ACT - Source Security
Card Access Systems
Simple to install user friendly door access controllers and card
readers with optional PC software for system administration.
Superb features include Access Control, Time & Attendance, Door
Alarm Monitoring, Remote Site Dial Up, and Fire Alarm Override.
When performance counts ACT Card Access Systems
ACT: Totally committed to customer satisfaction
Features
Card Access
Systems
Product Overview
The ACT1000 single door controller offers the ideal
upgrade path from the ACT standalone product range.
For systems above one door choose the ACT2000 or
ACT3000 door controllers. To extend the controllers from
two up to sixteen doors install the DS100 single door
expander. For larger systems up to one thousand doors
simply network the ACT 2000 or ACT3000 controllers to
a PC. ACT door controllers are compatible with the full
range of ACT card readers and most third party readers.
Choose from the ACTWinPro and Pro Lite PC applications
to exploit the full potential of hardware controllers.
Applications
Access Control: Prevent unauthorised access to areas by
staff visitors or strangers. Provide secure and speedy
access to secured areas for authorised personnel.
Record all card and door transactions by time and date
in the powerful ACTWinPro database. Add and delete
cardholders in seconds. Control and administrate
remote sites via ACTWinPro software.
Time & Attendance: Install entry and exit readers on
perimeter doors and record staff time and attendance.
Export information to industry standard pay roll
software packages.
Door Alarm Monitoring, Building Evacuation and Door
Control: Monitor the status of all doors and alert staff
or security personnel of any unauthorised access. In the
event of fire automatically release all doors and provide
a roll call of all staff and visitors. Provide fast and
effective door control from a single point.
ACT2000 direct connect to PC
ACT1000
Feature
Doors
Cardholders
Log Events
User Groups
Time zones
Timed Actions
Printer Facility
Interlock
Roll Call
Multi client
Full admin audit trail
Anti-Pass back
Timed anti-passback
Holiday Scheduler
Entry Exit Facility
Fire Alarm Override
Pin & Card
Flash upgradeable
Built in TCP/IP
ACT1000
1
10,000
500
16
1
Y
Y
Y
NA
NA
ACT2000
2 to 16 *
20,000
5,000
32
32
Y
Y
Y
NA
NA
ACT3000
2 to 16 *
30,000
5,000
1000
256
Y
Y
Y
NA
NA
N
N
Y
Y
Y
Y
N
N
Y
N
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
Y
ACTWin Pro ACTWin Pro Lite
64
1000
30,000
30,000
Infinite
Infinite
Infinite
Infinite
Infinite
Infinite
Y
Y
Y
Y
NA
NA
Y
Y
Y
N
Y (5)
N
NA
NA
NA
NA
Y
Y
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
*The DS100 is a single door expander for the ACT2000/3000 controllers (max 14 per controller).
Controller Electrical & Mechanical Specification
Operating Voltage (DC)
Current Consumption
Weight
Operating Temperature
Dimensions (WxHxD in mm) *
ACT1000 ACT2000/3000
10 - 14.5 volts 10 - 14.5 volts
40 - 150 mA 120 to 230 mA
200 to 420 mA
0.75 kilos
.7 kilos
-100 to 500C
-100 to 500C
87x138x37
270x190x60
DS100
10 - 14.5 volts
40 to 120 mA
0.414 kilos
-100 to 500C
110x190x60
* These units must be installed indoors or in a weather sealed and heated outdoor housing
Card Reader Electrical & Mechanical Specification
Operating Voltage (DC)
Current Consumption
Weight
Dimensions (WxHxD in mm)
Surface
Flush
Indoor/Outdoor
ACT1010
5 - 12 volts
20 mA
0.5 kilos
ACTPro1030
5 - 12 volts
40 mA
0.2 kilos
ACTPro*
5 - 12 volts
40 mA
0.2 kilos
44x138x37
36x108x13
Y
Y
100x110x35
100x110x20
Y
*ACTPro including 1040/50/60
1
Cabling Specification
2
16 Doors Max
3
4
5
Note: For systems above 16 doors, install ACT PC Interface. 1000 Doors Max
From
ACT1000/2000/3000
ACT1000/2000/DS100
To
PC (Direct connect)
Card Readers
ACT2000/3000
ACT1000/2000
PC Interface
ACT1000/2000/DS100
DS100 (last)
PC Interface
PC
Lock, Push Button etc
Max Cable Run
30m
30m at 5 volts
100m at 12 volts
1.4km
1.4km
10m
Cable
Twisted Screen Pair
8 Core Screened
Twisted Screen Pair
Twisted Screen Pair
Twisted Screen Pair
Standard Alarm Cable
■ When networking Controllers to the interface or the DS100 to the ACT2000 the maximum distance
to the last unit is 1.4km. The units must be daisy chained and not star wired.
■ Category 5 or Belden cable maybe used
PC Specification: ACTWin software requires Windows 9X or Windows NT - XP.
ACT Cards and Fobs
ACT WinPro
ACT Pro 1050/1060
ACT Pro 1040 ACT Pro 1030
Unit C1, South City Business Park, Tallaght, Dublin 24.
Telephone: 353 1 466 2570. Telefax: 353 1 452 0427.
E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie