Measurement and Documentation:
Thies’ range of service for meteorology,
environmental protection and industry
Today more than ever, the
measurement, processing and
analysis of meteorological
data requires a high degree of
measurement instrument precision and an optimal adaption
of the data acquired to the task
at hand.
For more than 50 years, we
have been developing, producing and supplying practical
instruments and systems for
the analysis of weather data.
Today we are one of the
world’s largest suppliers of
such equipment.
Our close cooperation with
scientific institutions and
governmental agencies in
many countries guarantees a
constant and up-to-date flow of
information about all aspects
of individual national problems
and projects and the rapid
implementation of state-ofthe-art developments and
measurement techniques.
Our instruments and systems
fulfill in all respects both to
the requirements of national
weather services as well
as those of the World
Meteorological Organization
in Geneva.
Meteorological observations
without computer-aided
measurement and documentation systems are unthinkable
today.
THIES develops complete
ready-for-use-systems which
include precision data transmitters, data loggers, power
supply units and personal
computers with adapted
software.
Humidity, Temperature, Pressure
Table of Contents
Humidity
Glossary . . . . . . . .
Indicators . . . . . . . .
Psychrometers . . . . .
Tensio-Transmitters . .
Recording Instruments
Control Instruments . .
Electrical Transmitters
Leaf Wetness . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
4
5
6
7
8
9
10
Glossary . . . . . . . .
Thermometers . . . . .
Recording Instruments
Electrical Transmitters
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
14
16
17
Glossary . . . . . . . .
Aneroid Barometers .
Mercury Barometers .
Recording Instruments
Electrical Transmitters
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
21
22
22
23
24
Humidity Temperature Pressure, combined
Indicators . . . . . . . . . . . .
Recording Instruments . . . .
Electronic Hand Instruments
Electrical Transmitter . . . . .
Clima Sensors . . . . . . . . .
Clima Sensors D . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
26
27
30
31
33
34
Weather and Thermal Radiation Shield
Weather Huts . . . . . . . . . . . . . . .
Measuring Transformers . . . . . . . . .
Digital Indicators . . . . . . . . . . . . .
Hangers/ Holders / Adapters . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
36
36
37
37
39
Temperature
Pressure
Accessories
1
Beyond the meteorology the
measurement and regulation of air
humidity is an essential element of the
climatic technology. Humidity control in
closed rooms as for example swimming
baths, offices or living-rooms creates a
comfortable atmosphere for man and
helps considerably to save energy. The
right humidity determines also the ideal
climate for delicate goods in storerooms
and dehumidifying plants, and improves
by this the product quality and durability.
In the rural meteorology and
environmental technique humidity
measurements in the open field are
undeniable for the planning of irrigation
and humidifying, for the determination
of the optimum seed and planting as
well as for the control of micro climate.
2
Humidity
Glossary
Absolute Humidity
Indicates the amount of water vapor present in the atmosphere, defined in the
number of grams of water per m3 of air.
Capacitive
measurement element
An arrangement in which a change in the relative humidity leads to a change in
the electrical capacity. For example the capacity of a polymer film on a carrier
material changes when water vapor is absorbed.
Dew point
A measure of the absolute humidity of the atmosphere. The temperature at
which the saturation point is reached under cooling i.e. dew begins to form
Dry bulb temperature
The ambient temperature measured on the dry ventilated thermometer of a
psychrometer.
Humidity hose
Fabric hose which is drawn over the thermometer of a psychrometer.
The hose is moistened and is used to measure the wet bulb temperature.
Hygro-Transmitter
General term for humidity measurement instruments with an electrical
measured value output.
Hygrograph
Measurement instrument which mechanically records the relative humidity
as a function of time.
Hygrometer
General term for humidity measurement instruments.
Hygrostat
Humidity-dependent switching instrument to regulate moistening or dehydrating
devices or to trigger warning signals indicating too little or too much moisture in
moisture-sensitive installations.
Measurement element H
Specially prepared human hairs expand under the influence of humidity, thus
changing in length. This change in length is a measure of relative humidity. The
range of application lies between 10 and 100% rel. humidity in temperatures
ranging from -60 to +70 °C. Hair measurement elements must be regenerated.
Measurement element K
Under the influence of humidity, specially prepared synthetic fibers change in
length. This change in length is a measure of relative humidity. The range of
application lies between 0 and 100 % rel. humidity in temperatures ranging from
0 to +100 °C.
Psychrometer
A measurement instrument with which the humidity of the atmosphere can be
measured by measuring the dry bulb temperature and the wet bulb temperature
and applying the psychrometric equation. Owing to the good measurement accuracy attainable, it is also used as a reference instrument.
Pt 100 ResistanceThermometer
The temperature-dependent change in resistance of a measurement coil made
of platinum wire is used as a measure of temperature.100  for 0 °C is usually
used as the basic value ( Pt 100). The standarized resistance values as a
function of time are found in IEC 751.
Relative Humidity
The ratio of the absolute humidity to the amount of saturation of the water vapor
in the atmosphere at the current temperature, expressed in percentage.
Tensiometer
Measurement instrument to measure the saturation potential of the soil
(water requirement of soils). Important to determine irrigation requirements.
Wet bulb temperature
(humidity temperature)
Wet bulb temperature, measured at the moisturized thermometer of a
psychrometer.
The wet bulb temperature results from the chilling because of the evaporation
at the moisturized thermometer.
3
Humidity
Description
Order No.
Technical Data
1.0070.xx.000
1.0074.xx.000
Model
Indicators
Round Hygrometer
Indicating instrument to
measure the ambient humidity.
Different models available.
.00.
.02.
Meas. element
H
K
Scale range
Accuracy
Graduation
Scale
Ambient temp.
Dimension
Weight
In-Stream type
Hygrometer
Round hygrometer with the
measuring element in an
immersion shaft attached
axially to the back of the case.
The instrument is designed
to be fastened horizontally
to a wall. The shaft protrudes
through a bore hole into a
neighbouring room
1.0153.xx.000
1.0154.xx.000
.00.
.02.
Immersion depth
Meas. element
H
K
Scale range
Accuracy
Graduation
Scale
Ambient temp.
Flange
Stem
Mounting thread
Weight
Wind Protection Device
Consists of a protective gauze
and a wind shield. Is put onto
the shaft of the in-stream type
hygrometer and protects the
measuring element from coarse
dust and error measurements
in case of wind velocities
>3 m/s.
4
1.0509.85.001
.002
Console
Case with flange
Measuring range
10 ... 100% rel. h.
0 ... 100% rel. h
0 ... 100% rel. h.
±3% rel. h.
@ 20 ... 100% r. h.
and room temperature
1% rel. h.
Ø 100 mm
-60 ... +70 °C (H)
0 ... +70 °C (K)
Ø 103 x 35 mm
Ø 120 x 36 mm with
model with mounting
flange
0.25 kg
100 mm
250 mm
Measuring range
10 ... 100% rel. h.
0 ... 100% rel. h.
0 ... 100% rel. h.
±3% rel. h.
@ 20 ... 100% r. h.
and room temperature
1% rel. h.
Ø 100 mm
-60 ... +70 °C (H)
0 ... +70 °C (K)
Ø 120 mm
Ø 16 mm
R 1/2“
approx. 0.45 kg
Immersion depth
100 mm
250 mm
Mesh aperture
Material
Diameter
Total length
Weight
0.32 mm for Gaze
stainless steel
18 mm
200 mm
0.022 kg
Humidity
Description
Order No.
Technical Data
1.0400.00.010
Measuring range
Accuracy
Graduation
Aspirator
Measuring time
Psychrometer
Aspiration Psychrometer
Model Assmann
Portable, handy, sturdy
standard instrument for
psychrometric humidity
measurements. Used as a
control instrument for humidity measuring instruments.
The thermometers acc. to DIN
58661 can be calibrated. The
thermometer capillary has a
blue background and a clearly
printed scale. The instrument
is equipped with a moistening
device and a psychrometertable. Supplied in a case.
Dimension
Weight
-10 ... +60 °C
±0.2 K (thermometer)
0.2 °C
spring-wound drive
approx. 8 min
(4 ... 2 m/s)
Ø 90 x 420 mm
3.5 kg
ReplacementThermometer
502888
Standard Psychrometer
1.0444.10.002
Type of thermometer
Psychrometer
Max.-Thermometer
Min.-Thermometer
Graduation
Total height
Weight
Measuring range
-30 ... +50 °C ( ±0.2 K)
-30 ... +50 °C ( ±0.2 K)
-40 ... +40 °C ( ±0.3 K)
0.2 °C / 0.5 °C
550 mm
2.6 kg
Sling Psychrometer
1.0450.00.010
Measuring range
Accuracy
Graduation
Dimension
Weight
-10 ... +60 °C
±0.2 K
0.2 °C
305 x 60 x 22 mm
0.42 kg
Instrument Case
1.0452.10.000
Colour
Dimension
Weight
black
350 x 230 x 70 mm
0.25 kg
ReplacementThermometer
502591
for Aspiration-Psychrometer
1.0400.00.010
Model August
Standard instrument for use in
weather huts and thermometer
huts. The instrument consists
of the following:
2 Psychrometric thermometers
acc. to DIN 58660
1 Maximum thermometer
acc. to DIN 58654
1 Minimum thermometer
acc. to DIN 58653
1 Aspirator with spring-wound
drive
1 Psychrometer table
1 Moistening device as well as
a foot with stand and holder.
Simple, sturdy measuring
instrument. The air ventilation
required is attained by rotary
centrifugal movement. The
instrument is supplied with
the required moistening device
along with a psychrometric
table.
Black synthetic material case,
lined with foam material for
the above instrument including
accessories.
for Sling-Psychrometer
1.0450.00.010
5
Humidity
Description
Order No.
Technical Data
1.0226.51.073
Measuring range
Electr. output
Non-linearity
Response time
Ambient temp.
Operating voltage
Tube length
Protection
Cable
Weight
Tensio Transmitters
Tensio Transmitter
Electrical instrument for the
continuous measurement of
the saturation potential of the
soil which results from the
pressure balance between
tensiometer liquid and the
ambient soil by means of a
diaphragm (ceramic cell). A
pressure sensor measures the
pressure of the water tension
in the soil.
6
0 ... -85 kPa
0 ... 5 V DC
< 0.5%/K
<3s
0 ... +40 °C
12 ... 24 V DC / 0.5 VA
600 mm
IP 65
5 m long
0.45 kg
Humidity
Description
Order No.
Technical Data
Recording Instruments
Hygrograph
Instrument for measurement
and recording of the relative
humidity. Measurement results
are recorded on a strip chart,
which is situated on a drum
clockwork with manual winding
mechanism acc. to DIN 8300
and DIN 58658 or a Quartz
clockwork. Two models are
available regarding the drum
clockwork:
1.0610.xx.xxx
1.0614.xx.xxx
1.0615.xx.xxx
.10.
.12.
.000
.900
1. With mechanical drum clockwork and manual winding
mechanism for the temperature range from -35 … +80 °C
for model (1.0610/614…).
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
Meas. range
10 ... 100% rel.h.
0 ... 100% rel.h.
non lockable
lockable
Scale range
Accuracy
Recording width
Graduation
Ambient temp.
2. With Quartz clockwork and
1,5 V battery operated,
Quartz controlled stepmotor-drum clockwork in
the temperature range form
-20 … +60 °C (the model
1.0615…).
Dimension
Weight
Thrust
11.45 mm/h,
40 mm/day
20 mm/day,
9 mm/day
s. above
Measuring element
H (-35 ... +70 °C)
K (0 ... +80 °C)
0 ... 100% rel. h.
±2% rel. h. (H)
±3% rel. h. (K)
@ 65% rel. h. and
room temperature
82 mm
5% rel. h.
-35 ... +80 °C (springwound clockwork)
-20 ... +60 °C
(quartz clockwork)
280 x 140 x 214 mm
2.2 kg
Delivery including 1 set strip
charts (100 sheets)
Accessories
Felt Pen
Recording Charts
500847
502722
502721
(100 pcs.)
205079
205077
205082
205083
205080
205078
Console
1.0598.10.000
To attach the hygrograph
to a wall.
Colour
violet (standard)
black
red
Meas. element
H
H
H
H
K
K
Recording
1 day
7 days
14 days
31 days
1 day
7 days
Material
Surface
Weight
Varnished aluminium
280 x 140 mm
0.8 kg
7
Humidity
Description
Order No.
Technical Data
1.0509.xx.000
.40.
.42.
Meas. element
H
K
Control range
Switch difference
Contact
Contact load
30 ... 90% rel. h.
±3% rel. h.
1 change over
250 V AC / 15 A
24 V DC / 2 A
130 x 65 x 33 mm
0.22 kg
Control Instruments
Room Hygrostat
Moisture control instrument for
humidifier and dehumidifier.
The desired value can be set
by means of a rotary knob.
Dimension
Weight
Hygrostat
(for use in ducts)
Moisture control instrument for
humidifier and dehumidifier.
The instrument is mounted
to the wall of a duct. The
immersion stem protrudes
through this wall into the
measuring space. The model
with 2 switches is equipped
with an adjustable switch
differential of 5 ... 25% rel. h.
Type of contact
Control range
Switch difference
Measuring element
Stem
Stem length
Contact load
Dimension
Weight
1 change over
30 ... 90% rel. h.
±3% rel. h.
K
Ø 16 mm
270 mm
max. 250 V AC
max.10 A
max. 1000 VA
134 x 67 x 70 mm
0.6 kg
Mounting Flange
1.0509.80.000
Material
Weight
Al, Brass
0.1 kg
Wind Protection
1.0509.85.002
Diameter
Length
Mesh aperture
Material
Weight
18 mm
200 mm
0.32 mm
Niro, Brass
0.022 kg
To mount duct hygrostats
1.0509.60 / 70.
The flange clamps the hygrostat
to the stem and allows a
variable immersion depth.
(not depicted)
A device to protect the
humidity measuring element
from coarse dust (> 0.32 mm)
and error measurements in
case of wind velocities > 3 m/s.
Suitable for above duct
hygrostat.
8
1.0509.60.000
Humidity
Description
Order No.
Technical Data
1.1000.50.xxx
.015
.515
Electr. output
200  linear
200  linear
Connecting
Lemosa plug
3 m cable
Measuring range
Accuracy
Ambient temp.
Scale graduation
Measuring element
Scale length
Stem
Stem length
Protection
Total length
Weight
10 ... 100% rel. h.
±2% rel. h.
@ 20 ... 100% rel. h.
and room temperature
-35 ... +70 °C
1% rel. h., non-linear
H
94 mm (90°)
Ø 22 mm
250 mm
IP 65, case
350 mm
0.45 kg
Electrical Transmitters
Hygro-Transmitter
Measures and indicates
humidity. Equipped with
electrical output for longrange transmission. Sturdy
construction. The exposed
parts such as the case head
and the immersion stem are
made of stainless steel.
Wind Protection
1.0509.85.006
Diameter
Length
Mesh aperture
Material
Weight
24 mm
200 mm
0.32 mm
Niro, Brass
0.022 kg
Weather and Thermal
Radiation Shield
1.1025.51.000
Installation pin
Material
Ø 22 x 27 mm
Al, galvanised and
varnished
Ø 170 x 450 mm
2.5 kg
Gauze- and wind protection protects the humidity
measuring element from
coarse dust (> 0.32 mm) and
error measurements in case
of wind velocities > 3 m/s.
Suitable for above hygro
transmitter.
Protective covering for the
preceding hygro-transmitters
out-of-doors. Helps to prevent
atmospheric influences and
radiation errors from influencing the measured results.
Psychro-Transmitters
Measuring instrument to
determine the air humidity
values based on the dry and
moist temperature. An attached
water container provides for
the moistening of the psychro
sensor.
The double-walled protection
tubes protect the sensor from
radiation.
Replacement-Sensor
for Psychro-Transmitter 1.1130…
compl., consisting of Pt 1000
(1/3 class B) casing and plug
connection
Dimension
Weight
1.1130.xx.000
.20.
.22.
Operating voltage
Operating voltage
Measuring range
Measuring elements
Accuracy
Time constant
Air stream
Water container
Electr. connection
Connection
Dimension
Weight
12 V AC / 6 VA
24 V AC / 11 VA
24 V DC / 8 W
12 V DC
0 ... +60 °C
2 x Pt 100,
acc to. IEC 751
1/3 class B (±0.1 k)
17 s (90%)
4 ... 6 m/s
250 ml
4-lead circuit
4 pole plug
Ø 160 x 465 mm
3.7 kg
2.1266.10.001
9
Humidity
Description
Order No.
Technical Data
1.0225.00.xxx
.000
Meas. element
Hemp
Leaf Wetness
Leaf Wetness Transmitter
Model Dr. Weihofen Instrument
to be connected to the THIESdatalogger.
The leaf wet ness is determined
by means of the electrical
conductivity of natural
substances. The wetness
period is shown as leading
value with the information
”dry” or ”wet”. Each instrument has its separate scaling
parameter, which is already
integrated in the software program of the THIES-dataloggers.
.001
Cotton
Measuring range
Resolution
Leaf wetness
Application
Potatoes, Rapes,
Trees
Grain
Cable 20-m
Dimension
Weight
0 ... 100%
10%-points
< 20% “dry”
> 80% “wet”
LiYCY 2 x 0,5 mm2
100 x 50 x 50 mm
0.7 kg
Electrical input
Electrical output
Ambient temp.
Operating voltage
Protection
Cable 3 m
Dimension
Weight
Resistor
0 - 5 V (0 ... 100%)
-30 ... +50 °C
6 - 18 V DC
IP 65
LiYCY 3 x 0,25 mm2
58 x 35 x 64 mm
0.18 kg
Suitably for this:
Preamplifer
The instrument serves to convert the small measuring value
signals of the Leaf Wetness
Transmitter into a standardized
signal, which can be transmitted also over a long distance
afterwards.
10
1.1415.00.100
Your Notice
11
Temperature measurements are
fundamentally important in the
different fields of science, industry
and environmental technique.
The legal requirements e.g. for the
storing of food, get constantly stricter,
and meanwhile lay down also official
controls of climatic data.
Our instruments with calibration certificate meet these requirements. Reliable
measurements and documentation
of extreme temperature ranges and
temperature fluctuations as well as highprecise measurements are problem-free
possible with the different instrument
components. Exactly acquired and
recorded temperature values form the
basis for effective energy optimising
and energy saving.
Meteorological garden with weather huts
Meteorological data for
the road condition
Climatic measurement of the South Pole
12
Temperature
Glossary
Bimetallic
A strip composed of two different metals which are welded together.
The two different
Measurement
heat expansion coefficients of these metals lead to a temperature-dependent
curvature
Element
of the welded metal. This curvature respectively deflection is a measure of the
temperature.
Extreme Thermometer
Combination of a min.- and a max. thermometer to measure the current, the lowest
and the highest temperature of the preceding measurement period.
Max.-Thermometer
Mercury thermometer to measure the current temperature and the highest
temperature of the preceding measurement period. When the temperature drops,
the highest temperature reached is indicated by a mark.
Min.-Thermometer
Alcohol thermometer to measure the current temperature and the lowest temperature of the preceding measurement period. A dark pin in the alcohol thread is
pushed back by the surface tension of the alcohol and remains stationary when
the temperature increases. The thermometer is used in a horizontal position.
Perceived Temperature
The ambient temperature as perceived by the human body by the wind and
calculated from the windchill factor.
Pt 100 Resistance
Thermometer
The temperature-dependent change in resistance of a measurement coil made of
platinum is used as a measure of temperature. 100  for 0 °C is usually taken as
the basic value ( Pt 100). The standardized resistance values as a function of time
are found in IEC 751.
Soil Thermometer
Measurement instrument to measure the air temperature in soil at different
depths.
Soil Surface Thermometer
Measurement instrument to measure the temperature above the soil, preferably
at a height of 5 cm. The German Weather Service uses sensors without radiation
protection only to measure the minimum temperature.
Temperature Transmitter
Electrical temperature measurement instrument with an electrical measured
value output.
Thermograph
Measurement instrument which mechanically records the temperature
as a function of time.
Thermometer
General term for a temperature measurement instrument.
Windchill
The loss of heat by the human body [W/m2] through the wind.
The “perceived temperature” is derived from this factor.
Units
Kelvin [K]
Used since 1976 as the legal unit of temperature.
It starts at -273.15 °C
Celsius [°C]
Common temperature degree scale in which the melting
point of ice is 0°C and the boiling point of water is 100 °C
on a thermometer at an air pressure of 1013.2 mbar.
Fahrenheit [°F]
Temperature scale frequently used in Anglo-Saxon countries.
On this scale, the melting point of ice is 32 °F
Conversions
°C = K -273.15 K
K = °C +273.15 °C
5
°C = – (°F -32)
9
9
°F = 32 + – °C
5
13
Temperature
Description
Order No.
Technical Data
Maximum Thermometer
2.0445.00.002
Measuring range
Accuracy
Graduation
Type
Dimension
Weight
-30 ... +50 °C
±0.2 K
0.5 °C
acc. with DIN 58654
Ø 19 x 300 mm
0.075 kg
Minimum Thermometer
2.0446.00.001
Measuring range
Accuracy
Graduation
Type
Dimension
Weight
-40 ... +40 °C
±0.3 K
0.5 K
acc. with DIN 58653
Ø 19 x 300 mm
0.06 kg
Standard Thermometer
2.0447.00.001
.002
Measuring range
Accuracy
Graduation
Model
Dimension
Weight
-40 ... +40 °C
-30 ... +50 °C
±0.2 K
0.2 °C
acc. with DIN 58660
Ø 16 x 370 mm
0.06 kg
Meas. range
-25 ... +60 °C
-25 ... +60 °C
-25 ... +45 °C
-22 ... +40 °C
-15 ... +40 °C
-15 ... +35 °C
-15 ... +35 °C
Immersion depth
20 mm
30 mm
60 mm
110 mm
160 mm
210 mm
310 mm
Accuracy
±0.4 K (< 0 °C)
±0.2 K (0 ... 50 °C)
±0.3 K (> +50 °C)
0,2 °C
acc. with DIN 58655
150°
ca. 0.95 kg
Thermometers
A mercury glass thermometer,
can be calibrated. Employed
to determine the highest air
temperature.
An alcohol glass thermometer,
can be calibrated. Employed
to determine the lowest air
temperature.
A mercury glass thermometer,
can be calibrated. Designed for
measuring the current ambient
temperature.
Also used as a spare thermometer for psychrometers model
August.
Soil Thermometer
A mercury glass thermometer,
can be calibrated. Designed
for measuring the soil
temperature. Supplied with
a holder. The immersion
depth governs the depth of
the measuring point in the soil.
2.2110.02.003
.03.003
.06.004
.11.006
.16.008
.21.009
.31.009
Graduation
Type
Bending
Weight
Soil Depth Thermometer
Consists of a mercury glass
thermometer with a holder
and a plastic guide tube.
The immersion depth governs
the depth of the measuring
point in the soil.
14
2.2115.03.013
2.2116.03.013
Immersion depth
Measuring range
Accuracy
Graduation
Type
Guide tube
Weight
500 mm
1000 mm
-10 ... +30 °C
±0.3 K (-10 ... -5 °C)
±0.15 K (-5 ... -30 °C)
0.1 °C
acc. with DIN 58664
Ø 40 mm
0.9 kg resp. 1.4 kg
Temperature
Description
Order No.
Technical Data
Extreme Thermometer
for use in Soil
2.2121.xx.002
2.2122.xx.002
.02.
.05.
.10.
.20.
Type
Consists of a mercury glass
thermometer with a bent
immersion stem, determines
the lowest and highest
temperature of the soil.
The immersion depth governs
the depth of the measuring
point in the soil.
Immersion length
Min.-Thermometer
Max.-Thermometer
20 mm
50 mm
100 mm
200 mm
Measuring range
Accuracy
Graduation
Bending
Weight
-25 ... +50 °C
±0.4 K / ±0.3 K
0.2 °C
95°
0.12 kg
Thermometer Stand
2.2123.00.000
Material
Dimension
Weight
Stainless steel
340 x 320 x 20 mm
0.7 kg
Extreme Thermometer
2.2135.00.000
Techn. data
see instrument no.:
2.0445.00.002 and
2.0446.00.001
(page 14)
320 mm
1.5 kg
not depicted
Holds the extreme thermometer
for use in soil, described in the
preceding.
Determines the lowest and
highest ambient temperature.
Consists of a maximum
thermometer and a minimum
thermometer with stand.
Total height
Weight
■ other thermometer-variants, measuring range and scales on request
Max.- and Min.Thermometer
Model Six
Thermometer determines the
current temperature as well
as the lowest and the highest
temperatures of the measuring
period.
There is a magnet included
in the delivery to set back the
markers for extreme value
identification.
Instrument is installed onto a
plane wall.
Max.- and Min.Thermometer
Thermometer determines the
current temperature as well
as the lowest and the highest
temperatures of the measuring
period.
There is an adjustment knob to
set back the marker threads for
extreme value identification.
2.2000.00.002
2.2002.00.002
2.2004.00.079
Model
Glass base plate
Sheet metal case
Measuring range
Graduation
Fluid
Instrument colour
Dimension
Weight
-30 ... +50 °C
1 °C
Mercury
white
200 x 55 x 10 mm,
resp.
240 x 60 x 35 mm
0.15 kg, resp. 0.2 kg
Measuring range
Graduation
Fluid
Material of case
Length of scale
Dimension
Weight
-38 ... +50 °C
1 °C
Mercury
white synthetic
110 mm
220 x 66 x 35 mm
0.17 kg
15
Temperature
Description
Order No.
Technical Data
Water Thermometer
2.2141.00.064
Measuring range
Accuray
Graduation
Fluid
Container
Dimension
Weight
-5 ... +40 °C
±0.2 K
0.5 °C
Mercury
Brass, nickel plated
Ø 28 x 300 mm
0.4 kg
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
non-lockable
lockable
Meas. range
-35 ... +45 °C
-20 ... +60 °C
-10 ... +50 °C
0 ... +40 °C
0 ... +80 °C
Thrust
11.45 mm/h,
40 mm/day
20 mm/day
9 mm/day
see preceding
Accuracy
Measuring element
Recording width
Dimension
Weight
±1% of mr.
Bimetal
82 mm
280 x 138 x 214 mm
2.2 kg
1.0598.10.000
Material
Surface
Weight
Aluminium, varnished
280 x 140 mm
0.8 kg
Felt Pen
500847
502722
502721
Colour
violet (standard
black
red
Recording Charts
temp. range
-35 ... +45 °C
-20 ... +60 °C
-10 ... +50 °C
0 ... +40 °C
0 ... +80 °C
1 day
205060
205050
205052
205054
205057
Thermometer determines the
water temperature.
A glass mercury thermometer
in a metal tube with a large
perforated water container.
Recording Instruments
Thermograph
Instrument for measurement
and recording of the ambient
temperature. Measurement
results are recorded on a strip
chart, which is situated on a
drum clockwork with manual
winding mechanism acc. to
DIN 8300 and DIN 58658 or a
Quartz clockwork. Two models
are available regarding the
drum clockwork:
2.0600.10.xxx
2.0604.10.xxx
2.0605.10.xxx
.0xx
.9xx
.x00
.x05
.x11
.x14
.x17
1. With mechanical drum
clockwork and manual
winding mechanism for
the temperature range from
-35 … +80 °C (for model
2.0600/604…).
2. With Quartz clockwork and
1,5 V battery operated,
Quartz controlled stepmotor-drum clockwork in
the temperature range form
-20 … +60 °C (the model
2.0605…).
Graduation
1 °C
1 °C
1 °C
0.5 °C
1 °C
Delivery including 1 set strip
charts (100 sheets)
Console
Instrument for wall mounting of
the thermograph described in
the preceding.
Accessories
(100 pcs.)
For Thermograph
16
7 days
205046
205036
205038
205040
205043
14 days
205063
205064
31 days
205069
205075
205068
205076
Temperature
Description
Order No.
Technical Data
2.1235.00.xxx
2.1235.01.xxx
.000
.010
.020
Measuring range
Electrical Transmitters
Temperature Transmitter
Water Temperature
Transmitter
The measuring element is
protected by a waterproof and
stainless steel tube, it has a
PVC cable resp. a Teflon cable.
Cable length
Measuring element
Accurary
Electr. connection
Cable
Sensor dimension
Weight
Soil Surface Temperature
Transmitter
2.1241.00.000
Instrument measures the
temperature above the surface
of the soil. The temperature
sensor is protected by a wellventilated double-walled tube
with roofing plate. The instrument is inserted into the soil.
Measuring range
Measuring element
Accuracy
Electr. connection
Cable
-30 ... +100 °C (±0.1 K)
-50 ... +200 °C (±0.1 K)
5m
10 m
20 m
Pt 100 acc. to IEC 751
1/3 class B
(0.1 °C at 0 °C)
4-lead circuit
LIYCY 4 x 0.25 mm2
Ø 6 x 70 mm
0.3 kg; 0.6 kg; 1.2 kg
Dimension
Weight
-30 ... +50 °C
Pt 100 acc. to IEC 751
±0.1 K; 1/3 class B
4-lead circuit
5 m, LiYCY
4 x 0.25 mm2
double tube,
varnished
Ø 177 x 100 mm
1 kg
Protective shield
Surface Resistance
Thermometer
2.1252.00.000
Measuring range
Measuring element
Accuracy
Dimension
Weight
-80 ... +180 °C
Pt 100 acc. to IEC 751
±0.5 K
50 x 21 x 0,2 mm
2g
Air Temperature
Transmitter with Thermal
Radiation Shield
2.1260.00.000
Measuring range
Measuring element
Accuracy
Electr. connection
Connection
Dimension
Weight
-30 ... +50 °C
Pt 100 acc. to IEC 751
±0.1 K; 1/3 class B
4-lead circuit
4-pole clamp
Ø 120 x 400 mm
0.8 kg
Ventilated Air
Temperature Transmitter
2.1265.xx.000
.20.
Operating voltage
Operating voltage
12 V AC/ 6 VA or
24 V AC/ 11 VA or
24 V DC/ 8 W
12 V DC/ 4 W
Measuring element
Accuracy
Ventilation
Electr. connection
Connection
Dimension
Weight
Pt 100 acc. to IEC 751
1/3 class B (±0.1 k)
6 m/s
4-lead circuit
plug
Ø 160 x 435 mm
3.5 kg
A foil temperature transmitter
to measure temperatures on
plane and curved surfaces.
The platinum measuring coil
is embedded between two
0.5 mm thick polyamide
(Kapton) foils.
The instrument is designed
to measure the temperature
out-of-doors precisely. It has
a specially constructed wellventilated thermal radiation
shield made of an anodized
aluminium.
This instrument is designed
to measure the precise air
temperature with the air of a
ventilated sensor. The sensor
is protected by a double
thermal radiation shield. A
built-in ventilator provides
for the necessary air flow.
Replacement-Sensor
for Ventilated Air Temperature
Transmitter 2.1265… compl.
consisting of PT 100 (1/3 Class
B), casing and plug connection
.22.
2.1266.10.001
17
Temperature
Description
Order No.
Technical Data
Temperature-Sensor
compact
2.1280.00.xxx
.000
.141
.161
Electr. output
Pt 100 ( IEC 751)
4 ... 20 mA
0 ... 10 V
Measuring range
Time constant
Ambient temp.
Operating voltage
I-output
U-output (10 V)
Int. power consump.
Cable
Dimension
Weight
Accuracy
±0.1 K; 1/3 class B
±0.3 K
±0.2 K
-30 ... +70 °C
20 s (90%)
-40 ... +80 °C
Clamping range
Wall distance
Ø 20 mm
83 mm
(to transmitter centre)
plastic, grey flange
plate with 3 x 6,5 mm
boring
96 mm long
0.075 kg
Electrical measured value
receiver to measure the ambient
temperature, The measured
value is emitted as a resistance
value in accordance with IEC
751 resp. as an analogue
voltage or current signal.
Teflon Filter
1.1005.54.901
Sinter Filter ZE 21
1.1005.54.902
Support for wall
mounting
1.1005.54.903
with gauze (not depicted)
This hood is placed over
the sensor and protects the
measurement element from
coarse dirt.
made of metal (not depicted)
This basket is placed over
the sensor and protects the
measurement element from
high wind speed (> 5 m/s)
and increased dust.
A necessity for sensors in
use in exposed areas, eg.
in marine climates, desert,
mountains.
Not depicted
- for mounting the Temperature
Sensor 2.1280 onto a wall,
- radiation- and precipitationprotected use ( for ex. indoor)
Weather and Radiation
Protection Case,
compact
Protective case for the
preceding temperature sensor
compact for installation outof-doors. This case essentially
eliminates the influence of
weather and radiation errors
which affect the measurement
result.
18
Material
Mounting
Dimension
Weight
1.1025.55.00x
.10x
.xx0
.xx1
Without ventilator
With ventilator
Clamping
Material
Mounting
Cable
Dimension
Weight
12 - 30 V DC
24 V DC ±10%
approx. 5 mA (10 V)
5 m long
Ø 20 x 138 mm
0.35 kg
12 V DC; 2.5 W
Ø 35 … 50 mm
Ø 55 … 60 mm
syn. laminations,
white
non-corroding holder
5 m, for model ...10x
Ø 120 x 270/290 mm
0.75 kg
Your Notice
19
The acquisition and recording of
air pressure differences and areas
of low and high pressure are the
main tasks of the meteorology for
precise weather forecasting. But
also in the field of laboratorial
and environmental technique the
exact determination of air pressure
is very important. The THIES
instruments configuration with
their varied forms of calculation
and representation guarantee
a high precision measurement
according to requirements.
20
Air Pressure
Glossary
Barometer
A Barometer is a measuring instrument for determination (display) of air
pressure, and is used in a variety of different forms and types mostly in the
field of meteorology.
Barograph
A Barograph is a measuring instrument which records the time course of the
air pressure on a chart-stringed drum.
Baro transmitter
A Baro transmitter is a measuring instrument with electrical measuring value
output
Air pressure (P)
The air pressure of any place in the earth’s atmosphere is the pressure of
the air, existing at this place. It indicates the weight power of the air column
standing above a surface or body.
QFF
QFF is the current air pressure at the measuring site (for ex. aerodrome/
airport), reduced to the sea level. It is used in the field of meteorology in
order to compare the air pressures of different places at different heights. The
calculation is carried out with ASL (altitude above sea level) and data of the
“current atmosphere” (pressure, temperature, and humidity).
QFE
QFE means the air pressure of aerodrome/airport on the runway. If QFE is set
at the altimeter (for ex. before start or landing) you achieve the barometric air
pressure or height related to the airport height. On the airport the altimeter
indicates then a height of 0 m or 0 ft.
QNH
The abbreviation QNH means the air pressure at the measuring station,
reduced to sea level acc. to “standard atmosphere”.
It serves for setting an altimeter which displays the flight altitude above sea
level. After landing of the aircraft, the altimeter displays the altitude of site
above sea level.
TA
Transition Altitude is a term used in aviation. It indicates the altitude where the
transition of the altimeter setting from standard air pressure to the currently
existing air pressure QNH is carried out or vice versa.
TL
Transition Level (TL) is the lowest flight level available for use which has a
minimum distance of 1000 ft above the transition altitude. Therefore the
Transition Level is depending on the air pressure. In some regions of Germany
the Transition Altitude is, generally, 5000 ft.
Standard atmosphere
Standard atmosphere is a term used in aviation. Characteristics like pressure,
temperature, or temperature course with the altitude are subject to special
and time changes in the atmosphere. The standard atmosphere indicates an
average state of the atmosphere.
Barometric Altitude Formula
Barometric Altitude Formula indicates the vertical change of the air pressure
with the altitude.
Simplify you may assume that close to the sea level the air pressure declines
by one hPa per 8 m altitude.
Barometric Unit
Unit of the air pressure is the Pascal.
As the air pressure on sea level is, on average, 101325 Pa, thus approx.
100000 Pa, it is given mostly by the number about 1000 in hectopascal
(1013.25 hPa) or by the same numerical value millibar (mbar). The air pressure
is mostly measured through a barometer, where often obsolete units are used.
Here is: 1 hPa = 1 mar = 0.75 Torr (= mm Hg or millimeter mercury column).
21
Pressure
Description
Order No.
Technical Data
3.1503.00.000
Measuring range
Aneroid Barometers
Barometer
Indicating instrument with an
inner frame of polished brass
and an outer frame of polished
brown wood.
Barometer
Indicating instrument with
a mounting flange for wall
mounting. Light grey varnished.
Graduation
Accuracy
Above sea level
Meas. element
Scale
Dimension
Weight
3.1509.00.000
Measuring range
Graduation
Accuracy
Above sea level
Meas. element
Scale
Dimension
Weight
Precision Barometer
A very accurate instrument.
Test certificate enclosed.
Supplied in a leather case.
3.1530.00.000
Measuring range
Graduation
Accuracy
Above sea level
Meas. element
Scale
Dimension
Weight
960 ... 1070 hPa
720 ... 800 Torr
1 hPa; 1 Torr
±3% of mr.
0 - 1000 m
Aneroid capsule
Ø 115 mm
Ø 180 x 45 mm
0.56 kg
935 ... 1065 hPa
700 ... 800 Torr
1 hPa; 1 Torr
±2 hPa at
980 - 1030 hPa
0 - 1000 m
Aneroid capsule
Ø 100 mm
Ø 120 x 45 mm
0.3 kg
920 ... 1050 hPa
-6 ... +46 °C
0.5 hPa; 1 °C
±1% of m.r.
0 - 500 m
Aneroid capsule
Temperature
compensated
Ø 115 mm
Ø 150 x 75 mm
0.72 kg
Mercury Barometers
Mercury
Station Barometer
An instrument designed to
measure and test atmospheric
air pressure in meteorological
stations, laboratories etc. The
instrument is equipped with an
additional thermometer.
3.1550.17.000
.001
Measuring range
800 ... 1080 hPa
560 ... 1030 hPa
Graduation
Accuracy
Temp. meas. range
Dimension
Weight
0.1 hPa, vernier scale
±0.3 hPa
-15 ... +50 °C
Ø 65 x 940 mm
4.8 kg
For meas. range
800 ... 1080 hPa
560 ... 1030 hPa
1000 x 115 x 13 mm
2 kg
Delivery in a wooden transport
box
Mounting Board
For vertical installation of the
mercury station barometer.
22
3.1552.00.000
.001
Dimension
Weight
Pressure
Description
Order No.
Technical Data
3.0800.10.xxx
Recording time
1 day
7 days
14 / 31 days
1 / 7 / 31 days
non lockable
lockable
Thrust
11.45 mm/h;
40 mm/d
20 resp. 9 mm/d
see preceding
Measuring range
Graduation
Accuracy
Above sea level
Meas. element
945 ... 1052 hPa
1 hPa
±0.8 hPa
0 ... 3000 m
Aneroid-capsules
temperature
compensated
-10 ... +45 °C
82 mm
280 x 138 x 214 mm
2.3 kg
Recording Instruments
Barograph
This instrument is used to
measure and record the
atmospheric air pressure.
The recording is carried out by
means of a hand wound clock
work drum mechanism acc.
to DIN 8300 and DIN 58658
(3.0800... ; 3.0804....) or with a
Quartz clock work (3.0815....).
The on-site elevation can be
set by means of an adjusting
screw.
Delivery includes a set of
recording charts (100 sheets ).
Micro Barograph
A precision measuring and
recording instrument to
determine the atmospheric
pressure. Elevation above the
sea level can be set at the
measuring site on a setting
knob. The recording is carried
out by means of a hand wound
clockwork drum mechanism
acc. to DIN 8300 and DIN
58658.
3.0804.10.xxx
3.0805.10.xxx
.000
.900
Ambient temp.
Recording width
Dimension
Weight
3.0810.20.000
Recording time
Thrust
Measuring range
Accuracy
Recording width
Graduation
Above sea level
Meas. element
Ambient temp.
Dimension
Weight
1 / 7 days, switchable
11.45 mm/h or
40 mm/d
965 ... 1050 hPa
±0.3 hPa
160 mm
1 hPa
0 ... 2000 m,
adjustable
2 Aneroid capsules,
temperature
compensated
-10 ... +45 °C
280 x 138 x 285 mm
3 kg
Accessories
Felt Pen
500847
502722
502721
Colour
violet (standard)
black
red
Recording Charts
205184
205182
205185
205186
Recording time
1 day
7 days
14 days
31 days
205187
205188
Recording time
7 days
1 day
(100 pcs.)
for Barograph 3.0800.10.xxx
Recording Charts
(100 pcs.)
for Micro Barograph
3.0810.20.000
23
Pressure
Description
Order No.
Technical Data
3.1150.10.015
Measuring range
Graduation
Accuracy
Electr. output
Above sea level
Meas. element
Electrical Transmitter
Baro Transmitter
An electrical transmitter which
indicates directly the measured
values of the atmospheric air
pressure. The measured value
is indicated and delivered as
electrical resistance value.
Ambient temp.
Case material
Cable
Dimension
Weight
Barotransmitter B-278-1T
Barotransmitter B-278-2T
Barotransmitters measure the
barometric ambient pressure
and emit the measured value
as an electrical voltage value.
Owing to its low current
consumption, It is particularly
suitable for use in combination
with data loggers.
To be mounted preferably in
data logger systems.
Digital Barotransmitter
Indicating meas. instrument
with analogue output to
determine the atmospheric
pressure. An aneroid capsule
with inductive displacement
pickup serves as a sensor. The
sensor signal is amplified
electronically and displayed
on a LC display. The analogue
output is available for the
connection of electronic
recording and control
instruments. Behind the
front panel is a potentiometer
to reduce the measured value
to sea level. The instrument
is in the form of a switch cabinet
for panel installation.
24
3.1158.00.075
3.1158.10.075
3.1159.00.xxx
.040
.041
Measuring range
946 ... 1053 hPa
1 hPa
±1.5% of mr.
0 ... 200 
max. 3000 m
Aneroid capsules
temperature
compensated
-20 ... +60 °C
Synthetic
1 m, LiYCY
5 x 0.5 mm2
122 x 120 x 85 mm
0.75 kg
800 ... 1060 hPa
600 ... 1060 hPa
B- 278-1T
Accuracy @ 20°C
Linearity
Hysteresis
±0.3 hPa
±0.25 hPa
±0.03 hPa
S- 278-2T
Accuracy @ 20°C
Linearity
Hysteresis
±0,5 hPa
±0,45 hPa
±0,05 hPa
Resolution
Long Term Stabilty
Electr. output
Operating voltage
Ambient temp.
Dimension
Weight
0.01 hPa
0.1 hPa / Yr
0 ... 5 V DC
9.5 - 28 VDC (3 mA)
-40 ... +60 °C
61 x 91 x 25 mm
0.14 kg
Electr. output
0 ... 20 mA
4 ... 20 mA
 250 
913.3 ... 1113.3 hPa
±0.5 hPa (at NN)
0.1 hPa
4 1/2-digit LED red
0 ... +50 °C
0 ... 850 m
230 V AC or 115 V AC
or 12 ... 28 V DC
panelmounting
96 x 96 x 127 mm
0.6 kg
Load
Measuring range
Accuracy
Resolution
Display
Temp. range
Above sea level
Operating voltage
Model
Dimension
Weight
Description
Order No.
Technical Data
Baro Display
3.1156.xx.000
.00
Operating voltage
230 V / 50Hz; 24 V AC
12 - 35 V DC
115 V / 50 Hz; 24 V AC
12 - 35 V DC
Measuring range
Accuracy
Resolution
800 ... 1100 hPa
±0.3 hPa
0.1 hPa
Displaying measuring instrument for four air pressure
parameters. Instrument with
integrated pressure sensor.
Analogue output and serial
interface serve for out of
measuring data to processing
systems.
Display parameter:
• P absolute pressure
• QNH air pressure relating to
the sea level with standard
atmosphere
• QFE air pressure related
to the runway
• TL Transition- Level
Input possibilities:
• Input of height (m, ft) at the
baro display related to the
sea level (QNH)
• Input of height (m, ft) at the
baro display related to the
runway (QFE)
• Input of the TransitionAltitude (Germany 5000 ft)
Output of measuring value:
• The output of the acquired
parameters is carried out
via a serial interface. The
interface specifications
are selectable at the barodisplay.
• The analogue output of
absolute pressure and
QNH is carried out via an
integrated analogue interface
(U/I is selectable)
.01
Digital interface
Type
Baud rate
Parameter
Analogue output
Display
Temperature range
ASL (Altitude above
sea level)
Construction
Dimension
Protection
Weight
EMC
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1
2 x 0 ... 10 V or
0 (4) ... 20 mA
4 x 5-digit, LED red,
14 mm high
-10 … 50 °C
selectable
switch panel mounting
144 x 144 x 135 mm
IP 23
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
25
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
1.0101.00.003
Measuring range
Temperature
Dew point
rel. humidity
Saturation deficit
Graduation
Humidity sensor
Instrument color
Dimension
Scale
(length x high)
Weight
Indicators
Polymeter
Combined indicating
instrument to measure the
ambient temperature and rel.
humidity and to determine
the dew point temperature,
saturation pressure, vapour
pressure or saturation deficit.
The values can be read directly
at the scale.
The temperature is measured
with a mercury thermometer.
Round HygroThermometer
Combined indicating
instrument designed to
measure the ambient
temperature and rel. humidity.
1.0165.00.006
1.0169.00.006
with feet and hook
with flange for wallmounting
Scale range
0 ... 100% rel. h.
-20 ... +40 °C
Measuring element
humidity
temperature
Graduation
Accuracy
Weight
Combined indicating
instrument designed to
measure the ambient
temperature and rel. humidity,
as well as the representation of
the normal climate acc. to DIN
50014, and of a comfort range
1.0165.42.058
1.0169.42.058
Model
Humidity
Measuring range
Graduation
Accuracy
Temperature
Measuring range
Graduation
Accuracy
Dimension
Weight
Hygro-Thermometer
A thermometer and a
hygrometer are fixed on
a joint base plate.
Instrument for wall mounting.
26
1.0170.00.xxx
.006
.017
Ø 84 mm
250 x 30 mm
0.2 kg
Model
Dimension
Hygro-Thermometer
-30 … +50 °C
-30 … + 25 °C
0 … 100% rel. h.
0.5 … 100 hPa
2% rel. h.; 1 K
Hair
anthracite
Measuring range
Graduation
Scale range
Accuracy
Scale
Model
Dimension
Weight
Hair
Bimetal
1% rel. h./ 1 °C
±3% rel. h.
@ 20 ... 100% rel. h.
and room temperature
±1 k
Ø 103 x 35 mm
Ø 120 x 36 mm with
model with mounting
flange
0.3 kg
with feet and hook
with flange for wallmounting
20 ... 100% rel. h.
2% rel. h.
±3% rel. h.
@ room temperature
+5 ... +45 °C
1 °C
±1 K
Ø 130 x 36 mm
Ø 150 x 36 mm with
model with mounting
flange
0.45 kg
-20 ... +40 °C
0 ... +80 °C
10 ... 100% rel. h.
1% rel. h. / 1 °C
0 ... 100% rel. h
±3% rel. h.
@ 20 ... 100% rel. h.
and room temperature
±1 k
Ø 100 mm
on a base plate
260 x 138 x 40 mm
1.1 kg
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Recording Instruments
Hygro-Thermograph
Recording instrument.
The housing consists of a
plastic-metal combination.
The axes are supported by
pivot bearings.
Two different models are
available regarding the drum
clockwork drive:
1. Mechanical drum clockwork
mechanism with hand
winding for the temperature
range between
-35 ... +80 °C.
2. Quartz clock work, batteryoperated 1,5 V Mignon
cell (LR6A) with switchable
thrusts in the temperature
range between -10 ... +60 °C
Delivery includes a set of
recording charts (100 pcs.).
1.0660.xx.xxx
1.0664.xx.xxx
1.0665.xx.xxx
.00.
.02.
.0xx
.9xx
.x00
.x05
.x11
.x12
.x14
.x15
.x16
.x17
Recording time
1 day
7 days
14 days
31 days
1, 7, 31 days
Hum. meas. elem.
H (-35 ... +70 °C)
K (0 ... +80 °C)
non lockable
lockable
Temp. meas. range
Thrust
11.45 mm/h
40 mm/d
20 mm/d
9 mm/d
Quartz clock work
Measuring range
10 ... 100% rel. h.
0 ... 100% rel. h.
Scale range
Accuracy
humidity
0 ... 100% rel. h.
temperature
pressure
Recording width
Graduation
Dimension
Weight
-35 ... +45 °C (only H)
-20 ... +60 °C (only H)
-10 ... +50 °C (only H)
-10 ... +40 °C (only H)
0 ... +40 °C
0 ... +50 °C
0 ... +60 °C
0 ... +80 °C
±2% rel. h. (H)
±3% rel. h. (K)
@ 65% rel. h. and
room temperature
±1% of the meas.
range
±0.8 hPa
2 x 82 mm
5% rel. h. / 1 resp.
0.5 °C
280 x 138 x 285 mm
2.7 kg
27
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Hygro-Thermograph
1.0680.10.xxx
.011
.014
Meas. range Hum.
Meas. range Temp.
10 ... 100% rel. h. (H)
-10 ... +50 °C
0 ... +40 °C
1.0680.12.014
Meas. range Hum.
Meas. range Temp.
0 ... 100% rel. h. (K)
0 ... +40 °C
Scale range
Accuracy
humidity
0 ... 100% rel. h.
Recording instrument with a
transparent plastic case. The
axes are supported by pivot
bearings.
Battery-operated 1,5 V Lady
cell (LR1) quartz step-motor
drum clockwork mechanism.
The recording time is
switchable.
Delivery includes a set of
recording charts (100 pcs.).
temperature
pressure
Recording time
Thrust
Recording width
Graduation
Dimension
Weight
±2% rel. h. (H)
±3% rel. h. (K)
@ 65% rel. h. and
room temperature
±1% of the meas.
range
±0.8 hPa
1/7/31 days
11.45 mm/h
40.01 resp.
9 mm/day
2 x 82 mm
5% rel. h. /
1 resp. 0.5 °C
280 x 138 x 270 mm
2.1 kg
Accessories
Recording Charts
Meas. element H
35 … +45 °C
-20 … +60 °C
-10 … +50 °C
0 … +40 °C
0 … +80 °C
Meas. element K
0 … +40 °C
0 … +80 °C
1 day
205142
205143
205138
205123
205126
1 day
205131
205134
Felt Pen
500.847
502.722
802.721
colour
violet (standard)
black
red
Console
1.0598.10.000
Material
Surface
Weight
Aluminium, varnished
280 x 140 mm
0.8 kg
(100 pcs)
For Hygro-Thermograph
Attention: Pay attention to
the measuring ranges !
For wall-mounting of the
hygro-thermographs, order no..
1.0660... to 1.0665...
28
7 days
205086
205088
205092
205094
205103
7 days
205097
205112
14 days
205153
205158
205155
205150
205280
14 days
205151
205282
31 days
205169
205168
205166
205160
205281
31 days
205161
205283
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Meteorograph
1.0840.00.xxx
.000
.005
Measuring range
A triple recording instrument
for the most important
meteorological data
temperature, rel. humidity,
and barometric air pressure.
Reliable, sturdy model with
spring-wound clockwork
mechanism.
White varnished metal case.
The axes are supported by
pivot bearings.
Delivery includes a set of
recording charts (100 pcs.).
humidity
pressure
Accuracy
humidity
temperature
pressure
Graduation
Recording time
Advance
Hum. meas.elem.
Recording width
Dimension
Weight
-35 ... +45 °C
-20 ... +60 °C
10 ... 100% rel. h.
945 ... 1052 hPa
±2% rel. h. @ 65% r.h.
and room temp.
±1% of the
meas. range
±0.8 hPa
5% rel. h. / 1 °C /
1 hPa
1 day / 7 days
11.45 mm/h;
40 mm/d
H
3 x 82 mm
280 x 140 x 350 mm
4.5 kg
Accessories
Felt Pen
500847
502722
502721
colour
violet (standard)
black
red
Recording Charts
temp. range
-35 … +45 °C
-20 … +60 °C
1 day
205197
205073
7 days
205192
205190
Electronic
Thermo-Hygrograph
1.8252.00.000
Measuring range
-20 ... +50 °C
10 ... 95% rel.h.
±0.3 °C (0 … 40 °C)
±0.5 °C for rest.
±3% rel. h.
0.1 °C
0.5% rel. h.
NTC
capacitiv
65 x 40 mm
RS 232
120.000 values/
channel
1; 5; 10; 60;
1440 min.
typ. 2 years
3.6 V lithium battery
115 x 110 x 25 mm
250 g
(100 pcs.)
For Meteorograph
Digital measurement and
display instrument for air
humidity and air temperature
with integrated sensors in
housing of synthetic material.
The measured data are
indicated and stored.
Delivery with reading-out
software: PC-Windows software,
interface cable, battery,
data memory for 120.000
measurement values/channel.
Accuracy
Resolution
Temp. Sensor
Humidity Sensor
Display
Interface
Memory capacity
Scanning interval
Operating time
Operating voltage
Dimension
Weight
29
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
1.8625.10.000
Measuring sensor
Temperature
Rel. humidity
Electronic Hand
Instruments
Hygro-Thermometer 625
Digital portable measuring
instrument with integrated
measuring sensor for the
measurement of rel. humidity
and temperature.
Measuring range
Accuracy
Display:
• Rel. humidity
• Wet bulb temperature
• Dew point temperature
• Temperature
• Max.- and min. values
Display
Resolution
Supply
The instrument is equipped with a “hold function”
for holding the displayed
measuring instrument.
Included in delivery: portable
measuring instrument,
pluggable sensor, battery,
and calibration protocol.
Operating time
of battery
Housing
Dimension
Weight
Accessories
Hand grip for
measuring sensor
1.8625.11.725
Carrying Case
1.8625.20.210
Topsafe (protective cover)
1.8625.20.221
DKD Certificate
1.8625.90.206
ISO Certificate
1.8625.90.006
Battery Charger
1.8625.30.025
9 V Accumulator
1.8625.30.515
Hand grip for pluggable humidity sensor head for connection
to hygro-thermometer 625
inclusive sensor cable.
For measuring instrument
and sensor
Protects against shock and dirt
11,3% and 75,3% r.h.
@ +25,0 °C
11,3% and 75,3% r.h.
@ +25,0 °C
For external charging
of the accumulators
30
NTC
capacitive
-10 ... +60 °C
0 ... 100% rel. h.
±0.5 K
±2.5% rel. h.
(5 ... 95% rel. h.)
LCD, approx. 14 mm
high, illuminated
0.1 °C / 0.1% rel. h.
9 V-block battery,
6F22
approx. 70 hours.
synthetic (ABS)
182 x 64 x 40 mm
195 g
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
1.1005.00.xxx
1.1015.00.xxx
.040
.041
.061
Model
Electrical Transmitter
Hygro-Thermo
Transmitter capacitive
Instrument designed for
measurement of temperature
and air humidity. The data are
output as electrical analogue
signals. The transmitters
consist of a capacitive
humidity element and a Pt 100
resistance thermometer.
Measuring range
humidity
temperature
Model for ducts
Accuracy
humidity
The measuring elements
are situated at the end of
the immersion stem which
protrudes from the back.
temperature
Measuring
element
Room Model
The measuring elements are
situated in a lateral protective
cover.
Hygro-Thermo Transmitter
Instrument designed for
measurement of temperature
and air humidity. The data are
output as electrical analogue
signals. Humidity value is
displayed additionally.
The transmitters consist of a
hair humidity element and a
Pt 100 resistance thermometer.
Sturdy construction, essential
external parts are made of
stainless steel. For mounting
out-of-doors we recommend
the use of the weather- and
thermal radiation shield
order no. 1.1025.51.000.
(see p. 36)
Electr. output
0 … 100% rel.h.
0 … +60 °C
< ±3% rel. h. in the
range 5 ... 95% rel.h.
±0.1 K + 0.05
Diameter of stem
Length of stem
Connecting
Dimension
Weight
Capacitive for humidity, Pt 100 at IEC 751
1/3 DIN class B for
temperature
linear
15 … 24 V AC
15 … 36 V DC
25 mm
250 mm
screw clamps
130 x 75 x 55 mm
0.2 kg
Electr. output
200  lin./ Pt 100
200  lin./ Pt 100
Electr. connection
with Lemosa-plug
with 3 m cable
Measuring range
Accuracy
10 ... 100% rel. h.
±3% rel. h.
@ 20 ... 100% r.h. and
room temperature
±1 k
1% rel. h. not linear
94 mm
H
Pt 100, acc. to IEC 751
1/3 class B
22 mm
250 mm
IP 65, display case
350 mm
0.7 kg resp. 0.9 kg
Characteristic
Operating voltage
1.1005.50.xxx
.015
.515
Model for ducts
Room model
2 x 0 ... 20 mA/0-10 V
2 x 4 ... 20 mA/0-10 V
2 x 0 … 10 V
Graduation
Scale length
Hum. meas. elem.
Temp. meas. elem.
Diameter of stem.
Length of stem
Protection
Total length
Weight
31
Humidity
Temperature
Pressure
1.1005.54.xxx 1.1005.54.241
Description
Order No.
Technical Data
Hygro-Thermo
Transmitter compact
1.1005.54.xxx
Electr. output
Humidity
0 ... 1 V
4 ... 20 mA
0 ... 10 V
Instrument designed for
measurement of temperature
and air humidity. The data are
output as electrical analogue
signals. The transmitters
consist of a capacitive
humidity element and a Pt 100
resistance thermometer.
For mounting out-of-doors we
recommend the use of the
weather- and thermal radiation
shield
order no.. 1.1025.55.xxx.
(see page 36)
.000
.241
.161
Measuring range
Accuracy
Temp. Meas. elem.
Operating voltage
Protection
Cable
Dimension
Weight
Protective basket
with gauze
1.1005.54.901
Protective basket
made of metal
1.1005.54.902
Wall holder
1.1005.54.903
Temperature
Pt 100 (±0,1 K)
4 ... 20 mA (±0,3 K)
0 ... 10 V (±0,2 K)
0 ... 100% rel. h.
-30 ... +70 °C
±2% rel. F.
Pt 100, acc. to
IEC 751 1/3 class B
9 ... 30 V DC (...000)
12 ... 30 V DC (...241)
24 V DC (...161)
IP 30 for sensor
IP 65 for electronic
5 m long
Ø 20 x 115 mm
0.45 kg
not depicted
Is put on the sensor and
protects the measuring element
from coarse dust.
not depicted
Is put on the sensor and
protects the measuring element
from high wind speeds
(> 5 m/s) and coarse dust.
Necessary for use in exposed
areas (e.g. sea climate).
not depicted
Serves for wall mounting of
hygro-thermo transmitter
1.1005.54…, for use protected
against radiation and
precipitation (for ex. indoor).
Weather and Thermal
Radiation Shield
Protective case for hygrothermo transmitter compact
with outdoor installation.
Clamping range
Wall distance
Material
Mounting
Dimensions
Weight
1.1025.55.00x
.10x
.xx0
.xx1
W/o Ventilator
with Ventilator
Clamping range
Material
Montage
cable
Dimensions
Weight
32
Ø 20 mm
83 mm
(to transmitter centre)
plastic, grey
flange plate with
3 x 6.5 mm boring
96 mm long
0.075 kg
12 V DC; 2.5 W
Ø 35 … 50 mm
Ø 55 … 60 mm
Synthetic lamellas,
white
Non-corroding holder
5 m, for model. ...100
Ø 120 x 270 /
290 mm
0.75 kg
Humidity, Temperature
Pressure, Wind
Brightness
Description
Order No.
Clima Sensors
Technical Data
Wind
Precipitation,
Brightness, Twilight
Temperature
Air humidity
X
X
X
X
X
X
Clima Sensor
WTF
4.9010.00.061
X
X
Clima Sensor
W
4.9000.00.061
X
X
Clima Sensor
TF
4.9011.00.061
X
Clima Sensor
4.9001.00.061
X
The Clima Sensor 2000 serves
for the measurement of
important environmental data.
Depending on the type of task
it is available as combined
measuring instrument.
The analogue outputs are
configured as standard signals
so that they can be used for
the coupling on customary bus
systems.
Wind Speed
Meas. range
Accuracy
Electr. output
Load resistor
1 … 40 m/s
 0.5 m/s
0 … 10 V (=0 ... 40 m/s)
 10 k
PrecipitationDetection
Meas. range
Electr... output
Sensitivity
Load resistor
Precipitation yes/no
0 V at precipitation
10 V no precipitation
Drizzle
 100 k
Sensitivity
Switch off-delay
Drizzle
approx. 2 min.
Meas. range
Spectral range
Accuracy
Electrical output
Load resistor
0 … 100 k Lux
700 … 1050 nm
±10% of meas. value
3 x 0 … 10 V,
Eastern, Southern
and Western Direction
 10 k
Twilight
Meas. range
Electr. output
Load resistor
0 … 250 Lux
0 … 10 V
 10 k
Temperature
Meas. range
Meas. element
Accuracy
Electr. output
Load resistor
-20 … +60 °C
Pt100 at IEC 751 1/3 DIN
±0.15 °C at 0 °C
0 … 10 V
 10 k
Humidity
Meas. range
Accuracy
0 … 100% rel. humidity
±3% in the range
10 … 90% rel. h.
0 … 10 V
 10 k
Wind
A cup star, the revolution-no.
of which is linear-proportional
to the wind speed, supplies
a frequency through a Reedcontact to a connected
frequency-voltage-converter.
Precipitation
The detection is carried out
optically acc. to the reflectionmethod with modulated
infrared-light on precipitation
particles.
Brightness
The brightness is detected by
means of three independent
photo-diodes which are arranged in 90°-segments. Three
independent output voltages
are linear to the brightness.
Twilight
The twilight is detected by
a photo diode. A converter
transforms the signal into an
output voltage, which is linear
to the twilight range.
Temperature
The temperature sensor is
a standardized resistance
thermometer - Pt 100 - of
longterm stability.
Air humidity
The measurement is carried
out with a capacitive humidity
sensor changing its capacity
according to the relative
humidity.
Brightness
Detection
Electrical output
Load resistor
General
24 V AC ±15%
24 V DC ±25%
Current load
 150 mA
Temperature range -40 °C … +60 °C
Connecting cable 10 m; LiYCY
12 x 0.14 mm2,
UV-resistant max.
100-m supply at with
nominal 24 V
Mounting
Niro-holder clamp
on mast or wall
Weight
max. 1.5 kg
class B
Operating voltage
33
Humidity, Temperature
Pressure, Wind
Brightness
Description
Order No.
Clima Sensors D
Technical Data
Wind
Precipitation,
Brightness, Twilight
Temperature
Air humidity
X
Clima Sensor D
WTF
4.9110.00.061
X
X
Clima Sensor D
W
4.9100.00.061
X
X
Clima Sensor D
TF
4.9111.00.061
X
Clima Sensor D
4.9101.00.061
X
The Clima Sensor D serves
for the measurement of
important environmental
data. Depending on the task,
it is available as combined
measuring instrument. Model
D is equipped in addition
with a DCF 7 radio controlled
clock, and an integrated serial
interface. An internal heating
serves as protection against
dew.
Wind
Measuring range
Accuracy
0,5 ... 40 m/s
±0,5 m/s or ±5% Mb
Precipitation
Measuring range
Sensitivity
Switch-off-delay.
Load resistance
rain yes / no
drizzle
approx. 2 minutes
 100 kW
Brightness
for East, South,
West
Measuring range
Spectral range
Accuracy
0 ... 100 k Lux
700 ... 1050 nm
±10% of measuring
value
The instrument has
• Analogue outputs and
• Serial interface
• DCF77-receiver for
date and time
• Dew protection
Twilight
Measuring range
0 ... 250 Lux
Temperature
Measuring range
Accuracy
-20 ... +60 °C
1/3 class B acc.
to IEC 751
±0.1 °C at 0 °C
The analogue outputs are standard signals and can be used
for the connection to commercially available bus systems.
Air humidity
Measuring range
Accuracy
0 ... 100% rel. humidity
±3 in the range
10 ... 90% rel. h.
Signal
0 ... 10 V each
parameter 0 V for rain,
10 V with dryness
Load resistance
 10 kW ( 100 kW
with precipitation)
Type
Output
RS 422/485
9600Bd, 8N1, simplex-,
half-duplex-operation
Instant. values,
date and time
1 / sec.
Further description see
Clima Sensor
Output
analogue
serial
Measuring values
Output rate
General
Operating voltage
Current
consumption
Ambient temp.
Connecting calbe
Mounting
Weight
34
X
24 V AC ±15%
24 V DC ±25%
 150 mA
(with heating  650 mA)
-40 °C ... +60 °C
10 m; LiYCY 16 x
0.14 mm2, uv-resistant
max. 100 m at supply
with nominal 24 V
non-corrosive holding
clamp for mast or wall
max. 1.5 kg
Your Notice
35
Accessories
Description
Order No.
Technical Data
1.1025.51.000
Suitable for
Weather and Thermal
Radiation Shield
Weather and Thermal
Radiation Shield
Protective covering for the
Hygro-Thermo- or HygroTransmitters out-of-doors.
Helps to prevent atmospheric
influences and radiation errors
from influencing the measured
results.
Weather and Thermal
Radiation Shield,
compact
Protective case for the
Temperature or Hygro-ThermoTransmitter compact for
installation out-of-doors. This
case essentially eliminates
the influence of weather and
radiation errors which affect
the measurement result.
Installation pin
Material
Dimension
Weight
1.1025.55.00x
.10x
.xx0
.xx1
Without ventilator
With ventilator
Clamping range
1.1000.50...
1.1005.50...
Ø 22 x 27 mm
aluminium galvanised
and varnished
Ø 170 x 450 mm
2.5 kg
12 V DC, 1.3 W
Ø 35 … 50 mm
Ø 55 … 60 mm
Mounting
Cable
Dimension
Weight
1.1005.54 ... or
2..1280....
synthetic lamellas
white
stainless steel holder
5 m for model. ...10x
Ø 120 x 270/290 mm
0.75 kg
in acc with DIN 58656
wood, painted white
two-leafed
1.80 m
0.7 m
720 x 450 x 470 mm
60 kg
Suitable for
Material
Weather Huts
Weather Hut
1.2170.00.000
Model
Material
Door
Height of hut
Height of stairs
Inner dimension
Weight
Weather Hut
1.2171.00.000
As above but without the stand and stairs.
Weather Hut
1.2175.00.000
Model Wild
Protective hut to hold
meteorological measurement
instruments. Protects them
from precipitation and
eliminates radiation errors.
Louvered walls guarantee
good air circulation. Delivery
includes a stand with three
stairs made of hot galvanized
steel.
Model Wild
(not depicted)
Small version of the preceding
huts, without stand and stairs.
36
Material
Door
Inner dimension
Weight
wood, painted white
one-leafed
350 x 230 x 410 mm
12.5 kg
Accessories
Description
Order No.
Technical Data
Measuring Transformers
Measuring Transducer FTD
humidity-temperature-pressure
The resistance signal from the
data transmitter is converted
into current and/or voltage
proportional to the measured
value. This makes it possible
to control subsequently
added recording or switching
instruments.
The measuring transducer is
usually connected to humidity
transmitters, temperature transmitters or baro transmitters.
The wall case is mounted to a
plane wall, whereas the PCboard is inserted into a 19“ rack.
1.1080.xx.xxx
1.1081.xx.xxx
2.1082.xx.xxx
3.1080.xx.xxx
.00.xxx
.10.xxx
.xx.040
.xx.041
.xx.060
.xx.061
Electr. input
0 - 200 , linear
0 - 200 , linear
Pt 100
0 - 200 
Model
Electr. output
Measuring range
10 ... 100% rel.h.
0 ... 100% rel.h.
-30 ... +50 °C
945 ... 1052 hPa
wall case
PC board
0 ... 20 mA
4 ... 20 mA
0 ... 1 V
0 ... 10 V
Ambient temp.
Operating voltage
Protection
Dimension
Case
PC board
Weight
0 ... 40 °C
230 V / 50 Hz
IP 65
Display range
10 ... 100% rel. h.
0 ... 100% rel. h.
-100.0 ... +199.9 °C
945 ... 1053 hPa
Pt 100 ( only temp. )
0 ... 20 mA
4 ... 20 mA
0 ... +10 V
0 ... +5 V
(only pressure)
±1 digit
LED, red, 13 mm high
230 V / 50 Hz
panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
200 x 120 x 75 mm
170 x 100 x 30 mm
0.65 kg. resp. 0.25 kg
Digital Indicators
Digital Indicator
for panel installation
Flat-section indicator
for display of humidity,
temperature or pressure
values. The background
of the indicator is black
to facilitate reading of the
red digits.
Preferably switch panel or
front panel installation.
Digital Indicator
for panel installation
with 2 adjustable limit contacts
Flat-section indicator for display of humidity, temperature
or pressure values.
Two setting knobs on the front
panel serve for setting both the
potential-free relay-contacts.
The background of the
indicator is black to facilitate
reading of the red digits.
Preferably switch panel or
front panel installation.
1.1044.00.xxx
1.1044.02.xxx
2.1044.00.xxx
3.1044.00.xxx
.000
.040
.041
.061
.073
Electr. input
Resolution
Display
Operating voltage
Model
Protection
Dimension
Weight
1.1045.00.xxx
1.1045.00.xxx
2.1045.00.xxx
3.1045.00.xxx
.000
.040
.041
.061
.073
Display range
Electr. input
Resolution
Display
Type of contact
Operating voltage
Model
Protection
Dimension
Weight
10 ... 100% rel. h.
0 ... 100% rel. h
-100.0 ... +199.9 °C
945 ... 1052 hPa
Pt 100 ( only temp.)
4 ... 20 mA
0 ... 20 mA
0 ... +10 V
0 ... +5 V
(only pressure)
±1 digit
LED, red, 13 mm high
throw over switch
230 V / 50 Hz
panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
37
Accessories
Description
Order No.
Technical Data
Weather Display LED
9.2750.xx.900
.x0.
Operating voltage
Displaying measuring
instrument for four
meteorological parameters (for
ex. temperature, rel. humidity,
global radiation, air pressure).
Instrument with serial interface
for the receipt of measuring
data and output to processing
systems.
.x1.
Display range
Display
Measuring range
• Operation and setting
through front side keys.
• Display sequence and
formatting of weather
parameters are configurable
acc. to customer’s request.
• Display possible from
instantaneous, min., max.
and mean value for each
parameter.
• Receipt of display parameters
via a serial interface.
For ex. for connection to
THIES-datalogger systems
or THIES-sensor interface.
• Output of display parameters
via a serial interface.
Weather Display LED
Displaying measuring
instrument for four
meteorological parameters (for
ex. temperature, rel. humidity,
global radiation, air pressure).
Instrument with integrated
serial interface and analogueinterface for data input and
-output
The instrument is optionally
equipped with an integrated
pressure sensor.
• Operation and setting
through front side keys.
• Display sequence and
formatting of weather
parameters are configurable
acc. to customer’s request.
• Display possible from
instantaneous, min., max.
and mean value for each
parameter.
38
Meas. Value input:
• Receipt of display parameters
via a serial interface
• Receipt and acquisition of
the display parameters via an
integrated analogue interface.
The analogue IF is configurable
acc. to customer’s request.
• Serial output of the display parameters via a serial interface.
• Analogue output of max. two
display parameters via an integrated analogue interface (U/I
is selectable).
Resolution
Digital-Interface
Type
Baud rate
Parameter
Temperature range
Construction
Dimension
Protection
Weight
EMC
9.2750.xx.901
.x0.
Operating voltage
.x1.
.0x.
.1x.
W/o integrated
pressure sensor
With integrated
pressure sensor
Display range
Display
Meas. range
Resolution
Digital interface
Type
Baud rate
Parameter
Analog Input
Analog output
Temperature range
construction
Dimension
Protection
Weight
EMC
Pressure sensor
Meas. range
Resolution
Accuracy
230 V / 50 Hz; 24 V AC
12 - 35 V DC
115 V / 50 Hz; 24 V AC
12 - 35 V DC
-9:999 … +99999
4 x 5 digit, LED red,
14 mm high
4 x min /
max LED-arrow
depending on
parameter
depending on
parameter
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1,
-10 … 50 °C
Switch panel
mounting
144 x 144 x 135 mm
IP 23
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
230 V / 50 Hz; 24 V AC
12 - 35 V DC
115 V / 50 Hz; 24 V AC
12 - 35 V DC
-9.999 … +99999
4 x 5 digit, LED red,
14 mm high
4 x min / max
LED-arrow
depending
on parameter
depending
on parameter
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1,
3 (4) x 0 ... 10 V or
0 (4) ... 20 mA
1 x Pt 100
2 x 0 ... 10 V or
0 (4) ... 20 mA
-10 … 50 °C
Switch panel mounting
144 x 144 x 135 mm
IP 23
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
750 ... 1100 hPa
0.1 hPa
±0.5 hPa (at 25 °C)
Accessories
Description
Order No.
Technical Data
Hangers / Holders /
Adapters
Hanger 1 m
Hangers are used to mount
measuring transmitters to
telescope masts. The extension
is 1 m from the mast. The
outer end has a holder
specially designed for the
respective data transmitter.
Traverse
For joint mounting of
2 measuring transmitters on
a mast, partly in combination
with the pins mentioned in the
following.
4.3185.xx.xxx.
.00.
.01.
.02.
.000
.001
4.3171.30.000
Clamping range
suitable for
Ø 60 - 132 mm
Ø 40 - 80 mm
Ø 48 - 50 mm
1.1025.51...
2.1260...
Tube diameter
Material
Weight
50 mm
aluminium
1.8 kg
Clamping range
Transmitter distance
Material
Ø 48 ... 102 mm
0.8 m
aluminium / stainless
steel
0.35 kg
Weight
Traverse short
4.3171.40.000
Clamping range
Transmitter distance
Material
Weight
Ø 48 ... 102 mm
0.4 m to the mast
aluminium / stainless
steel
0.30 kg
Holder compact
506347
Material
Clamping range
Dimension
Weight
stainless steel
Ø 35 ... 50 mm
80 x 150 mm
0.35 kg
Peg complete
506350
Material
Dimension
Weight
POM
Ø 40 x 65 mm
0.1 kg
For mounting of a measuring
transmitter on a mast, partly in
combination with the adapters
mentioned in the following.
The holder is used to mount
a measuring transmitter to a
mast tube or a wall, partly in
combination with the adapters
mentioned in the following.
The pin is used to mount the
measuring transmitter situated
in the weather and thermal
radiation shield, order no.
1.1025.55.000/100 on
traverses or holders compact.
Support for wall mounting 1.1005.54.903
Not depicted
For mounting the HygroThermo Transmitter compact
(1.1005.54…) or Temperature
Sensor compact (2.1280…)
onto a wall, radiation- and
precipitation-protected use
(for ex. indoor)
Please contact us for additional accessories such as cables and cable connections as well as
supplementary mast constructions or supplementary system constructions. We will prepare an
offer tailored to your individual requirements.
39
Your Notice
40
THIES –
as versatile as require
the international tasks
Weather and environmental
monitoring technology
needs a competent partner
THIES CLIMA – worldwide
THIES assumes complete
supervision of the task at
hand, from project planning to
the installation of the system,
from staff training to the
processing of the measurement results.
Should you want to contact
one of our foreign partners,
please write or call us first in
Göttingen. We will provide
you with the exact address.
ADOLF THIES GMBH & CO KG
Meteorology-Environmental Technology
Box 3536 + 3541
D-37025 Göttingen
Phone +49 551 7 90 01 –0
Fax
+49 551 7 90 01 –65
E-Mail info@thiesclima.com
www.thiesclima.com
Our partners in:
Arabemirates
Argentinia
Australia
Austria
Belgium
Brasil
Canada
Chile
China
Denmark
Ecuador
Egypt
Finland
France
Greece
Hongkong
India
Indonesia
Iran
Italy
Kolumbia
Korea
Malaysia
Maroc
Mexico
Nepal
Netherland
Norway
Peru
Philippines
Poland
Portugal
Quatar
Romania
Saudi Arabia
Singapore
South-Africa
Spain
Sweden
Switzerland
Syria
Taiwan
Turkey
United Kingdom
Venezuela
Vietnam
DIN EN ISO 9001
Certificate: 08/100/1688
010127/12/05
Climatic measurement and
intelligent analysis are
international tasks. They do
not only demand a worldwide
cooperation of the responsible authorities, but also a
comprehensive network of
sensors and analytical systems.
We have developed a smoothly
functioning system of partners
and subsidiaries throughout
the world to provide expert
advice there where you need it.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising