturation of filter
and possible damage to vacuum generator.
Air
Req. Input
Unit
Consumption Pressure Weight
(scfm)
(psi)
lb. (Kg)
6.5
Vacuum
Level
(Sea Level)
24” Hg
7.0
9.2
4.3
9.5
14.0
6.5
75
60 (27.2)
Consult
Factory
24” Hg
7.0
9.2
9.5
14.0
75
60 (27.2)
Consult
Factory
Application
Most smooth,
non-porous materials
Rough or semi-porous
materials, wood, stone etc.
Most smooth,
non-porous materials
Rough or semi-porous
materials, wood, stone etc.
Beam
Size
3” Sq.
3” x 6”
36 Parmenter Road • Hudson MA 01749 USA • 978-568-0221 • 800-654-3500 • FAX 978-568-1570 • www.anver.com • E-Mail: sales@anver.com
Vacuum Pumps and Vacuum Generators
Compressed Air Powered Vacuum Stations
AP Series Vacuum Stations
With Unique All Pneumatic Energy Saver Circuitry that Shuts Off the
Compressed Air Supply Line When Vacuum Is Achieved for More Economical
Operation
Features:
• All Pneumatic Energy Saver Circuitry automatically shuts off the
compressed air consumption when the proper vacuum level is achieved
• A Complete Vacuum Station with whisper-quiet air pump, vacuum
reservoir, muffler and controls
• Dry, oil-free air pump avoids contamination
• Generates Vacuum Levels of up to 27 in. Hg
AP Series Vacuum Station Controls include:
• Ball valve for Vacuum Attach-Release
• Adjustable vacuum switch to control vacuum level
• Vacuum gauges, vacuum reservoir and manifolds
• Air Regulator with gauge and check valve
• Vacuum Line Filter
• 10, 20, and 30 gallon reservoirs are standard. For
custom sizes, please consult factory.
ANVER
Item No.
Reservoir Size
Gallons
(liters)
Output
Pipe
Venturi
Type
Flow
scfm
(L/min)
Consumption
scfm
(L/min)
Length
in
(mm)
Dia.
in
(mm)
Height
in
(mm)
Weight
lb
(kg)
AP-10G30
10
(38)
1/2” NPT
JB30
9.25
(394)
13.9
(590)
36
(914)
10
(254)
17.5
(445)
50
(23)
AP-20G30
20
(76)
1/2” NPT
JB30
9.25
(394)
13.9
(590)
38
(965)
14
(356)
24
(610)
76
(34)
AP-30G30
30
(114)
3/4” NPT
JB30
9.25
(394)
13.9
(590)
43
(1092)
16
(406)
25
(635)
113
(51)
*scfm flow and consumption shown at optimum operating pressure of 5bar = 72.5 psi.
1130501
Vac-Pack Vacuum Generator
Electric Powered
MANIFOLD
VACUUM GAUGE
POWER CORD
VPF-57-AC Series
FILTER
VIEW PORT
-A
C
22.25"
(565 mm)
17.94"
(456 mm)
17.38"
(441 mm)
ATTACH / RELEASE
SLIDE VALVE
(2) 3/8" NPTF
VACUUM PORTS
POWER SWITCH
ANVER’s latest models of vacuum generators
feature high capacity pumps, valves, filters and
gauges for trouble-free operation in the most
demanding production environments. Designed for
use with a wide assortment of vacuum lifter
assemblies and interchangeable pad attachments.
These high quality Vac-Packs are ruggedly built,
yet affordably priced for unmatched value. The
VPF-57-AC features a sturdy welded frame construction for heavy weight load lifting capability.
Features:
General:
■ Front Mounted Controls and Gauges
Vacuum gauge is mounted on front cover for continuous
monitoring by operator. The power switch includes built-in
circuit breaker. Also included is a filter view port to monitor
filter for cleaning.
■ Vacuum Pump Description
High-performance oil-less dry piston pump has a ½ hp motor
capable of generating 4.3 cfm. Motor is thermally protected
and is rated for 100% duty cycle.
■ Ergonomic Front Handlebar
Easy to grasp, large loop handlebar allows the operator
to easily and safely maneuver the attached load without
pushing on the load itself.
■ Slide Control Valve
The slide valve allows rapid vacuum attach and release and
is mounted to the handlebar for convenient access by the
operator.
■ Vacuum Check Valve and Reservoir
A check valve with vacuum reservoir helps to maintain
vacuum if electrical power is interrupted, for safe handling
of non-porous loads.
■ Twistlock Power Cord Plug and Receptical
Both Twistlock plug and receptical are provided to prevent
accidental power cord separation.
Maintenance:
■ Oil-Less Dry Piston Vacuum Pump Motor
Powerful ½ horsepower motor drives a high-performance 4.3
CFM dry piston vacuum pump.
■ Air Filter
Oversized air filter provided inside the front cover features a
screw-on clear filter bowl for easy filter cleaning.
■ Standard Frame Construction
The VPF-57-AC Series has a fully welded frame
with a vacuum reservoir and load lifting capacity rating of
2,200 lb. (998 kg) for 3” sq. beams.
■ (Optional) Heavy Duty Frame Construction Available
Load lifting capacity rating of 4,100 lb. (1,860 kg) for 3” x 6”
beams. Consult factory for application requirements.
■ Versatility
For larger load lifting capability or alternate power
requirements, ANVER also offers other electric, air
powered, and self-powered mechanical vacuum
generators. All units are provided with modular
standard mounting designs for interchangeability.
Options:
■ Optional Vacuum Leakage Sensing System (VLS-07)
The VLS-07 Series are battery powered units consisting
of solid state circuitry with microcontroller, pressure sensor,
LCD digital display of inches of Hg, warning audible horn and
red light. System is plumbed to the Vac-Pack and monitors
vacuum level triggering the alarm in the event of unsafe
vacuum level.
■ Optional Water Trap (WT-PF)
For wet applications: prevents saturation of filter and possible
damage to pump.
Specifications:
Vac-Pack
Model No.
Pump Cap.
(scfm)
Vacuum
Pump
hp
Vacuum
Level
(Sea Level)
Unit
Weight
lb. (kg)
Incoming Power
Requirement
AC
Beam
Size
VPF-57-AC
4.3
½
24” Hg
68
115V/60Hz/1ph/6amps
3” Sq.
VPF-57-AC240
4.3
½
24” Hg
68
(30.8)
220-240V/50Hz/1ph/3amps
3” Sq.
VPF-57HD-AC
4.3
½
24” Hg
68
(30.8)
115V/60Hz/1ph/6amps
3” x 6”
VPF-57HD-AC240
4.3
½
24” Hg
68
(30.8)
220-240V/50Hz/1ph/3amps
3” x 6”
(30.8)
Vac-Pack Vacuum Generator
Electric Powered
132 00 279
VPE1-FD (Series) shown
W
WIDTH
L
LENGTH
ATTACH/RELEASE
CONTROL PENDANT
25.0"
(635 mm)
H
HEADROOM
18.5"
(470 mm)
3/8" NPT VACUUM PORTS (2)
WITH BALL VALVE SHUT-OFF
VPE1
Series
with ANVER VacGuard II™
Control No.: 061405K
Page 1 of 2
Vacuum Control System
ANVER’s VPE1 Series Vac-Packs feature dual
vacuum ports, over-sized filters and increased
air flow, making them particularly suitable for
handling non-porous to semi-porous loads.
Designed for use with a wide assortment of
vacuum pad attachments and lifter assemblies,
these high quality Vac-Packs are ruggedly
designed for heavy production use. Units are
available with heavy duty frames, for mounting
remotely, on pillars, or on overhead trolleys.
Features:
Maintenance:
• VacGuard II Vacuum Control System
This revolutionary solid-state Vacuum Control System combines
all the required vacuum generator controls in a rugged, compact
polycarbonate enclosure. The VacGuard II controls all vacuum
pump functions, safety lights and can be fitted with an optional
audible vacuum leakage warning system.
• Bottom Hinged Front Cover & Rear Hinged Top-Back Panel
The front cover folds open for easy access to all components.
• Front Control Panel and Gauges
All gauges, lights and power switches are mounted on the front
of the control panel. The two vacuum gauges on the face of the
panel display the level of vacuum in the manifold and in the
reservoir. The control pendant clip mounts to the front handle
on a 10 ft. coiled cord and provides rapid attach and release
functions at the operator’s fingertips.
Vacuum Pump*:
• Air Filter
Oversized air filter provided inside of front cover features a
screw-on clear filter bowl for easy filter cleaning.
• Two oil-less pumps are available. Each are thermally overload protected and requires 115V/60HZ-1ph 15 amp service.
Standard Pump (D):
Dry piston pump with ½ hp motor shuts off above preset vacuum
levels, restarts automatically and generates up to 4.3 cfm.
Optional Feature (R):
Continuous running pump in the attach mode for use on semiporous loads.
• Indicator Lights
Green light indicates, “safe” vacuum level.
Red light indicates, “unsafe” vacuum level.
• Vacuum Retention
The system includes an internal check valve to halt loss of supply
side vacuum in the event of a power failure. A vacuum reservoir
assists in maintaining a safe vacuum level during a power failure.
• Thermal Overload Protection
Heat damage is prevented by a thermal sensor that shuts off
the motor if the motor temperature exceeds safe limits.
• Ergonomic Control Handlebar
Easy to grasp, large loop handlebar keeps operator safely away
from load, holds the control pendant, and positions the operator
for easy viewing of all gauges, lights and instructions. Handlebar
is removable.
* Note: ANVER VacGuard II Control System not available with
vacuum generators used as overhead trolley configuration
or pillar mounted configuration.
Specifications:
• The Standard Duty Frame is nominally rated for 2200 lb
(997.9 kg) and is designed for mounting on a 3” x 3” beam.
Unit weighs approximately 95 lb (43 kg).
• The Heavy-Duty Frames are nominally rated for 4600 lb
(2078 kg), designed for a 3” x 6” or 5” x 7” beam.
Unit weighs approximately 115 lb (52 kg).
Options:
• Twist-Lock Power Cord Connectors
The Twist-lock receptacles, both the male and female are supplied, prevent accidental disconnection from the power source.
• Optional Water Traps (WT-VP1-[Series])
For wet applications: prevents saturation of filters
and possible damage to pumps.
• Audible Vacuum Leakage Warning System (VLS-03E)
Integrated electronically controlled vacuum leakage sensor
monitors vacuum level and triggers a visual and audible
alarm in the event of an unsafe vacuum level.
Overall Dimensions:
Lifting Frame
*
(F) Standard
(H) Heavy Duty
(X) Heavy Duty
(R) Remote
W = Width
In. (mm)
14.6 (371)
18.9 (479)
18.9 (479)
14.6 (371)
L = Length
In. (mm)
12.4 (315)
12.4 (315)
12.4 (315)
12.4 (315)
H = Height
In.
(mm)
19.63 (499)
21.56 (548)
21.94 (557)
14.81 (376)
* Note: Front handlebar not supplied with (R) Remote Generator.
ANVER Corp. • 36 Parmenter Road • Hudson MA 01749 USA • 978-568-0221 • 800-654-3500 • FAX 978-568-1570 • E-Mail: sales@anver.com • www.anver.com
Vac-Pack Vacuum Generator
Electric Powered
VPE1-XDR
Electric Vacuum Station
R
VPE1-FD (Series) shown
With ANVER VacGuard II™
Vacuum Control System
(#VS35000018)
Optional Feature
Continuous running pump in
the attach mode for use on
semi-porous loads.
Truncate ‘R’ if feature is not
needed.
This integrated solid state
vacuum control is standard
with all VPE1 Series Vac-Packs
D
VLS-03E is standard on VPE1
Series.
Dry Piston Pump (Standard)
Dry Piston Pump with ½ hp
motor shuts off and restarts at
preset vacuum levels, generating up to 4.3 cfm. Power
supply required: 115V-60Hz-1ph
15 amp circuit.
F
Standard Frame
For lifters having beam
size 3” x 3” (76 mm sq.)
and lifting capacity* up to 2200 lb (997.9 kg).
T
H
Tilter Mount
Same as remote mount, but pendant has an extra
switch to control an electric tilt actuator. Mounted
with (4) 5/16-18 UNC tapped holes.
* Note: ANVER VacGuard II Control System not
available with vacuum generators used as
overhead trolley configuration or pillar
mounted configuration.
Heavy Duty Frame
For lifters having beam size 3” X 6” (76 x 152 mm)
lifting capacity up to 4600 lb (2078 kg).
O
X
*Overhead Trolley (Model VP1-OD)
Heavy Duty Frame
Pendant not available, vacuum on/off must be
controlled by an external valve.
For lifters having beam size 5” x 7” (127 x 178 mm)
and lifting capacity up to 4600 lb (2078 kg).
*Pillar Mounted (Model VP1-PD)
R
Remote Mount
This unit has no bail, and
will mount on a flat surface
with (4) 5/16-18 UNC
tapped holes.
P
Note: Capacities shown are approximations, actual capacity is dependent upon the lifting application.
Pendant not available, vacuum
on/off must be controlled by an
external valve. Mounted with (4)
5/16-18 UNC tapped holes.
Vac-Pack Vacuum Generator
Electric Powered
132 00 280
LIFT BALE
4" X 5" (100 X 125)
HOOK OPENING
W
L
Revision: B
January 3, 2002
Page 1 of 2
VPE3
Series
with ANVER VacGuard™
Vacuum Control System
30.7
779)
H
23.6
(600)
3/4" NPTF VACUUM PORTS (2)
WITH BALL VALVE SHUT-OFF
Safety Features
 VacGuard Vacuum Control System
This revolutionary solid-state Vacuum Control System combines all
the required vacuum generator controls in a rugged, compact ABS
enclosure. The VacGuard controls all vacuum pump functions,
safety lights and includes an audible vacuum leakage warning system.
 Audible Vacuum Leakage Warning System
Integrated electronically controlled vacuum leakage sensor monitors vacuum level and triggers a visual and audible alarm in the
event of an unsafe vacuum level.
 Indicator Lights
Green light indicates, “safe” vacuum level.
Red light indicates, “unsafe” vacuum level.
 Vacuum Retention
The system includes an internal check valve to halt loss of supply
side vacuum in the event of a power failure. A 3.5 gallon, 822 cu.
in. (13 liter) vacuum reservoir assists in maintaining a safe vacuum level during a power failure.
 Front Control Panel and Gauges
All gauges, lights and power switches are mounted on the front of
the control panel. The two vacuum gauges on the face of the
panel display the level of vacuum in the manifold and in the reservoir. The control pendant clip mounts to the front handle on a 12
ft. coiled cord and provides rapid attach and release functions at
the operator’s fingertips.
 Thermal Overload Protection
Heat damage is prevented by a thermal sensor that shuts off the
motor if the motor temperature exceeds safe limits.
 Twist-Lock Power Cord Connectors
The Twist-lock receptacles, both the male and female are supplied, prevent accidental disconnection from the power source.
ANVER’s VPE3 Series Vac-Packs are exceptionally versatile. They have many built-in safety features, and can be configured for remote
operation.
Options
 Heavy-Duty Frame
 Optional Water Traps for Wet
Applications: Prevents Saturation of Filters
and Possible Damage to Pumps
 Remote Configuration
Maintenance
 Gull-Wing Covers, Front and Rear
Enclosure folds open to allow easy access to
all components.
 Clear Filter Cover, 2 Places
Located on the front and at the rear of the unit, the filter covers are
clear for quick inspection and screw off for easy cleaning.
Vacuum Pump
 Pump has a 3/4 Hp oil-less motor and requires
115V-60Hz-1 phase 13 amp power supply.
Pump shuts off above preset vacuum levels, restarts automatically,
and generates up to 10 cfm.
Specifications
 Standard Frame is rated up to 6900 lb (3130 kg), for
3” x 6” beam. Unit weight is approximately 185 lb (84 kg).
 Heavy-Duty Frame is rated for 8000 lb (3629 kg), for
5” x 7” beam. Unit weight is approximately 195 lb (88 kg).
 Remote mount frame (No Lift Bail). Unit weight is
approximately 165 lb (75 kg).
Overall Dimensions:
Lifting Frame
(S) Standard
(H) Heavy Duty
(L) Light Duty
W = Width
In.
(mm)
24.4 (619)
24.4 (619)
20.4 (518)
L = Length
In.
(mm)
12.4 (315)
12.4 (315)
12.4 (315)
H = Headroom
In.
(mm)
28.6 (726)
29.1 (739)
26.8 (681)
I/Prdcsht/VPS#(13200280)
36 Parmenter Road • Hudson MA 01749 USA • 978-568-0221 • 800-654-3500 • FAX 978-568-1570 • www.anver.com E-Mail: sales@anver.com
Vac-Pack Vacuum Generator
Electric Powered
VPE3-X
Electric
Vacuum Generator
VPE3-S shown
With ANVER VacGuard™
Vacuum Control System (VS31000010)
L
This integrated solid state vacuum control with
leakage sensor warning system is standard on all
VPE3 Series Vac-Packs.
Light Duty Frame
For use with lifters typically using the VPE1
series mounting, but with the benefit of larger
pump, indicating lights and vacuum reservoir.
3” (76 mm) square beam and lifting capacity
up to 2200 lbs (1000 Kg).
S
H
Standard Duty Frame
For lifters having a beam size of 3” x 6”
(76 X 152 mm) rectangular tubing and lifting
capacity up to 6,900 lb (3130 kg).
Heavy Duty Frame
For lifters having beam size of 5” x 7” (127
X 178 mm) and lifting capacity up to 8,000
lb (3629 kg) or more. Check with factory.
R
T
Remote Mount
This unit has no bale and will mount on a flat
surface using four (4) 5/16-18 UNC tapped
holes.
Remote Mount For Tilter
Same as the Remote Mount, but pendant
has an extra switch to control an electric tilt
actuator or hydraulic cylinder.
Vac-Pack Vacuum Generator
Battery Powered
132 00 388
Control Number: 081104H
VPF-57-DC shown
BATTERY CONDITION
INDICATOR
MANIFOLD
VACUUM GAUGE
12V DC POWER/CHARGER
POWER LIGHTS
FILTER
VIEW PORT
CHARGER
POWER CORD
VPF-57-DC Series
ANVER’s VPF-57-DC Series Vac-Pack Vacuum
Generator contains the same features as the
standard VPF-57-AC Series but includes a heavy
duty rechargeable 12 volt DC battery, making it
suitable for handling non-porous loads. It is
commonly used for special applications where
AC power is not readily available.
22.25"
(565mm)
17.94"
(456mm)
17.38"
(441mm)
(2) 3/8" NPTF
VACUUM PORTS
DC POWER SWITCH
ATTACH RELEASE
SLIDE VALVE
Features:
Maintenance:
■ Front Mounted Controls and Gauges
Vacuum gauge is mounted on front cover for continuous
monitoring by operator. Also included is a filter view port to
monitor filter for cleaning.
■ Indicator Lights
• Amber light indicates “power on” for Vac-Pack Vacuum
Generator.
• Red light indicates “charger-on” for battery charger.
■ Ergonomic Front Handlebar
Easy to grasp, large loop handlebar allows the operator
to easily and safely maneuver the attached load without
pushing on the load itself.
■ Attach and Release Controls
VPF-57-DC (Standard): Slide valve allows rapid vacuum
attach and release.
VPF-57-DCP (Optional): Attach and release push-button
located on control pendant with 8ft long coiled cord.
Both styles are mounted to the handlebar for convenient
access by the operator.
■ Vacuum Check Valve and Reservoir
A check valve with vacuum reservoir helps to maintain
vacuum if electrical power is interrupted, for safe handling
of non-porous loads.
■ Automatic Vacuum Control for Vacuum Pump
■ Oil-Less Diaphragm Vacuum Pump Motor
Powerful 1/5 horsepower motor drives a 1.12 CFM
diaphragm vacuum pump.
■ Air Filter
Oversized air filter provided inside the front cover features a
screw-on clear filter bowl for easy filter cleaning.
When Vac-Pack reaches preset vacuum level, the vacuum pump
will automatically stop running. During the lift cycle, if the VacPack resevoir loses some of its vacuum, the vacuum pump will
automatically restart and run until original preset vacuum level is
attained. This control will reduce battery draw to acheive full-shift
operation.
■ Battery Charger (GC-CHARGE-15)
Integrated 1.5 amp battery charger is an advanced battery
charger designed specifically for today’s high performance deepcycle AGM batteries. It provides microprocessor controlled threestep charging. A male receptacle is supplied to plug into a standard outlet. The charger is interlocked to prevent Vac-Pack from
being used during charging. A “charger on” indicator light located
on front cover of Vac-Pack will illuminate when battery is being
charged.
General:
■ Vacuum Pump Description
High-performance oil-less diaphragm pump has a 1/5 hp
motor capable of generating 1.12 cfm. Motor is rated for
100% duty cycle.
■ Standard Frame Construction
The VPF-57-DC Series has a fully welded frame with a
vacuum reservoir and load lifting capacity rating of 2,200 lb.
(998 kg) for 3” sq. beams.
■ Battery Specifications
• 12 amp hour, sealed battery can provide full 8 hour shift
operation in many applications.
■ Versatility
For larger load lifting capability or alternate power
requirements, ANVER also offers other electric, air powered,
and self-powered mechanical vacuum generators. All units
are provided with modular standard mounting designs for
easy interchangeability.
Options:
■ Optional Vacuum Leakage Sensing System (VLS-07)
The VLS-07 Series are battery powered units consisting of
solid state circuitry with microcontroller, pressure sensor,
LCD digital display of inches of Hg, warning audible horn and
red light. System is plumbed to the Vac-Pack and monitors
vacuum level triggering the alarm in the event of vacuum
leakage detection.
■ Optional Water Trap
For wet applications: prevents saturation of filter and possible
damage to pump.
Specifications:
Vac-Pack
Model No.
Attach/Release
Control
VPF-57-DC (Standard)
Slide Valve
VPF-57-DCP (Optional)
Control Pendant
Pump Cap.
(scfm)
1.12
Vacuum Vacuum
Unit
Pump
Level
Weight
hp
(Sea Level) lb. (kg)
1/5
24” Hg
Generator
Power
Incoming Power Beam
Requirement
Size
for Charger
80 (36) 12V DC @ 12amp 120V/1PH/60Hz
3” Sq.
Vac-Pack Vacuum Generator
Battery Powered
132 00 296 • Revision: B
Effective Date: 02-11-03
Page 1 of 1
BATTERY CASE
OPTIONAL
GC-CHARGE-10
BATTERY
CHARGER
14.81
(376.2)
BAE1
Series
with ANVER VacGuard™
Vacuum Control System
12.38
(314.3)
25.25
(641.3)
3.31
(84.1)
2.63
(66.8)
ATTACH/RELEASE
CONTROLS
27.88 (708.1) REF.
8.00
(203.2)
3.44 (87.3)
12.38
(314.3)
ANVER’s BAE1 Series Vac-Pack Vacuum
Generator contains the same features as the standard VPE1 Series but includes a heavy duty
rechargeable 12 volt DC battery, making it suitable
for handling non-porous loads. It is commonly
used for special applications where AC power is
not readily available.
5.25 (133.3)
(4) 5/16-18 UNC
TAPPED HOLES
ANVER Item No.
Description
BAE1-RA
Remote Vacuum Station, Battery Powered
Features:
Vacuum Pump Specifications:
• VacGuard™ Vacuum Control System
This revolutionary solid-state Vacuum Control System combines
all the required vacuum generator controls in a rugged, compact
ABS enclosure. The VacGuard controls all vacuum pump functions, safety lights and can be fitted with an optional audible vacuum leakage warning system.
• The 2.2 CFM piston pump is driven by a 1/3 HP motor that
operates on 12 volts DC. The VacGuard Vacuum Control System
continuously attempts to maintain a safe vacuum level by cycling
the vacuum motor/pump on or off as required. The VacGuard high
and low vacuum limits are preset at the factory.
• Front Controls and Gauges:
All controls and gauges are mounted on the front of the unit for
easy access and viewing. The control pendant provides
attach/release at the operator’s fingertips. Gauges indicate the
level and stability of vacuum in the manifold and vacuum
reservoir.
• Indicator Lights
• Amber light indicates “power on” for Vac-Pack Vacuum
Generator.
• Green light indicates, “safe” vacuum level.
• Red light indicates, “unsafe” vacuum level.
• Battery charge indicator.
• Vacuum Retention
An internal check valve is included to prevent vacuum loss
through the manifold in the event of a power failure. A vacuum
reservoir assists in maintaining a safe vacuum level during a
power failure.
Maintenance:
• Bottom Hinged Front Cover and Removable Top Back Cover
For easy access to all components
• Clear Air Filter Cover:
Located on the front of the unit, the filter cover is clear for quick
inspection and unscrews for easy cleaning.
Frame Configuration:
• Standard Vac-Pack frame arranged for remote mounting
• Weight: 156 lb
Battery Specifications:
• 80 amp hour, sealed battery can provide full 8 hour shift operation
in many applications.
• Includes battery case with mounting brackets.
Options:
• Audible Vacuum Leakage Warning System (VLS-03E)
Integrated electronically controlled vacuum leakage sensor
monitors vacuum level and triggers a visual and audible alarm in
the event of an unsafe vacuum level.
• Other BAE1 Series Frame Configurations
Different frame configurations are available - consult factory for
further information.
• Battery Charger (GC-CHARGE-10)
Integrated 10 hw battery charger is an advanced battery charger
designed specifically for today’s high performance deep-cycle
lead-acid batteries. It provides microprocessor controlled threestep charging. The Twist-lock receptacles, both the male and
female are supplied, prevent accidental disconnection from the
110V AC power source. The charger is interlocked to prevent VacPack from being used during charging. A “charger on” indicator
light located on front cover of Vac-Pack will illuminate when
battery is being charged.
• Other Batteries
100 amp hour sealed batteries are available to increase operation
duration or for heavy duty applications.
13200296(Instrct)
ANVER Corp. • 36 Parmenter Road • Hudson MA 01749 USA • 978-568-0221 • 800-654-3500 • FAX 978-568-1570 • E-Mail: sales@anver.com • www.anver.com
Vacuum Pumps and Vacuum Generators
Electric Vac-Packs
VPE Series Self-Contained Vacuum Stations
Features:
• Complete Vacuum Station with quiet pump, reservoir and all necessary
controls
• Dry, oil-free pump avoids contamination
• Controls include:
• Power on-off switch
• Adjustable vacuum switch to control vacuum level
• Vacuum gauges, reservoir and manifolds
• Adjustable red/green indicator lights and adjustable low vacuum
warning horn
• Pendant switch attach/release
VACUUM ADJUSTMENT VALVE
Available Voltage
115-1-60
PMP-24
PMP-48
X
X
PMP-75
PUMP INT. MUFFLER
(991)
16.0 DIA.
(406)
230-1-60
X
X
X
230-3-60
X
X
X
460-3-60
X
X
X
575-3-60
X
X
X
110-1-50
X
X
X
X
220-1-50
PUMP INTERNAL FILTER
OILESS VACUUM
PUMP & MOTOR
39.00
X
220-3-50
X
X
X
380-3-50
X
X
X
440-3-50
X
X
X
575-3-50
X
X
X
MASTER POWER ON-OFF
BALL VALVE 1 " NPT
(TWO SIDES)
HEIGHT
CONTROL PENDANT
WITH VACUUM ATTACH
AND RELEASE SWITCH
30 GALLON
VACUUM
RESERVOIR
(4) 0.55 (14) DIA. HOLES
VPE24 & VPE48
PUMP INT. MUFFLER
PUMP INT. MUFFLER
RESETTABLE OVERLOAD
PROTECTOR
CLEAR FILTER
COVER
23.86
(606)
OILESS VACUUM
PUMP & MOTOR
RESERVOIR AND MANIFOLD
VACUUM GAUGES
LARGE RED AND GREEN
INDICATOR LIGHTS
22.0 X 14.25
(559 x 362)
MOUNTING HOLES
RESERVOIR AND MANIFOLD
VACUUM GAUGES
LARGE RED AND GREEN
INDICATOR LIGHTS
RESETTABLE OVERLOAD
PROTECTOR
MASTER POWER ON-OFF
CLEAR FILTER
COVER
VACUUM
ADJUSTMENT
VALVE
BALL VALVES
1" NPT
(TWO SIDES)
30 GALLON
VACUUM
RESERVOIR
39.00
(991)
16.54
(420)
FRONT
22.00
(559)
REAR
VPE75
CONTROL PENDANT
WITH VACUUM ATTACH
AND RELEASE SWITCH
ANVER
Item No.
Vacuum Flow
at 60 Hz
SCFM
(l/min.)
Vacuum Flow
at 50 Hz
SCFM
(l/min.)
Max. Vacuum
in. Hg
(mm Hg)
Motor
HP
(kW)
H Height
in.
(mm)
Weight
lb.
(Kg)
VPE24
24
(680)
20
(566)
26.5
(67.3)
1.5
(1.1)
35.38
(899)
295
(134)
VPE48
50
(1416)
40
(1133)
25.0
(63.5)
3
(2.2)
35.38
(899)
425
(193)
VPE75
75
(2124)
65
(1841)
25.0
(63.5)
5
(3.7)
43.13
(1100)
655
(297)
6021401
Vacuum Pumps and Generators
PMP Series Dry Rotary Vane Vacuum Pumps
ANVER's PMP-17, 24, 48, 75 and 100 Series
Rotary Vane Electric Vacuum Pumps
are quiet and durable vacuum pumps offering superior
performance and exceptional reliability.
These state-of-the-art oil-free pumps compare favorably
with lubricated pumps in noise levels and service, while
eliminating the danger of contamination.
The pumps do not emit oil fumes, thereby creating a
safer working environment and ensuring the purity of
product so important in the food, medical, electronics
and printing industries.
6020301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-17
Features:
• Oil free
• Maintenance free
• Operates quietly-maximum 70 dB (A)
• Cooler running outboard bearings
increase service life
• Built-in particulate filters and silencers
• Compact lightweight design
• Handles vacuum and/or pressure
applications
• Ideal alternative to standard oil sealed
rotary vane pumps
Performance Curves: 60Hz
Vacuum
Pressure
PSIG
“Hg
16
30
14
25
12
20
10
15
8
6
10
4
5
2
0
0
5
10
15
20
25
30
CFM
0
0
5
10
15
20
25
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
30
CFM
9032301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-17
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. in. Hg
lb
(kg)
w/o motor
-
-
17
25"
55
(25)
230/460V
1750
1
17
25"
72
(20)
115/230V
1750
1
17
25"
72
(20)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. PSI
lb
(kg)
w/o motor
-
-
17
14psig
55
(25)
230/460V
1750
1
17
14psig
72
(20)
115/230V
1750
1
17
14psig
72
(20)
NOTES:
a. Standard voltage for three phase pump is 230/460V 3ph 60Hz
b. Standard voltage for single phase pump is 115/230/1ph 50/60Hz
c. All pumps available in 208V/3ph/60Hz and 575 Volt 50/60 Hz. Contact factory for more information.
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-24
Features:
• Oil free
• Maintenance free
• Operates quietly-maximum 70 dB (A)
• Cooler running outboard bearings
increase service life
• Built-in particulate filters and silencers
• Compact lightweight design
• Handles vacuum and/or pressure
applications
• Ideal alternative to standard oil sealed
rotary vane pumps
Pressure
Performance Curves: 60Hz
Vacuum
PSIG
16
“Hg
30
14
25
12
FM
AC
20
10
8
FM
SC
15
6
10
4
2
5
0
0
0
5
10
15
20
25
0
5
10
15
20
25
30
CFM
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
30
CFM
9032301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-24
ø 0.39 (10) - [4]
ø 0.39 (10) - [4]
3.15
(80)
7.34
(186)
6.81 (173)
8.94 (277)
3.15
(80)
7.34
(186)
2.13
(54)
6.81 (173)
3.07
(78)
6.06 (154)
8.94 (277)
3.66
(93)
2.13
(54)
3.54
(90)
9.27
(235)
7.47
(190)
0.18
(5)
8.66 (220)
9.53 (242)
10.74 (273)
12.80 (325)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. in. Hg
lb
(kg)
w/o motor
-
-
24
27.5"
66
(30)
230/460V
1750
1.5
24
27.5"
97
(44)
115/230V
1750
1.5
24
27.5"
97
(44)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. PSI
lb
(kg)
w/o motor
-
-
24
14psig
66
(30)
230/460V
1750
1.5
24
14psig
97
(44)
115/230V
1750
1.5
24
14psig
97
(44)
NOTES:
a. Standard voltage for three phase pump is 230/460V 3ph 60Hz
b. Standard voltage for single phase pump is 115/230/1ph 50/60Hz
c. All pumps available in 208V/3ph/60Hz and 575 Volt 50/60 Hz. Contact factory for more information.
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-48
Features:
• Oil free
• Maintenance free
• Operates quietly-maximum 70 dB (A)
• Cooler running outboard bearings
increase service life
• Built-in particulate filters and silencers
• Compact lightweight design
• Handles vacuum and/or pressure
applications
• Ideal alternative to standard oil sealed
rotary vane pumps
Performance Curves: 60Hz
Vacuum
Pressure
PSIG
in. Hg
16
30
14
25
AC
12
FM
20
10
SC
8
FM
15
6
10
4
5
2
0
0
0
10
20
30
40
50
60
0
10
20
30
40
50
CFM
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
60
CFM
9032301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-48
1" NPT
7.76 (197)
4.37 (111)
ø 0.43 (11)
4.41
(112)
2.36 (60)
3.31
(84)
0.98 (25)
2.17 (55)
18.39 (467)
22.32 (567)
30.20 (767)
1.97
(50)
16.22 (412)
3.39
(86)
9.17 (233)
3.66
(93)
4.72 (120)
14.73
(374)
12.64
(321)
0)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. in. Hg
lb
(kg)
w/o motor
-
-
50
27.5"
170
(77)
230/460V
1200
3
50
27.5"
220
(100)
115/230V
1200
3
50
27.5"
235
(107)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. PSI
lb
(kg)
w/o motor
-
-
50
14psig
170
(77)
230/460V
1200
3
50
14psig
220
(100)
115/230V
1200
3
50
14psig
235
(107)
NOTES:
a. Standard voltage for three phase pump is 230/460V 3ph 60Hz
b. Standard voltage for single phase pump is 115/230/1ph 50/60Hz
c. All pumps available in 208V/3ph/60Hz and 575 Volt 50/60 Hz. Contact factory for more information.
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-75
Features:
• Oil free
• Maintenance free
• Operates quietly-maximum 70 dB (A)
• Cooler running outboard bearings
increase service life
• Built-in particulate filters and silencers
• Compact lightweight design
• Handles vacuum and/or pressure
applications
• Ideal alternative to standard oil sealed
rotary vane pumps
Pressure
Performance Curves: 60Hz
Vacuum
PSIG
in. Hg
16
30
14
25
12
M
F
AC
20
10
8
SC
FM
15
6
10
4
5
2
0
0
0
20
40
60
80
100
0
20
40
60
80
100
CFM
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
120
CFM
9032301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-75
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. in. Hg
lb
(kg)
w/o motor
-
-
75
25"
240
(109)
230/460V
1200
5
75
25"
288
(127)
115/230V
1200
5
75
25"
310
(141)
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. PSI
lb
(kg)
w/o motor
-
-
75
14psig
240
(109)
230/460V
1200
5
75
14psig
288
(127)
115/230V
1200
5
75
14psig
310
(141)
NOTES:
a. Standard voltage for three phase pump is 230/460V 3ph 60Hz
b. Standard voltage for single phase pump is 115/230/1ph 50/60Hz
c. All pumps available in 208V/3ph/60Hz and 575 Volt 50/60 Hz. Contact factory for more information.
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-150
Features:
• Oil free
• Maintenance free
• Operates quietly-maximum 70 dB (A)
• Cooler running outboard bearings
increase service life
• Built-in particulate filters and silencers
• Compact lightweight design
• Handles vacuum and/or pressure
applications
• Ideal alternative to standard oil sealed
rotary vane pumps
Performance Curves: 60Hz
Vacuum
in. Hg
30
25
AC
F
M
20
SC
FM
15
10
5
0
0
20
40
60
100
CFM
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
0112301
Vacuum Pumps and Vacuum Generators
Dry Rotary Vane Vacuum Pumps / PMP-150
Vacuum Specifications
Motor
RPM
Motor HP
(Kw)
Vacuum Flow
(CFM)
Max. in. Hg
lb
(kg)
w/o motor
-
-
150
27.5"
450
(205)
208-230/460V
1200
10
150
27.5"
522
(237)
NOTES:
a. Standard voltage for three phase pump is 208-230/460V/3ph 60Hz.
b. Standard voltage for single phase pump is 115/230/1ph 50/60Hz or 115V/1ph 60Hz or 230V/1ph 60Hz.
c. All pumps available in 50Hz frequency, and with other voltages. Contact Factory for more information.
Vacuum Pumps and Generators
Becker Oil Lubricated Rotary Vane Vacuum Pumps
The Becker AFM325 Oil Lubricated Vacuum Pump
is a quiet, high quality, rotary vane pump suited for most vacuum
applications. Single Stage and Air cooled, this direct driven pump
ensures the reliability and durability required in the vacuum industry.
Features:
• Composite Vane Material for long life
•
•
•
•
•
Oil level sight glass
Vibration isolators
Anti-suck back valve
Integral exhaust filters
Can be wired to 230V or 460V
HP
Flow
SCFM
(l/min.)
Sound
Level
dB
Max.
Vacuum
in. Hg
(mm Hg)
Speed
RPM
Oil Qty.
Quarts
Shipping
Weight
lb
(kg)
230
1.5
18
(510)
66.5
29.8
(757)
1725
1
92
(42)
460
1.5
18
(510)
66.5
29.8
(757)
1725
1
92
(42)
Model
Number
Voltage
AFM325-230
AFM325-460
2021401
Vacuum Pumps and Generators
Becker Oil Lubricated Rotary Vane Vacuum Pumps
29.83
29.6
29
28
26
22 18
0
"Hg
CPM 40
10
1
0
1
29.92
BHP 2.0
10
2
25
100
20
15
760 TORR
10
5
0
"Hg
1.5
1
.5
1
150
300
450
600
Specifications
Free Air Displacement [CFM] 60 Hz
18
Motor Capacity
1.5
Speed [RPM] 60 Hz
1725
Sound Level [dB(A)] 60 Hz
66.5
End Vacuum [Torr] - SA
2.0
Weight [Lb] [with motor]
92
Oil Quantity [Qt]
1
760 TORR
Vacuum Pumps and Generators
Small Oil Lubricated Rotary Vane Vacuum Pumps
ANVER's oil-flooded, multi-vane vacuum pumps are single
stage, air-cooled and direct driven. This simple design
ensures the reliability and durability that is required in the
vacuum industry.
Features:
•
•
•
•
•
•
•
•
•
Composite vane material for long life
Non metal or asbestos
Oil level site glass
Vibration isolators
Anti-suck back valve
Integral exhaust filters
TEFC high efficiency tri-voltage motors (208-230/460V 50.60)
Wire mesh inlet screen
Excellent performance for the price
AFM12 and AFM21 Series (Shown Above)
Performance Curves
29.83
in Hg
29.6
29
28
26
CFM 20
22
18
0
AFM21
10
AFM12
10
0
1
2
10
100
760
Torr
8013401
Vacuum Pumps and Generators
Oil Lubricated Rotary Vane Vacuum Pumps
Model
Number
Voltage
Free Air
Displacement
60 Hz
SCFM
(l/m)
AFM12-230
230
7
(198)
0.75
59
2.0 Torr
29.84” Hg
1750
.05
42
(19)
AFM12-460
460
7
(198)
0.75
59
2.0 Torr
29.84” Hg
1750
.05
42
(19)
AFM21-230
230
15
(425)
1.00
62
2.0 Torr
29.84” Hg
3600
.05
42
(19)
AFM21-460
460
15
(425)
1.00
62
2.0 Torr
29.84” Hg
3600
.05
42
(19)
Motor
Capacity
(HP)
60 Hz
Sound
Level
dB
End.
Vacuum
Standard
Speed
RPM
Oil Qty.
Quarts
Shipping
Weight
lb
(kg)
AFM25 and AFM40 Series (Shown Below)
Vacuum Pumps and Generators
Oil Lubricated Rotary Vane Vacuum Pumps
Performance Curves
29.83
29.6
29
28
26
22
InHg
0
18
CFM 40
H
10
H
L
L
1
0
.5
1
2
10
100
760
Torr
InHg
0
Power Consumption
29.82
BHP 2.0
25
20
15
10
5
1.5
40
25
1
.5
0
150
300
450
600
760
Torr
Model
Number
Voltage
Free Air
Displacement
60 Hz
SCFM
(l/m)
AFM25-230L
230
21
(595)
1.5
67
2.0 Torr
29.84” Hg
1725
1.0
103
(46.8)
AFM25-230H
230
21
(595)
1.5
67
2.0 Torr
29.90” Hg
1725
1.0
103
(46.8)
AFM25-460L
460
21
(595)
1.5
67
2.0 Torr
29.84” Hg
1725
1.0
103
(46.8)
AFM25-460H
460
21
(595)
1.5
67
2.0 Torr
29.90” Hg
1725
1.0
103
(46.8)
AFM40-230L
230
31
(878)
2.0
67
2.0 Torr
29.84” Hg
1725
1.0
116
(52.7)
AFM40-230H
230
31
(878)
2.0
67
2.0 Torr
29.90” Hg
1725
1.0
116
(52.7)
AFM40-460L
460
31
(878)
2.0
67
2.0 Torr
29.84” Hg
1725
1.0
116
(52.7)
31
(878)
2.0
67
2.0 Torr
29.90” Hg
1725
1.0
116
(52.7)
AFM40-460H
460
Motor
Capacity
(HP)
60 Hz
Sound
Level
dB
End.
Vacuum
Standard
Speed
RPM
Oil Qty.
Quarts
Shipping
Weight
lb
(kg)
8013401
Vacuum Pumps and Generators
Medium Oil Lubricated Rotary Vane Vacuum Pumps
AFM63 and AFM100 Series
ANVER's oil-flooded, multi-vane vacuum pumps are single
stage, air-cooled and direct driven. This simple design
ensures the reliability and durability that is required in the
vacuum industry.
Features:
•
•
•
•
•
•
•
•
•
Composite vane material for long life
Non metal or asbestos
Oil level site glass
Vibration isolators
Anti-suck back valve
Integral exhaust filters
TEFC high efficiency tri-voltage motors (208-230/460V 50.60)
Wire mesh inlet screen
Excellent performance for the price
2071401
Vacuum Pumps and Generators
Medium Oil Lubricated Rotary Vane Vacuum Pumps
Performance Curves
29.83
29.6
2
10
29
28
26
22
18
InHg
0
CFM 100
10
0
.5
1
100
760
Torr
Performance Curves
29.92
BHP 4
25
20
15
10
InHg
0
5
3
2
1
0
150
300
450
600
760
Torr
Voltage
Free Air
Displacement 60 Hz
SCFM
(l/m)
Motor
Capacity
(HP)
60 Hz
Sound
Level
dB
End.
Vacuum
Standard
Speed
RPM
Oil Qty.
Quarts
Shipping
Weight
lb
(kg)
AFM63-230L
230
45
(1275)
3.0
70
2.0 Torr
29.84” Hg
1725
2.0
168
(74.6)
AFM63-230H
230
45
(1275)
3.0
70
0.5 Torr
29.90” Hg
1725
2.0
168
(74.6)
AFM63-460L
460
45
(1275)
3.0
70
2.0 Torr
29.84” Hg
1725
2.0
168
(74.6)
AFM63-460H
460
45
(1275)
3.0
70
0.5 Torr
29.90” Hg
1725
2.0
168
(74.6)
AFM100-230L
230
70
(1982)
5.0
70
2.0 Torr
29.84” Hg
1725
2.0
185
(82.2)
AFM100-230H
230
70
(1982)
5.0
70
0.5 Torr
29.90” Hg
1725
2.0
185
(82.2)
AFM100-460L
460
70
(1982)
5.0
70
2.0 Torr
29.84” Hg
1725
2.0
185
(82.2)
AFM100-460H
460
70
(1982)
5.0
70
0.5 Torr
29.90” Hg
1725
2.0
185
(82.2)
Model
Number
Vacuum Pumps and Generators
Medium Oil Lubricated Rotary Vane Vacuum Pumps
AFM160 and AFM230 Series
ANVER's oil-flooded, multi-vane vacuum pumps are single
stage, air-cooled and direct driven. This simple design
ensures the reliability and durability that is required in the
vacuum industry.
Features:
•
•
•
•
•
•
•
•
•
Composite vane material for long life
Non metal or asbestos
Oil level site glass
Vibration isolators
Anti-suck back valve
Integral exhaust filters
TEFC high efficiency tri-voltage motors (208-230/460V 50.60)
Wire mesh inlet screen
Excellent performance for the price
2071401
Vacuum Pumps and Generators
Medium Oil Lubricated Rotary Vane Vacuum Pumps
Performance Curves
29.83
29.6
29
28
26
22
InHg
0
18
CFM 200
230
160
100
10
0
.5
1
2
10
100
760
Torr
InHg
0
Power Consumption
29.82
BHP 4
25
20
15
10
5
230
3
160
2
1
0
150
300
450
600
760
Torr
Voltage
Free Air
Displacement 60 Hz
SCFM
(l/m)
Motor
Capacity
(HP)
60 Hz
Sound
Level
dB
End.
Vacuum
Standard
Speed
RPM
Oil Qty.
Quarts
Shipping
Weight
lb
(kg)
AFM160-230L
230
112
(3172)
5.0
73
2.0 Torr
29.84” Hg
1725
7.0
306
(139)
AFM160-230H
230
112
(3172)
5.0
73
0.5 Torr
29.90” Hg
1725
7.0
306
(139)
AFM160-460L
460
112
(3172)
5.0
73
2.0 Torr
29.84” Hg
1725
7.0
306
(139)
AFM160-460H
460
112
(3172)
5.0
73
0.5 Torr
29.90” Hg
1725
7.0
306
(139)
AFM230-230L
230
155
(4390)
7.5
74
2.0 Torr
29.84” Hg
1725
7.0
377
(171)
AFM230-230H
230
155
(4390)
7.5
74
0.5 Torr
29.90” Hg
1725
7.0
377
(171)
AFM230-460L
460
155
(4390)
7.5
74
2.0 Torr
29.84” Hg
1725
7.0
377
(171)
AFM230-460H
460
155
(4390)
7.5
74
0.5 Torr
29.90” Hg
1725
7.0
377
(171)
Model
Number
Vacuum Pumps and Generators
Vacuum Pumps with Standard and Explosion Proof Motors
ANVER, in close cooperation with Siemens, offers select models of high
efficiency vacuum pumps specially designed for ANVER, and used as part of its
vacuum lifting systems. These revolutionary regenerative pumps offer a compact,
reliable source of quiet, vibration-free vacuum. ANVER's quality vacuum pumps
are made from tough, high-strength materials for long life, and are lightweight and
virtually maintenance free. Their highly efficient, state-of-the-art design has rendered
the older designs of conventional side-channel blowers obsolete. Vacuum pumps are
available in capacities of up to 480+ cfm flow and 18 in. Hg vacuum. Powered by
high quality TEFC Siemens motors, they are more energy efficient, require less
horsepower to operate than competitive models, and are offered in a variety of
sizes to match your vacuum lifting requirements.
ANVER's high efficiency vacuum pumps are also known as Regenerative
Blowers, Ring Compressors, Vortex Blowers, and Side-Channel Blowers by
other manufacturers. The difference with these pumps is the precision and quality
of parts used, allowing vacuum level and flow to be achieved with lower noise
levels. Most of these pumps can be used to create either vacuum or pressure flow.
The pumps ANVER offers are the highest quality on the market, with surprisingly low
prices in relation to their performance. These pumps are available as both complete
vacuum stations (which feature heavy duty mufflers and all appropriate connection
fittings), and as replacement units.
NOTE: Optional vacuum or pressure relief valves are also recommended.
Standard Regenerative Direct-Drive Vacuum Pumps and Vacuum Station Specifications
Note: Vacuum Stations include a large muffler and fittings
Complete
Station
Part Number
HP
(KW)
SCFM
(l/min.)
Max.
Vacuum
in. Hg
(mm Hg)
Pump
Part
Number
Sound
Enclosure
Shipping Wt.
lb
(kg)
VB3HF-S
3.4
(2.53)
142
(4021)
8
(203)
VB3HF
SDE-3
53
(23.5)
VB4HF-S
5.0
(3.73)
220
(6230)
12
(305)
VB4HF
SDE-4
75
(33.3)
VB7HV-S
5.0
(3.73)
98
(2775)
18
(457)
VB7HV
SDE-7
94
(41.70)
VB8HF-S
8.5
(6.34)
320
(9061)
12
(305)
VB8HF
SDE-8
277
(122.89)
VB9HV-S
7.5
(5.59)
124
(3511)
18
(457)
VB9HV
SDE-9
112
(49.69)
Explosion Proof Regenerative Vacuum Stations
Note: Vacuum Stations include a large muffler and connection fittings
Station
HP
Part
(KW)
Number
Class1/
Division1/
Group D
Class 1/
Division 1/
Group C&D
Class 1/
Division 1/
Group F&G
Explosion Proof Regenerative
Vacuum Pumps Only
Pump
HP
Part
(KW)
Number
Class1/
Division1/
Group D
Class 1/
Division 1/
Group C&D
Class 1/
Division 1/
Group F&G
VB4HF-S 4.8
VB4HF-S-X11D
VB4HF-S-X11CD VB4HF-S-X21FG
VB4HF
4.8
VB4HF-X11D
VB4HF-X11CD
VB4HF-X21FG
VB7HV-S 5.0
VB7HV-S-X11D
VB7HV-S-X11CD VB7HV-S-X21FG
VB7HV
5.0
VB7HV-X11D
VB7HV-X11CD
VB7HV-X21FG
VB8HF-S 8.5
VB8HF-S-X11D
VB8HF-S-X11CD VB8HF-S-X21FG
VB8HF
8.5
VB8HF-X11D
VB8HF-X11CD
VB8HF-X21FG
VB9HV-S 7.5
VB9HV-S-X11D
VB9HV-S-X11CD VB9HV-S-X21FG
VB9HV
7.5
VB9HV-X11D
VB9HV-X11CD
VB9HV-X21FG
➨ This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
4040501
Vacuum Pumps and Generators
VB Series Explosion-Proof Regenerative Pump VB3HF
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 73 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
208-230/415-460
10.0/5.0
3.42
3600
105
(260)
120
(300)
145
(250)
53
(24)
50
220/380/415
10.8/4.8/5.0
2.95
3000
90
(220)
110
(270)
125
(210)
53
(24)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
0170301
Vacuum Pumps and Generators
VB Series Explosion-Proof Regenerative Pump VB4HF
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 80 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
208-230/415-460
13.6/6.8
4.6
3600
112
(280)
107
(266)
220
(375)
75
(34)
50
220/380/415
15.0/6.8/6.6
4.0
3000
104
(260)
112
(280)
187
(320)
75
(34)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
0120301
Vacuum Pumps and Generators
VB Series Explosion-Proof Regenerative Pump VB7HV
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
240
17
220
16
15
200
14
180
13
12
160
11
140
10
95G
9
120
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
20
40
60
80
100
120
140
160
180
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
95G
TEFC
3.50
208-230/415-460
3-60Hz
10.1/5.0
88
(39.9)
70 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
0120301
Vacuum Pumps and Generators
VB Series Explosion-Proof Regenerative Pump VB8HF
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 75 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
208-230/415-460
24.0/12.0
8.5
3600
127
(315)
112
(280)
370
(630)
277
(126)
50
380/415
13.5/12.0
4.0
3000
108
(270)
122
(305)
312
(530)
277
(126)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
0120301
Vacuum Pumps and Generators
VB Series Explosion-Proof Regenerative Pump VB9HV
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 71 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
240
17
220
16
15
200
14
180
13
12
160
11
140
10
125G
120
9
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
20
40
60
80
100
120
140
160
180
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
125G
TEFC
5.1
208-230/415-460
3-60Hz
14.9/7.5
106
(48.1)
71 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
0180301
Vacuum Pumps and Generators
High Flow RB Series Regenerative Vacuum Pumps
ANVER, in close cooperation with Siemens®, now introduces an
extended range of our High Flow series Regenerative Vacuum
Pumps. These pumps offer an incredibly compact, quiet, reliable
source of vacuum and compressed air. We now carry eight new
models, making it easy to find the pump best suited for your
vacuum or pressure needs.
Features:
•
•
•
•
•
•
Oil and Maintenance Free
Operates Quietly - as low as 80 dB
Outboard Bearings increase service life - runs cooler
Compact, Light-weight design - Easy to Install
Good for both Vacuum and Pressure Applications
Ideal Alternative to standard Rotary Vane Pumps
and PD/Rotary Lobe Blowers
• Wired to 230/460 Volts
HP
SCFM
(l/min.)
Max.
Vacuum
in. Hg
(mm Hg)
Amps
Shipping
Wt.
lb
(kg)
2BH13007AH16
0.87
53
(1500)
4.5
(114)
2.8 / 1.4
22
(10)
RB-100-10
2BH14107HH46
3.40
106
(3002)
10.5
(267)
10.0 / 5.0
59
(27)
RB-122-10
2BH15107HH46
4.60
152
(4305)
12.5
(318)
13.0 / 6.5
84
(38)
RB-175-11
2BH16107HH46
8.50
225
(6372)
13
(330)
23.0 / 11.5
154
(70)
RB-330-14
2BH18107HH36
17.00
335
(9487)
14.5
(368)
46.0 / 23.0
452
(205)
RB-735-08
2BH19007AH16
21.00
690
(19540)
9
(229)
48.0 / 24.0
420
(191)
RB-750-11
2BH19107HH
27.00
780
(22090)
11
(279)
72.0 / 36.0
612
(278)
Anver
Part
Number
Seimens
Part
Number
RB-053-05
Typical Applications:
• Material Handling
• Packaging Machinery
• Vacuum Chucking
• Bagging & Bottling
• Thermoforming
• Medical Equipment
• Pneumatic Conveying
Note: Not Recommended for use with Vacuum Tube Lifting Systems.
See our Standard VB Series Regenerative Vacuum Stations specifically
designed for use with vacuum tube lifting systems.
 This spec sheet was adapted for print from our website. Additional information and photos are available at www.anver.com.
4041401
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-053-05
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• Quiet operation; as low as 61 dB(A)
• Easily mounts in any axle orientation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• IP54 with Class F insulation.
• Quality assured; manufactured in
accordance with ISO 9001.
• UL Recognized, CE Compliant.
DNE VDE 0530
• Thermal overload protection
standard on all models.
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
208-230/
415-460
2.8/1.4
.67
3600
60
(150)
68
(170)
53
(89)
22
(10)
50
220/380/415
2.1/1.1/1.0
.54
3000
48
(120)
52
(130)
46
(78)
22
(10)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9052301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-059-08
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• Quiet operation; as low as 66 dB(A)
• Easily mounts in any axle orientation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• IP54 with Class F insulation.
• Quality assured; manufactured in
accordance with ISO 9001.
• UL Recognized, CE Compliant.
DNE VDE 0530
• Thermal overload protection
standard on all models.
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
5.6/2.8
1.88
3600
110
(280)
135
(335)
59
(100)
37
(17)
50
200/400
5.8/2.9
1.6
3000
110
(280)
110
(270)
50
(85)
37
(17)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9052301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-100-10
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• Quiet operation; as low as 69 dB(A)
• Easily mounts in any axle orientation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• IP54 with Class F insulation.
• Quality assured; manufactured in
accordance with ISO 9001.
• UL Recognized, CE Compliant.
DNE VDE 0530
• Thermal overload protection
standard on all models.
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
10.0/5.0
3.4
3600
140
(350)
175
(440)
100
(175)
59
(27)
50
200/400
10.0/5.0
2.95
3000
110
(280)
150
(375)
85
(155)
59
(27)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9052301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-122-10
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• Quiet operation; as low as 77 dB(A)
• Easily mounts in any axle orientation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• IP54 with Class F insulation.
• Quality assured; manufactured in
accordance with ISO 9001.
• UL Recognized, CE Compliant.
DNE VDE 0530
• Thermal overload protection
standard on all models.
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
13.0/6.5
4.6
3600
165
(400)
170
(425)
145
(260)
84
(38)
50
200/400
13.0/6.5
4.0
3000
140
(350)
170
(420)
122
(220)
84
(38)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9062301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-175-11
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 79 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
23.0/11.5
8.5
3600
175
(430)
215
(530)
210
(375)
154
(70)
50
345-380
23.0/11.5
7.4
3000
165
(400)
215
(530)
175
(315)
154
(70)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9003301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-330-14
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 75 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
46.0/23.0
17
3600
200
(500)
265
(660)
330
(590)
452
(205)
50
200-400
46.0/23.0
14.75
3000
185
(460)
260
(640)
275
(490)
452
(205)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9003301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-735-08
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 80 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
48.0/24.0
21
3600
116
(290)
108
(270)
735
(1250)
420
(191)
50
200-400
48.0/24.0
16.5
3000
124
(310)
120
(300)
617
(1050)
420
(191)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
9003301
Vacuum Pumps and Generators
RB Series High Flow Regenerative Pump RB-750-11
Features:
• Cooler running, outboard bearing
provides virtually maintenance-free
operation in continuous duty service.
• Thermal overload protection
standard on all models.
• Quiet operation; as low as 80 dB(A)
• Equipped with high quality TEFC
motors manufactured by Siemens,
sized to match your operating
requirements providing for superior
power efficiency.
• Easily mounts in any axle orientation.
• IP54 with Class F insulation.
• Shock absorbing mounting plate
design reduces transmission of
vibration between process machinery
and the blower.
• Quality assured; manufactured in
accordance with ISO 9001.
• Environmentally friendly oil-free
design prevents downstream
contamination of gas or components.
• UL Recognized, CE Compliant.
DNE VDE 0530
Hz
Voltage
Range
Rated
Amps
Rated
HP
RPM
Maximum Vacuum
in H20
mbar
Maximum Pressure
in H20
mbar
Maximum Flow
CFM
m3h
Net Weight
lb
kg
60
230/460
72.0/36.0
26.8
3600
150
(380)
130
(320)
795
(1350)
612
(278)
50
200-400
76.0/38.0
22.8
3000
165
(410)
150
(370)
650
(1100)
612
(278)
NOTES:
A) Performance tolerance is ±10%.
B) Performance curves are based on an air temperature of 60° F (15° C) at the inlet connection
and 29.92 Hg abs (1013 mbar) at the discharge connection.
Specification and performance data are subject to change without notice. Please contact factory for specification updates.
0110301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Vacuum Pumps
In order to remain a leader in the vacuum equipment field, ANVER is constantly expanding its
range of products. We are pleased to announce the addition of nine new models in our High
Vacuum / Pressure Regenerative Pump line. Our close relationship with Siemens® allows us
to offer these high quality pumps at extremely competitive prices. These pumps are suitable
for a variety of vacuum and pressure applications. However, they are not recommended for
Vacuum Tube Lifting Systems.
Features:
•
•
•
•
•
•
Models: RB-036-11, RB-050-13, RB-061-12
Oil and Maintenance Free
Operates Quietly - maximum 72 dB
Outboard Bearings increase service life - runs cooler
Compact, Light-weight design - Easy to Install
Good for both Vacuum and Pressure Applications
Ideal Alternative to standard Rotary Vane Pumps
and PD/Rotary Lobe Blowers
• Can be wired at either 208-230 or 415-460
Anver
Part
Number
Seimens
Part
Number
HP
SCFM
(l/min.)
Max.
Vacuum
in. Hg
(mm Hg)
Rated
Amps
Shipping
Wt.
lb
(kg)
RB-035-08
2BH7210OAK127
0.85
35
(991)
8
(203)
3.2 / 1.6
35
(16)
RB-036-11
2BH7220OAH267
1.26
35
(991)
12
(304)
4.2 / 2.1
52
(24)
RB-050-09
2BH7310OAK127
0.80
50
(1416)
8
(203)
3.2 / 1.6
35
(16)
RB-050-13
2BH7320OAK42
1.75
50
(1416)
13
(330)
5.4 / 2.7
62
(28)
RB-062-10
2BH7410OAH167
1.75
65
(1841)
10
(254)
6.2 / 3.1
51
(23)
RB-061-12
2BH7420OAH26
2.40
61
(1727)
13
(330)
7.0 / 3.5
73
(33)
RB-090-11
2BH7510OAH168
2.35
90
(2549)
11
(279)
7.2 / 3.6
57
(26)
RB-119-11
2BH7610OAK12
3.50
120
(3398)
11
(279)
10.7 / 5.4
71
(32)
RB-120-20
2BH7630OAH6682
7.60
120
(3398)
20
(508)
20.0 / 10.0
104
(47)
Models:
Model:
RB-035-08
RB-050-09
RB-062-10,
RB-090-11
RB-119-11
RB-120-20
4041401
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-035-08
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
120
8.75
110
8
100
7
90
6
80
2G
70
5
60
4
50
3
40
30
2
20
1
10
0
0
10
20
30
40
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
2G
TEFC
0.85
208-230/415-460
3-60Hz
3.2/1.6
35
(15.9)
62 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9061301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-036-11
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
240
17.75
17
220
16
15
200
14
180
13
12
160
11
140
10
6G
120
9
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
10
20
30
40
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
6G
TEFC
1.26
208-230/415-460
3-60Hz
4.2/2.1
52
(23.6)
62 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9061301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-050-09
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
120
8.75
110
8
100
7
90
6
31G
80
70
5
60
4
50
3
40
30
2
20
1
10
0
0
10
20
30
40
50
60
70
80
90
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
31G
TEFC
0.80
208-230/415-460
3-60Hz
3.2/1.6
35
(15.9)
62 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9061301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-050-13
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
240
17
220
16
15
200
14
180
13
12
160
11
140
10
35G
120
9
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
10
20
30
40
50
60
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
35G
TEFC
1.75
208-230/415-460
3-60Hz
5.4/2.7
62
(28.1)
62 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9022301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-062-10
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
140
10
9
120
8
100
7
61G
6
80
5
60
4
3
40
2
20
1
0
0
0
20
40
60
80
100
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
61G
TEFC
1.75
208-230/415-460
3-60Hz
6.2/3.1
51
(15.9)
62 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9022301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-061-12
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
240
17
220
16
15
200
14
180
13
12
160
11
140
65G
10
9
120
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
10
20
30
40
50
60
70
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
65G
TEFC
2.40
208-230/415-460
3-60Hz
7.0/3.5
73
(33.1)
66 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9022301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-090-11
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
160
12
11
140
10
120
9
8
100
91G
7
80
6
5
60
4
40
3
2
20
1
0
0
10
20
30
40
50
60
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
91G
TEFC
2.35
208-230/415-460
3-60Hz
7.2/3.6
35
(15.9)
68 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9032301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-119-11
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
13
180
12
160
11
140
10
9
120
121G
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
20
40
60
80
100
120
140
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
121G
TEFC
3.5
208-230/415-460
3-60Hz
10.7/5.4
71
(32.2)
71 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9032301
Vacuum Pumps and Generators
High Vacuum RB Series Regenerative Pump RB-120-20
Features:
•
•
•
•
•
•
•
Oil free
Maintenance free
Operates quietly - maximum 70 dB (A)
Cooler running outboard bearings
increase service life
Easy to install, close-coupled construction
Compact lightweight design
Ideal alternative to standard rotary vane pumps
and PD/rotary lobe blowers
Performance Curves: 60Hz
Vacuum
in. H20
in. Hg
340
24.75
24
320
23
300
22
21
280
20
19
260
18
240
17
161G
220
16
15
200
14
180
13
12
160
11
140
10
120
9
8
100
7
80
6
5
60
4
3
40
2
20
1
0
0
20
40
60
80
100
120
140
160
180
0
CFM
Curve No.
Motor
Type
Motor HP
(Kw)
Voltage
PhaseFrequency
Rated
Motor
Amps
Shipping Weight
lb
(kg)
Sound
Level
161G
TEFC
7.5
208-230/415-460
3-60Hz
20/10
104
(47.2)
72 dB(A)
NOTES:
A) Standard voltage for three phase blowers is 208-230/415-460V 3ph/ 60Hz.
B) Standard voltage for single phase blowers is 115/230/1ph/50/60Hz or 115V/1ph/60Hz or 230V/1ph/60Hz.
C) AII blowers available in 50Hz frequency and with other voltages.
D) All blowers operate at 3600 RPM.
Specifications subject to change without notice. • Please contact factory for specification updates.
9042301
Vacuum Pumps and Generators
Water-Cooled Electric Vacuum Pumps
TCP Series
Manufactured by Siemens®, the ANVER TCP Series Electric Vacuum Pumps
are ideal alternatives to rotary vane vacuum pumps. This revolutionary product is remarkably easy to use... just plug it in and let it run. Take a close look
at the TCP's features and you'll agree that vacuum technology has taken a
giant leap forward. With an operating temperature that stays below 110° F
(43° C), the patented TCP cools exhausted air below the intake temperature
and dries it at the same time. Cool, clean air is the only thing discharged.
Condensed water returns to the internal water system, so there is no need for
an external water supply. An optional Overflow/Make-Up Valve automatically
adds or drains water in order to keep the appropriate level at all times.
Principle of Operation
Heat is removed from the closed loop water circuit by an air-cooled heat
exchanger. A small amount of water from the closed loop water circuit is
injected at the inlet of the TCP vacuum pump. Under vacuum, this stream is
vaporized and, as a result, the inlet air to the pump is cooled. Utilizing a shell
and tube heat exchanger, the cooled inlet air in turn cools the exhaust air
stream. Water vapor in the exhaust air is condensed and returned to the separator tank.
Typical Application
• Ground Water Extraction
• Food and Pharmaceutical Packaging
• Thermoforming
• Rubber Molding
• Medical and Anesthesia Evacuation
• Pick and Place
• Vacuum Routing
• Pneumatic Vacuum Conveying
• Central Vacuum Systems
Features:
• Oil free
• Maintenance free
• Self-contained internal water circuit
• Compact, quiet, cool running
• Capacity of 20 to 180 cfm; generates 28.5 inches of Hg Vacuum
• Insensitive to dust and water vapor
• Discharges totally clean air
Item
Number
HP
(Kw)
Max. Vacuum
in. Hg
(mm Hg)
Max. Flow
SCFM
(l/min.)
3 Phase Voltage
Amps
Sound
dB
TCP-20
1.4
(1.0)
28.5
(724)
20
(566)
200-275 / 345-480
5.6 / 2.8
66
95
(43)
TCP-35
2.2
(1.6)
28.5
(724)
40
(1133)
200-275 / 345-480
7.2 / 3.6
67
TCP-50
4.7
(3.5)
28.5
(724)
50
(1416)
200-275 / 345-480
13.2 / 6.6
72
130
(59)
191
(87)
TCP-80
6.8
(5.1)
28.5
(724)
80
(2266)
200-275 / 345-480
21.0 / 11.0
73
232
(105)
TCP-105
7.5
(5.6)
28.5
(724)
105
(2973)
208-230 / 415-480
22.0 / 11.0
71
396
(180)
TCP-140
10
(7.5)
28.5
(724)
140
(3964)
208-230 / 415-480
27.8 / 13.9
73
408
(185)
TCP-180
15
(11.2)
28.5
(724)
180
(5047)
208-230 / 415-480
42.0 / 21.0
73
506
(229)
Weight
lb
(kg)
Optional Accessories for TCP Series Vacuum Pumps
TCP-OV
TCP-MV1
TCP-MV2
Overflow / Make-Up Valve for TCP Series Pumps
Makeup Valve for TCP-20 and TCP-35 Pumps
Makeup Valve for TCP-50 through TCP-180 Pumps
8011401
Vacuum Pumps and Generators
Water-Cooled Electric Vacuum Pumps
Item
Number
a
in.
(mm)
b
in.
(mm)
c
in.
(mm)
f
in.
(mm)
g
in.
(mm)
h1
in.
(mm)
h2
in.
(mm)
h3
in.
(mm)
i1
in.
(mm)
i2
in.
(mm)
j
in.
(mm)
k
in.
(mm)
l
in.
(mm)
m1
in.
(mm)
m2
in.
(mm)
TCP-20
23.7
(602)
15.4
(390)
17
(432)
13.6
(345)
14.6
(370)
1
(25)
8.3
(210)
10.7
(272)
18.2
(463)
19.1
(486)
4.8
(121)
2.8
(70)
3.1
(80)
4.8
(122)
4.6
(116)
TCP-35
29.2
(743)
17.2
(436)
22.5
(572)
17.7
(450)
19.5
(495)
1
(25)
8.6
(218)
10.9
(278)
20.6
(522)
21.8
(553)
7
(178)
4.3
(108)
3.3
(85)
6.4
(162)
4.7
(120)
TCP-50
30.0
(761)
17.2
(436)
22.5
(572)
17.7
(450)
19.5
(495)
1
(25)
8.6
(218)
10.9
(278)
20.6
(522)
21.8
(553)
7
(178)
4.3
(108)
3.3
(85)
6.4
(162)
4.7
(120)
TCP-80
36.4
(920)
20.1
(511)
26.9
(682)
22.4
(570)
23.0
(585)
1
(25)
7.0
(179)
9.4
(239)
23.8
(605)
25.0
(636)
4.1
(104)
6.9
(174)
3.5
(90)
8.9
(225)
6.4
(162)
Item
Number
n
in.
(mm)
o
in.
(mm)
p
in.
(mm)
p1
in.
(mm)
p2
in.
(mm)
t1
in.
(mm)
t2
in.
(mm)
N1.0
in.
(mm)
N3.3
in.
(mm)
N3.4
in.
(mm)
N4.6
TCP-20
1.6
(40)
1.4
(36)
15
(380)
2.5
(63)
5.8
(148)
10.0
(255)
10.8
(274)
G3/4" ø1.2
(G3/4" ø30)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
TCP-35
1.4
(35)
1.5
(39)
20.2
(514)
4.3
(108)
7.1
(180)
12.4
(314)
13.5
(342)
G1-1/4" ø2
(G1-1/4" ø50)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
TCP-50
1.4
(35)
1.5
(39)
20.2
(514)
4.3
(108)
13.4
(341)
14.4
(367)
16.5
(419)
G1-1/4" ø2
(G1-1/4" ø50)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
TCP-80
1.4
(35)
1.9
(49)
22.0
(559)
3.2
(81)
13.4
(341)
14.4
(367)
16.5
(419)
G1-1/4" ø2
(G1-1/4" ø50)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
8011401
Vacuum Pumps and Generators
Water-Cooled Electric Vacuum Pumps
Item
Number
a
in.
(mm)
b
in.
(mm)
c
in.
(mm)
f
in.
(mm)
g
in.
(mm)
h1
in.
(mm)
h2
in.
(mm)
i
in.
(mm)
j
in.
(mm)
k
in.
(mm)
l
in.
(mm)
m
in.
(mm)
TCP-105
43.3
(1100)
24.8
(630)
33.3
(845)
29.7
(755)
28.5
(725)
1.2
(30)
13.1
(335)
27.9
(710)
9.4
(240)
4.7
(120)
3.5
(90)
12.2
(310)
TCP-140
43.3
(1100)
24.8
(630)
33.3
(845)
29.7
(755)
28.5
(725)
1.2
(30)
13.1
(335)
27.9
(710)
9.4
(240)
4.7
(120)
3.5
(90)
12.2
(310)
TCP-180
43.3
(1100)
24.8
(630)
33.3
(845)
29.7
(755)
28.5
(725)
1.2
(30)
11.6
(295)
27.9
(710)
9.4
(240)
4.7
(120)
3.5
(90)
12.2
(310)
Item
Number
n
in.
(mm)
o
in.
(mm)
p
in.
(mm)
p2
in.
(mm)
t1
in.
(mm)
t2
in.
(mm)
N1.0
in.
(mm)
N3.3
in.
(mm)
N3.4
in.
(mm)
N4.6
N7.0
TCP-105
1.4
(35)
2.4
(60)
29.8
(757)
13.2
(335)
15.9
(406)
21.6
(548)
2.5
(63)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
G1/8"
TCP-140
1.4
(35)
2.4
(60)
29.8
(757)
13.2
(335)
15.9
(406)
21.6
(548)
2.5
(63)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
G1/8"
TCP-180
1.4
(35)
2.4
(60)
29.8
(757)
13.2
(335)
15.9
(406)
21.6
(548)
2.5
(63)
S2.2 x 0.16
(S56 x 4)
S2.2 x 0.16
(S56 x 4)
G1"
G1/8"
8011401
Vacuum Pumps and Vacuum Generators
Vacuum Pump Accessories
Sound Enclosures for Vacuum Pump and Vacuum Stations
ANVER Vacuum Tube Lifting Systems use vacuum pumps and vacuum stations that
already meet OSHA guidelines for noise levels. For added comfort or for use where
low noise is desired as a premium, sound deadening enclosures are available in
most common sizes.
As a general rule, sound enclosures reduce sound by 5-7 dB for vacuum pumps
operating in the 68-76 dB range. Although this may seem vague, it is true since
sound readings can vary by this amount simply by changing the location where you
are standing when you are taking the sound readings.
ANVER sound deadening enclosures are built
from durable, melt-resistant, industrial-quality
plastic. They have a steel plate base and are fully
lined with sound deadening foam. It is best to
obtain these enclosures when you purchase the
vacuum station as they require special plumbing: the intake and exhaust pipes need to be lengthened to
port correctly.
7/16" (11 mm) DIA.
MOUNTING HOLES
D
E
The following enclosure sizes are available from stock. Note that the pricing is for the sound enclosure
when sold with the vacuum station. When sold separately, extra pipe fittings, though a small amount,
must be added. Check with the factory for details.
ANVER Item No.
A
in.
(mm)
B
in.
(mm)
C
in.
(mm)
D
in.
(mm)
E
in.
(mm)
SDE-3
33.00
(838)
24.00
(610)
21.50
(545)
N/A
N/A
SDE-4
33.00
(838)
24.00
(610)
21.50
(545)
35.00
(889)
11.40
(290)
SDE-5
33.00
(838)
24.00
(610)
21.50
(545)
35.00
(889)
12.92
(328)
SDE-6
33.00
(838)
24.00
(610)
21.50
(545)
35.00
(889)
12.92
(328)
SDE-7
33.00
(838)
24.00
(610)
21.50
(545)
35.00
(889)
12.92
(328)
SDE-8
38.75
(984)
30.00
(762)
29.25
(743)
N/A
N/A
SDE-9
33.00
(838)
24.00
(610)
21.50
(545)
35.00
(889)
14.64
(372)
Wall Mount Bracket for Regenerative Vacuum Pumps
ø0.53 (13.5) HOLES
FOR WALL MOUNTING
ø0.50 (12.7) HOLES
FOR PILLAR MOUNTING
MOUNTING HOLES ACCEPT
VB SERIES GENERATORS
27.50
(699)
ANVER Item No.
ST-W1
18.25
(464)
9.00
(229)
14.88
(378)
27.50
(699)
35.00
(889)
38.56
(979)
7091401
Vacuum Pumps and Vacuum Generators
Motor Starters and Protectors for Vacuum Pumps
ANVER Motor Starters are made for us in Germany to the highest quality
standards. The motor circuit controller combines the function of:
• Short circuit protection
• Thermal overload protection
• Switching and
• Signaling
Ideal for group motor installations...
ANVER starters can eliminate the need for larger and more expensive fuse
blocks and fused disconnects, or circuit breakers.
ANVER starters offer a wide application range, from 0.1 to 90 FLA in installations up to 600 V. For group motor applications, ANVER starters have up to
2000A group installation rating, one of the highest in the industry.
...or as a manual starter
ANVER starters are also excellent as manual motor starters that employ all of the same motor protection features in one compact
unit. ANVER starters are available in a variety of enclosures including general purpose, watertight and explosion-proof (the most compact on the market today).
In the event of a short-circuit, the contacts are opened by magnetic, non-adjusting tripping elements in times approaching 1/1000 of a
second. Because of this superb current limiting capability, ANVER starters have a short-circuit capacity of up to 42kA at 600 V.
Because each ANVER starter is individually calibrated at the factory for the smallest and largest current, very accurate thermal overload protection is also obtained. In addition, ANVER starters are Class 10 devices - they trip within 10 seconds under a locked rotor
condition (6 X FLA). Each motor starter must be ordered with an enclosure Part Number ST-ENCL).
Amperage Range
ANVER
Item No.
Minimum
Maximum
ST-025-040
2.50
4.00
ST-040-063
4.00
ST-063-100
Maximum HP
Phase
230V
460V
575V
Three
3/4
2
3
6.29
Three
1-1/2
3
5
6.30
9.99
Three
3
5
7-1/2
ST-100-160
10.00
15.99
Three
5
10
10
ST-160-200
16.00
19.99
Three
5
10
15
ST-200-250
20.00
25.00
Three
7-1/2
15
20
ST-ENCL
2051501
Enclosure, for Motor Starters (fits all above sizes)
Vacuum Pumps and Vacuum Generators
Motor Starters and Protectors for Vacuum Pumps
ANVER
Pump No.
VB3HF
VB4HF
VB6
VB7HV
VB8HF
VB9HV
HP
3.4
4.6
7.5
3.5
8.5
7.5
Starter No.
Voltage
Amps
ST-100-160
208-230
10
ST-040-063
460
5
ST-040-063
575
4
ST-100-160
208-230
13.6
ST-063-100
460
6.8
ST-040-063
575
5
ST-200-250
208-230
18.5
ST-063-100
460
8.6
ST-063-100
575
6.8
ST-100-160
208-230
12.2
ST-063-100
460
6.1
ST-025-040
575
3.8
ST-200-250
208-230
24
ST-100-160
460
12
ST-100-160
575
9.6
ST-160-200
208-230
14.9
ST-063-100
460
7.5
ST-040-063
575
5.2
Port Size
Hose
in.
(mm)
1-1/4"NPT
1-1/2
(38.1)
2" NPT
2
(50.8)
2" Barb
2
(50.8)
1-1/4" NPT
2
(50.8)
2" NPT
2
(50.8)
1-1/4" NPT
2
(50.8)
2051501