Installation Instructions

Installation Instructions
SELECTRONIC®
MODEL NUMBERS
Installation Instructions
Innsbrook Lavatory Proximity Faucet
605X.202
605X.204
605X.205
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
Product No.’s & Options
1
Specifications
2
Faucet Installation
2-3
Electrical Installation
4-6
Start-up / Maintenance
7-8
FAQ’s / Troubleshooting
9-10
Parts
11
Certified to comply with:
• ASME A112.18.1
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
© 2016 AS America Inc.
1
M965652 Rev. 1.7 (10/16)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure
that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping
The illustration below shows the fitting and all loose items after they have been removed
from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Spout Assembly
3. Mounting Nuts
4. Control Box
5. Supply Hose
6. Mixing Valve (optional, must be ordered separately)
7. Control Box Cover Screws
POWER KITS SOLD SEPARATELY
PRODUCT No.s
6059.202
6059.205
Plug-In AC
Power Kit
PK00.PAC
Hard-Wired AC
Power Kit
Multi-AC
Power Kit
PK00.HAC
PK00.MAC
2
Base Product
DO NOT REMOVE
PROTECTIVE
FILM FROM
SENSOR EYE UNTIL
INSTALLATION IS
COMPLETE.
1
3
Installation Instructions
SELECTRONIC®
MODEL NUMBERS
Hard-Wired AC Powered Innsbrook
Lavatory Proximity Faucet
605X.202
605X.204
605X.205
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
Product No.’s & Options
1
2
Faucet Installation
2-3
Electrical Installation
4-6
Start-up / Maintenance
7-8
FAQ’s / Troubleshooting
9-10
Parts
11
ASME A112.18.1
•
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
4
7
5
605XTMV
Mixing Valve
6
2
M965652 Rev. 1.7 (10/16)
Roughing-in Dimensions
Fig. 1
GENERAL DESCRIPTION
175mm
(6-7/8)
162mm
(6-3/8)
FINISHED
WALL
108mm
(4-1/4)
35mm
(1-3/8)
DIA.
3 HOLES
57mm
(2-1/4)
124mm
(4-7/8)
MOUNTING
SURFACE
Note:All plumbing and electrical wiring must be
installed in accordance with applicable codes,
regulations and standards.
38mm
(1-1/2)
MAX.
125mm
(4-7/8)
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
102mm
(4)
114mm
(4-1/2)
81mm
(3-3/16)
Electronic faucet with proximity operation. Vandal
resistant solid brass construction single post mounting.
Operates on DC (battery/power pack) or AC permanent
power (plug-in/hardwire). In-line strainer for solenoid
is integral. Single inlet 3/8 compression, built-in check
valves, and flexible stainless steel 16-1/4" reach inlet
hose for spout connection.
155mm
(6-1/8)
381mm
(15)
RECOMENDED ELECTRICAL BOX OR
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP ELECTRICAL BOX
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
500mm
(20")
HARD-WIRED AND MULTI AC 10’ MAX. CABLE LENGTH
3/8" COMP.
RECOMMENDED TOOLS
Fig. 2
1. Slip Joint Pliers
2. Adjustable Wrench
3. Plumbers’ Putty or Caulking
4. Phillips Screwdriver
5. Flat Blade Screwdriver
6. Electric Drill & 1/4" Drill Bit
7. Tape Measure
3
7
4
10'
Fig. 1a
SPOUT ASSEMBLY;Fig. 1
1 INSTALL
5
1
SENSOR
CABLES
Turn off hot and cold water
supplies before beginning.
1. Make sure PUTTY PLATE (1) is installed on FAUCET BODY (2). Fig. 1a.
2. Connect the two 27" EXTENSION CABLES (3)
to the Faucet Sensor Cables.
3. Insert 27" EXTENSION CABLES (3), FLEX
HOSE (4) and STUDS (5) through holes of
mounting surface.Fig. 1a.
4. From underside of mounting surface, install SPIN NUTS (6) onto MOUNTING STUDS (5). Fig. 1b.
5. Align FAUCET (2) and hand tighten SPIN NUTS (6) to secure faucet to mounting surface. Fig. 1b.
6
5
FAUCET INSTALLATION
CAUTION
2
1
2
4
3
3
Fig. 1b
5
6
6
5
3
M965652 Rev. 1.7 (10/16)
2 MOUNT CONTROL BOX; Fig. 2
Fig. 2
1. Determine location of CONTROL BOX (1). It must be located
with-in the 14" (356mm) by 21" (533mm) shaded area shown
in Figure 2 in order for electrical connections from the spout
assembly to be made.
NOTE: CONTROL BOX SUPPLY HOSE IS 20". DISTANCE
BETWEEN WALL SUPPLY AND ENCLOSURE (1)
MUST BE TAKEN INTO CONSIDERATION.
2. Remove tape from CONTROL BOX COVER (2)and pull off
COVER (2). Hold the CONTROL BOX (1)in desired
location and mark the four mounting holelocations as
shown.
NOTE: Find plastic bag containing 4 M5X16 screws to be
used for securing the CONTROL BOX COVER (1)
when installation is complete.
NOTE: For AC installation, make power supply connection
before mounting CONTROL BOX (1) to wall.
3. It is recommended that the CONTROL BOX (1) be
secured to a wall stud or cross brace within the wall using
the SCREWS (3) supplied. If the CONTROL BOX (1) is to
be installed on tile or plaster walls, the ANCHORS (4) and SCREWS (3) should be used.
3 C
ONNECT SPOUT HOSE TO CONTROL BOX;
LAVATORY RIM OR
MOUNTING SURFACE
14"
(356mm)
SUPPLIES
ENCLOSURE
MOUNTING
HOLES
1
2-3/4"
(71mm)
WASTE
20"
(500mm)
21"
(mm)
3"
(76mm)
3-3/4"
(96mm)
MOUNTING HOLES
3
1
2
4
1
Fig. 3
1
Fig. 3
1. Connect SUPPLY NUT (1) from spout hose to nipple on top
of ENCLOSURE (2). Tighten with adjustable wrench to make
a water tight connection. Fig. 3.
2
4 CONNECT WATER SUPPLY TO CONTROL
BOX AND WALL SUPPLY; Fig. 4, 4a
NOTE: If using the optional Mixing Valve, see sheet
#M968808 for installation instructions.
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on
CONTROL BOX (2).
2. Connect FLEXIBLE SUPPLY HOSE (3) to SUPPLY NUT (1)
on CONTROL BOX (2). Tighten to make a water tight
connection. Use two wrenches to tighten if necessary. Fig. 4.
3. Connect FLEXIBLE SUPPLY HOSE (3) directly to wall
supply. Connection on FLEXIBLE SUPPLY HOSE (3) is 3/8"
compression. Use adjustable wrench to tighten connection.
Do not over tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY HOSE (3) measures 20" from
the bottom of the CONTROL BOX (2) base. If additional
supply length is required, installer must purchase parts
separately.
Important: If FLEXIBLE SUPPLY HOSE (3) is too long, loop to
avoid kinking.
Fig. 4
2
1
4
3
Fig. 4a
COLD WATER OR
TEMPERED
WALL SUPPLY
3
4
M965652 Rev. 1.7 (10/16)
ELECTRICAL INSTALLATION
Product
Fig. 1
1
Page
Plug-In AC Power Kit (PK00.PAC)
6
Hard-Wired AC Power Kit (PK00.HAC)
6
Multi-AC Power Kit (PK00.MAC)
7
Fig. 1a
2
Fig. 1b
3
5a
5
A DC VERSIONS ; Fig. 1
• PWRX
• STANDARD BATTERY
INSTALL BATTERY
1. Remove CONTROL BOX COVER (1). Fig. 1.
2. Feed the 27" EXTENSION CABLES (2) through the top of
CONTROL BOX (3). Fig. 1a.
4
Fig. 1c
6
OR STANDARD BATTERY VERSION ONLY
F
3. Insert BATTERY (4) into BATTERY HOLDER (5),
make sure the shape of the BATTERY (4) follows the
shape of the BATTERY HOLDER (5) and terminal end
is inserted first. Fig. 1b.
-P2
CR
STANDARD
BATTERY
5a
PWRX
4. Insert the BATTERY CONNECTOR (5a) from the
Standard Battery or PWRX Battery Pack through side
GROMMET (6) as shown. Fig. 1c.
5. Connect SOLENOID CABLE (7) and BATTERY
CONNECTOR (5a) to 27" EXTENSION CABLES (2).
Place Standard Battery or PWRX Battery Pack into h
ousing. Fig. 1d.
Fig. 1d
5a
5a
6. Reinstall CONTROL BOX COVER (1). Tighten cover
screws firmly.
2
7
STANDARD
BATTERY
CAUTION: Use only American Standard supplied cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying
any components will void the warranty.
PWRX
5
M965652 Rev. 1.7 (10/16)
VERSION; Fig. 2
B AC
Fig. 2
• PLUG-IN
• HARDWARE
CAUTION
2
Disconnect AC power supply
before opening CONTOL BOX.
3
1
Note: For AC installation, make power supply connection
before mounting CONTROL BOX (3) to wall.
1. Remove CONTROL BOX COVER (1). Feed the
EXTENSION CABLES (2) from the Faucet through
the top of CONTROL BOX (3). Install CONNECTOR
LOCKING DEVICE (16). Fig. 2.
FOR AC PLUG-IN ONLY
2a. Insert POWER CORD (8) through POWER SUPPLY
GROMMET (9) Fig. 2a.
3a. Insert POWER CORD (8) through side GROMMET (6)
as shown. Connect it to the SINGLE AC ADAPTER (10).
Fig. 2a.
4a.Connect 27" EXTENSION CABLES (2) to SOLENOID
CABLE (7) and POWER CORD (8). Fig. 2a.
5a. Mount CONTROL BOX to wall. Reinstall CONTROL BOX
COVER (1). Tighten cover screws firmly.
6a. Plug AC POWER SUPPLY into wall outlet.
Fig. 2a
2
Fig. 2b
6
16
7
10
PLUG INTO
WALL OUTLET
9
8
2
FOR AC HARDWIRE ONLY
2b. Insert one end of the 10' EXTENSION (10a) through
POWER SUPPLY GROMMET (9). Fig. 2b.
3b. Insert 10' EXTENSION (10a) through side
GROMMET (6) as shown. Fig. 2b.
4b. Connect 10’ EXTENSION (10a) to single terminal of
SINGLE AC ADAPTER (11). Fig. 2b.
5b. Connect 27" EXTENSION CABLES (2) to SOLENOID
CABLE (7) and to the available terminal of the SINGLE
AC ADAPTER (11).
6b. Mount CONTROL BOX (3) to wall. Reinstall CONTROL
BOX COVER (1). Tighten cover screws firmly.
Contractor to supply ELECTRICAL BOX (12) and power
to POWER SUPPLY (13).
7b. Mount POWER SUPPLY (13) into ELECTRICAL
BOX (12). Connect White and Black connections to
POWER SUPPLY CONNECTIONS (14). Fig. 2c.
8b. Connect the10' EXTENSION (10b) to the POWER
SUPPLY CABLE (15). Fig. 2c.
2
7
11
10a
6
9
FROM ELECTRICAL BOX
WITH POWER SUPPLY
Fig. 2c
4" ELECTRICAL BOX
OR EQUIVALENT BY
OTHERS
12
10b
14
15
CAUTION: Use only American Standard supplied cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying
any components will void the warranty.
BLACK & WHITE
POWER
CONNECTIONS
6
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
M965652 Rev. 1.7 (10/16)
Fig. 3
Unit #2
Unit #1
Unit #3
Already installed
10 ft.
EXTENSION
CABLE
AC HARDWIRE
POWER SUPPLY
AC POWER
SUPPLY
OR
*MAXIMUM OF 15 UNITS PER
AC POWER SUPPLY.
10' MAXIMUM CABLE
LENGTH BETWEEN UNITS.
C MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the first unit’s Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 5).
For subsequent Units, refer to instructions below...
1. Remove COVERS from all CONTROL BOX (3).
2. Insert pervious unit’s 10’ EXTENSION (11a) through
gray GROMMET (5b) and connect to single terminal of
Y-ADAPTER (11).
3. Remove solid black plug grommet from left side of all
CONTROL BOX (3), and replace with GRAY
GROMMET (5b). (Supplied with each Faucet).
4. Feed 27" EXTENSION CABLES (2) through the top of
CONTROL BOX (3). Connect one 27" EXTENSION
CABLE (2) to the SOLENOID CABLE (7), and the other
to either of the two available terminals of the
Y-ADAPTER (11). Connect the current unit’s 10'
EXTENSION (10a) to available terminal of the
Y-ADAPTER (11).
5. Feed the other end of the 10 ft. EXTENSION (10b)
through the two GRAY GROMMETS (6a and 6b) and
connect to the single terminal of the next unit’s
Y-ADAPTER (11). Place Y-ADAPTER (11) into
CONTROL BOXT (3).
6. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7. Reinstall CONTROL BOX COVERS. Tighten cover
screws firmly.
Unit #2 Detail
Fig. 3a
3
6a
10a
2
11a
10b
2
6b
5b
11
5
7
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or
modifying any components will void the warranty.
7
M965652 Rev. 1.7 (10/16)
Fig 1
MAINTENANCE
A
T IO N
DETEC E
ZON
10
4
HAND WASH SENSOR OPERATION; Fig. 1
6
3
hen the Sensor detects a user, the water immediately starts
W
to flow. Water flow will stop 2 seconds after user is out of
sensor range. The off delay allows the user to comfortably
move his hands without the flow cycling on and off. As a
precaution, a safety timer will turn off the water after the
sensor has been blocked for 59 seconds. The water will stay
off until the blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50mm - 250mm)
Default: Set at Factory 6" (150mm)
5
B CHANGE SENSOR RANGE;
Fig. 2
(Factory set at 6") Fig. 2, 2a
1. Remove CONTROL BOX. Disconnect Power Supply (1),
then reconnect. Fig. 2.
2. While the SENSOR CONTROL LED (2) is blinking slowly,
place your hand 1 - 2 in. (30-50mm) in front of the sensor.
Fig. 2a.
3. When the LED stops blinking and stays “ON”, move your
hand to the desired position and hold in place until the LED
begins to blink again. Fig. 2a.
4. Once the SENSOR CONTROL LED (2) begins to blink
again, remove your hand from the detection zone. When the
flashing stops, the detection distance is set.
5. Reinstall CONTROL BOX COVERS (2). Tighten cover
screws firmly.
1
Fig. 2a
2 BLINKING
LED
2
C CLEAN FILTER ASSEMBLY; Fig. 3
CAUTION
UP TO 10" (250mm)
1" - 2" (30mm - 50mm)
BLINKING LED
Fig. 3
Before opening CONTROL BOX
disconnect AC power supply.
1. Remove CONTROL BOX COVER.
2. Close SUPPLY STOP (13) with 4mm Hex wrench.
Note: Activate sensor to keep water flowing out of
faucet while shutting off.
3. Unthread FILTER ASSEMBLY (6) using a 7/16" socket.
4. Pull out the FILTER ASSEMBLY (6), remove and clean
white debris cup and filter screen.
5. Install the FILTER ASSEMBLY (6) back in its place and
tighten with a 7/16" socket.
Caution: Do not over tighten.
6. Open SUPPLY STOP (13) with 4mm Hex wrench.
7. Reinstall CONTROL BOX COVER. Tighten cover
screws firmly.
7/16" SOCKET
6
WHITE
DEBRIS
CUP
13
•
• •••••• • •
•••••••• •••• •• • • •
•••••••• •••• •• •••• • • • •
••••••••••••••••••••••••••• • •
•
• • •••• • • • • •• • • • •
•••••••• ••••••• •••• •• ••• •
•••••••••••••••••••••••••••• •
• • •• •• • •• • •
• •• • • •
••
••• •
• •• • •••••••••••
• • • • • •••••
• • • • • •••••
• • • • • •••••
• • • • • •••••
• • • • • •••
• ••
FILTER
SCREEN
4mm HEX WRENCH
8
M965652 Rev. 1.7 (10/16)
D INSTALL / REPLACE THE BATTERY
Fig. 4
or PWRX; Fig. 4
CR-P2
2
1. Remove COVER from CONTROL BOX (1).
2. Disconnect BATTERY HOLDER (3) from 27"
EXTENSION CABLE (5).
3. Remove old BATTERY from Battery Holder (3). Install new
BATTERY (2) making sure the terminal side is inserted first
and shape of the battery follows the shape of the BATTERY
HOLDER (3).
4. To replace PWRX BATTERY PACK (4), unplug and replace
with new Power Pack.
5. Reconnect BATTERY HOLDER (3) to 27" EXTENSION
CABLE (5).
6. Reinstall CONTROL BOXT COVER. Tighten cover
screws firmly.
E CLEAN AND REMOVE THE AERATOR; Fig. 5
1. Remove AERATOR HOUSING (1) with KEY supplied with faucet.
2. Remove AERATOR (2) from HOUSING (1).
3. Clean the AERATOR SCREENS (3).
4. Clean with water. Reassemble and install into spout end.
Make sure black seal washer is in place..
9
1
5
STANDARD
BATTERY
6
3
4
PWRX
Fig.5
Fig.5
3
1
2
M965652 Rev. 1.7 (10/16)
F GENERAL CLEANING; Fig. 5
1. For general cleaning use a damp, soft cloth to clean the spout and the sensor.
Fig.6
2. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.
CAUTION
Do not scratch the sensor when cleaning. Avoid using
any abrasives or harsh detergents or chemicals.
Avoid using anything that may scratch the spout surface.
Never use polishing power, detergent or a nylon scrub brush.
They will damage the surface of the spout or Sensor.
FAQ’S
Q: How will I know if the battery needs to be replaced?
A: Valve will not open and sensor will continuously blink 2 times interrupted by a pause, for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly?
A: The filter assembly, flow regulator or areator/spray may be clogged. Check and clean. Refer to
Start-up/Maintenance, sections C, D and E.
Q: Why doesn’t water flow out of faucet when I’m within the sensor detection zone?
A: Battery may need replacement. If sensor continuously blinks 2 times interrupted by pause, replace battery
or call (844) CRT-TEAM / (844) 278-8326.Z
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging from 20-80 psi.
10
M965652 Rev. 1.7 (10/16)
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
ARE EXTERNAL SUPPLY
STOPS OPEN?
NO
OPEN EXTERNAL SUPPLY STOPS.
NO
OPEN INTERNAL SUPPLY STOP.
(HEX KEY NEEDED)
YES
CRITICALLY LOW BATTERY.
INSTALL NEW BATTERY.
YES
IS INTERNAL SUPPLY
STOP OPEN?
YES
REPEATED DOUBLE FLASH
ON SENSOR?
NO
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
1
2
NO
NO
1
2
DEAD BATTERY. INSTALL
NEW BATTERY. REPEAT.
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
YES
REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
NO
FULLY OPEN INTERNAL & EXTERNAL SUPPLY
STOPS BY TURNING COUNTER CLOCKWISE.
YES
REPLACE SOLENOID
LOW FLOW ISSUES
ARE INTERNAL & EXTERNAL SUPPLY
STOPS FULLY OPEN?
YES
LOW FLOW COULD BE CAUSED BY DEBRIS
IN THE FILTER ASSEMBLY, FLOW REGULATOR
OR AERATOR/SPRAY. REMOVE, CLEAN AND
INSERT BACK TO ORIGINAL POSITION.
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pro d uct nam es listed herein are tr ad em ar ks o f AS Am er ica, Inc . ©2016
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
11
M965652 Rev. 1.7 (10/16)
SELECTRONIC®
Innsbrook Lavatory
Proximity Faucet
MODEL NUMBERS
M922887-YYY0A
1.5 GPM AERATOR
066508-YYY0A
0.5 GPM AERATOR
M922286-0020A
0.35 GPM AERATOR
605X.202
605X.204
605X.205
M964909-0070A
SENSOR KIT
(ON-OFF)
PWRX Battery Pack
6053 – Series
M964155-0070A
SENSOR KIT
(METERING)
M950361-0070A
PWRX BATTERY PACK
CR-P2 Lithium Battery
6055 – Series
044912-0070A
MOUNTING NUT
A923672-0070A
FAUCET
SUPPLY HOSE
M923115-0070A
PUTTY PLATE
A923654-0070A
BATTERY 6V CR-P2
M964940-0070A
CONTROL BOX ASSEMBLY
(POWER SUPPLY NOT INCLUDED
AND MUST BE ORDERED SEPARATELY)
M950514-0070A
BATTERY HOLDER
Plug-In AC
Power Kit
PK00.PAC
M950338-0070A
POWER SUPPLY
M950360-0070A
CONNECTOR
LOCKING DEVICE
A913202-0070A
WASHER
A924162-0070A
SUPPLY HOSE
M950510-0070A
27" EXTENSION CABLE
M950399-0070A
SINGLE AC ADAPTER
Hard-Wired AC
Power Kit
PK00.HAC
M950511-0070A
10' EXTENSION
M950520-0070A
POWER SUPPLY
M950360-0070A
CONNECTOR
LOCKING DEVICE
M950399-0070A
SINGLE AC
ADAPTER
Multi-AC
Power Kit
PK00.MAC
M964410-0070A
SOLENOID ASSEMBLY
M950511-0070A
10' EXTENSION
M950512-0070A
MULTI-AC ADAPTER
A950507-0070A
FILTER ASSEMBLY
A950509-0070A
SUPPLY STOP
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Replace the "YYY" with
appropriate finish code
CHROME
002
Pro d uct nam es listed herein are tr ad em ar ks o f AS Am er ica, I nc . ©2016
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
12
M965652 Rev. 1.7 (10/16)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising