INSTRUCTION MANUAL IM471-U v0.2 EMI-10L Introduction EMI-10L converter lets you convert a serial RS485 communications port on a bus Ethernet with TCP / IP. The concepts and terms commonly used in the TCP / IP incorporated in this manual are: Transmission Control Protocol (TCP) TCP is a connection-oriented protocol, it can transmit data to establish communication, negotiating a connection between sender and recipient, and finally concludes with the closing of the connection. It therefore has the capability to create, maintain and close a connection. TCP guarantees that data transmitted, if they reach their destination, they do so in order and only once: the protocol into practice trying to simulate a direct physical connection of a stream of bytes through various mechanisms, acknowledgment and retransmission on timeout. Each connection is associated with an active TCP socket opened by a process. TCP is responsible for changing data between the active connections and related processes. For this, each connection between two hosts is associated with a port number on each of the two hosts, which is an unsigned 16-bit (1-65535), contained in the appropriate field header. A TCP connection will be identified by IP addresses of two hosts and ports used on the two hosts. EMI-10L Features The EMI-10L This is a bridge between MODBUS/TCPIP and Modbus /RTU. The serial port is connected to a MODBUS/RTU device or a network of devices, while the Ethernet port is connected to the server/PC or PLC systems. Commands are sent from the server via Ethernet, and the slave device gets these after they've been converted. Serial-Over-IP: RS232 ports may have disappeared from your PC but serial interfaces continue to be widespread in many industries such as security, automation and IT. EMI-10L's serial-over-IP solutions marry the simplicity of serial communications with TCP/IP networking of the Internet age. We supply external device, embedded Ethernet modules, and PC software that allow you to quickly network-enable practically any serial device. Configuration This manual applies to firmware version " app-emi10L-1_02” updates firmware may change the structure of the configuration menu and the name of some fields, indicating the procedure be followed to configure the device remains unchanged. DEFAULT SETTINGS IP Address 10.0.0.100 Subnetmask 255.0.0.0 Gateway 10.0.0.254 TCP Port 502 DHCP Disabled Username admin Password admin Restore to default parameters Power off the instruments. Power on the instruments. Wait for end of blinking green led. Press and hold the button for at least 10 seconds. EMI-10L user manual IM471-U v0.2 pag. 1 Common tasks In any configuration window is the “Save” button that has the function to save the modified parameters in the configuration of device. Always press this button otherwise the changes will be lost. The device has a default IP-address, if the device must be plugged into an existing network, configure at first the IP address from the menu section NETWORK SETUP. Configuration access To access the configuration you must change the IP address of the PC. Follow the instructions at the bottom of the following manual Troubleshooting section. Open your browser (Internet Explorer, Firefox, etc. ..) and go at http://10.0.0.100/index.html Please enter the correct Username and Password for administrator access and press Login button. It’s possible to modify the Username and Password in the configuration of the device. The menu, to access all the configuration pages, is available on the left side of the interface and has the following structure: Status: Page summary of the status of the device. Network Setup: Serial COM Setup: Modbus Setup: User Management: LAN settings. RS485 (COM1) settings (baudrate, databits, parity, timeout). Modbus protocol used for communication. User settings (Device Name, Username, Password).. Restore Default: Reboot: Log out: Restart the device with the factory settings. Restart the device with the current configuration. To exit properly at the end of each session. Status - Actual status of EMI-10L configuration. EMI-10L user manual IM471-U v0.2 pag. 2 Network Setup - LAN properties. DHCP: Select the operating mode of the DHCP Server. IP-address: IP address associated to the device. Netmask: Subnetmask of the device. Gateway IP-address: IP address of the gateway associated to the device. Port Number(1-65534): TCP port number for Modbus communication. Serial COM Setup - Configuration about serial port parameters. N.B. : These settings apply only to the COM1 serial. Baudrate: Transmission speed of the serial port. Data bits: Select 8 Data bits / 7 Data bits. Parity: Select None Parity / Parity Even / Odd Parity. Serial Timeout[msec]: Select serial COM1 timeout. Modbus Setup - Set the protocol used for Modbus communication. Modbus Protocol: Communication protocol used. Modbus TCP-IP or Modbus RTU (Serial-Over-IP). User management – Set some general informations. Device Name: Enter the name you want to assign to the mnemonic device. Username: Enter the new name. Password: Enter the new password. It always advisable to change the password of the device as the default password is public domain. EMI-10L user manual IM471-U v0.2 pag. 3 Connections For a correct use of the instrument to respect scrupulously the wiring diagram contained in this manual. Connections are available on screw terminals and RJ45 connector for connection to Ethernet network. ON link set data service ethernet ETHERNET MULTIFUNCTION INTERFACE 2x RS485 serial port power supply Vaux Aux1 Aux2 serial ports RS485 COM1 COM2 A1 B1 gnd A2 B2 LEGEND 1,3 terminals for connecting the auxiliary power supply 5,6 communication with the RS485 serial port COM1 8,9 communication with the RS485 serial port COM2 (COM2 not used) 7 ground RS485 serial port 10 Green LED for ON indication device access 12 Red LED indication receiving valid packet (LINK) 13 Push-button under the cover of the instrument (set): (within the first 10 seconds from power on) Restore factory condition 14 Yellow LED indication for data transmission (DATA) 15-18 Module RJ45 ethernet 100 base-T EMI-10L user manual IM471-U v0.2 pag. 4 Serial line connection For correct connection of the serials lines refer to the following schemes: link set data service ON ethernet ETHERNET MULTIFUNCTION INTERFACE 2x RS485 serial port power supply Vaux Aux1 Aux2 serial ports RS485 COM1 COM2 A1 B1 gnd A2 B2 Instrument’s network Gnd B A COM2: not used. Technical features GENERAL auxiliary power supply ethernet RS485 serial port display, operators mechanic enviromental standards EMI-10L Version: Vac 220 - 240 +- 15% Vac 100 - 130 +- 15% Version: 24V ac/dc consumption max 4VA RJ45 jack and 10/100BaseT magnetics, TCP/IP protocol standard, baudrate da 4800 a 19200 bps 3 LEDs (1 green: ON, 1 red: LINK, 1 yellow: DATA) button programming protection degree: IP52 frontal - IP20 enclosure and terminals - weight: about 0,4 kg connection with screw terminals for cable max 2,5 mm2 enclosure thermoplastic self-extinguishing – DIN rail mounting, 3 modules of 17,5mm working temperature: -10÷60°C; humidity <90% storing temperature: -25÷70°C insulation test: 3 kV for 1 minute CEI EN 50081-2 CEI EN 50082-1 CEI EN 61010-1 user manual IM471-U v0.2 pag. 5 Troubleshooting To use Ethernet communication with the EMI-10L, configure the IP address of your computer. Procedure: To change the IP address of a Windows XP computer, do the following: Click Start > Connect To > Show All Connections Choose your Local Area Connection Click Properties Choose Internet Protocol (TCP/IP) and click Properties Write down the existing address of your PC before changing it: • Choose Use the Following IP Address • Change the IP Address to 10.0.0.2 • Change the Subnet Mask to 255.0.0.0 • Click OK EMI-10L user manual IM471-U v0.2 pag. 6 EMI-10L user manual IM471-U v0.2 pag. 7 EMI-10L user manual IM471-U v0.2 pag. 8
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising