installation - Premier Faucet

installation - Premier Faucet
INSTALLATION
Brand Tub & Shower Faucets
Tools:
Adjustable wrench
Pipe tape
Pipe wrench
Groove joint pliers
Basin wrench
screwdriver
Plumber's putty
Cleaning:
Model Number: 120091 &120092 & 120093 &120094
To maintain and protect the fine luster of all products .clean with a softdamp cloth
only .DO NOT USE detergents or cleanser as they may harm the protective finish.
INSTALLATION STEPS: Tub & Shower faucets
1. SHUT OFF WATER SUPPLY.
1 1/4" Dia
30"
Shower Only
48"
Tub&Shower
6" Dia
48"
Shower Only
8" Min.
30"
Tub&Shower
1 1/4" Dia
Verify that the hole sizes and positions of
holes in the wall are correct.
Recommended component measurements.
A.Shower and / or spout outlet hole:
1-1/4" diameter.
B.Valve access hole: 6 inch diameter.
C. Recommended valve depth to finished
wall: 2" min. to 2-1/2"max.
Be sure that the black template plate's surface is flush
with the finished exterior surface of the wall. Be sure to
position the valve body correctly in wall. "UP" marking
up. The 8" Minimum from the valve body to the tub
spout is required for proper operation.
2A
2B
2B
Wrap plumber's tape around pipe threads in a
clockwise direction. Connect water supplies to left
(hot) and right (cold) valve body inlets. Connect
shower outlet pipe (2B) and tub outlet pipe (2C) to
valve body . Connect Pipe Elbow (2A) (not
included) to the end of the pipe.
2C
2b. SHOWER ONLY SUPPLY CONNECTION LAYOUT
2A
2a. SUPPLY CONNECTION LAYOUT
3. FOR SHOWER ARM INSTALLATION.
3A
Wrap plumber's tape around pipe threads in a
clockwise direction.
Connect water supplies to left (hot) and right (cold)
valve body inlets.
Connect Shower Outlet Pipe (2B) to valve body. Plug
bottom outlet (2D) with plug (2E). Connect Pipe
Elbow (2A) (not included) to the end of the pipe.
Insert the long end of the shower arm (3B)
through the flange (3A) then wrap plumber's
tape to both sides of shower arm. Screw long
end of the shower arm into pipe elbow inside
the wall.
3B
2D
2E
5. FOR TUB SPOUT INSTALLATION
4. FLUSHING
4A
4B
For Tub and Shower Combinations:
Turn on Hot and Cold water supply lines
allowing water to flow from tub spout outlet (4B)
until all foreign matter has cleared the line.
For Shower Only Combinations:
Turn on Hot and Cold water supply lines
allowing water to flow from shower outlet (4A)
until all foreign matter has cleared the line.
Pressure must be approximately equal on both
Hot and Cold sides for valve to function
properly.
Install tub spout. Thread spout onto threaded
connection clockwise until the spout becomes
flush with the finished wall.
Thread sealant may be required depending on
your installation method. All thread sealants
may be found at your local hardware store.
6. Before installing escutcheon, remove the plastic
7. Place handle on valve stem and turn handle to
cap from plaster guard by twisting cap in a
clockwise direction. Remove the screw from the
inverter.
full on mixed position. Turn on hot and cold
water lines to full open for one minute each.
Check for leakage. Shut off water at faucet.
Remove the handle.
7. ADJUSTING WATER TEMPERATURE
8. Install escutcheon (8A) onto valve and then insert
screws (8B) to attach to valve body. Insert screw
(8C) into inverter. Place handle seat (8D) onto the
valve and secure with set screw (8E). Install handle
assembly (8F). Attach shower (8G) to shower
flange.
8G
8A
colder
8B
8D
8E
8C
hotter
rotational limit stop
8F
stop on cartridge
Turn on water so that cold water is as cold as it will
get and hot water is as hot as it will get. Remove
the Rotational Limit Stop from the valve by sliding
it off the stem. Place handle back on stem and
rotate fully counterclockwise to the hottest position.
Place a thermometer in a plastic tumbler and hold
in the water stream. If the water temperature is
above 120° F, the Rotational Limit Stop must be
rotated counterclockwise to decrease temperature.
Reinstall the stop by sliding it back on to the stem
before reinstalling the handle.
MAKE SURE COLD WATER FLOWS FROM THE
VALVE FIRST.
MAKE SURE WATER (AT THE HOTTEST FLOW)
DOES NOT EXCEED THE TEMPERATURE LIMIT
ALLOWED BY YOUR PLUMBING CODES (120° F
OR 110° F).
120091 &120092 & 120093 &120094
Parts List
13
14
15
10
8
11
9
12
7
16
6
5
4
3
2
1
MODEL NO.120091
PART DESCRIPTION
PART NO.
Handle
247
O-ring
259
20
Set Screw
280
Handle Seat
994692
Handle Adapter Kit
994442
Screws
281
Escutcheon
283
Sleeve
282
O-ring
994695
10 Cartridge
994722
11 Integral Stop
12 Plug
284
285
13 Shower Flange
286
14 Shower Arm
287
15 Shower Head
NO.
1
2
3
4
5
6
7
8
9
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MODEL NO.120092
PART DESCRIPTION
PART NO.
Handle
255
O-ring
259
20
Set Screw
295
Handle Seat
994692
Handle Adapter Kit
994442
Screws
296
Escutcheon
297
Sleeve
282
O-ring
994695
10 Cartridge
994722
11 Integral Stop
12 Plug
284
298
13 Shower Flange
299
14 Shower Arm
300
15 Shower Head
NO.
1
2
3
4
5
6
7
8
9
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MODEL NO.120093
PART DESCRIPTION
PART NO.
Handle
247
O-ring
259
20
Set Screw
280
Handle Seat
994692
Handle Adapter Kit
994442
Screws
281
Escutcheon
283
Sleeve
282
O-ring
994695
10 Cartridge
994722
11 Integral Stop
12 Plug
284
285
13 Shower Flange
286
14 Shower Arm
287
15 Shower Head
288
16 Spout
NO.
1
2
3
4
5
6
7
8
9
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MODEL NO.120094
PART DESCRIPTION
PART NO.
Handle
255
O-ring
259
20
Set Screw
295
Handle Seat
994692
Handle Adapter Kit
994442
Screws
296
Escutcheon
297
Sleeve
282
O-ring
994695
10 Cartridge
994722
11 Integral Stop
12 Plug
284
298
13 Shower Flange
299
14 Shower Arm
300
15 Shower Head
301
16 Spout
NO.
1
2
3
4
5
6
7
8
9
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising