А.2.1.1 Wiring to the V1000R Series Controller
The C50 is mtended to be mounted indoors on the secure side of the controlled
door. To prevent RS485 multi-drop troubleshooting problems, the C50
communications wiring is isolated through an RS485 Hub. You can only connect
one C50 to each port on the RS485 Hub. The RS485 ports on both the RS485
Hub and the C50 board have built-in line termination resistors.
The RS485 Hubs are located in the wiring closet with the V1000R series
controller. Each RS485 Hub can be connected to a maximum of 8 C50 boards. A
maximum of 4 RS485 Hubs can be daisy-chained to a single V1000R series
controller to support up to 32 C50 boards, Since the RS485 wiring between the
V1000R series controller and the RS485 Hub is limited to 50-ft. in length, no
line termination resistors are required. (See Figure A-5.)
Power to the RS485 Hubs should be supplied from a battery-backed 12VDC
power supply that is usually located in the wiring closet with the RS485 Hubs,
Since the RS485 Hubs do not have a terminal strip for connection to the 12VDC
power, you can cut off and splice to a section of the cable from the included
12VDC power supply.
NOTE
Make sure that you observe the polarity. The center pin of the
barrel connector is negative.
A-13
€ 2005-2009 The CBORD Group, Inc. All rights reserved,
TP-830137 (Ed. €)
Table A-4 Maximum Power Cable Lengths for VIP Door, A2005, and
IR Biometric HandKey Il Readers
VIP Door A2005 HandKey ll Readers Cable
Readers Description
150-й. (24\/) 150-й. (12V) 30-8. (12V) 22 AWG wire
120-ft. (24V)
240-ft, (24V) 240-ft. (12V) 50-ft. (12V) 20 AWG wire
200-ft. (24V)
375-ft. (24V) 375-ft. (12V) 80-ft. (12V) 18 AWG wire
320-ft. (24V)
600-ft. (24V) 600-ft. (12V) 125-ft. (12V) 16 AWG wire
480-ft. (24V)
A.2 Wiring Specifications for Squadron Boards
This section covers the wirmg specifications for the Squadron boards. Refer to
Table A-2 for the maximum distance to the card readers, Refer to Section 3.9
for guidance mounting Squadron boards and Section 3,5 for internal cabling
guidance.
A.2.1 Squadron 1-Door Connector (C50)
The Squadron 1-Door Connector (C50) is installed indoors on the secure side
of the controlled door, with one card reader on the uncontrolled side of the
door. The following sections describe how to wire a C50 to the V1000R series
controller and how to wire a card reader to the C50:
* Appendix A.2.1.1: Wiring to the Vi000R Series Controller
* Appendix A.2.1.2: Wiring to the Card Reader
A-12
© 2005-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
Table A-3 Power, Door Strike, and Magnetic Lock Cabling Requirements
Max. Cable Length | Max. Cable Length for | Max. Cable Length Cable Non-plenum Plenum Cable
for 12V or 24V 12V or 24V Loads up for 12V or 24V Loads | Description Cable (Choose One)
Loads up to 1.2 A to 600 mA up to 300 mA (Choose One)
25-ft. (12V) 50-ft. (12V) 100-ft. (12V) 22 AWG wire Alpha 2401C Alpha 58411
50-ft. (24V) 100-ft. (24V) 200-ft. (24V) Belden 9462 Belden 82761
Belden 8761 Belden 88761
Carol C2518 Carol E2102S
or equivalent or equivalent
40-ft. (12V) 80-ft. (12V) 160-ft. (12V) 20 AWG wire Alpha 2411C Alpha 58421
80-ft. (24V) 160-ft. (24V) 320-ft. (24V) Belden 5400FE | Belden 83602
or equivalent or equivalent
65-ft. (12V) 130-ft. (12V) 260-ft. (12V) 18 AWG wire Alpha 2421C Alpha 58431
130-ft. (24V) 260-ft (24V) 520-ft. (24V) Belden 5300FE | Belden 83652
or equivalent or equivalent
100-ft. (12V) 200-ft. (12V) 400-ft. (12V) 16 AWG wire Alpha 2432C Alpha 58142
200-ft. (24V) 400-ft. (24V) 800-ft. (24V) Belden 5220FL | Belden 83702
or equivalent or equivalent
A2005 and IR Biometric HandKey Il Reader Power Cable
Requirements
Table A-4 defines the maximum power cable length for one A2005 or HandKey
II reader from a remote power supply. If you are powering more than one
A2005 or HandKey II reader at the end of one cable, you must reduce the
distances in Table A-4 as follows:
1 A2005 or HandKey II reader = 100%
* 2 A2005 or HandKey II readers = 50%
* 3 A2005 or HandKey II readers = 33%
* 4 A2005 or HandKey II readers = 25%
* 5 A2005 or HandKey II readers = 20%
* 6 A2005 or HandKey II readers = 17%
© 2005-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
A-11
Table A-2 Squadron Cabling Requirements (continued)
Cable | Application Non-Plenum Plenum Cable Cable Description Maximum Length
Type Cable (Choose (Choose One)
One)
CB-12 | RS485 Network, Alpha 5491C Alpha 58401 24 AWG wire, shielded Keep within the
V1000R to V100s, with drain, stranded, 1 wiring closet.
V200s, V300s, Belden 9841 Belden 89841 twisted pair
Wireless™ RS485 The RS485 wiring
PIM, V1000R to Carol C0740 or equivalent must be kept within
RS485 Hub the wiring closet in
or equivalent order to maximize its
reliability and integrity.
A given V1000 and all
attached V100, V200,
and V300 panels and
RS485 Hubs must be
kept within the same
wiring closet for the
same reason.
CB-13 | RS485 Network, Alpha 5492C Alpha 58802 24 AWG wire, shielded 3,000-ft.
V1000R to HK-II, with drain, stranded, 2
A2005, PIB to VIP | Belden 1419A Belden 6641FC twisted pair
Door, RS485 Hub
to C50, RS485 Hub | or equivalent or equivalent
to VIP5100/Direct
Lock
CB-14 | Ethernet Cable, N/A N/A Cat-5 or higher Ethernet | 300-ft.
V1000 or V2000 to Cable
Hub
CB-15 | 12V Door Strikes to See Table A-3. See Table A-3. See Table A-3. N/A
V100 or V2000
CB-01 | CBORD A1005 Alpha 1298C Alpha 58118 22 AWG, shielded 200-ft.
Magnetic Stripe with drain, stranded,
Reader Belden 5506FE Belden 6506FE 8-conductors The A1005 requires
1K, 1/4W resistors
Carol C0764 Carol E2108S between Data-0 and
ground and between
or equivalent or equivalent Data-1 and ground.
Resistors are shipped
with the A1005
Pigtail Assembly
(GR-675-1968-000).
CB-17 | CBORD A1005 Alpha 5388C Alpha (N/A) 18 AWG wire, shielded 500-ft.
Magnetic Stripe with drain, stranded,
Reader Belden 5306FE Belden 6306FE 8-conductors The A1005 requires
1K, 1/4W resistors
Carol E2038S Carol E2208S between Data-0 and
ground and between
or equivalent or equivalent Data-1 and ground.
Resistors are shipped
with the A1005
Pigtail Assembly
(GR-675-1968-000).
A-10
© 2005-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
Table A-2 Squadron Cabling Requirements (continued)
Cable | Application Non-Plenum Plenum Cable Cable Description Maximum Length
Type Cable (Choose (Choose One)
One)
CB-01 | Generic Magnetic | Alpha1298C Alpha 58118 22 AWG wire, shielded | 50-ft.
Stripe Reader with with drain, stranded,
TTL Clock/Data Belden 5506FE Belden 6506 FE 8-conductors
Outputs to C50,
E400, V100, and Carol C0764 Carol E2108S
V2000
or equivalent or equivalent
CB-01 | Wireless™ 2-Door | Alpha 1298C Alpha 58118 22 AWG wire, shielded 50-ft.
PIM to V100, with drain, stranded,
V2000 - signals Belden 5506FE Belden 6506FE 8-conductors
Carol C0764 Carol E2108S
or equivalent or equivalent
CB-08 | Wireless™2-Door Alpha 2401C Alpha 58411 22 AWG wire, shielded | 50-ft.
PIM to V100, with drain, stranded 1
V2000 - power Belden 9462 Belden 82761 twisted pair
Belden 8761 Belden 88761
Carol C2518 Carol E2102S
or equivalent or equivalent
CB-01 | V100 to PIB Alpha 1298C Alpha 58118 22 AWG wire, shielded 50-ft. (two lengths)
with drain, stranded,
Belden 5506FE Belden 6506FE 8-conductors
Carol C0764 Carol E2108S
or equivalent or equivalent
CB-08 | Alarm Points to V100, | Alpha 2401C Alpha 58411 22 AWG wire, shielded 3,000-ft.
V200, V2000 with drain, stranded, 1
Belden 9462 Belden 82761 twisted pair
Belden 8761 Belden 88761
Carol C2518 Carol E2102S
or equivalent or equivalent
CB-08 | Egress switches to Alpha 2401C Alpha 58411 22 AWG wire, shielded 1,000-ft.
V100, V2000 with drain, stranded, 1
Belden 9462 Belden 82761 twisted pair
Belden 8761 Belden 88761
Carol C2518 Carol E2102S
or equivalent or equivalent
© 2005-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
A-9
A.1.3 Squadron Cabling Requirements
The following tables outline the Squadron cabling requirements.
NOTE
The Squadron cabling requirements have been suggested
for your convenience. You must verify that the cables
selected are suitable for your application and that they
meet local building and safety codes.
Wiegand readers include ProxPoint Plus, ProxPro,
ProxPros with PIN Pad (standard connection without
tamper), MiniProx, MaxiProx, iICLASS R10, and iCLASS
R40.
Table A-2 Squadron Cabling Requirements
Cable | Application Non-Plenum Plenum Cable Cable Description Maximum Length
Type Cable (Choose (Choose One)
One)
CB-01 Prox or ¡CLASS Alpha 1298C Alpha 58118 22 AWG wire, shielded 500-ft.
Reader with with drain, stranded,
Wiegand Outputs to | Belden 5506FE Belden 6506FE 8-conductors
C50, E400, V100,
V2000 Carol C0764 Carol E2108S
or equivalent or equivalent
CB-03 | Mercury MR-5 Alpha 1296C Alpha 58116 22 AWG wire, shielded 200-ft.
Magstripe Card with drain, stranded,
Reader, Mercury Belden 5504FE Belden 6504FE 6-conductors min.
BR-20 Magstripe
Card Reader, Carol C0763 Carol C3311
HPS Combination
Card Reader, or or equivalent or equivalent
Dorado Magnetic
Stripe Reader with
Wiegand Outputs to
C50, E400, V100,
and V2000
CB-04 | Mercury MR-5 Alpha 5386C Alpha 58136 18 AWG wire, shielded 500-ft.
Magstripe Card with drain, stranded,
Reader, Mercury Belden 5304FE Belden 6304FE 6-conductors min.
BR-20 Magstripe
Card Reader, Carol E2036S Carol C3166
HPS Combination
Card Reader, or or equivalent or equivalent
Dorado Magnetic
Stripe Reader with
Wiegand Outputs to
C50, E400, V100,
and V2000
A-8
© 2005-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
Tabie A-4 Maximum Power Cable Lengths for VIP Door, A2005, and
IR Biometric HandKey ll Readers
VIP Door A2005 НапаКеу Н Readers Cabie
Readers Description
150-ft. (24V) 150-ft. (12V) 30-ft. (12V) 22 AWG wire
120-ft. (24V)
240-ft. (24V) 240-1. (12V) 50-ft. (12V) 20 AWG wire
200-ft. (24V)
375-ft. (24V) 375-ft, (12V) 80-ft. (12V) 18 AWG wire
320-ft. (24V)
600-ft. (24V) 600-ft. (12V) 125-ft. (12V) 16 AWG wire
480-ft. (24V)
A.2 Wiring Specifications for Squadron Boards
This section covers the wiring specifications for the Squadron boards, Refer to
Table A-2 for the maximum distance to the card readers. Refer to Section 3.9
for guidance mounting Squadron boards and Section 3.5 for internal cabling
guidance.
A.2.1 Squadron 1-Door Connector (C50)
The Squadron 1-Door Connector (C50) 1s installed indoors on the secure side
of the controlled door, with one card reader on the uncontrolled side of the
door. The following sections describe how to wire a C50 to the V1000R series
controller and how to wire a card reader to the C50:
* Appendix A.2.1.1: Wiring to the V 1000R Series Controller
* Appendix A.2.1.2: Wiring to the Card Reader
A-12
© 2003-2009 The CBORD Group, Inc. All rights reserved.
TP-830137 (Ed. C)
1.7 Definitions
Table 1-3 describes the Squadron and wireless definitions:
Table 1-3 Definitions
Name
Description
Squadron Board
Squadron controllers and door connectors.
IRL
Integrated Reader Lock CRL).
PIB The Panel Interface Board (PIB) handles ali communications with the original VIP door lock.
PIM The Panel interface Module (PIM) enables access contro! boards to interface with WAPMs.
PIME Panel Interface Module Extender {PIME).
WAPM The Wireless Access Point Module (WAPM) is the door or the reader where the user presents
the card.
WAS All devices together make up the Wireless Access System (WAS).
WPIM The Wireless Panel Interface Module (WPM) is what the WAPMSs talk to on the wireless link.
WPR The Wireless Portable Reader (WPR) provides access control anywhere within 1000 feet
of the control panel.
WRI The Wireless Reader interface (WRI) layout covers traditional door hardware without adding
cost and complexity from wiring installations.
WSM Wireless Status Monitor (WSM).