PRODUCT SPECIFICATION Mercury and Lead Free Alkaline Battery
PRODUCT SPECIFICATION
Mercury and Lead Free Alkaline Battery
Model: GP392F
Revision History
Revision
Date
Initiator
Reason for Change
0
2006/10/17
Greater Zhang
New Issue
1
2012/06/05
John Wei
Change discharge time
Prepared By
John Wei
Approved By
Edward Chan
Date: 2012/6/5
Date: 2012/6/5
GPI International Limited
Gold Peak Building, 8/F, 30 Kwai Wing Road,
Kwai Chung, New Territories, Hong Kong.
Tel: (852) 2484 3333 Fax: (852) 24805912
Email: gpii@goldpeak.com
Website: http://www.gpbatteries.com
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Product Specification
GP392F
Model No.:
Document Number: BQS2167
Revision: 1
Page 2 of 4
1. SCOPE
This specification covers the requirements for primary silver oxide button cell.
GP Model : GP392F
IEC : SR41
2. RATINGS
Description
Unit
Description
Nominal Voltage
Nominal Dimension
Application
V
mm
Average Weight
Shelf Life
gram
Date Code
Specification
Silver Oxide Mercury free Low Drain
Button Cell
1.55
OD 7.90 X Ht 3.60
Watch(with alarm and
lamp),calculator ,digital
thermometer ,hearing ,aid , etc.
0.7
Not less than 90% of the service
capacity within first year,
Not less than 85% of the service
capacity within second year storage at
20 ± 2 oC Max 85 %RH.
Unless otherwise specified, each cell
will carry a numberic year code and
an alphabetical month code
160hrs(at 6.2 k ohm Load)
42(at 3.0 k ohm Load)
10 to 25℃ and never exceed 30℃
40-80
Nominal Service Life
Average Service Capacity
Storage Temperature
Storage Humidity
hr
mAh
o
C
RH%
Testing temperature
o
C
20 ±2
Operation temperature
o
C
0 to 45
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Conditions
digital multimeter
micrometer, caliper, projector
digital balance
ie. 6A=Jan 2006
6F=June 2006
cut-off 1.2V
cut-off 1.2V
o
10% loss for 20 days storage at 60 C
Product Specification
GP392F
Document Number: BQS2167
Model No.:
Revision: 1
Page 3 of 4
3. PERFORMANCE
Unless otherwise stated, tested should be done within one month of delivery under the following conditions:
Test
Unit
Specification
Service life
hr
≧ 160
Open Circuit Voltage
(OCV)
V
≧ 1.55
Close Circuit Voltage
(CCV)
Leakage
V
≧ 1.3
External Short
circuit
N/A
Conditions
6.2K ohm load, cut-off voltage 1.2V
Eight batteries discharged to the end voltage,
calculate the average without the exclusion of
any result. No battery permit to go below 8% of
the service hours specified in the table. Only 1
retest is allowed for each lot tested
The open circuit voltage is measured on a
digital voltmeter with input impedance of 1
mega ohm minimum.
Load resistor 200 ohm for 0.1 to 2 seconds
No leakage nor
deformation
When batteries are stored and discharge under
the standard conditions given in this document,
no electrolyte or other internal component shall
surfaces of the battery
No fire and no
explosion.
After standard discharge, short circuit the
cell at 20±5oC until the cell temperature
returns to ambient temperature. (The
resistance of the inter-connecting circuitry
shall not exceed 0.1 ohm.)
Remarks
digital multimeter
digital multimeter
naked eye
4. CONFIGURATIONS, DIMENSIONS AND MARKINGS
Please refer to its Data Sheet.
5. EXTERNAL APPEARANCE
The cell shall be free from cracks, scars, breakage, rust, discoloration, leakage and deformation.
6. WARRANTY
Not less than 90% of the service capacity within first year, Not less than 85% of the service capacity within second
o
year storage at 20 ± 2 C Max 85 %RH.
7. Precaution , Handling and Storage
Ÿ
Do not attempt to take batteries apart or subject them to pressure or impact. Heat may be generated or fire
may result. The alkaline electrolyte is harmful to eyes and skin, and it may damage clothing upon contact.
Ÿ
Keep away from children. If swallowed, contact a physician at once.
Ÿ
Do not mix GP batteries with other battery brands or batteries of a different chemistry such as alkaline and zinc
carbon.
Ÿ
Do not short circuit batteries, permanent damage to batteries may result.
Ÿ
Do not incinerate or mutilate batteries, may burst or release toxic material.
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Product Specification
GP392F
Document Number: BQS2167
Model No.:
Revision: 1
Ÿ
Do not solder directly to cells or batteries.
Ÿ
Store batteries in a cool dry place.
Ÿ
If find any noise, excessive temperature or leakage from a battery, please stop its use.
Ÿ
When not using a battery, disconnect it from the device.
Ÿ
Do not mix new batteries in use with semi-used batteries.
Ÿ
When find battery power down during use, please switch off the device and take batteries out.
Ÿ
Never put a battery into water or seawater.
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Page 4 of 4