IPS (1x8kVA) UPS-D (1x10kVA)
 230 V AC OUT GOING SUPPLY TO TEXT DISPLAY
2 x 4mm MINIMUM - IF REQUIRED
230 V AC SUPPLY
2 x 10mm + E MINIMUM
UPS INDIVIDUAL ALARM CONDITIONS
TO BMS PANEL 5 x 0.5mm SCREENED
OR
UPS COMMON ALARM TO BMS PANEL
2 x 0.5mm SCREENED
230V AC UPS INPUT SUPPLY
2 x 10mm + E MINIMUM
230V AC UPS OUTPUT SUPPLY
2 x 10mm + E MINIMUM
UPS INDIVIDUAL ALARM CONTACTS
5x 0.5mm SCREENED
COPYRIGHT
This drawing is copyright and may not be altered, reproduced
or used other than for the Contract Works for which it is
issued without the written permission of STARKSTROM LTD. Any
design information, production selection, recommendation
and/or drawing provided by STARKSTROM LTD is given without
liability or responsibility in any event other than for
incorporation into an order for STARKSTROM LTD to execute the
work referred to.
STATUS OF DRAWING
The purpose of this drawing when issued as a sales Drawing is
to enable customers to interpret correctly the design and to
submit competitive tenders for the works. A Tender Drawing
whether original or amended shall not be used as an
Installation Drawing except under the terms contamed in the
conditions of Tender
WARNING
Do not scale this drawing. Verify all dimensions and structural
details on site. If in doubt, ask before acting
Any drawings submitted with quotations are subject to
confirmation/ change following production of engineering
drawings.
RELATED DOCUMENTS
Read this drawing in conjunction with the appropriate
Specification(s)
CHECKING
This drawing has been generated using a Computer Aided
Draughting system. As the system generates a new drawing at
each revision, only the latest edition will have been initialled as
checked.
Rev Date Designed | Drawn CAD Checked
Status /Amendments
A e . .
Initial sales information
BATTERY CABLE UPS INDIVIDUAL ALARM CONDITIONS TO IPS PANEL
SUPPLIED BY STARKSTROM 5 x 0.5mm SCREENED
3 x 10mm + E MINIMUM
MAX LENGTH SUPPLIED: 2m 230 V AC INCOMING SUPPLY
2 x 10mm + E MINIMUM
& REMOTE ALARM UNIT
RA004 4 x 0.5mm SCREENED
OR RA007 5 x 0.5mm SCREENED
J
o ETHERNET (RJ45)
o IPS COMMON ALARM TO BMS
MAINTENANCE
BYPASS PANEL 230 V AC OUT-GOING FEED TO FINAL SOCKETS
(CHANGE-OVER) 2 x 6mm +E MINIMUM (EACH)
(L1 BROWN - L2 BROWN)
— |
©
©
TO IPS/UPS TEXT DISPLAY ALARM UNIT (RA003) OR FROM 'OTHER' IPS
SYSTEM
[А] WITH FAN DAISY-CHAIN 2 x 0.22MM (BELDEN 9841) - MAX 200m - IF REQUIRED
8KVA
16 WAY WITH EDS IF CASTELL OR NO-BREAK TYPE BYPASS PANEL REQUIRED SELECTED
DIMENSIONS ARE AS FOLLOWS:
WEIGHT: 120kg
| HEAT LOSS:
0% LOAD - 50w Castell Type Panel Dimensions (mm)
BATTERY © 100% LOAD - 270W
CABINET o W H D
WEIGHT: 555kg x
AUTONOMY | 760 760 300
60 MINUTES
@ 10kVA U PS No-Break Panel Dimensions (mm)
o BATTERIES TO
N EN60896 КУА W H D
CABLE ENTRY: 600 600 21 0
BOTTOM REAR WEIGHT: 40kg o
CABLE ENTRY: ©
BOTTOM REAR
< = da A < 4 A A 4 q A <
7 < 4 4 4 q q 4 a < а“ a q 4 -
q <q A A q A <q A a A < А A A < 4 A
a° 4 q < 4 4 € 4 q q a a q a q
A 4 4 a < A a 4 a = 4 «8 < 4 A л а
4 A à q 4, 4 I А 7 A < 4, < 5 A a 4
<! a a 4 a a I < 5 q А I A < В AT 3 < 4 4 4
q a a a < 4 4 q 4 4 a < В a
a“ 4 7 Ca a 44 a - q < a 4 A < а © a 4 q <
©
3 EMB 2 we
BATTERY N o
со
CABINET ©
| cont]
Tw etl}
UPS
795
590
NOTES:
Battery cabinet maintenance access required from 2 sides
(eg. front and 1 side)
UPS maintenance access required from rear
(UPS unit on wheels)
PLAN VIEW
E STARKSTRON
256 Field End Road,
rastcote, Ruislip,
Middlesex HA4 SUW
United Kingdom
Tel:+44(0)20 8868 3732
Fax:+44(0)20 8868 3736
Project Title
TYPICAL CONFIGURATION
Drawing Title
1 No 8kVA IPS
1 No 10kVA UPS (1/1)
BATTERIES: CABINET, 60 MINUTES
Angle Scale: — 1:20
Projection
Thrd Units:— mms
Angle
Projection
Project No. Drawing No. Rev.
| Sheet Size: AS
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising