biscayne n - Teron Lighting

biscayne n - Teron Lighting
Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL INDOOR
BISCAYNE N
FEATURES
• Steel Housing & End Caps w/ Matte Silver Powder Coat Finish
• High Impact Frosted Acrylic Diffuser
• Steel Reflector Plate w/ Hi-Reflectance White Powder Coat Finish
• Mounts Directly to Wall or Ceiling w/ Four Wall Anchors (Not Included)
• CSA Listed Damp Location
• ADA Compliant
ORDERING INFORMATION
Example : (BSCN24214E - 277E - WAL - DMD - SW -TP)
Matte Silver is Standard Finish
PRODUCT
SOURCE/WATTAGE
VOLTAGE
DIFFUSER / TRIM
FINISH
Biscayne N 25”
BSCN24217E - (2) 17W T8
BSCN24214E - (2) 14W T5
BSCN24224E - HO* - (2) 24W T5
120E - 120V Electronic
277E - 277V Electronic
347E - 347V Electronic
FAL - Frosted Acrylic Lens
(Standard)
WAL - Frosted & White Acrylic
Lens Assembly
SM - Matte Silver
TB - Textured Black
AC - Antique Copper
AS - Antique Silver
BT - Bronze Mist
CP - Copper
KC - Kenworth Chrome
SN - Sand
SW - Swedish Steel
BZ - Textured Bronze
TW - Textured White
Biscayne N 49”
BSCN48232E - (2) 32W T8
BSCN8228E - (2) 28W T5
BSCN48254E - HO* - (2) 54W T5
HCB - Honeycomb Pattern Trim
DMD - Diamond Pattern Trim
PRF - Perforated Pattern Trim
*HO - High Output
Please Note: Trim Runs Length of
Fixture Unless a Motion Sensor is
Ordered. Trim is Then Separated
Into 2 Parts, as Illustrated Above.
R E P L A C E M E N T PA R T S
Frosted 2’ Acrylic Diffuser
Frosted 4’ Acrylic Diffuser
White 2’ Acrylic Lens Assembly
White 4’ Acrylic Lens Assembly
F - Fused (120V / 277V Only)
MSE - Wattstopper FS-505 External
Motion Sensor w/ Power Pack
(120V / 277V Only)
MSI - Wattstopper FM-105 Internal
Motion Sensor (120V / 277V Only)
MSI is For Use With The Following:
- All 2 Lamp Wattages
TP - Tamper Resistant Screws
W2L - Wire 2 Lamps to Integral
Emergency Battery
(T8 Lamping Only)
MSP - Program Start Ballast
(Standard w/ Motion Sensor) ***
NOTES
PA R T N O .
3029662
3001562
38112
38113
RAL Colors or
Custom Match Consult Factory
OPTIONS
*** For Electronic Wattage Fixtures Being Used in Conjunction With an
Occupancy Sensor (Either Provided by us, or Your Own System), a Program
Start Ballast is Recommended in Order to Maximize Lamp Life.
We reserve the right to revise the design or components of any product due to
parts availability or change in UL standards, without assuming any obligation
or liability to modify any products previously manufactured, and without notice.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:sales@teronlight.com
web:teronlight.com
Project:
Type:
Ordering # :
Comments:
DMD: Diamond Pattern Trim
With External Motion Sensor (MSE)
With Internal Motion Sensor (MSI)
HCB: Honeycomb Pattern Trim
With External Motion Sensor (MSE)
With Internal Motion Sensor (MSI)
PRF: Perforated Pattern Trim
With External Motion Sensor (MSE)
With Internal Motion Sensor (MSI)
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:sales@teronlight.com
web:teronlight.com
FIXTURE SENSORS & CONTROLS
FM-105 Super High Frequency Occupancy Sensor
Mounting bracket for
flexible installation
Adjustable time delay
Line voltage occupancy sensor
Adjustable detection sensitivity
Mounts behind fixture
lens hidden from view
Hold-off daylighting control
PROJECT
LOCATION/TYPE
Product
Overview
Description
Flexible Functionality
The FM-105 Super High Frequency Occupancy
Sensor is a line voltage sensor that turns lighting
on and off based on occupancy, and can hold
lights off when sufficient daylight is available. It
detects motion via super high frequency (SHF)
electromagnetic waves and the Doppler principle.
Because it can detect motion through many dense
materials other than metal, the FM-105 can be
installed behind fixture lenses and hidden from
view.
The FM-105 Sensor coverage pattern is
omnidirectional. Depending on its installation, it
can be adjusted to detect occupancy up to 20 feet
away. The FM-105 can be placed inside a lighting
fixture or behind an object made of wood or plastic
so that it is completely hidden from direct view. Its
integrated daylight sensitivity adjusts from 2 to 200
footcandles, and its time delay may be set from 10
seconds to 30 minutes.
Applications
Operation
The FM-105 operates at 120 or 277 VAC and
utilizes SHF technology to control lighting based
on occupancy. It sends out electromagnetic waves
that bounce off nearby surfaces, and uses the
Doppler principle to analyze changes in the return
waves to detect motion in the area (similar to the
way that ultrasonic sensor technology performs).
When motion is detected, the FM-105 turns on the
load, unless the ambient light level is greater than
the daylighting setpoint (if enabled), or turns off the
load when no motion is detected for the preset time
delay.
Features
• Detects movement when installed behind lowdensity fixture materials, such as polycarbonate,
acrylic and glass diffusers
• Provides hold-off daylighting control when
ambient light is greater than daylighting setpoint
www.wattstopper.com
800.879.8585
The FM-105 operates best when installed
behind low-density fixture materials, such as
polycarbonate, acrylic and glass diffusers. FM-105
technology also provides superior detection in hard
surfaced areas such as stairwells and hallways.
This sensor is also suited for installation behind
lenses in outdoor wall sconces, wall packs and
pedestrian-scale luminaires.
• Mounting bracket facilitates installation in
various mounting positions
• Simple line voltage wiring does not require a
power pack
• Can be mounted hidden from view
• Time delay adjustable from 10 seconds to 30
minutes
• Easy adjustment via trimpots
• Adjustable sensitivity range up to 20 feet
• RoHS compliant
Mounting
30 min
-
+
1
200
Sensitivity
CONTROL
FCC ID: Q4BFM105
88T9
APPLIANCE
FM-105
Microwave (5.8 GHz)
GHz)
Occupancy Sensor
FM-105
Time Delay
120/277VAC, 50/60
50/60 Hz
Hz
100-277VAC,
@120VAC:0-600W
0-800WBallast,
Ballast
@120VAC:
orTungsten,
Tungsten
0-600W
Light Level
(footcandles) @277VAC: 0-1200W 1/6
Ballast
hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
10
sec
30 min
-
+
1
200
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Microwave (5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
120/277VAC,
@120VAC:
@120VAC: 0-600W
0-800WBallast,
Ballast
0-600W
orTungsten,
Tungsten
Light Level
(footcandles) @277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
Sensitivity
LINE
10
sec
NEUT
1
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Time Delay
Sensitivity
LOAD
100-277VAC, 50/60
50/60 Hz
Hz
120/277VAC,
@120VAC: 0-600W
0-800W Ballast,
Ballast
0-600W
or Tungsten,
Tungsten
Light Level
1/6 hp
200 (footcandles) @277VAC: 0-1200W Ballast
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
+
LOAD
NEUT
200
FM-105
Microwave (5.8
(5.8 GHz)
GHz)
Microwave
Occupancy Sensor
Sensor
Occupancy
30 min
-
LINE
Time Delay
10
sec
NEUT
FM-105
Microwave (5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
100-277VAC,
@120VAC:0-600W
0-800WBallast,
Ballast
@120VAC:
orTungsten,
Tungsten
0-600W
Light Level
(footcandles) @277VAC: 0-1200W 1/6
Ballast
hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
LOAD
1
Sensitivity
LOAD
+
LINE
30 min
-
NEUT
Time Delay
10
sec
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Mounting foot provides four different mounting positions.
Wiring Diagram
Plastic mounting foot
FM-105
Time Delay
Time Delay
10
sec
30 min
-
+
1
200
FM-105
Microwave (5.8 GHz)
Occupancy Sensor
30 min
-
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
Light Level
200 (footcandles) @277VAC: 0-1200W Ballast
1
100-277VAC, 50/60 Hz
120/277VAC,
@120VAC:
@120VAC:0-600W
0-800WBallast,
Ballast
0-600W
orTungsten,
Tungsten
Light Level
(footcandles) @277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
Microwave (5.8 GHz)
Occupancy Sensor
10
sec
+
Sensitivity
LINE
NEUT
LOAD
Sensitivity
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
LINE
NEUT
Metal
shield
LOAD
FCC ID: Q4BFM105
Lighting
Load
APPLIANCE
CONTROL
88T9
Hot/Line
Neutral
Position metal shield between FM-105 and lamp/ballast.
Coverage
Wall Mount
Ceiling Mount
18’ (5.5m)
18’ (5.5m)
12’ (4m)
12’ (4m)
Installed
FM-105
inside a ceiling
inside
ceiling
mount
mounted
fixture
lighting fixture
at
at8’a (2.5m)
height of 8’
height
6’ (2m)
6’ (2m)
MIN.
3’ (1m)
MAX.
20’ (6m)
Installed
inside a wall
mounted
lighting
fixture at a
height of 5’
(1.52m)
(2.44m)
MAX.
MIN.
Coverage pattern will vary based on installation of sensor and surrounding materials.
Ordering
Information
Pub. No. 29300 rev. 10/2009
Catalog No.
FM-105
Description
Super High Frequency Occupancy Sensor
Voltage
Load Capacity
120 VAC
0-800 W ballast or tungsten
277 VAC
0-1200 W ballast
www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5
FIXTURE SENSORS & CONTROLS
Mounting &
Wiring
• Dimensions: 2.0” x 3.09” x 1.63” (51.0mm x
78.5mm x 41.4mm) L x W x D
• Weight: 2.3 oz (65.2 g)
• Operating temperature range: -4-131°F
(-20-55°C)
• FCC approved
• UL and CUL listed
• Five year warranty
• 120/277 VAC, 50/60 Hz
• Load requirements
@ 120 VAC, 60 Hz: 0-800 W ballast or tungsten
@ 277 VAC, 60 Hz: 0-1200 W ballast
• Light Level: 2-200 fc
• Range/Sensitivity: Up to 20’ (6.1m)
• Time delay: 10 seconds to 30 minutes
• Operating frequency: 5.8 GHz
• Power output: 1 mW
LINE
Specifications
FIxture Sensors & Controls
FS-505/FS-505C Low Voltage Ultrasonic
Fixture Integrated Occupancy Sensors
Modular plug system
streamlines installation
Ultrasonic technology for
open area detection with
line-of-sight obstructions
Easily integrate into
lighting fixtures
Ceiling and wall mount models
Ideal for stairwell, wall and
ceiling mount applications
PROJECT
LOCATION/TYPE
Product
Overview
Description
Applications
The FS-505 and FS-505C Low Voltage Ultrasonic
Fixture Sensors control lighting based on
occupancy. They are designed with a low-profile,
architecturally pleasing appearance to easily
integrate into a wide range of lighting fixtures or a
customized housing. The sensors’ modular plug-in
system utilizes an RJ45 connector and 3’ cord for
flexibility and ease of use.
Typical applications for the FS-505 Series sensors
include open office cubicles, offices, conference
rooms, restrooms and hallways. This technology
also provides superior detection in hard surfaced
areas, such as stairwells and hallways.
Operation
When connected to an FS-PP Power Pack, the
FS-505 Series sensors use high frequency (40 kHz)
ultrasonic technology to sense motion within a
space and automatically turn lights on even when
the sensor has no direct line of sight to occupants.
After the area is vacated and the time delay has
elapsed, the sensors automatically turn the lights
off. Ultrasonic detection operates by transmitting
sound waves throughout an area and measuring the
speed at which they return. Movement increases
the return frequency, which triggers occupancy.
For a large rectangular detection area with ceilingmounted fixtures, the FS-505C provides excellent
coverage. For specialized applications such as
stairwells, the elongated coverage pattern of the
FS-505 is ideal.
The FS-505 can provide bi-level lighting control
in fixtures that have bi-level or dimming ballasts,
resulting in up to 66% energy savings for fixtures
that are on 24-hours a day, seven days a week,
while still providing enough light for safety and
egress.
The FS-505 Series sensors provide functions for
testing, overriding the fixture ‘ON’ and a 72-hour
lamp burn-in mode.
Features
www.wattstopper.com
800.879.8585
• Ultrasonic technology (40Khz)
• 24 VDC
• Compact design for installation in lowprofile fixtures
• Three modes: override, burn-in and test modes
Current Consumption
Power Supply
Time Delay
Coverage at 8’ ht.
Operating Temp
Color
Dimensions*
FS-505C Low Voltage Ultrasonic
Fixture Sensor
24VDC
24VDC
43mA
43mA
FS-PP Fixture Power Pack
FS-PP Fixture Power Pack
5-30 minutes
5-30 minutes
24’ (731.5cm) diameter
30’ x 24’ (457.2 x 365.7cm)
32-131°F (0-55°C)
32-131°F (0-55°C)
White
White
5.2” x 1.25” x .62”
(132.4mm x 32.2mm x 15.7mm)
5.2” x 1.25” x .62”
(132.4”mm x 32.2mm x 15.7mm)
Applications
Wall
Ceiling
FS-505
Mounted in
Stairwell
FS-505C in
Pendantmounted
fixture
Landing
FS-505C
FS-PP
Landing
Landing
Wiring &
Coverage
Coverage Patterns @ 8 ft Mounting Height
feet/
meters
3' 6' 9' 12' 15' 18' 21' 24' 27'
0.9 1.8 2.7 3.6 4.5 5.4 6.4 7.3 8.2
feet/
meters
15' (4.5m)
15' (4.5m)
12' (3.6m)
12' (3.6m)
9' (2.7m)
9' (2.7m)
6' (1.8m)
6' (1.8m)
3' (0.9m)
3' (0.9m)
20° from
vertical
12' 9' 6' 3'
3.6 2.7 1.8 0.9
0
3' 6' 9' 12'
0.9 1.8 2.7 3.6
0
3' (0.9m)
3' (0.9m)
6' (1.8m)
6' (1.8m)
9' (2.7m)
9' (2.7m)
12' (3.6m)
12' (3.6m)
15' (4.5m)
15' (4.5m)
18' (5.4m)
FS-505C
FS-505
FS Low Voltage Wiring Example
Standard connection
between FS sensor
and FS-PP
power pack
Ordering
Information
Catalog No.
Description
FS-505
Low Voltage Ultrasonic Fixture Occupancy Sensor for Stairway Applications; 24 VDC fixture mount
One FS sensor connected to two FS-PP
FS-PP
FS-CK-1
kit required
FS-505C
Low Voltage Ultrasonic Fixture Occupancy
(two 10' cables w/male connectors
and one
FS-PPv2
Fixture Power Pack 120/277 VAC; 60Hz
female receptacle splitter)
NOTE:
Sensor for Open Areas; 24 VDC fixture mount
All FS Low Voltage Sensors require an FS-PP or other WattStopper Power
Pack (ordered separately) to operate.
FS-PP
Pub. No. 26802 rev. 03/2010
www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5
fi x t u r e s e n s o r s & c o n t r o l s
Voltage
FS-505 Low Voltage Ultrasonic
Fixture Sensor
Door
Specifications
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising