MAGIC POWER TECHNOLOGY MPM-U650 series Preliminary Specification Preliminary SPECIFICATION For SWITCHING POWER SUPPLY M/N: MPM-U650 series Revision Index 2016. Nov. 13 MAGIC POWER TECHNOLOGY MPM-U650 series Preliminary Specification FEATURES 650W medical power supply with force air cooling Peak power up to of 750W Single + multi output versions up to 5 outputs included 5Vsb. Input to Output MOPP x 2; Input to Earth, 1 x MOPP Utilizes a thermally efficient U channel chassis design +5Vsb & remote on/off with IP<0.3W(TBD) at no load standby Automatically fan speed control Design to meet medical safety regulations 1. Description Model Name MPM-U653 MPM-U654-1 MPM-U655 MPM-U656 Output Voltage 12V +5Vsb 19V +5Vsb 24V +5Vsb 48V +5Vsb Rated Output Power Peak Output Power Line Regulation Load Regulation Ripple & Noise Voltage Setting 650W 5~10W (TBD) 650W 5~10W (TBD) 650W 5~10W (TBD) 650W 5~10W (TBD) 750W (Target) ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1 (Note 1) (Note 2) 750W (Target) 750W (Target) 750W (Target) (Note 3) (Note 3) (Note 3) Efficiency (Note 4) (TBD) (TBD) (TBD) (TBD) Note: 1) Rated output is 650W with a built in fan model. In a open frame type with suffix “U” model name, it can be 450W (TBD) at 50℃ convection cooled environment. 2) The peak output only at input voltage more than 100VAC, and max. 1000mS(TBD). 3) See below Output Specification for detail test condition. 4) Initial setting voltage is at input 115VAC and all outputs at 60% rated load. 5) Total power is 650W. 2. Input Specification Parameter Input Voltage(Note 1) Label Voltage Input Frequency Input Current Conditions/Description Continuous input range Inrush Current Cold start, 25°C Power Factor No Load Power Consumption (Option) @ 115 VAC @ 230 VAC Meets EN 61000-3-2 class D This function exists only with optional +5Vsb, model no. suffix "-SB" Note 1) Output power derating to _TBD_ W when input voltage less than 90VAC. REV. Nov. 3th 2016 Page 1 of 4 Min. 85 100 47 3.8 Nom. 115 / 230 50 / 60 Max. 264 240 63 8.5 20 40 0.3(TBD) 0.5(TBD) Units VAC VAC Hz A A W MAGIC POWER TECHNOLOGY MPM-U650 series Preliminary Specification 3. Output Specification Parameter Efficiency Conditions/Description @ 115 VAC Rated load, @ 230 VAC Min. Nom. 88 90 Minimum load Max. 89 91 0(Note 1) Units % A Ripple & Noise (Pk-Pk) Rated load, measured by a 20MHz bandwidth limited oscilloscope and the each output is connected with a 10µF Electrolytic Capacitor and a 0.1µF Ceramic Capacitor ±1 % Line Regulation Rated load with ±10% changing in input voltage at 115 / 230 VAC ±1 % ±1 % Load Regulation Hold-Up Time Measured from 60% to 100% rated load and from 60% to 20% rated load (60% ± 40% rated load) Rated load, input 115 / 230 VAC 16 Nom 20 Max ms Note: 1) There will be some provisos TBD. 4. Interface Signals and Internal Protection Parameter Remote Voltage Sense Conditions/Description Compensates for wire voltage drop. PG signal: When power is turned on, the power good signal will go high 100ms to Power Good (PG) / Fail (PF) 500ms after all output DC voltages are within regulation limits. Signal PF signal: The power fail signal will go low at least 1ms before the output voltages fall below the regulation limits. Automatically fan speed control by detecting temp. of unit. 2 step mode (50 / 100% Fan Speed Control fan speed). Protected against output overload, the trigger point between 130%~150% of rated Overload Protection load. Short Circuit Protection Automatic recovery. All output voltage except fan supply, latch off mode. The trigger point between Overvoltage Protection 110%~130% of output voltage. When the power supply operating over the temperature, the power supply will be shut Over temperature Protection down automatically to protect itself. Automatic recovery. Remote on/off (optional) The power supply will be turned on when the power On/Off pin is connected to secondary GND. This function exists only with optional +5Vsb, model no. suffix "SB". 5. Other Options Parameter Connectors Optional multi output Optional Interface Conditions/Description Input: Terminal block or IEC 320/C14 AC inlet. Output: Terminal block or equivalent. (TBD) Optional 2 DC/DC converter with each max. 70W output and each max. 24VDC output. Total output max. power is 650W Only can be installed on MPM-U653, MPM-U654-1, MPM-U655. Function TBD 6. Environment Specification Parameter Storage Temperature Relative Humidity Altitude REV. Nov. 3th 2016 Conditions/Description Non-condensing. Operating Non-operating Page 2 of 4 Min. -40 5 Nom. Max. +85 95 3K 4K Units °C %RH Meter MAGIC POWER TECHNOLOGY Operating Temperature MPM-U650 series Preliminary Specification Linearly derating from 50°C. Refer derating curve below. (TBD) -20 +70 °C Max. Units Derating performance curves (TBD) 7. Safety Approvals, EMI and EMS Specification Parameter Approvals Leakage Current(note 1) Isolation EMI (Note 2) PFC EMS (Note 2) Conditions/Description IEC 60601-1, 3rd edition EN 60601-1, 3rd edition ANSI / AAMI ES60601-1:2005 CAN / CSA-C22.2 No. 60601-1:08 N.C. Earth S.F.C N.C. Touch S.F.C N.C. Patient S.F.C Input to Output (MOPP x 2) Input to PE (MOPP x 1) Output to PE EN 60601-1-2 EN 55011 EN 61000-3-2 EN 61000-3-3 ± 15 KV air discharge IEC 61000-4-2 ± 8 KV contact discharge IEC 61000-4-3 10 V / m IEC 61000-4-4 ± 2KV Line & PE L - N: ± 1KV IEC 61000-4-5 L / N - PE: ± 2KV IEC 61000-4-6 10 V IEC 61000-4-8 10 A / m IEC 61000-4-11 Voltage dips >95% Min. Nom. Design to meet 300 1000 100 300 100 300 4 1.5 1.5 B B D A A A A A A A A μA KVAC Class Criteria A Voltage dips 30% A Voltage dips 60% B Voltage interruptions >95% B Note: 1) according IEC60601-1 test method. 2) As a build-in type power supply, the power supply needs to be installed in a suitable enclosure to pass the EMI/EMC tests. The final assembly has to comply with the valid EMI/EMC and safety. REV. Nov. 3th 2016 Page 3 of 4 MAGIC POWER TECHNOLOGY MPM-U650 series Preliminary Specification 8. Mechanical and Pin Assignment Parameter Dimension Pin assignment Conditions/Description 229 (L) x 127 (W) x 65 (H) mm, tolerance +/- 0.5mm. CN1 CN2: main output “+” CN2B: main output “-“ CN10: Pin 1: 0V Pin 2: 5Vsb Pin 3: PG/PF Pin 4: Remote On/Off ; CN5: Pin 1:DC module 1 (+) Pin 2: DC module 1 (+) Pin 3: DC module 2 (+) Pin 4: DC module 2 (+) Pin 5: option -12V Pin 6: 0V Pin 7: 0V Pin 8: 0V Pin 9: 0V Pin 10: 0V Mechanical Drawing 1. With input terminal block, fan and cover type, estimated size 229 (L) x 127 (W) x 65 (H) mm (TBD). 2. With input terminal block, open frame type, estimated size 229 (L) x 127 (W) x 65 (H) mm (TBD). 3. With AC inlet, Fan and cover type Estimated size 229 (L) x 127 (W) x 65 (H) mm (TBD). 4. With AC inlet, open frame type Estimated size 229 (L) x 127 (W) x 65 (H) mm (TBD). Fan: MF60101V1-10000-G99 (DC12V) 9. Packing Info. (TBD) 10. Label (TBD) REV. Nov. 3th 2016 Page 4 of 4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising