TempTale®4 USB Multi-Alarm Monitor

TempTale®4 USB Multi-Alarm Monitor
Millions Depend on the Integrity of Your Product.
Sensitech’s Mission is to Ensure that Integrity.
The Tools That Turn Information Into Power
TempTale®4 USB
Multi-Alarm Monitor
Instructions For Use
TempTale Manager®
Desktop Software
Data Management Services
RF Monitoring
TempTale®4 Monitor
TempTale®4 USB Monitor
TagAlert® Indicator
For more information, contact our client services
group at 800-843-8367.
© 2014 Sensitech, Inc. All Rights Reserved.
T83001870 Rev. C 07/09/14
Sensitech Inc. • 800 Cummings Center, Suite 258X • Beverly, MA 01915
1-800-843-8367 • +1-978-927-7033 • Fax 978-921-2112 • www.sensitech.com
All TempTale®4 USB Multi-Alarm (MA) monitors are programmed with
a custom start-up delay, measurement interval and time-temperature alarm
settings that have been pre-determined by the customer.
Starting a TempTale®4 USB MA Monitor
•
•
Press the Start button (1 – 3 seconds) until the “Sunshine” icon
appears in the upper left corner of the display.
The TempTale4 USB MA will now begin to record data after the
pre-programmed start-up delay period has passed.
•
•
Recover the TempTale4 USB MA monitor and press the red Stop button (1 – 3 seconds) to
manually stop the unit. NOTE: If the monitor is not stopped manually, the TempTale4 USB
MA will continue to record data until the monitor is plugged into a USB port on the computer
or until the pre-programmed trip length is exceeded.
Verify the “Stop” icon is visible on the display.
Retrieving TempTale4 USB MA Monitor Reports and Data Files
To Mark an Important Event (“Date Stamp”)
•
•
•
Receiving a TempTale4 USB MA Monitor
The TempTale4 USB MA monitors provide an option to “Date Stamp”
or mark an important event at any time during the recording cycle. This mark is displayed as
an arrow when viewing the Graph and shown in bold italics when viewing the Tabular data. To set a marked data point while the monitor is recording, press and release the “Start”
button. The “Arrow” icon will appear temporarily in the lower left corner and the trip
summary data will appear on the display.
Press and release the Start button to step through the trip summary data. Data appears
as follows:
1. Time remaining/time elapsed before alarm triggers (configurable option)
2. Average temperature
3. Highest temperature recorded
4. Lowest temperature recorded
5. Alarm number(s) that triggered (configurable option)
6. Current Temp Reading (Last Temp Recorded configurable option)
•
•
Pull out the USB connector cable from the side of theTempTale4 USB MA
monitor and insert the plug into a USB port on the computer. The monitor will
automatically begin creating the Adobe® PDF report and Sensitech
.TTV data file within the monitor.
After the LED on the face of the monitor glows solid
green, the monitor has completed the report and data file
generation. The files are now accessible as files on a
“removable storage device” as shown below.
Note: Do not remove the plug from the USB port on the computer
until the LED on the face of the monitor glows solid green. Alarming
When the TempTale4 USB MA is exposed to temperatures that meet or exceed the allowable
pre-programmed time threshold, an “Alarm bell” or “X” (depending on which Alarm display
option is configured) will appear at the top of the LCD window. Stopping a TempTale4USB Monitor
Press and hold (1 to 3 seconds) the Stop button until the “Stop” icon appears in the upper
right corner of the display. Inserting the USB plug into a USB port on the computer will also
stop the monitor.
Displayed Information
Alarm number triggered
Recording
Marked point
Alarm icon
Stopped recording
Time remaining
MIN(s)
Managing and Viewing TempTale4 USB Monitor Files
•
•
•
If the computer has Adobe PDF compatible reader software installed, the PDF report file
containing the monitor information, summary statistics, and time-temperature data graph,
can be opened and viewed by double clicking on the .PDF file icon. If the computer has Sensitech’s TempTale Manager® Desktop Software installed, the .TTV
data file containing the monitor information and time-temperature data, can be opened and
accessed by double clicking on the .TTV file icon.
Both the PDF and .TTV files can be moved, copied, saved and/or attached to email as
allowed by the computer operating system.