Vacuum generators OVEM

Vacuum generators OVEM
Vacuum generators OVEM
-V- New
Vacuum generators OVEM
Key features
At a glance
Accelerated vacuum reduction for placing
the workpiece safely, through the use of
an integrated solenoid valve to control the
ejector pulse
Quick and secure installation thanks to
a QS fitting
Central electrical connection with M12 plug
Fast vacuum build-up through integrated
solenoid valve for controlling the
compressed air supply
Monitoring and visualisation of the vacuum
by means of a vacuum sensor with LCD
display (bar)
Pressure drop is prevented
by an integrated non-return valve
Adjustment of the ejector impulse via
a flow control screw
An integrated filter prevents contamination
of the vacuum generator
Maintenance-free operation and reduced
noise level through integrated, open
silencer
The innovative vacuum generator
Wide range of configuration options
The modular vacuum generator series
OVEM offers a wide range of individual
selectable functions, making it possible to find a solution for the most
varied of applications.
• 3 nominal sizes
0.45 … 0.95 mm
• Generator characteristics in two
versions: high vacuum and high
suction rate
• Integrated solenoid valve for
controlling the ejector pulse
Reliable
• Constant monitoring of the entire
vacuum system via a vacuum
sensor with LCD display to reduce
downtimes (condition monitoring)
• Prevention of pressure loss by
means of an integrated air saving
function in conjunction with an
integrated non-return valve
2
Economical
• Integrated solenoid valve for controlling the compressed air using
two different switching functions
– NC – normally closed
– NO – normally open
• Electrical switching output of the
vacuum sensor can be selected
• Alternatively selectable vacuum
display (inchHg)
• Different pneumatic connection
options (QS fitting or female thread)
Space-saving
All functions are compactly integrated
in one unit.
• No protruding elements such as
valves or vacuum sensors
• Space-optimised installation is
possible as all the control elements
can be accessed from one side
Internet: www.festo.com/catalogue/...
• Short switching times thanks to
integrated solenoid valves
– Vacuum ON/OFF
– Ejector pulse
• Quick, precise and safe placement
of the workpiece via the ejector
pulse
• Cost saving through integrated air
saving function
• Cost saving through preventive
maintenance/service thanks to
maintenance indicator
• High-performance supply to several
vacuum generators via a common
supply manifold ( Page 14)
Easy to maintain
• Integrated filter with inspection
window for maintenance display
• Reduced contamination of the
vacuum generator thanks to an
open silencer
User-friendly
• Simple installation with M12 plug
and QS fittings
• Simple mounting via screws
• All control elements on one side
• Vacuum is displayed numerically
and as a bar chart on the LCD
display
• Important parameters and diagnostic information are displayed on the
LCD display
• Quiet operation due to integrated
silencers
Variable mounting options
• Direct mounting or with mounting
bracket
• Simple mounting on H-rail with
accessories
• Forming a block of several vacuum
generators on a common supply
manifold ( Page 14)
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Key features
Operational principle of OVEM
Vacuum ON/OFF
Vacuum sensor
The compressed air supply is
controlled by an integrated solenoid
valve. The solenoid valve can be
supplied in two different switching
functions NC/NO.
• NC – normally closed:
The vacuum is generated when the
vacuum generator is pressurised
with compressed air and the
solenoid valve has been switched.
• NO – normally open:
The vacuum is generated when the
vacuum generator is pressurised
with compressed air and the
solenoid valve is in the normal
position.
Switching outputs/Switching input
The set reference value for the generated vacuum is monitored by an integrated vacuum sensor. If the reference
value is reached or if it is not reached
due to malfunctions (e.g. leakages,
dropped workpiece), the vacuum
sensor emits an electrical signal.
Vacuum monitoring is the basis for
the vacuum generator’s air saving
function.
Ejector pulse
The vacuum generator can be
connected to higher-order systems by
means of two digital switching outputs or one digital switching output
and one analogue input, and by
means of one digital switching input.
The switching outputs can be configured as normally open or normally
closed contacts. The switching function of the outputs can be stipulated
as a threshold or window comparator.
In the case of vacuum generators with
two switching outputs, the outputs
can be configured independently of
one another. This makes it possible to
use one generator to perform several
tasks in parallel and thus to reduce
production time, e.g. for quality
sorting of parts.
With a second integrated solenoid
valve, an ejector pulse is activated
and generated after the vacuum is
switched off to release the workpiece
safely from the suction cup and to
reduce the vacuum quickly.
If the desired threshold 1 is reached
for the vacuum, vacuum generation is
automatically switched off. A nonreturn valve prevents the reduction of
the vacuum.
Nonetheless, leakages (due to
e.g. rough workpiece surfaces) will
slowly reduce the vacuum. If the pressure drops below the threshold value
2 vacuum generation is switched on
automatically. Vacuum is generated
until the set threshold value 1 is
reached again.
The most important operating
parameters:
• vacuum
• evacuation time
• air supply time
are constantly measured in the
vacuum generator and compared to
the individually set reference values
(condition monitoring). Any deviations
from the reference values are determined by the vacuum generator and
displayed (diagnostics). In addition,
an electrical signal is transmitted to
the master controller.
This makes it possible to take
preventive action:
• performing timely maintenance in
order e.g. to prevent machine failure
or downtimes
• and to guarantee process reliability
(adherence to the cycle time).
Air saving function LS (-CE, -OE)
50 mbar (fix)
Hysteresis
1
2
Condition monitoring and diagnosis
1
2
2
2
TE
1 Cycle time
2 Monitoring
TE Evacuation time
2008/09 – Subject to change
T1
TB
T2
T1 Transport time
TB Air supply time
T2 Return time
Internet: www.festo.com/catalogue/...
3
-V- New
Vacuum generators OVEM
Peripherals overview
OVEM-…-PL/PO-…1)
OVEM-…-QS/QO/GN/GO-…
4
8
9
1
2
1
aJ
3
8
5
6
6
7
1)
7
Hollow bolt 9 and mounting bracket aJ are included in the scope of delivery of the OVEM-…-PL/PO-….
Mounting attachments and accessories
OVEM-…-QS/QO/GN/GO-…
QS
QO
GN
1
2
3
4
Connecting cable
NEBU-M12G5
H-rail mounting
OABM-H
Mounting bracket
HRM-1
Blanking plug
OASC-G1-P
5
6
7
8
–
–
4
Common supply manifold
OABM-P…
Silencer extension
UOMS-¼
Suction gripper
ESG
Push-in fitting
QS
Suction cup holder
ESH
Suction cup
ESS
Page/Internet
OVEM-…-PL/PO-…
PL
PO
–
–
–
–
–
GO
–
15
hrm-1
15
14
–
–
nebu
–
uoms
esg
quick star
esh
ess
Internet: www.festo.com/catalogue/...
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Type codes
OVEM
—
10
—
H
—
B
— QO
—
CE
—
N
—
2P
—
Type
OVEM
Vacuum generator
Nominal size of Laval nozzle [mm]
05
07
10
0.45
0.7
0.95
Ejector characteristic
H
L
High vacuum
High suction rate
Housing width
B
Grid dimension 20 mm
Pneumatic connections
QS
QO
GN
GO
PL
PO
P-V-R via QS fitting
P-V via QS fitting,
R with open silencer
P-V-R via female thread
P-V via female thread,
R with open silencer
Common supply manifold prepared,
V-R with QS fitting
Common supply manifold prepared, V with QS fitting,
R with open silencer
Normal position of the vacuum generator
ON
OE
CN
CE
NO, normally open (vacuum generation)
NO, normally open with ejector pulse
NC, normally closed (vacuum generation)
NC, normally closed with ejector pulse
Electrical connection
N
M12 plug (5-pin)
Vacuum sensor, electrical switching output
2P
2N
PU
PI
NU
NI
2 switching outputs PNP
2 switching outputs NPN
1 switching output PNP, 1 analogue output 0 … 10 V
1 switching output PNP, 1 analogue output 4 … 20 mA
1 switching output NPN, 1 analogue output 0 … 10 V
1 switching output NPN, 1 analogue output 4 … 20 mA
Vacuum display
–
H
bar
inchHg
2008/09 – Subject to change
Internet: www.festo.com/catalogue/...
5
-V- New
Vacuum generators OVEM
Technical data
Function
NC, normally closed:
• Ejector pulse
• QS fitting or female G thread
• With open silencer
• Prepared for common supply
manifold
-Q-L-
Temperature range
0 … +50 °C
Operating pressure
2 … 8 bar
NO, normally open:
• Ejector pulse
• QS fitting or female G thread
• With open silencer
• Prepared for common supply
manifold
General technical data
Type
Pneumatic connections
Nominal size of Laval nozzle
Grid dimension
Ejector
j
characteristic
Grade of filtration
Duty cycle
Constructional design
Mounting position
Type
yp of mountingg
Pneumatic connection 1
Vacuum port
Pneumatic connection 3
Design, silencer
Integrated
g
function
OVEM-05
[mm]
[mm]
[µm]
[%]
ON/CN
/
OE/CE
/
Valve function
Manual override
6
ON/OE
CN/CE
OVEM-07
QO GO PO QO GO PO
0.45
0.7
20
High vacuum/Standard H
High suction rate/Standard L
40
100
Modular
Any
Via through-holes
Via female thread
Via accessories
QS6 Gx –
QS8 G¼ –
QS6 Gx QS6 QS8 G¼ QS8
Open silencer, integrated
Open
On-off valve, electrical
Vacuum sensor
Filter
Open silencer
On-off valve, electrical
Ejector pulse, electrical
Flow control valve
Vacuum sensor
Air saving function, electrical
Non-return valves
Filter
Open silencer
Open
Closed
Non-detenting (pushing)
Additionally via operating buttons
Internet: www.festo.com/catalogue/...
OVEM-10
QO GO
0.95
OVEM-05
PO
QS GN
0.45
OVEM-07
PL
QS
0.7
GN
OVEM-10
PL
QS GN
0.95
PL
QS8 G¼ –
QS6 Gx –
QS8 G¼ –
QS8 G¼ –
QS8 G¼ QS8 QS6 Gx QS6 QS8 G¼ QS8 QS8 G¼ QS8
QS8 Gx QS8 QS8 GÅ QS8 QS8 GÅ QS8
–
–
–
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Technical data
Operating and environmental conditions
Type
OVEM-05/07/10-…-QO/PO/GO
Operating pressure
[bar]
Nominal operating pressure
[bar]
Operating medium
Ambient temperature
[°C]
Temperature of medium
[°C]
Corrosion resistance class CRC1)
CE mark (see declaration of conformity)
Certification
2…8
2…6
6
Filtered compressed air, unlubricated, grade of filtration 40 µm
0 … +50
0 … +50
2
To EU EMC Directive
C-Tick
1)
Corrosion resistance class 2 according to Festo standard 940 070
Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or
lubricating agents.
Performance data – High vacuum
Type
OVEM-05
Normal position of the vacuum generator
Max. vacuum
[%]
Operating pressure for max. vacuum [bar]
ON
93
5.1
Max. suction rate with respect
to atmosphere
Suction rate at p1 = 6 bar
[l/min]
[l/min]
CE
ON
OVEM-10
OE
CN
CE
ON
6
16
19.5
5.9
15.1
16.8
Noise level at p1 = 6 bar
51
2
4.8
2
1.9
0.4
1.9
0.4
58
1.2
OE
CN
CE
0.2
1.2
0.2
OE
CN
CE
0.2
0.8
0.2
73
Time required to build up vacuum to –0.05 bar.
Performance data – High suction rate
Type
OVEM-05
Normal position of the vacuum generator
Max. suction rate with respect
[l/min]
to atmosphere
Suction rate at p1 = 6 bar
[l/min]
ON
13
Pressurisation time1) for 1 l volume, [s]
at p1 = 6 bar
2
Noise level at p1 = 6 bar
45
1)
CN
3.5
4.8
db(A)
OVEM-07
OE
4.1
Pressurisation time1) for 1 l volume, [s]
at p1 = 6 bar
1)
OVEM-05/07/10-…-QS/GN/PL
db(A)
OVEM-07
OE
CN
CE
12.8
ON
31.5
OVEM-10
OE
CN
CE
31.5
1.3
2
1.3
1
ON
45
45
0.2
1
0.2
53
0.8
64
Time required to build up vacuum to –0.05 bar.
2008/09 – Subject to change
Internet: www.festo.com/catalogue/...
7
-V- New
Vacuum generators OVEM
Technical data
Technical data – Vacuum sensor
Electrical switching output
Mechanical
Measured variable
Measuring principle
Pressure measuring range
Accuracy FS1)
Repetition accuracy
switching value FS1)
Setting options
Threshold value setting range
Hysteresis setting range
Type of display
Indicating range
Displayable
p y
units
2P
[bar]
[%]
[%]
[bar]
[bar]
[bar]
–
H
Switching status display
Switching position display
Electrical connection
Electrical
Switching output
Standard switching input
Switchingg element function
Switchingg function
Operating voltage range
Idle current
Coil characteristics 24 V DC
[V DC]
[mA]
[[W]]
Residual current
Max. output current
Voltage drop
Inductive protective circuit
Switch-on suppression
Analogue
g output
p
[mA]
[mA]
[V]
Permitted load resistance
analogue output
Accuracy of analogue output FS1)
Protection against short circuit
Protection against overloading
Protection against polarity reversal
Protection class
Electrical protection class
1)
8
[V]
[mA]
[Ohm]
[%]
2N
PU
NU
PI
NI
1x NPN
1x PNP
1x NPN
Relative pressure
Piezoresistive
–1 … 0
3
0.6
Via display and keys
–0.999 … 0
–0.9 … 0
4-character alphanumerical, backlit LCD
–0.999 … 0
bar
inchHg
Optical
LCD
Plug M12x1, 5-pin
2x PNP
2x NPN
IEC 61131-2
NO contact
NC contact
Window comparator
Threshold comparator
20.4 … 27.6
< 70
Low current phase: 0.3
High current phase: 2.55
0.1
100
≤ 1.5
Adapted to MZ, MY, ME coils
Yes
–
–
–
1x PNP
–
Yes
Yes
For all electrical connections
IP65
III
4
0 … 10
–
Min. 2000
–
4 … 20
Max. 500
%FS = % of the measuring range final value (full scale)
Internet: www.festo.com/catalogue/...
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Technical data
Materials
Sectional view
1 2
3
4
5
6
7
8
1
9
Vacuum generator OVEM-05/07/10
1
2
3
4
5
Fitting
Plug contacts
Plug housing
Inspection window
Housing
6
7
Key pad
Adjusting
j
g screw
8
9
Filter housing
Silencer
–
–
–
–
–
Jet nozzle
Receiver nozzle
Filter
Seals
Hollow bolt
–
Mountingg bracket
Note on materials
CE
OE
QO
GO
PO
PL
PO
PL
PO
QO
GO
PO
Nickel-plated brass
Gold-plated brass
Nickel-plated brass
Polyamide
Die-cast aluminium,
reinforced polyamide
Thermoplastic polyurethane elastomer
Steel
Reinforced polyamide
Wrought
g aluminium alloy,
y,
PU foam
Wrought aluminium alloy
Polyacetal
Fabric, polyamide, sintered steel
Nitrile rubber
Wrought
g aluminium alloyy
Stainless steel
Contains PWIS (paint-wetting
(p
g
impairment
p
substances))
k
2008/09 – Subject to change
Internet: www.festo.com/catalogue/...
9
-V- New
Vacuum generators OVEM
Technical data
Vacuum pu as a function of operating pressure p1
High vacuum
OVEM-05-H
OVEM-07-H
OVEM-10-H
High suction rate
OVEM-05-L
OVEM-07-L
OVEM-10-L
Evacuation time t as a function of vacuum pu for 1 l volume at 6 bar operating pressure
High vacuum
High suction rate
OVEM-05-H
OVEM-07-H
OVEM-10-H
OVEM-05-L
OVEM-07-L
OVEM-10-L
Air consumption qn as a function of operating pressure p1
High vacuum/high suction rate
OVEM-05
OVEM-07
OVEM-10
10
Internet: www.festo.com/catalogue/...
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Technical data
Download CAD data www.festo.com
Dimensions
1
2
3
4
Supply port
Vacuum port
Silencer (SD)/Exhaust port
Electrical connection to fit
NEBU-M12G5-K-…
5 Mounting thread M3
Max. tightening torque 0.8 Nm
6 Mounting hole
Max. tightening torque 2.5 Nm
7 Mounting bracket only for
OVEM-…-PL/PO
OVEM-05
OVEM-07/10
Type
yp
OVEM-05-…-QS-…
OVEM-05-…-QO-…
OVEM-05-…-PL-…
OVEM-05-…-PO-…
OVEM-05-…-GN-…
OVEM-05-…-GO-…
OVEM-07/10-…-QS-…
OVEM-07/10-…-QO-…
OVEM-07/10-…-PL-…
OVEM-07/10-…-PO-…
OVEM-07/10-…-GN-…
OVEM-07/10-…-GO-…
2008/09 – Subject to change
Pneumatic connections
P
V
R
D1
D2
QS6
QS6
G¼
Gx
Gx
QS8
QS8
G¼
G¼
G¼
QS8
SD
QS8
SD
Gx
SD
QS8
SD
QS8
SD
Gy
SD
L1
L2
L33
65
6.5
65
6.5
115
–
82
8.2
82
8.2
65
6.5
65
6.5
128
–
17 2
17.2
17 2
17.2
Internet: www.festo.com/catalogue/...
L4
12
–
12
–
8.2
–
12
17.3
12
17.3
–
17.3
L55
–
160 5
160.5
–
–
160 5
160.5
–
11
-V- New
Vacuum generators OVEM
Technical data
Ordering data and weight
Circuit symbol
Description
Electrical
Nominal
switching output size
[mm]
Weight
Part No.
Type
With open
p silencer
2x PNP
0.45
0.7
0.95
317
3322
538834
538835
538836
OVEM-05-H-B-QO-CN-N-2P
OVEM-07-H-B-QO-CN-N-2P
OVEM-10-H-B-QO-CN-N-2P
With ejector
j
pulse
p
and
open
p silencers
2x PNP
0.45
0.7
0.95
0.7
0.95
325
331
33
538831
538832
538833
540018
540019
OVEM-05-H-B-QO-CE-N-2P
OVEM-07-H-B-QO-CE-N-2P
OVEM-10-H-B-QO-CE-N-2P
OVEM-07-H-B-QO-CE-N-2N
OVEM-10-H-B-QO-CE-N-2N
0.7
0.95
0.7
0.95
334
33
540015
540016
540012
540013
OVEM-07-H-B-GO-CE-N-2P
OVEM-10-H-B-GO-CE-N-2P
OVEM-07-H-B-GO-CE-N-2N
OVEM-10-H-B-GO-CE-N-2N
[g]
Normally closed
2x NPN
2x PNP
2x NPN
331
33
334
33
Normally open
With open
p silencer
2x PNP
0.45
0.7
0.95
317
3322
538828
538829
538830
OVEM-05-H-B-QO-ON-N-2P
OVEM-07-H-B-QO-ON-N-2P
OVEM-10-H-B-QO-ON-N-2P
With ejector
j
pulse
p
and
open
p silencers
2x PNP
0.45
0.7
0.95
0.7
0.95
325
331
33
538825
538826
538827
540009
540010
OVEM-05-H-B-QO-OE-N-2P
OVEM-07-H-B-QO-OE-N-2P
OVEM-10-H-B-QO-OE-N-2P
OVEM-07-H-B-QO-OE-N-2N
OVEM-10-H-B-QO-OE-N-2N
0.7
0.95
0.7
0.95
334
33
540006
540007
540003
540004
OVEM-07-H-B-GO-OE-N-2P
OVEM-10-H-B-GO-OE-N-2P
OVEM-07-H-B-GO-OE-N-2N
OVEM-10-H-B-GO-OE-N-2N
2x NPN
2x PNP
2x NPN
12
Internet: www.festo.com/catalogue/...
331
33
334
33
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Ordering data – Modular products
0
M Mandatory data
0
O Options
Module No.
Nominal size of Laval
nozzle
Vacuum generator
539074
Order
example
539074
Housing size/width
Ejector characteristics
Normal position of the
vacuum generator
Pneumatic connections
Vacuum sensor electrical
switching output
Electrical connection
Alternative vacuum
display
OVEM
05
07
10
H
L
B
QS
QO
GN
GO
PL
PO
ON
OE
CN
CE
N
2P
PU
PI
2N
NU
NI
H
OVEM
– 05
– H
– B
– QO
– ON
– N
– 2P
– H
Ordering table
Size
20
0
M Module No.
539074
Conditions
Vacuum generator
Nominal size of Laval
nozzle
Vacuum generator with solenoid valve for vacuum on/off and manual override
[[mm]] 0.45
0.7
0.95
Ejector
j
characteristic
High vacuum
High suction rate
Housing size/width
[mm] 20
Pneumatic connections
All ports with QS fittings
Supply/vacuum port with QS fittings, exhaust port with open silencer
All ports with female G thread
Supply/vacuum port with female G threads, exhaust port with open silencer
Prepared for supply strip, vacuum port and exhaust port with QS fittings
Prepared for supply strip, vacuum port with QS fittings, exhaust port with open silencer
Normal position
p
of the vacuum
NO, normally open (vacuum generation)
ggenerator
NO, normally open (vacuum generation) with ejector pulse
NC, normally closed (no vacuum generation)
NC, normally closed (no vacuum generation) with ejector pulse
Electrical connection
M12 plug (5-pin)
0
O Vacuum sensor,,
electrical switchingg output
p
(gauge
(g
g in bar,, not for P1,, N1))
Switching output 2x PNP
Switching output 1 x PNP + U
Switching output 1 x PNP + I
Switching output 2 x NPN
Switching output 1 x NPN + U
Switching output 1 x NPN + I
inchHG
Alternative vacuum display
Transfer order code
539074
OVEM
2008/09 – Subject to change
–
–
– B
Code
Enter
code
OVEM
-05
-07
-10
-H
-L
-B
-QS
-QO
-GN
-GO
- PL
-PO
-ON
-OE
-CN
-CE
-N
OVEM
-B
-N
-2P
-PU
-PI
-2N
-NU
-NI
-H
–
–
– N
Internet: www.festo.com/catalogue/...
–
–
13
-V- New
Vacuum generators OVEM
Accessories
Common supply manifold OABM-P
for vacuum generators
OVEM-…-PL/PO
Pneumatic connection 1: G¾
Type of mounting: Via through-holes
Material: Wrought aluminium alloy
Note on material:
RoHS-compliant
1 Vacuum generator
2 Blanking plugs
Dimensions
Number of device positions
H1
H2
H3
4
6
8
118
162
206
102
146
190
66
110
154
Tubing inner diameter di as a function of total air consumption qnN
Total air consumption [l/min]
50
75
154
175
Tubing inner diameter1) [mm]
≥ 2.5 ≥ 2.9 ≥ 3.8 ≥ 4
Recommended tubing
PUN-4 PUN-6
1)
225
310
400
480
500
750
890
1000
1190
1340
1850
2240
2300
2900
≥ 4.4
≥5
≥ 5.5
≥ 5.9
≥6
≥7
≥ 7.5
≥8
≥ 8.4
≥ 8.8
≥ 10
≥ 10.8 ≥ 11
≥ 12
PUN-8
PUN-10
PUN-12
PUN-16
Technical data Internet: pun, pan
PAN-16
With a tubing length of 3 m
-H-
Note
The total air consumption of the
completely equipped common supply
manifold can be determined by
adding up the individual consumption values of the generators used. It
should be noted that in the case of
vacuum generators with ejector pulse
(OE, CE) the individually set values for
the ejector pulse (duration and intensity) can lead to a significantly higher
level of air consumption.
Ordering data and weight
Common supply
pp y manifold
1)
14
Number of
device positions
CRC1)
Weight
[g]
Part No.
Type
yp
4
6
8
2
2
2
767
1045
1330
549456
549457
549458
OABM-P-4
OABM-P-6
OABM-P-8
Corrosion resistance class 2 according to Festo standard 940 070
Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or
lubricating agents.
Internet: www.festo.com/catalogue/...
Subject to change – 2008/09
-V- New
Vacuum generators OVEM
Accessories
Blanking plug OASC-G1-P
for common supply manifold
OABM-P-…
Type of mounting: Threaded
Max. tightening torque: 10 Nm
Material:
Hollow bolt: Wrought aluminium alloy
Blanking cap: Steel
Seals: Steel, nitrile rubber
Note on material:
RoHS-compliant
Ordering data
Blanking plug
1)
CRC1)
Weight
[g]
Part No.
Type
yp
2
53
549460
OASC-G1-P
Corrosion resistance class 2 according to Festo standard 940 070
Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or
lubricating agents.
H-rail mounting
OABM-H
for vacuum generator OVEM
Max. tightening torque for H-rail
mounting: 0.8 Nm
Material: Galvanised steel
Note on material:
RoHS-compliant
1 Vacuum generator
2 H-rail TH-35-15
3 Screws M3x6 (included)
Ordering data
H-rail mounting
2008/09 – Subject to change
Weight
[g]
Part No.
Type
yp
52
549461
OABM-H
Internet: www.festo.com/catalogue/...
15
Product Range and Company Overview
A Complete Suite of Automation Services
Our experienced engineers provide complete support at every stage of your development process, including: conceptualization,
analysis, engineering, design, assembly, documentation, validation, and production.
Custom Automation Components
Complete custom engineered solutions
Custom Control Cabinets
Comprehensive engineering support
and on-site services
Complete Systems
Shipment, stocking and storage services
The Broadest Range of Automation Components
With a comprehensive line of more than 30,000 automation components, Festo is capable of solving the most complex
automation requirements.
Electromechanical
Electromechanical actuators, motors,
controllers & drives
Pneumatics
Pneumatic linear and rotary actuators,
valves, and air supply
PLCs and I/O Devices
PLC's, operator interfaces, sensors
and I/O devices
Supporting Advanced Automation… As No One Else Can!
Festo is a leading global manufacturer of pneumatic and electromechanical systems, components and controls for industrial automation,
with more than 12,000 employees in 56 national headquarters serving more than 180 countries. For more than 80 years, Festo has
continuously elevated the state of manufacturing with innovations and optimized motion control solutions that deliver higher performing,
more profitable automated manufacturing and processing equipment. Our dedication to the advancement of automation extends beyond
technology to the education and development of current and future automation and robotics designers with simulation tools, teaching
programs, and on-site services.
Quality Assurance, ISO 9001 and ISO 14001 Certifications
Festo Corporation is committed to supply all Festo products and services that will meet or exceed
our customers’ requirements in product quality, delivery, customer service and satisfaction.
To meet this commitment, we strive to ensure a consistent, integrated, and systematic approach
to management that will meet or exceed the requirements of the ISO 9001 standard for Quality
Management and the ISO 14001 standard for Environmental Management.
© Copyright 2008, Festo Corporation. While every effort is made to ensure that all dimensions and specifications are correct, Festo cannot guarantee that
publications are completely free of any error, in particular typing or printing errors. Accordingly, Festo cannot be held responsible for the same. For Liability and
Warranty conditions, refer to our “Terms and Conditions of Sale”, available from your local Festo office. All rights reserved. No part of this publication may be
reproduced, distributed, or transmitted in any form or by any means, electronic, mechanical, photocopying or otherwise, without the prior written permission of
Festo. All technical data subject to change according to technical update.
Printed on recycled paper at New Horizon Graphic, Inc., FSC certified as an environmentally friendly printing plant.
Festo North America
United States
Customer Resource Center
502 Earth City Expy., Suite 125
Earth City, MO 63045
Design and Manufacturing Operations
For ordering assistance, or to find
your nearest Festo Distributor,
Call:
1.800.99.FESTO
Fax:
1.800.96.FESTO
Email: customer.service@us.festo.com
For technical support,
Call:
1.866.GO.FESTO
Fax:
1.800.96.FESTO
Email: product.support@us.festo.com
Headquarters
Festo Corporation
395 Moreland Road
P.O. Box 18023
Hauppauge, NY 11788
www.festo.com/us
East: 395 Moreland Road, Hauppauge, NY 11788
Sales Offices
Appleton
N. 922 Tower View Drive, Suite N
Greenville, WI 54942
Boston
120 Presidential Way, Suite 330
Woburn, MA 01801
Chicago
1441 East Business Center Drive
Mt. Prospect, IL 60056
Central: 1441 East Business Center Drive, Mt. Prospect, IL 60056
Dallas
1825 Lakeway Drive, Suite 600
Lewisville, TX 75057
Detroit - Automotive Engineering Center
2601 Cambridge Court, Suite 320
Auburn Hills, MI 48326
New York
395 Moreland Road
Hauppauge, NY 11788
Silicon Valley
4935 Southfront Road, Suite F
Livermore, CA 94550
West: 4935 Southfront Road, Suite F, Livermore, CA 94550
Mexico
Canada
Headquarters
Festo Pneumatic, S.A.
Av. Ceylán 3, Col. Tequesquinahuac
54020 Tlalnepantla, Edo. de México
Call:
011 52 [55] 53 21 66 00
Fax:
011 52 [55] 53 21 66 65
Email:
festo.mexico@mx.festo.com
www.festo.com/mx
Headquarters
Festo Inc.
5300 Explorer Drive
Mississauga, Ontario L4W 5G4
Call:
1.905.624.9000
Fax:
1.905.624.9001
Email:
info.ca@ca.festo.com
www.festo.com/ca
Festo Worldwide
Argentina Australia Austria Belarus Belgium Brazil Bulgaria Canada Chile China Colombia Croatia Czech Republic Denmark
Estonia Finland France Germany Great Britain Greece Hong Kong Hungary India Indonesia Iran Ireland Israel Italy Japan
Latvia Lithuania Malaysia Mexico Netherlands New Zealand Norway Peru Philippines Poland Romania Russia Serbia Singapore
Slovakia Slovenia South Africa South Korea Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United States Venezuela
www.festo.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising