Press SET key for more than 3 seconds
can enter/quit the parameter setting
Specifications
Panel
Pulse signal: square wave and
Input signals sine wave :5≤H≤30V
0≤L≤2V up edge active
FH Series of Counter/Length/Batch
← ① Measured
Input impedance ≥10KΩ
Range:0.00001-99999
Counting speed 30/5000CPS
OUT1
value
Meter Instruction Manual
← ② Preset
SET
<</Rst
∧
∧
③ Indication lamps:
OUT1/OUT2: Output indication lamp
BT: Batch display lamp
SV2: The second preset value lamp
④ Keys:
SET: Select/Confirm key
<< /Rst:Shift/Reset key
∧
∧ :Up key
:Down key
The instrument can be used as counter, length-meter also
4, 6 digit LED display
Preset value is available
4 kinds ofinput mode and 6 kinds of output mode for option
Input and output is optical isolated
Power fail protection for at least 10 years
Widely applied in chemical, machine, light industry etc.
OUT2
250V AC/3A
0~50℃
or 30V DC/5A
35~85%RH
10 years
≥10MΩ
Consumption:<5W
Up edge Active
Mounting
Input :
default:2 ,D:other
-
Auxiliary power:
A: 12V DC
B: 24V DC
Communication:
Default: None
2: RS232
4: RS485
AL2 N: None
R:RELAY S: SSR/LOGIC T: SCR
AL1 N: None
R: RELAY S: SSR/LOGIC T: SCR
Function selection:
L:Frequency/Line-Speed/Tachometer
C: Counter/Length
4: 4 digit
Display:
6: 6 digit
Power Supply:
Default: AC 80-265V
E: 24V DC
4:48H×48W
Relay contact output
7:72H×72W
Size:
8:48H×96W
FH Series of Counter/
Length/Batch Meter
30
←
C
A
←
B
Sizes
Model
A
L
←
←
D
25
B
L
C
D
FH4
48
48
80
45+0.5
FH7
72
72
100
67,5+0.5 67,5+0.5
FH8
48
96
80
45+0.5
45+0.5
Batch preset
91+0.5
Operation process
★ Counting preset value setting: In displaying
estate, press <</RST key to shift,press ∧
∧
key to modify the value, and then press SET key
to confirm BT /SV2 converting display, press SET
key to view the parameters one by one.
∧
∧
FH
max
Power supply DC 24V ±15% or 80-265V AC/DC
Ordering code
←
1.
2.
3.
4.
5.
6.
7.
Contact edge
40mA
←
Features
Output type
Contact relay
capacity
Operation
environment
Parameter
saving time
Insulation
resistance
24V/12VDC ± 10%
←
Keep the instrument in the environment -10C to 70C,
Avoid sunlight for long time.
(According to the display digit)
0.00001-999999
Preset
range
Second preset:
This instrument should be installed to avoid the strong
noise sources. If the signal cable is too long,
we suggest you to use shielded cables.
Please don’t install the signal cable with the
power supply.
Avoid using this instrument in environment of
overflow water or explosive oil.
← ④
Auxiliary power
! Caution
Avoid using this instrument in environment of strong
shock or concussion.
← ③
SV2
(According to the display digit)
-199999-999999
←
Please do not turn on the power supply until all of the
wiring is completed. Otherwise electrical shock, fire
or malfunction may result.
Do not wire when the power is on. Do not connect the
unused terminals. Do not turn on the power supply when
cleaning this instrument. Do not disassemble, repair or
modify the instrument.
This may cause electrical shock, fire or malfunction.
Use this instrument in the scope of its specifications.
Otherwise fire or malfunction may result.
OUT1 OUT2 BT
∧
∧
Warning
Counting
range:
value
∧
∧
Thanks a lot for selecting MYPIN products!
Before operating this instrument, please
carefully read this manual and fully
understand its contents. If have problems,
please contact our sales or distributors
whom you buy from. This manual is subject
to change without prior notice.
1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising