Pressure transducers DMU 01 Standard version Flush mounted diaphragm Application For electronic pressure measurement in industrial applications (such as hydraulic and pneumatic applications as well as machine and plant construction). Description The DMU 01 pressure transducers use proven ceramic measurement cell technology and feature calibrated, amplified sensor signals which are available as standardised voltage or current outputs. DMU 01 features: • High temperature resistance • No mechanical ageing • No transmission liquid Accuracy of measurement Deviation characteristics according to IEC 60770 - limit point setting (non-linearity, hysteresis, repeatability): < ±0,5 % FSO Measuring ranges Relative pressure: -1/0 to 0/400 bar Absolute pressure: 0/1 to 0/400 bar Overpressure safety < 250 bar min. 2 x FS > 250 bar min. 1.5 x FS (burst pressure min. 3 x FS) 416 Division II Operating temperature range Medium: -25 °C/+125 °C Ambient: -25 °C/ +85 °C Storage: -40 °C/+100 °C Temperature error band In compensated range < ±0.3 % FSO/10 K Dynamic characteristics Response time < 10 ms Process connection G1/2B (EN 837-1/7.3) or G1/2B DIN 3852 with flush mounted diaphragm (up to 0/25 bar max.) DMU 01 with DA 06 plug-in local display Current input 4-20 mA < 25 mA 0-10 V < 7 mA Protective electrical measures Short circuit proof and polarity protected Electrical connection (protection) Plug and junction box DIN 43650-A (IP 65) CE conformity (EMC) EN 61326 Options Materials Housing: Pressureconnection: Diaphragm: Seal: stainless steel 1.4305 stainless steel 1.4305 ceramic AI203 96 % FKM (Viton), NBR for 100 bar and above • • • • Other connection threads Fixed cable connection Other plug-in connectors Fitting of diaphragm seals (measuring range > 0/10 bar) Output signal/supply voltage 4-20 mA DC 12-36 V 2-wire 0-10 V DC 14-36 V 3-wire Load 4-20 mA < UB (V) – 12 V [Ohm] 0.02 A 0-10 V > 10 kOhm Refer to pages 420/421 for part no. Pressure transducers DMU 01 Dimensions (in mm) and electrical connections Connection G1/2B EN 837 Connection G1/4B EN 837 ap. 36 Connection G1/2B DIN 3852 with flush mounted diaphragm ap. 36 ap. 36 Flat gasket FKM (Viton) Detail A ap. 191,5 With diaphragm seal MD 30 - connection G1/2B ap. 195 ap. 143 With diaphragm seal MD 80 - flange connection EN 1092-1 MD 80 e.g. DN 25/PN 40 MD 30 e.g. PN 250 Wiring diagrams Pin assignment table 4-20 mA 2-wire Supply + 2-wire system: Supply - Supply (4-20 mA) Supply + – Earth 3-wire system: Supply (0-10 V) Supply 0-10 V 3-wire Supply + Signal Earth + – + Plug Cable colours DIN 43650 (DIN 47100) 1 white 2 brown Earth pin Screen 1 white 2 brown 3 green Earth pin Screen Supply Signal + The units are shipped with a detailed wiring diagram. Division II 417 Pressure transducers DG: H Type DMU 01 K* DMU 01 DMU 01 VM DMU 03 DMU 03 VM Version Measuring principle Accuracy (IEC 60770) Wetted parts Connection Supply voltage Output System Electrical Connection Measuring range Price € -1/0 bar -1/+1.5 bar -1/+3 bar -1/+5 bar Price € 0/40 mbar 0/60 mbar 0/100 mbar 0/160 mbar 0/250 mbar 0/400 mbar 0/600 mbar Price € 0/1 bar 0/1.6 bar 0/2.5 bar 0/4 bar 0/6 bar 0/10 bar 0/16 bar 0/25 bar 0/40 bar 0/60 bar 0/100 bar Price € 0/160 bar 0/250 bar 0/400 bar 0/600 bar Piezo-resistive ceramic measuring cell 1 % FSO 0.5 % FSO 0.5 % FSO (< 0.4 bar 0.5 % FSO) Ceramic/stainless steel 1.4305 G1/2B G1/2B DIN 3852 G1/4B DIN 3852 EN 837 with flush mounted diaphragm DC 12-36 V DC 12-36 V DC 12-36 V 4-20 mA 4-20 mA 4-20 mA 2-wire 2-wire 2-wire Plug Plug Plug DIN 43650-A DIN 43650-A DIN 43650-A (< 0.4 bar 0.5 % FSO) Stainless steel 1.4571/1.4435 G1/2B G1/2B EN 837 with flush mounted diaphragm DC 12-36 V DC 12-36 V 4-20 mA 4-20 mA 2-wire 2-wire Plug Plug DIN 43650-A DIN 43650-A Part no. Part no. Part no. Part no. Part no. --31608 31609 31610 31114 31616 31617 31618 31619 31620 31621 31622 31634 31635 31636 31637 --------- --------------- --------------- --------------- 32024 32025 31638 31639 31145 31146 31147 ----31643 31644 31165 31166 31167 --31511 31512 31513 31514 31515 31516 31517 31518 31611 31612 31115 31116 31117 31118 31119 31120 31121 31122 31123 31124 31125 31623 31624 31625 31626 31627 31628 31629 31630 ------- 31148 31149 31150 31151 31152 31153 31154 31155 31156 31157 31158 31168 31169 31170 31171 31172 31173 31174 31175 32026 ----- --------- 31126 31127 31128 --- --------- 31159 31160 31161 31162 --------- * Delivery only in packing units of 10 pieces per measuring range. 420 Division II Piezo-resistive stainless steel meas. cell 0.35 % FSO 0.35 % FSO Additional costs for pressure transducers DG: H Type DMU 01 DMU 01 VM DMU 03 DMU 03 VM Price € Price € no add. cost standard Version Price € Price € Ex protection II 1 G EEx ia IIC T4 --- --- Connection G1/4 DIN 3852 --- --- Connection G1/2 DIN 3852 --- standard --- Connection G1/4 B EN 837 --- --- Connection 1/4 NPT --- --- Connection 1/2 NPT Other connections --on request on request Suitable for oxygen Weatherpr. housing (stainl. steel 1.4305) --- --- Weatherproof housing with display (as DA 06) --- --- „Binder“ plug 723 --- --- --- --- on request on request Accuracy of measurement 0.25 % FSO --- --- Calibration certificate (for accuracy of measurement 0.25 % FSO) --- --- --on request on request --- --- on request on request Fixed cable connection 2 metres Cable extension per metre Output 0-20 mA, 3 wires Output 0-10 V, 3 wires Other output signals Absolute pressure (measuring ranges according to data sheet) Fitting of diaphragm seal for measuring range 0/10 bar All measuring ranges, minimum range depends on design of diaphragm seal Refer to chapter 14 for digital display units and signal processing. Division II 421
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising