Date Sheet
J
J
AC/DC current measurement (TRUE RMS)
Range
Resolution
Accuracy
(DC)
Accuracy
(AC)
0...659,9A
0,1A
±(2,5% m.v. +5 digits)
±(2,5% m.v. + 8 digits)
for f=50...60Hz
660...1000A
1A
±(2,8% m.v. +8 digits)
±(2,8% m.v. + 8 digits)
for f=50...60Hz
DC voltage measurement
Range
Resolution
0...6,599V
0,001V
6,60...65,99V
0,01V
66,0...600,0V
0,1V
Accuracy
±(1,5% m.v. + 3 digits)
AC voltage measurement (TRUE RMS)
Range
Resolution
0...6,599V
0,001V
6,60...65,99V
0,01V
66,0...600,0V
0,1V
Accuracy
±(1,8% m.v. + 5 digits)
for f=50...60Hz
Resistance measurement
Range
Electric security:
- measurement category
- protection class acc. to EN 60529
Other technical data:
- power supply
- display
- continuity test
- diode test
- low battery indication
- over range indication
- sampling rate
- INRUSH
- temperature sensor
- input impedance
- AC bandwidth
- auto power OFF
- dimensions
- weight
- accordance with following standards
- quality standard
Rated operational conditions:
- internal clamp diameters
- operating temperature
- storage temperature
- operating humidity
- storage humidity
- operating altitude
CAT III 600V acc. to EN 61010-1:2004
IP40
9V battery type 6LR61
6600 counts, backlit LCD
threshold 40Ω; test current < 0,5mA
test current of 0,3mA, typical
open circuit voltage < 3V DC, typical
BAT displayed
0L displayed
2 times per second
integration time 100ms
type K thermocouple
10MΩ (V DC and V AC)
50...400Hz (A AC and V AC)
approx. 25 min.
229 x 80 x 49 mm
303 g
EN 61010-1:2004
EN 61010-2-032
ISO 9001
d1=36mm/d2=52mm
+5...+40°C
-20...+60°C
max 80% up to 31°C
decreasing linearly to 50% at 40°C
<80%
max 2000 m
Resolution
Accuracy
±(1,0% m.v. + 4 digits)
0,0...659,9Ω
0,1Ω
0,660...6,599kΩ
0,001kΩ
6,60...65,99kΩ
0,01kΩ
66,0...659,9kΩ
0,1kΩ
0,660...6,599MΩ
0,001MΩ
±(2,5% m.v. + 3 digits)
6,60...66,00MΩ
0,01MΩ
±(3,5% m.v. + 5 digits)
±(1,5% m.v. + 2 digits)
Frequency measurement
Range
Resolution
Accuracy
30,0...999,9Hz
0,1Hz
1,000...9,999kHz
0,001kHz
10,00...15,00kHz
0,01kHz
±(1.2% m.v. + 2 digits)
sensitivity: 30...5kHz:10Vrms min.
5kHz...15kHz:40Vrms min.
for 20%...80% duty cycle
Range
Resolution
Accuracy
-20...760°C
1°C
±(3,0% m.v. + 5°C)
-4...1400°F
1°F
±(3,0% m.v. + 9°F)
Temperature measurement
Duty cycle measurement
Range
Resolution
Accuracy
10,0...94,9%
0,1%
±(1,2% m.v. + 2 digits)
pulse width: 100μs...100ms,
frequency range: 30Hz...5kHz,
sensitivity: 30Hz...5kHz: 10Vrms,
5kHz...15kHz: 40Vrms.
„m.v.”- measured value