Products no longer available

Products no longer available
Technical data sheet
NV230-3(-T)
Linear actuator for
2-way and 3-way globe valves
•Actuating force 1000 N
•Nominal voltage AC 230 V
•3-point control
•NV230-3 with cable connection
NV230-3-T with terminal connection
•Brackets and adapter sets for
third-party valves as accessories (UNV-..)
o
n
ts
Technical data
c
u
d
o
r
Electrical data
P
Functional data
Safety
Dimensions / weight
r
e
g
n
lo
e
l
b
a
l
i
a
v
a
Nominal voltage
Nominal voltage range
Power consumption Operation
For wire sizing
Connection NV230-3
NV230-3-T
Parallel operation
AC 230V, 50/60 Hz
AC 198 ... 264V
2 W @ nominal force
4.5 VA
Cable 1 m, 4 x 0.75 mm2
Terminal connection
Yes (note performance data for supply!)
Actuating force Closing force
Inhibiting force
Manual override
Nominal stroke
Actuating time
Sound power level
Position indication
1000 N
800 N
With hexagon socket screw key, temporary
20 mm
7.5 s/mm or 3.75 s/mm, selectable
≤35 dB (A)
mechanical 5 … 20 mm stroke
Protection class
Degree of protection
EMC
Low-voltage directive
Mode of operation
Rated impulse voltage
Control pollution degree
Ambient temperature
Non-operating temperature
Ambient humidity
Maintenance
I (with protective conductor)
IP54
CE according to 2004/108/EC
CE according to 2006/95/EC
Type 1 (EN 60730-1)
4 kV (EN 60730-1)
3 (EN 60730-1)
0 ... +50°C
–40 ... +80°C
95% r.h., non-condensating (EN 60730-1)
Maintenance-free
Dimensions
Weight
See «Dimensions» on page 4
approx. 1.5 kg with bracket UNV-002 (without valve)
..
..
..
..
..
.
Safety notes
!
www.belimo.com
• The actuator has been designed for use in stationary heating, ventilation and air conditioning
systems and is not allowed to be used outside the specified field of application, especially in
aircraft or in any other airborne means of transport.
• Caution: Power supply voltage!
• It may only be installed by suitably trained personnel. Any legal regulations or regulations
issued by authorities must be observed during assembly.
• The device does not contain any parts that can be replaced or repaired by the user.
• The device contains electrical and electronic components and is not allowed to be disposed
of as household refuse. All locally valid regulations and requirements must be observed.
T6-NV230-3(-T) • en • v1.1 • 04.2012 • Subject to changes
/4
NV230-3(-T)
Linear actuator for globe valves, AC 230 V, 1000 N
Product features
Mode of operation
Installation on BELIMO valves
The actuator is activated with a 3-point signal.
If a combination of actuator and BELIMO globe valve is ordered, then one UNV-002 bracket is
included in the scope of delivery.
e
l
b
a
l
i
a
v
a
If an actuator is ordered without Belimo globe valve, then the UNV-002 bracket (see «Accessories»)
must also be ordered.
Installation on third-party valves
Prior to installation on a third-party valve, a suitable bracket UNV-.. (see «Accessories») must
first be screwed to the actuator. The adapter set integrated therein is comprised of a valve neck
adapter and a valve stem adapter. The valve neck adapter, together with the clamping strap on
the bracket, makes possible simple attachment on the neck of the valve. The valve stem adapter
is mounted on the valve stem. The linear spindle can be coupled semi-automatically to the valve
stem with the valve stem coupling.
The actuator can be rotated by 360° on the valve neck.
r
e
g
n
lo
Retrofit actuators NV.. -R are also available which are equipped with a Retrofit bracket and
which can be used with corresponding ZNV-.. (adapter set) for valves from a wide array of
manufacturers.
o
n
ts
Manual override
c
u
d
o
r
P
Functional reliability
Position indication
Combination valve/actuator
The stroke can be adjusted in a voltage-free state by using a hexagon socket screw key (5 mm),
which is plugged into the actuator at the top. If the hexagon socket screw key is turned in a
clockwise direction, then the actuator spindle will extend from the actuator housing (pushing) and
maintain the position until a nominal voltage is applied (the controller has first priority).
The actuator is protected against short circuits, polarity reversal and overloading.
The stroke is indicated mechanically on the bracket. The stroke range adjusts itself automatically.
Refer to the valve documentation for suitable valves, their permitted media temperatures and
closing pressures.
Accessories
Description
Mechanical accessories
Brackets and adapter sets UNV-..
see www.belimo.eu/retrofit
Electrical installation
Wiring diagram
N L1
Notes
!
• Caution: Power supply voltage!
• Parallel connection of other actuators possible.
Note performance data for supply.
1
2
3
Y1 Y2
/4
Cable colours:
1 = blue
2 = white
3 = white
= yellow/green
T6-NV230-3(-T) • en • v1.1 • 04.2012 • Subject to changes
www.belimo.com
NV230-3(-T)
Linear actuator for globe valves, AC 230 V, 1000 N
Functions
Alignment of the operating elements
S1.1
The terminals for the cable connection and the
operating element S1 are located under the
cover of the actuator.
By setting slide switch S1 it is possible to
configure the actuator very simply on site to
suit actual requirements.
S1.1 Actuating time
S1.2 Valve closing point
e
l
b
a
l
i
a
v
a
1
M
S1
1 2
2
3
r
e
g
n
lo
o
r
P
standard
fast
o
n
ts
1)
Valve closing point
up 2)
down 3)
Description
The running time for full stroke varies as a function of the nominal stroke.
(The running time for a 20 mm stroke and the standard actuating time is 150 s).
Actuating time 7.5 s/mm
3.75 s/mm
Symbol
S1.2
ON
1
c
u
d
Function
Actuating time
7.5 s/mm
ON
2
N Y1 Y2
Functional description
Symbol
1
2
ON
▲
H4/5..B
H6/7..N
H6/7..R
H7..X..-S2
H7..Y..-S2
▼
H6..S
H6..SP
H6..X..-S(P)2
Switch
S1.1
OFF
7.5 s/mm
Actuating time 3.75 s/mm
ON
3.75 s/mm
Closing point with linear spindle retracted or extended.
The actuator spindle is retracted into the actuator and the valve stem is
extended from the fitting.
S1.2
Symbol
Consequence
Y1
▲
OFF
The linear spindle is extended from the actuator and the valve stem is retracted
into the fitting.
Y1
▼
ON
1)Factory
settings
setting for valves H4..B, H5..B, H6..N, H6..R, H7..N, H7..R, H7..X..-S2 and H7..Y..-S2
3)Standard setting for valves H6..S, H6..SP and H6..X..-S(P)2
2)Standard
3-point control
7.5 s/mm
Note
The actuator spindle direction can also be reversed
by inverting the Y1 and Y2 wires.
www.belimo.com
3.75 s/mm
▲
OFF
▼
OFF
Closing point
bottom
OFF
ON
▲
ON
▼
ON
OFF
ON
Relay contact
(Y2)
Y1 Y2
S1.2
Relay contact
(Y1)
S1.1
Closing point
top
Actuating time
fast
3
Linear spindle moves
Actuating time
standard
2
Closing point
Valve
1
Actuating time
Symbols
N L1
0
1
0
1
0
1
0
1
0
0
0
1
0
1
0
1
0
1
T6-NV230-3(-T) • en • v1.1 • 04.2012 • Subject to changes
ccw
cw
stops
stops
OFF
ON
ON
OFF
OFF
ON
ON
OFF
/4
NV230-3(-T)
Linear actuator for globe valves, AC 230 V, 1000 N
Dimensions [mm]
Dimensional drawings
179
110
o
n
s
t
c
u
r
e
g
n
lo
e
l
b
a
l
i
a
v
a
205
55
72
d
o
Pr
Further documentations
/4
• Overview of brackets and adapter sets on www.belimo.eu/retrofit
• Complete overview «The complete product range of water solutions»
• Data sheets for globe valves
• Installation instructions for actuators and/or globe valves, respectively
• Notes for project planning (hydraulic characteristic curves and circuits, installation regulations,
commissioning, maintenance, etc.)
• Specification texts
T6-NV230-3(-T) • en • v1.1 • 04.2012 • Subject to changes
www.belimo.com
Was this manual useful for you? yes no