12 Volt Single Output Charger Waterproof 800
Waterproof 800
12 Volt Single Output Charger
Mounting
Holes
Input Voltage & Frequency
100 to 240 VAC, 50/60 Hz
DC OUTPUT (Nominal voltage & current values)
Output Current
Output Voltage
0.800 Amps
12 Volts
Charger Output Voltage Amplitudes throughout the entire charge
algorithm, including absorption and float maintenance, are
consistent with the optimum charging recommendations of the
major lead-acid battery manufacturers.
Fused
Output
Accessories
Rings & Clips
The best way to eliminate sulfation is to prevent it!
The Battery Tender® Plus will fully charge a battery and maintain it at the
proper storage voltage without the damaging effects caused by trickle
chargers (especially sulfation).
"SUPER SMART™" TECHNOLOGY
3-STEP CHARGING (Initialization, Bulk, Float)
SPARK PROOF
SHORT CIRCUIT PROTECTED
REVERSE POLARITY PROTECTED
WATERPROOF, IP 67 Rating
CONVENIENT MOUNTING HOLES (Hardware Included)
3 YEAR WARRANTY !! (Material & Workmanship Only)
ORDERING INFORMATION
Deltran PART NO. DESCRIPTION
022-0150-DL-WH 12 Volt 0.800 Amp Output
Ask customer service about International configurations.
081-0148-25
081-0148-12
TECHNICAL SPECIFICATIONS SUMMARY
Optional 25 ft. 2-pin Output Extension Leads
Optional 12.5 ft. 2-pin Output Extension Leads
Maximum Operating Temperature
Charger Case Dimensions
50 °C Typical
4.2 in(107 mm)L x 2.75 in(70 mm)W x 1.4 in(36 mm)H
Shipping Weight with Cable Accessories
3.0 lbs (1.4 kg)
Note: The Battery Tender® Waterproof 800 is designed to accommodate the
demanding charging requirements of high quality lead-acid batteries and should
safely charge all lead acid battery types. Always check with the battery
manufacturer to get the most complete charging recommendations that are
consistent with your application.
Declaration of Conformity: These battery charger products carry the CE mark.
They comply with standards comprising the following groups: EC Low Voltage
Directive and EC Council Directive on Electromagnetic Compatibility.
Design Conformance & Revision: All Deltran charger products are 100%
inspected and electrically tested prior to shipment. All Deltran battery
charger designs are proprietary and subject to change without notice.
Deltran makes no specific claims nor does it either make or imply any
specific guarantee or warranty with respect to either the physical
configuration or performance of any of the battery charger products listed
herein, including suitability for purpose or merchantability.
For inquiries and orders, contact:
MICROBATTERY.COM
7350 NW 35th Terrace, Miami, Florida 33122
Customer Service: 1-866-999-2355
Phone: 1-305-371-9200 Fax: 1-305-371-9400
www.microbattery.com
Battery
Terminal
Voltage
(VOLTS)
General 3 Step Charging:
Initialization, Bulk, Storage (Float):
Charger Current Limit
(Constant Current)
Battery
Charging
Current
(AMPS)
Float / Maintenance Volts
¾ AMBER - When the LED is Amber, the battery charger is in
the process of fully charging the battery. In order to properly charge
large capacity batteries, the charger may remain in this mode for
several hours or even days.
Float Charge:
Constant Voltage,
Maintenance Current
Float / Maintenance Amps
0
0
0
There is a single LED that appears to have 2 colors.
¾ THE LED IS OFF - This is an abnormal condition. First
check that the AC power is plugged in. Then check that the charger
DC output rings or clips are properly connected to the battery. Then
check the fuses in the DC output cables. Finally, check the AC
receptacle by plugging another small appliance, like a lamp.
Bulk Charge Amps
Bulk Charge:
Constant Current,
Voltage Increases
INDICATOR LIGHT OPERATION
Charging Time (Hours)
Step 1) Initialization: LED is Amber: Monitor Circuit verifies
appropriate battery voltage levels and good electrical continuity between
the battery and the charger DC output. If the AC power is connected and
the LED remains OFF, check the DC connections to the battery.
Step 2) Bulk Charge: LED is Amber: Constant Current at Full Power.
Step 3) Float / Maintenance, Storage Charge: LED is Green. Constant
Voltage at Float / Maintenance level. Keeps battery fully charged and
maintains high specific gravity. Float charge continues indefinitely, or
until you unplug the charger from AC power, or a momentary AC power
outage causes the charge program to reset.
Note: Three things determine how long it takes to recharge a battery.
First is the size of the battery measured in Amp-Hours (Ah) or Reserve
Capacity Minutes. Second is how often and how deeply you discharge
the battery. Third is the charger DC continuous current output rating (not
just the maximum current). A 1.0 amp constant current charger will take
at least 100 hours to recharge a dead 100 Ah battery.
¾ GREEN - When the LED is Green, the battery battery is
completely charged and the charger is in the float / maintenance,
storage mode. The charger will maintain the battery at full charge.
¾ LED ALTERNATES AMBER & GREEN, or APPEARS
TO BE ORANGE or BROWN - This is abnormal and most likely
indicates that the battery is sulfated. The Orange or Brown color
results from rapid switching between Amber and Green.
APPLICATION INFORMATION
Always operate the charger in a well ventilated area
If the indicator light does not come on after you plug in the
AC cord, follow the steps in the LED Operation section.
If the indicator light turns green too soon, check the battery
and the output connections from the charger. Note: this is a
normal indication if the battery was nearly fully charged and only
needed to be topped off.
It may take a long time for the LED to turn green when
charging a large battery.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising