Model 53 12 Electronic LCD Totalizer

Model 53 12 Electronic LCD Totalizer
LCD Totalizer
Model 53
Electronic
Description
The Model 53 Electronic Totalizer with 7 or 8 LCD digits is ideal as a replacement for electro-mechanical totalizers or where external power is not
available. Powered by an internal lithium battery these products are highly reliable and provide the user with a choice of several options; with or
without reset and multiple count ranges for optimized performance. The case is available in either tan or black.
Features
Options
•
•
•
•
•
•
•
•
Lithium battery
Choice of non-reset or remote reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Termination
Case color
Private labeling
Mounting adapter plates
8 Digits
Specifications
Figures:
Reset:
Speed:
7 digit:
7 or 8 LCD figures, 0.32’’ [8mm] high
Remote, manual, and non-reset
Temperature:
Operating:
Storage:
Humidity:
Vibration
Operating:
Non-Operating:
Shock
Operating:
Non-Operating:
Dielectric:
Accuracy:
0-40 counts/second [min. 12.5ms - on, 12.5ms - off]
0-150 counts/second [min. 3.3ms - on, 3.3ms - off]
0-35 count/second [min14.3ms - on, 14.3ms - off]
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Self-powered (internal lithium battery)
Panel
Terminal block, or connector with 8’’ [200mm] wire
leads
UL Recognized, CSA Certified, CE Compliant
2 oz. [57g]
8 digit:
Inputs:
Power:
Mounting:
Terminations:
Approvals:
Weight
-4°F to +140°F [-20°C to +60°C]
-40°F to +165°F [-40°C to +75°C]
0 to 95% RH, Non-condensing
10 to 55Hz, 0.01” [0.25mm] Double Amplitude
10 to 55Hz, 0.03” [0.75mm] Double Amplitude
10G
30G
1000VAC 50/60Hz for 1 Minute
100% [Provided Signal Meets Stated Parameters]
Models
Description
Models
Description
5300-0000
5300-0001
5300-1000
5300-1001
5300-2000
5300-2001
40/150cps, switch, remote reset, terminal block, tan case
40/150cps, switch, remote reset, terminal block, black case
40/150cps, 3-30VDC, remote reset, terminal block, tan case
40/150cps, 3-30VDC, remote reset, terminal block, black case
40cps, 20-250VAC/VDC, remote reset, terminal block, tan case
40cps, 20-250VAC/VDC, remote reset, terminal block, black
case
40/150cps, switch, manual & remote reset, terminal block, tan
case
5300-0101
40/150cps, switch, manual & remote reset, terminal block,
black case
40/150cps, 3-30VDC, remote reset, connector with 8”
[203mm] wire leads, tan case
40/150cps, 3-30VDC, remote reset, connector with 8”
[203mm] wire leads, black case
40cps, 20-250VAC/VDC, non-reset, terminal block, tan case
40cps, 20-250VAC/VDC, non-reset, terminal block, black case
5300-0100
5300-1010
5300-1011
5300-2200
5300-2201
* All part numbers shown are for 7 digit models. Please contact the factory for information on 8 digit models.
Dimensions
TERMINAL BLOCK
1.92 [48.8]
WIRE LEADS
1.72 [43.7]
0.10 [2.5]
1.02 [25.9]
1.92 [48.8]
1.47 [37.3]
1.58 [40.0]
0.10 [2.5]
1.47 [37.3]
1.02 [25.9]
0.86 [21.8]
Applications
Number of Parts
12
Shear
www.redingtoncounters.com
Packaging Line
0.86 [21.8]
Model 53
Electronic
LCD Hour Meter
Description
The Model 53 Hour Meter with 7 LCD digits, 999999.9, and internal lithium battery, is ideal for applications requiring time accumulation for maintenance scheduling, warranty monitoring, lease time or fee computation. Applications include, test equipment, panel builders, mobile equipment and
medical devices. A choice of time ranges, in hours, minutes or seconds provides the user with a wide choice of recording increments.
Features
Options
•
•
•
•
•
•
•
Lithium battery
Choice of non-reset or remote reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Termination
Case color
Private labeling
Mounting adapter plates
Specifications
Figures:
Reset:
Inputs:
Power:
Mounting:
Terminations:
7 LCD figures, 0.32’’ [8mm] high
Remote, manual, and non-reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Self-powered (internal lithium battery)
Panel
Terminal block, or connector with 8’’ [200mm] wire
leads
Temperature
Operating:
Storage:
Approvals:
-4°F to +140°F [-20°C to +60°C]
-40°F to +165°F [-40°C to +75°C]
UL Recognized, CSA Certified, CE Compliant
Weight:
Humidity:
Vibration
Operating:
Non-Operating:
Shock
Operating:
Non-Operating:
Dielectric:
Accuracy:
2 oz. [57g]
0 to 95% RH, Non-condensing
10 to 55Hz, 0.01” [0.25mm] Double Amplitude
10 to 55Hz, 0.03” [0.75mm] Double Amplitude
10G
30G
1000VAC 50/60Hz for 1 Minute
Quartz Accuracy (better than 0.005%)
Models
Description
Models
Description
5320-0000
5320-0001
5321-0000
5321-0001
5322-0000
5322-0001
5320-1000
5320-1001
5320-2000
5320-2001
Hours, switch, remote reset, terminal block, tan case
Hours, switch, remote reset, terminal block, black case
Minutes, switch, remote reset, terminal block, tan case
Minutes, switch, remote reset, terminal block, black case
Seconds, switch, remote rest, terminal block, tan case
Seconds, switch, remote rest, terminal block, black case
Hours, 3-30VDC, remote reset, terminal block, tan case
Hours, 3-30VDC, remote reset, terminal block, black case
Hours, 20-250VAC/VDC, remote reset, terminal block, tan case
Hours, 20-250VAC/VDC, remote reset, terminal block, black case
5320-0100
Hours, switch, manual & remote reset, terminal block, tan
case
Hours, switch, manual & remote reset, terminal block, black
case
Hours, 3-30VDC, remote reset, connector with 8” [203.2mm]
wire leads, tan case
Hours, 3-30VDC, remote reset, connector with 8” [203.2mm]
wire leads, black case
Hours, 20-250VAC/VDC, non-reset, terminal block, tan case
Hours, 20-250VAC/VDC, non-reset, terminal block, black case
5320-0101
5320-1010
5320-1011
5320-2200
5320-2201
Dimensions
TERMINAL BLOCK
1.92 [48.8]
WIRE LEADS
1.72 [43.7]
0.10 [2.5]
1.02 [25.9]
1.92 [48.8]
1.47 [37.3]
0.86 [21.8]
1.58 [40.0]
0.10 [2.5]
1.02 [25.9]
1.47 [37.3]
0.86 [21.8]
Applications
Total Operating Time
www.redingtoncounters.com
Injection molding
13
Model 53
Electronic
LCD Tachometers
Description
The Model 53 Tachometers are self-powered by an internal lithium battery. They provide a low cost solution to accurately measure speed or
production rates for a number of manufacturing and process applications. A wide selection of inputs, dry contact closure, 3-30VDC or
20-250VAC/VDC, make the Model 53 adaptable to most applications. When used with the appropriate sensor, the unit can display units per
minute, length per minute or revolutions per minute. The maximum input rate is 10,000 counts per minute.
Features
Options
•
•
•
•
•
•
•
Lithium battery
Choice of non-reset or remote reset
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Termination
Case color
Private labeling
Mounting adapter plates
Specifications
Figures:
Reset:
Speed:
Inputs:
Power:
Mounting:
Terminations:
7 LCD figures, 0.32” [8mm] high
Remote, manual, or non-reset
10,000 counts/minute
Switch (no-voltage), 3-30VDC, 20-250VAC/VDC
Self-powered (internal lithium battery)
Panel
Terminal block, or connector with 8’’ [200mm] wire
leads
UL Recognized, CSA Certified, CE Compliant
Approvals:
Temperature:
Operating:
Storage:
Humidity:
Vibration
Operating:
Non-Operating:
Shock
Operating:
Non-Operating:
Dielectric:
Accuracy:
Weight:
0 to 95% RH, Non-condensing
10 to 55Hz, 0.01” [0.25mm] Double Amplitude
10 to 55Hz, 0.03” [0.75mm] Double Amplitude
10G
30G
1000VAC 50/60Hz for 1 Minute
Typically within 1% above 700Hz
2 oz. [57g]
-4°F to +140°F [-20°C to +60°C]
-40°F to +165°F [-40°C to +75°C]
Models
Description
Models
Description
5330-0000
5330-0001
5330-1000
5330-1001
Switch, remote reset, terminal block, tan case
Switch, remote reset, terminal block, black case
3-30VDC, remote reset, terminal block, tan case
3-30VDC, remote reset, terminal block, black case
5330-2000
5330-2001
5330-2200
5330-2201
20-250VAC/VDC,
20-250VAC/VDC,
20-250VAC/VDC,
20-250VAC/VDC,
remote reset, terminal block, tan case
remote reset, terminal block, black case
non-reset, terminal block, tan case
non-reset, terminal block, black case
Dimensions
TERMINAL BLOCK
1.92 [48.8]
WIRE LEADS
1.72 [43.7]
0.10 [2.5]
1.02 [25.9]
1.92 [48.8]
1.47 [37.3]
0.86 [21.8]
Applications
Motor/pulley Speed
14
www.redingtoncounters.com
1.58 [40.0]
0.10 [2.5]
1.02 [25.9]
1.47 [37.3]
0.86 [21.8]
Instruction Sheet
Model 53
Electronic
ELECTRONIC TOTALIZERS, HOUR METERS AND TACHOMETERS
1.79 +/- 0.01
[45.5 +1/-0]
0.89 +/- 0.01
[22.6 +1/-0]
Panel Cutout
MOUNTING:
The mounting clip accommodates panel thicknesses up
to 1/4” [6.4mm].
Optional
Gasket Panel
Unit
WIRING:
Panel adapter plates are available in flush and 2 hole
mount to fit various panel cutouts. Consult the factory
for availability.
Clip
SWITCH (non-voltage)
1 2
3 4 5
INPUT
RESET
Pin 1 used for 0 - 150 cps only
Color code for
1 2 3 4 5 -
the 8” [203mm] lead wires (24AWG) are:
Yellow
Blue
Black
Violet
Gray
3 - 30 VDC
1 2 3 4 5
INPUT
+DC
+DC
RESET
3 - 30VDC units are protected for transient voltages up to 50 volts
with pulse widths of up to 1 second at a 1% duty cycle (including
reverse polarity).
Pin 1 used for 0 - 150 cps only
20 - 250VAC/VDC
The operating AC frequency range is 40 to 400Hertz.
1 2 3 4 5
INPUT
AC/DC
AC/DC
Terminal block will accept wire sizes from 14 to 24AWG.
RESET
Pin 1 not used
NOTES:
INPUT / RESET PARAMETERS
To insure proper performance from totalizers the following minimum input durations are required:
0 to 35 cps totalizer
Minimum
14.3 ms “on”
14.3 ms “off”
The count is activated on the falling edge.
0 to 40 cps totalizer
Minimum
12.5 ms “on”
12.5 ms “off”
The count is activated on the falling edge.
0 to 150 cps totalizer
Minimum
3.3 ms “on”
3.3 ms “off”
The count is activated on the rising edge.
All resettable totalizers and hour meters can be reset by a pulse with a minimum duration of 6 milliseconds.
DUAL RANGE TOTALIZER PROTECTION FEATURE:
Dual range totalizers have a built-in range protection feature. This feature will protect the totalizer from receiving a false signal from the unused input
line. Once a totalizer has received an input from pin #1 or pin #2, it will only accept inputs from that pin until the unit has been reset. For example, if a
totalizer is run in the low speed range and it is determined that a high speed range is preferred, simply switch the input from pin #2 to pin #1 and reset the
totalizer to de-activate this range protection feature. Conversely, if a totalizer is run in high speed range and it is determined that a low speed range is
preferred, simply switch the input from pin #1 to pin #2 and reset the totalizer.
SPECIAL WIRING OPTION
There is an internal connection between pin 3 and pin 5, a single wire can be used by connecting it to either pin 3 or pin 5. This option does not apply
for units with input of 20 - 250VAC/VDC or manual reset enable.
OPTIONAL INPUTS:
Optional control circuity (such as transistors) may be used as inputs provided that such circuitry provides the required parameters of the model used.
www.redingtoncounters.com
15
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising