The KRD9 Series microcontroller timing circuit provides excellent repeat accuracy and stability. Cost effective
approach for OEM applications that require small size, isolation, reliability, and long life.
Operation- Retriggerable Single Shot
Compact Time Delay Relay
Microcontroller Circuitry, +/0.5% Repeat Accuracy
Isolated 10 A SPDT Output Contacts
Onboard or External
Adjustment or Fixed Time
Delay
Delays from 100 ms ...
1000 m in 6 Ranges
Input Voltages from 12 ...
230 V in 5 Ranges
Function
Function Type A (Output Initially De-energized):
Input voltage must be applied prior to and during
timing. When the initiate switch is closed, (momentary
or maintained) the output energizes and the time delay
starts. On completion of the delay, the output deenergizes. The unit will time out if S1 remains in the
open or closed position for the full time delay. Reclosing
the initiate switch resets the time delay and restarts
timing; the output remains energized. The output will
not energize if the initiate switch is closed when input
voltage is applied.
Function Type B (Output Initially Energized): Upon
application of input voltage, the output energizes and
the time delay starts. At the end of the time delay,
the load de-energizes. The unit will time out if S1
remains in the open or closed position for the full time
delay. Closing (re-closing) the initiate switch resets
the time delay and restarts timing; the output remains
energized.
Reset: The time delay and the output are reset when
input voltage is removed.
Motion Detector/
Retriggerable Single Shot
De-energized
Motion Detector/
Retriggerable Single Shot
Energized
Connection
V = Voltage S1 = Initiate Switch
R = Reset
TD = Time Delay
t = Incomplete Time Delay
NO = Normally Open NC = Normally Closed
Approvals:
Accessories
B
A
External adjust
potentiometer
P/Ns:
P1004-95 (fig A)
P1004-95-X (fig B)
Versa-knob
P/N: P0700-7
Mounting bracket
P/N: P1023-6
Female quick
connect
P/Ns:
P1015-64 (AWG 14/16)
P1015-13 (AWG 10/12)
C = Common, Transfer Contact
UTL = Untimed Load
A knob is supplied for adjustable units, or RT terminals 4
& 5 for external adjust. See external adjustment vs time
delay chart. The untimed load is optional. Dashed lines
are internal connections. Relay contacts are isolated.
Ordering Table
←
→
DIN rail adaptor
P/N: P1023-20
See accessory pages for
specifications.
X
Input
–1 - 12 V DC
–2 - 24 V AC/DC
–4 - 120 V AC
–5 - 110 V DC
–6 - 230 V AC
X
Adjustment
–1 - Fixed
–2 - Onboard
Adjustment
–3 - External
Adjustment
X
Time Delay *
–0 - 0.1 ... 10 s
–1 - 1 ... 100 s
–2 - 10 ... 1000 s
–3 - 0.1 ... 10 m
–4 - 1 ... 100 m
–5 - 10 ... 1000 m
X
Function Type
–A - De-energized
–B - Energized
* If Fixed Delay is selected,
insert delay [0.1 … 1000]
followed by (S) sec. or
(M) min.
Example P/N: KRD9421A = 120 V AC; Onboard adjust from 1 to 100 seconds, De-energized Function
KRD9610.5SB = 230 V AC, Fixed at 0.5 seconds, Energized Function
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
08.15.06
DIN rail P/Ns:
017322005 (Steel)
C103PM (Al)
KRD9
Series
KRD9Gen
Quick connect to
screw adaptor
P/N: P1015-18
De
Motion Detector - Retriggerable Single Shot
KRD9 Digi-Timer
Time Delay Relay
d
tim icat
er ed
s
Technical Data
Time Delay
Type
Microcontroller based with watchdog circuitry
Range
0.1 s ... 1000 m in 6 adjustable ranges or fixed
Repeat Accuracy
+/-0.5% or 20 ms, whichever is greater
Tolerance (Factory Calibration)
≤ +/-5%
Reset Time
≤ 150 ms
Initiate Time
≤ 40 ms; ≤ 750 operations per minute
Time Delay vs. Temperature & Voltage
≤ +/-5%
Input
Voltage
12, 24 or 110 V DC; 24, 120 or 230 V AC
Tolerance
12 V DC & 24 V DC/AC
-15% ... +20%
110 VDC, 120 or 230 V AC
-20% ... +10%
AC Line Frequency / DC Ripple
50 ... 60 Hz / ≤ 10%
Power Consumption
AC ≤ 2 VA; DC ≤ 2 W
Output
Type
Isolated relay contacts
Form
Single pole double throw (SPDT)
Rating (at 40°C)
10 A resistive at 125 V AC
5 A resistive at 230 V AC & 28 V DC; 1/4 hp at 125 V AC;
Max. Switching Voltage
250 V AC
Life (Operations)
Mechanical -- 1 x 107 ;Electrical -- 1 x 105
Protection
Circuitry
Encapsulated
Isolation Voltage
≥ 1500 V RMS input to output
Insulation Resistance
≥ 100 MΩ
Polarity
DC units are reversed polarity protected
Mechanical
Mounting
Surface mount with one #10 (M5 x 0.8) screw
Package
2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination
0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage Temperature -40°C ... +60°C/-40°C ... +85°C
Humidity
95% relative, non-condensing
Weight
≅ 2.6 oz (74 g)
External Resistance vs Time Delay
Output Current / Ambient Temp.
Mechanical View
External Adjust Detail
Replaces Knobs if Ordered
Inches (Millimeters)
KRD9Gen
08.15.06
Phone: 800.894.0412
- Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising