Pressure transducers DMU 01 Standard version

Pressure transducers DMU 01 Standard version
Pressure transducers DMU 01
Standard version
Flush mounted diaphragm
Application
For electronic pressure measurement in industrial applications
(such as hydraulic and pneumatic
applications as well as machine and
plant construction).
Description
The DMU 01 pressure transducers
use proven ceramic measurement
cell technology and feature calibrated, amplified sensor signals which
are available as standardised voltage or current outputs.
DMU 01 features:
• High temperature resistance
• No mechanical ageing
• No transmission liquid
Accuracy of measurement
Deviation characteristics according
to IEC 60770 - limit point setting
(non-linearity, hysteresis, repeatability): < ±0,5 % FSO
Measuring ranges
Relative pressure: -1/0 to 0/400 bar
Absolute pressure: 0/1 to 0/400 bar
Overpressure safety
< 250 bar min. 2 x FS
> 250 bar min. 1.5 x FS
(burst pressure min. 3 x FS)
416 Division II
Operating temperature range
Medium:
-25 °C/+125 °C
Ambient:
-25 °C/ +85 °C
Storage:
-40 °C/+100 °C
Temperature error band
In compensated range
< ±0.3 % FSO/10 K
Dynamic characteristics
Response time < 10 ms
Process connection
G1/2B (EN 837-1/7.3) or
G1/2B DIN 3852 with flush mounted
diaphragm (up to 0/25 bar max.)
DMU 01 with DA 06 plug-in
local display
Current input
4-20 mA
< 25 mA
0-10 V
< 7 mA
Protective electrical measures
Short circuit proof and polarity
protected
Electrical connection (protection)
Plug and junction box
DIN 43650-A (IP 65)
CE conformity (EMC)
EN 61326
Options
Materials
Housing:
Pressureconnection:
Diaphragm:
Seal:
stainless steel 1.4305
stainless steel 1.4305
ceramic AI203 96 %
FKM (Viton), NBR for
100 bar and above
•
•
•
•
Other connection threads
Fixed cable connection
Other plug-in connectors
Fitting of diaphragm seals
(measuring range > 0/10 bar)
Output signal/supply voltage
4-20 mA
DC 12-36 V
2-wire
0-10 V
DC 14-36 V
3-wire
Load
4-20 mA < UB (V) – 12 V [Ohm]
0.02 A
0-10 V
> 10 kOhm
Refer to pages 420/421 for part no.
Pressure transducers DMU 01
Dimensions (in mm) and electrical connections
Connection G1/2B
EN 837
Connection G1/4B
EN 837
ap. 36
Connection G1/2B DIN 3852 with flush mounted
diaphragm
ap. 36
ap. 36
Flat gasket FKM
(Viton)
Detail A
ap. 191,5
With diaphragm seal MD 30 - connection G1/2B
ap. 195
ap. 143
With diaphragm seal MD 80 - flange connection
EN 1092-1
MD 80
e.g. DN 25/PN 40
MD 30
e.g. PN 250
Wiring diagrams
Pin assignment table
4-20 mA
2-wire
Supply +
2-wire system:
Supply -
Supply
(4-20 mA) Supply
+
–
Earth
3-wire system:
Supply
(0-10 V) Supply
0-10 V
3-wire
Supply +
Signal
Earth
+
–
+
Plug
Cable colours
DIN 43650
(DIN 47100)
1
white
2
brown
Earth pin
Screen
1
white
2
brown
3
green
Earth pin
Screen
Supply Signal +
The units are shipped with a detailed wiring diagram.
Division II 417
Pressure transducers
DG: H
Type
DMU 01 K*
DMU 01
DMU 01 VM
DMU 03
DMU 03 VM
Version
Measuring principle
Accuracy
(IEC 60770)
Wetted parts
Connection
Supply voltage
Output
System
Electrical
Connection
Measuring range
Price €
-1/0 bar
-1/+1.5 bar
-1/+3 bar
-1/+5 bar
Price €
0/40 mbar
0/60 mbar
0/100 mbar
0/160 mbar
0/250 mbar
0/400 mbar
0/600 mbar
Price €
0/1 bar
0/1.6 bar
0/2.5 bar
0/4 bar
0/6 bar
0/10 bar
0/16 bar
0/25 bar
0/40 bar
0/60 bar
0/100 bar
Price €
0/160 bar
0/250 bar
0/400 bar
0/600 bar
Piezo-resistive ceramic measuring cell
1 % FSO
0.5 % FSO
0.5 % FSO
(< 0.4 bar 0.5 % FSO)
Ceramic/stainless steel 1.4305
G1/2B
G1/2B DIN 3852
G1/4B
DIN 3852
EN 837
with flush mounted diaphragm
DC 12-36 V
DC 12-36 V
DC 12-36 V
4-20 mA
4-20 mA
4-20 mA
2-wire
2-wire
2-wire
Plug
Plug
Plug
DIN 43650-A
DIN 43650-A
DIN 43650-A
(< 0.4 bar 0.5 % FSO)
Stainless steel 1.4571/1.4435
G1/2B
G1/2B
EN 837
with flush mounted diaphragm
DC 12-36 V
DC 12-36 V
4-20 mA
4-20 mA
2-wire
2-wire
Plug
Plug
DIN 43650-A
DIN 43650-A
Part no.
Part no.
Part no.
Part no.
Part no.
--31608
31609
31610
31114
31616
31617
31618
31619
31620
31621
31622
31634
31635
31636
31637
---------
---------------
---------------
---------------
32024
32025
31638
31639
31145
31146
31147
----31643
31644
31165
31166
31167
--31511
31512
31513
31514
31515
31516
31517
31518
31611
31612
31115
31116
31117
31118
31119
31120
31121
31122
31123
31124
31125
31623
31624
31625
31626
31627
31628
31629
31630
-------
31148
31149
31150
31151
31152
31153
31154
31155
31156
31157
31158
31168
31169
31170
31171
31172
31173
31174
31175
32026
-----
---------
31126
31127
31128
---
---------
31159
31160
31161
31162
---------
* Delivery only in packing units of 10 pieces per measuring range.
420 Division II
Piezo-resistive stainless steel meas. cell
0.35 % FSO
0.35 % FSO
Additional costs for pressure transducers
DG: H
Type
DMU 01
DMU 01 VM
DMU 03
DMU 03 VM
Price €
Price €
no add. cost
standard
Version
Price €
Price €
Ex protection II 1 G EEx ia IIC T4
---
---
Connection G1/4 DIN 3852
---
---
Connection G1/2 DIN 3852
---
standard
---
Connection G1/4 B EN 837
---
---
Connection 1/4 NPT
---
---
Connection 1/2 NPT
Other connections
--on request
on request
Suitable for oxygen
Weatherpr. housing (stainl. steel 1.4305)
---
---
Weatherproof housing with
display (as DA 06)
---
---
„Binder“ plug 723
---
---
---
---
on request
on request
Accuracy of measurement 0.25 % FSO
---
---
Calibration certificate (for accuracy
of measurement 0.25 % FSO)
---
---
--on request
on request
---
---
on request
on request
Fixed cable connection 2 metres
Cable extension
per metre
Output 0-20 mA, 3 wires
Output 0-10 V, 3 wires
Other output signals
Absolute pressure (measuring ranges
according to data sheet)
Fitting of diaphragm seal
for measuring range 0/10 bar
All measuring ranges, minimum range
depends on design of diaphragm seal
Refer to chapter 14 for
digital display units and signal
processing.
Division II 421
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project