PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List

PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List
Satellite 215Q/216Q
Dispensers Parts List
PT-1942B
(formerly 035389)
Computer Programs and Documentation
All Gasboy computer programs (including software on diskettes and within memory chips) and documentation are copyrighted by, and shall remain the property of, Gasboy. Such
computer programs and documents may also contain trade secret information. The duplication, disclosure, modification, or unauthorized use of computer programs or
documentation is strictly prohibited, unless otherwise licensed by Gasboy.
Federal Communications Commission (FCC) Warning
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly
approved by the manufacturer could void the user’s authority to operate this equipment.
Approvals
Gasboy, Greensboro, is an ISO 9001:2000 registered facility.
Underwriters Laboratories (UL):
New York City Fire Department (NYFD):
California Air Resources Board (CARB):
UL File#
MH4314
MH6418
MH7404
MH10581
Products listed with UL
NYFD C of A #
Product
Executive Order #
Product
All dispensers and self-contained pumping
units
Power operated Transfer Pump Models 25,
25C, 26, 27, 28, 72, 72S, 72SP, 72X, 73 and
1820
Hand operated Transfer Pump Models 1230
Series, 1243 Series, 1520 and 1720 Series
Key control unit, Model GKE-B Series
Card reader terminals, Models 1000, 1000P
Site controller, Model 2000S CFN Series
Data entry terminals, Model TPK-900 Series
Fuel Point Reader System
4823
9100A, 9140A, 9152A, 9153A,
9800A, 9840A, 9850A, 9852A,
9853A, 9140
9822A, 9823A
9100Q, 9140Q, 9152Q, 9153Q,
9800Q, 9840Q, 9852Q, 9853Q
G-70-52-AM
G-70-150-AE
Balance Vapor Recovery
VaporVac
4997
5046
National Conference of Weights and Measures (NCWM) - Certificate of Compliance (CoC):
Gasboy pumps and dispensers are evaluated by NCWM under the National Type Evaluation Program (NTEP). NCWM has issued the following CoC:
CoC#
Product
Model #
95-179A2
Dispenser
9100 Retail Series, 8700
91-019A2
Series, 9700 Series
CoC#
Dispenser
95-136A5
Dispenser
9800 Series
Controller
91-057A3
Product
Model #
CoC#
Product
Model #
9100 Commercial
Series
1000 Series FMS,
2000S-CFN Series
Patents
Gasboy products are manufactured or sold under one or more of the following US patents:
Dispensers
5,257,720
Point of Sale/Back Office Equipment
D335,673
Additional US and foreign patents pending.
Trademarks
Non-registered trademarks
Registered trademarks
Atlas™
Consola™
Infinity™
ASTRA®
Fuel Point®
Gasboy®
Keytrol®
Slimline®
This document is subject to change without notice. · For information regarding Gasboy Literature, call (336) 547-5661
E-mail: literature@gasboy.com · Internet: http://www.gasboy.com
© 2005 GASBOY · All Rights Reserved
Additional US and foreign trademarks pending.
Other brand or product names shown may be
trademarks or registered trademarks of their
respective holders.
Table of Contents
Table of Contents
1 – Important Safety Information
1-1
2 – Introduction
2-1
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Intended Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Related Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Abbreviations and Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
3 – Parts List
3-1
Using this Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
215Q/216Q Front and Side Views - Side Load (Illustration) . . . . . . . . . . . . . . . . . . . . . . . 3-2
215Q/216Q Front and Side Views - Side Load . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
215Q/216Q Front and Side Views - Front Load Option (Illustration) . . . . . . . . . . . . . . . . . 3-4
215Q/216Q Front and Side Views - Front Load Option . . . . . . . . . . . . . . . . . . . 3-5
215Q/216Q Twin Front and Side Views - Front Load (Illustration) . . . . . . . . . . . . . . . . . . 3-6
215QTW/216QTW Twin Front and Side Views - Front Load . . . . . . . . . . . . . . . 3-7
215Q/216Q Chassis Assembly (Illustration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
215Q/216Q Chassis Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
215Q/216Q Chassis Assembly - Front Load Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
215Q/216Q Chassis Assembly - Front Load Option . . . . . . . . . . . . . . . . . . . . 3-10
215QTW/216QTW Twin Chassis Assembly - Front Load Option (Illustration) . . . . . . . . 3-12
215QTW/216QTW Twin Chassis Assembly - Front Load Option . . . . . . . . . . 3-12
Switch and Conduit Assembly (Illustration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
Switch Housing and Wire Assembly, 064461 (Illustration) . . . . . . . . . . . . . . . . . . . . . . . 3-15
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page i
Table of Contents
This page is intentionally left blank.
Page ii
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Important Safety Information
1 – Important Safety Information
This section introduces the hazards and safety precautions
associated with installing, inspecting, maintaining or servicing
this product. Before performing any task on this product, read
this safety information and the applicable sections in this
manual, where additional hazards and safety precautions for
your task will be found. Fire, explosion, electrical shock or
pressure release could occur and cause death or serious
injury, if these safe service procedures are not followed.
Read the Manual
Read, understand and follow this manual and any other
labels or related materials supplied with this equipment. If you
do not understand a procedure, call a Gasboy Authorized
Service Contractor or call the Gasboy Service Center at
1-800-444-5529. It is imperative to your safety and the safety
of others to understand the procedures before beginning
work.
Preliminary Precautions
You are working in a potentially dangerous environment of
flammable fuels, vapors, and high voltage or pressures. Only
trained or authorized individuals knowledgeable in the related
procedures should install, inspect, maintain or service this
equipment.
Follow the Regulations
Applicable information is available in National Fire Protection
Association (NFPA) 30A; Code for Motor Fuel Dispensing
Facilities and Repair Garages, NFPA 70; National Electrical
Code (NEC), Occupational Safety and Hazard Association
(OSHA) regulations and federal, state, and local codes. All
these regulations must be followed. Failure to install, inspect,
maintain or service this equipment in accordance with these
codes, regulations and standards may lead to legal citations
with penalties or affect the safe use and operation of the
equipment.
Emergency Total Electrical Shut-off
The first and most important information you must know is
how to stop all fuel flow to the pump/dispenser and island.
Locate the switch or circuit breakers that shut off all power to
all fueling equipment, dispensing devices, and Submerged
Turbine Pumps (STPs).
!
! WARNING
The EMERGENCY STOP, ALL STOP, and
PUMP STOP buttons at the cashier’s station
WILL NOT shut off electrical power to the pump/
dispenser. This means that even if you activate
these stops, fuel may continue to flow
uncontrolled.
You must use the TOTAL ELECTRICAL SHUTOFF in the case of an emergency and not the
console’s ALL STOP and PUMP STOP or
similar keys.
Total Electrical Shut-off Before Access
Any procedure that requires access to electrical components
or the electronics of the dispenser requires total electrical
shut off of that unit. Understand the function and location of
this switch or circuit breaker before inspecting, installing,
maintaining, or servicing Gasboy equipment.
Evacuating, Barricading, and Shutting Off
Any procedure that requires access to the pump/dispenser or
STPs requires the following actions:
• An evacuation of all unauthorized persons and vehicles
from the work area
• Use of safety tape, cones or barricades at the affected
unit(s)
• A total electrical shut-off of the affected unit(s)
Replacement Parts
Use only genuine Gasboy replacement parts and retrofit kits
on your pump/dispenser. Using parts other than genuine
Gasboy replacement parts could create a safety hazard and
violate local regulations.
Safety Symbols and Warning Words
This section provides important information about warning
symbols and boxes.
Alert Symbol
This safety alert symbol is used in this manual and
on warning labels to alert you to a precaution which must be
followed to prevent potential personal safety hazards. Obey
safety directives that follow this symbol to avoid possible
injury or death.
Signal Words
These signal words used in this manual and on warning
labels tell you the seriousness of particular safety hazards.
The precautions below must be followed to prevent death,
injury or damage to the equipment:
DANGER: Alerts you to a hazard or unsafe practice
!
which will result in death or serious injury.
WARNING: Alerts you to a hazard or unsafe
!
practice that could result in death or serious injury.
CAUTION with Alert symbol: Designates a hazard
!
or unsafe practice which may result in minor injury.
CAUTION without Alert symbol: Designates a
hazard or unsafe practice which may result in
property or equipment damage.
Working with Fuels and Electrical Energy
Prevent Explosions and Fires
Fuels and their vapors will explode or burn, if ignited. Spilled
or leaking fuels cause vapors. Even filling customer tanks will
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 1-1
Important Safety Information
cause potentially dangerous vapors in the vicinity of the
dispenser or island.
No Open Fire
Open flames from matches, lighters, welding
torches or other sources can ignite fuels and their vapors.
No Sparks - No Smoking
Sparks from starting vehicles, starting or using power tools,
burning cigarettes, cigars or pipes can also ignite fuels and
their vapors. Static electricity, including an electrostatic
charge on your body, can cause a spark sufficient to ignite
fuel vapors. Every time you get out of a vehicle, touch the
metal of your vehicle, to discharge any electrostatic charge
before you approach the dispenser island.
Working Alone
It is highly recommended that someone who is capable of
rendering first aid be present during servicing. Familiarize
yourself with Cardiopulmonary Resuscitation (CPR) methods,
if you work with or around high voltages. This information is
available from the American Red Cross. Always advise the
station personnel about where you will be working, and
caution them not to activate power while you are working on
the equipment. Use the OSHA Lockout/ Tagout procedures. If
you are not familiar with this requirement, refer to this
information in the service manual and OSHA documentation.
Working With Electricity Safely
Ensure that you use safe and established practices in
working with electrical devices. Poorly wired devices may
cause a fire, explosion or electrical shock. Ensure that
grounding connections are properly made. Take care that
sealing devices and compounds are in place. Ensure that you
do not to pinch wires when replacing covers. Follow OSHA
Lockout/Tagout requirements. Station employees and service
contractors need to understand and comply with this program
completely to ensure safety while the equipment is down.
Hazardous Materials
Some materials present inside electronic enclosures may
present a health hazard if not handled correctly. Ensure that
you clean hands after handling equipment. Do not place any
equipment in the mouth.
!
WARNING
The pump/dispenser contains a chemical known to the
State of California to cause cancer.
!
WARNING
The pump/dispenser contains a chemical known to the
State of California to cause birth defects or other
reproductive harm.
Page 1-2
In an Emergency
Inform Emergency Personnel
Compile the following information and inform emergency
personnel:
• Location of accident (for example, address, front/back of
building, and so on)
• Nature of accident (for example, possible heart attack, run
over by car, burns, and so on)
• Age of victim (for example, baby, teenager, middle-age,
elderly)
• Whether or not victim has received first aid (for example,
stopped bleeding by pressure, and so on)
• Whether or not a victim has vomited (for example, if
swallowed or inhaled something, and so on)
WARNING
!
Gasoline ingested may cause unconsciousness
and burns to internal organs.
Do not induce vomiting.
Keep airway open.
Oxygen may be needed at scene.
Seek medical advice immediately.
WARNING
!
Gasoline inhaled may cause unconsciousness
and burns to lips, mouth and lungs.
Keep airway open.
Seek medical advice immediately.
!
WARNING
Gasoline spilled in eyes may cause burns to eye
tissue.
Irrigate eyes with water for approximately 15
minutes.
Seek medical advice immediately.
!
!
WARNING
Gasoline spilled on skin may cause burns.
Wash area thoroughly with clear water.
Seek medical advice immediately.
IMPORTANT: Oxygen may be needed at scene if gasoline
has been ingested or inhaled. Seek medical advice
immediately.
Lockout/Tagout
Lockout/Tagout covers servicing and maintenance of
machines and equipment in which the unexpected
energization or start-up of the machine(s) or equipment or
release of stored energy could cause injury to employees or
personnel. Lockout/Tagout applies to all mechanical,
hydraulic, chemical or other energy, but does not cover
electrical hazards. Subpart S of 29 CFR Part 1910 - Electrical
Hazards, 29 CFR Part 1910.333 contains specific Lockout/
Tagout provision for electrical hazards.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Important Safety Information
Hazards and Actions
!
WARNING
Spilled fuels, accidents involving pumps/dispensers, or uncontrolled fuel flow create a
serious hazard.
Fire or explosion may result, causing serious injury or death.
Follow established emergency procedures.
The following actions are recommended regarding these hazards:
Collision of a Vehicle with Unit
Fire at Island
Fuel Spill
• Do not go near a fuel spill or allow anyone else in the area.
• Use station EMERGENCY CUTOFF immediately. Turn off all system circuit breakers to the island(s).
• Do not use console E-STOP, ALL STOP and PUMP STOP to shut off power. These keys do not
remove AC power and do not always stop product flow.
• Take precautions to avoid igniting fuel. Do not allow starting of vehicles in the area. Do not allow
open flames, smoking or power tools in the area.
• Do not expose yourself to hazardous conditions such as fire, spilled fuel or exposed wiring.
• Call emergency numbers.
Page 1-3
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Important Safety Information
This page is intentionally left blank.
Page 1-4
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Purpose
Introduction
2 – Introduction
Purpose
This manual provides the parts list for the Satellite 215Q/216Q system. Using part numbers
when ordering will speed up your order and reduce the possibility of the wrong parts being
shipped. When ordering replacement parts, ensure that you give the complete name and part
number as shown in the relevant parts list. It would also help to provide the serial number of
the equipment.
Intended Users
The intended users of this manual are:
• Authorized Service Contractors (ASCs)
• Customer Specified Contractors (CSCs)
Related Reading
The following documents contain related information and may be helpful when ordering parts
for Satellite 215Q/216Q system:
Document Number
Title
GOLD Library
035251
215S/216S Satellite Parts Manual
Gasboy Commercial and Retail Pumps
PT-1956
(formerly 035287)
Satellite 215A/216A Dispensers Parts
List
Gasboy Commercial and Retail Pumps
Warranty
For information on warranty, refer to Gasboy’s Warranty Policy Statement - MDE-4255. If
you have any warranty-related questions, contact Gasboy’s Warranty Department at its
Greensboro location.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 2-1
Introduction
Abbreviations and Acronyms
Abbreviations and Acronyms
The following table contains a list of acronyms used in this manual:
Page 2-2
Acronym
Definition
AC
Alternating Current
ASC
Authorized Service Contractor
CSC
Customer Specified Contractor
CARB
California Air Resources Board
CoC
Certificate of Compliance
FCC
Federal Communications Commission
NCWM
National Conference of Weights and Measures
PC
Personal Computer
PCB
Printed Circuit Board
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Using this Parts List
Parts List
3 – Parts List
Using this Parts List
This manual is arranged from general to specific, presenting the complete unit first, then the
chassis breakdown, and lastly the assembly breakdowns. If you cannot find the part you need
from the chassis drawing, be sure to check the appropriate parts breakdown for your model.
Procedures requiring disassembly of portions of the pump/dispenser should be performed by
competent service personnel. Do not depend on the repair service of a general mechanic. Only
persons properly trained and authorized and using the appropriate manuals should service the
equipment. Do not depend on a parts manual breakdown to perform service procedures.
Manuals with service information also contain safety information relating to the procedures.
Note: Gasboy has a distributor network which services fuel dispensing and management
systems in every section of the country.
!
WARNING
To reduce the risk of electrical shock when servicing, turn off and lock out all
power to the pump/dispenser. In submersible pump applications, turn off and
lock out power to the submersible pump and any other pumps/dispensers which
use that submersible pump. AC power can feed back into a shut-off dispenser
when dispensers share a common submersible pump or starter relay. Always
turn off and lock out all power to the dispenser and submersible pumps at the
master panel and close any impact valve before performing maintenance or
service at the dispenser, including the changing of any fuel filters or strainers.
Also block islands so that vehicles do not pull up to the dispenser when the
dispenser is being serviced.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-1
Parts List
215Q/216Q Front and Side Views - Side Load (Illustration)
215Q/216Q Front and Side Views - Side Load (Illustration)
Front View
Page 3-2
Side View
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215Q/216Q Front and Side Views - Side Load (Illustration)
Parts List
215Q/216Q Front and Side Views - Side Load
Item # Description
Part Number
1
Gasket, 1/16" x 1/4", Rubatex
2
Panel, Left, Galvanized (See Note)
M05001B001
Panel, Left, Stainless Steel
M05001B002
3
Hook Nozzle
003732
4
Gasket, Nozzle Boot
026850
5
Boot, Nozzle
003338
6
Hook, Hose
003740
7
Top Cover Weld, Galvanized (See Note)
042250
®
027073
Top Cover Weld, Stainless Steel
042257
8
Roll Pin
042657
9
Stop, Eccentric
063204
10
Lever, Control
003347
11
Panel, Right, Galvanized (See Note)
M05001B007
Panel, Right, Stainless Steel
M05001B008
Panel, Front and Rear, Galvanized (See Note)
030808
Panel, Front and Rear, Stainless Steel
030807
12
Note: Specify the standard color (black, white, red) of the pump/dispenser. If it is not a
standard color, specify its serial number.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-3
Parts List
215Q/216Q Front and Side Views - Front Load Option (Illustration)
215Q/216Q Front and Side Views - Front Load Option
(Illustration)
Front View
Page 3-4
Side View
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215Q/216Q Front and Side Views - Front Load Option (Illustration)
Parts List
215Q/216Q Front and Side Views - Front Load Option
Item # Description
Part Number
1
Gasket, 1/16" x 1/4", Rubatex
027073
2
Panel, Left, Galvanized (See Note)
M05001B001
Panel, Left, Stainless Steel
M05001B002
Nozzle Boot Shroud (Painted)
041423
Nozzle Boot Shroud (Stainless Steel)
042090
Panel Assy., Galvanized
041811
Panel Assy., Stainless Steel
041816
6
Hook, Hose
003740
7
Top Cover Weld, Galvanized (See Note)
042250
Top Cover Weld, Stainless Steel
042257
Panel, Right, Galvanized, Front Load (See Note)
M05001B005
Panel, Right, Stainless Steel, Front Load
M05001B006
Panel, Front and Rear, Galvanized (See Note)
030808
Panel, Front and Rear, Stainless Steel
030807
3
4
11
12
Note: Specify the standard color (black, white, red) of the pump/dispenser. If it is not a
standard color, specify its serial number.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-5
Parts List
215Q/216Q Twin Front and Side Views - Front Load (Illustration)
215Q/216Q Twin Front and Side Views - Front Load
(Illustration)
Front View
Page 3-6
Side View
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215Q/216Q Twin Front and Side Views - Front Load (Illustration)
Parts List
215QTW/216QTW Twin Front and Side Views - Front Load
Item # Description
1
Part Number
Top Cover Weld, Galvanized (See Note)
042250
Top Cover Weld, Stainless Steel
042257
2
Gasket, 1/16" x 1/4", Rubatex
027073
3
Hook, Hose
003740
4
Nozzle Boot Shroud (Painted)
041423
Nozzle Boot Shroud (Stainless Steel)
042090
Panel, Front, Galvanized
041811
Panel, Front, Galvanized (Stainless Steel)
041816
Panel, Right, Galvanized, Front Load 215Q (See
Note)
M05001B003
Panel, Right, Stainless Steel, Front Load 215Q
M05001B004
Panel, Right, Galvanized, Front Load 216Q (See
Note)
M05001B009
Panel, Right, Stainless Steel, Front Load 216Q
M05001B010
5
6
Note: Specify the standard color (black, white, red) of the pump/dispenser. If it is not a
standard color, specify its serial number.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-7
Parts List
215Q/216Q Chassis Assembly (Illustration)
215Q/216Q Chassis Assembly (Illustration)
Page 3-8
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215Q/216Q Chassis Assembly (Illustration)
Parts List
215Q/216Q Chassis Assembly
Item # Description
Part Number
1
Reducer Bushing, Hex 1-1/4" x 1 CI
K02309-22
2
Elbow, Reducing 1-1/2" x 1-1/4" x 90° (216)
Z07941
Elbow, Discharge, 1" (215)
024895
3
Grommet, Discharge
028975
4
Bracket, Pipe Support
023872
5
Pipe TBE, 1-1/2" x 4"
R11493-90
6
Solenoid Valve, 1-1/2" Skinner®, 2 Stg. Top
Cond., 115V
067028
Solenoid Valve, 1-1/2" Skinner, 2 Stg. Top Cond., 067062
230V
7
Pipe TBE, 1-1/2" x 2-1/2"
R11493-84
8
Elbow, 1-1/2" x 90°
K46046
9
Bracket, Pipe Support
015609
10
Grommet Discharge - 1"
028960
12
Pipe TBE, 1" x 4"
R11495-98
13
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
115V
067034
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
230V
067036
14
Pipe TBE, 1" x 1-1/2" Close
R11495-20
15
Bushing, Hex Reducer
K07799
16
AC Junction Box
014168
AC Junction Box, units after serial numbers
6511869-T and 486470.
003157
17
AC Junction Box Cover
003117
18
Bracket, Lower J-Box
015812
19
Post, Corner
042255
20
Base
M04452A001PB0
21
Support, Piping
M04484A001
22
Gusset
029309
23
1/2" UNY Explosion-proof Cond Union
N16289-20
24
Brace, Frame Support
042261
25
Support, Top
042273
26
Conduit, Solenoid, 215Q, units after serial
numbers 6511869-T and 486470.
023201
Conduit, Solenoid, 216Q, units after serial
numbers 6511869-T and 486470.
023202
27
Nut, Lock
039133
28
Pipe TBE, 1-1/2" x 14-1/4"
R11493-100
29
Union, 1-1/2", 150 LB Stockham®
K12179
30
Elbow, Conduit
025045
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-9
Parts List
215Q/216Q Chassis Assembly - Front Load Option
215Q/216Q Chassis Assembly - Front Load Option
215Q/216Q Chassis Assembly - Front Load Option
Page 3-10
Item # Description
Part Number
1
Reducer Bushing, Hex, 1-1/4" x 1 MI
K02309-22
2
Elbow, Reducing, 1-1/2" x 1-1/4" x 90° (216)
Z07941
Elbow, Discharge, 1" (215)
024895
3
Grommet, Discharge
028975
4
Bracket, Pipe Support
023872
5
Pipe TBE, 1-1/2" x 4"
R11493-90
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215Q/216Q Chassis Assembly - Front Load Option
Item # Description
6
Parts List
Part Number
Solenoid Valve, 1-1/2" Skinner, 2 Stg. Top Cond., 067028
115V
Solenoid Valve, 1-1/2" Skinner, 2 Stg. Top Cond., 067062
230V
7
Pipe TBE, 1-1/2" x 2-1/2"
R11493-84
8
Elbow, 1-1/2" x 90°
K46046
9
Bracket, Pipe Support
015609
10
Grommet Discharge - 1"
028960
12
Pipe TBE, 1" x 4"
R11495-98
13
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
115V
067034
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
230V
067036
14
Pipe TBE, 1" x 1-1/2" Close
R11495-20
15
Bushing, Hex Reducer
K07799
16
AC Junction Box
014168
AC Junction Box, units after serial numbers
6511869-T and 486470
003157
17
AC Junction Box Cover
003117
18
Bracket, Lower J-Box
015812
19
Post, Corner
042255
20
Base
M04452A001PBO
21
Support, Piping
M04484A001
22
Gusset
029309
23
1/2" UNY Explosion-proof Cond Union
N16289-20
24
Brace, Frame Support
042261
25
Support, Top
042273
26
Conduit, Solenoid, 215Q
023201
Conduit, Solenoid, 216Q
023202
27
Nut, Lock
039133
28
Pipe TBE, 1-1/2" x 14-1/4"
R11493-100
29
Union, 1-1/2", 150 LB Stockham
K12179
30
Nozzle Boot Assembly (includes switch)
041415
Switch
*C04243
31
Gusset, Pipe Support Bracket
042301
32
IS Barrier Assembly
C06882
33
Junction Box
014187
34
PCB Assy., 115V
C07388
PCB Assy., 230V
C07403
Note: * Denotes that this is a sub-part used in the preceding assembly.
35
Conduit
023202
36
Elbow, Conduit
025045
37
Bracket, Nozzle Boot, Upper
042300
38
Brace, 215Q/216Q
042303
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-11
Parts List
215QTW/216QTW Twin Chassis Assembly - Front Load Option (Illustration)
215QTW/216QTW Twin Chassis Assembly - Front Load
Option (Illustration)
215QTW/216QTW Twin Chassis Assembly - Front Load Option
Item # Description
Part Number
1
Post, Corner
042255
2
Support, Top
042273
3
Support, Piping
M04484A001
4
Nozzle Boot Assembly (includes switch)
041415
Switch
*C04243
Bracket, Nozzle Boot Upper
042300
5
Page 3-12
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
215QTW/216QTW Twin Chassis Assembly - Front Load Option (Illustration)
Item # Description
Part Number
6
Brace, 215Q/216Q
042303
7
Elbow, Conduit
025045
8
Conduit, Solenoid
023013
9
1/2" UNY Explosion-proof Cond Union
N16289-20
10
Bracket, J-Box
041389
11
Conduit, J-Box/IS (right)
023009
12
Pipe TBE, 1-1/2" x 14-1/4", 215QTW
R11493-100
Pipe TBE, 1-1/2" x 18-11/16", 216QTW
R11493-102
13
AC Junction Box
003116
14
AC Junction Box Cover
003117
15
Union, 1-1/2", 150 LB Stockham
K12179
16
Base
M04452A001PB0
17
Conduit, J-Box/IS (left)
023008
18
PCB Assy., 115V
C07388
PCB Assy., 230V
C07403
19
Junction Box
014187
20
Conduit, Solenoid
023010
21
Elbow, Reducing, 1-1/2" x 1-1/4" x 90°, 216QTW
Z07941
Elbow, Discharge, 1", 215QTW
024895
Grommet, Discharge, 216QTW
028975
Grommet Discharge - 1", 215QTW
028960
Elbow, 1-1/2" x 90°, 216QTW
K46046
22
23
Elbow, 1" x
24
25
90°,
215QTW
Parts List
K02312
Bracket, Pipe Support, 216QTW
042304
Bracket, Pipe Support, 215QTW
042302
Solenoid Valve, 1-1/2" Skinner, 2 Stg. Top Cond., 067028
115V, 216QTW
Solenoid Valve, 1-1/2" Skinner, 2 Stg. Top Cond., 067062
230V, 216QTW
26
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
115V, 215QTW
067034
Solenoid Valve, 1" Skinner, 2-Stg, Top Cond.,
230V, 215QTW
067036
Pipe TBE, 1" x 1-3/4" Close Nipple, 216QTW
R11493-77
Pipe TBE, 1" x 3", 215QTW
R11495-97
Note: * Denotes that this is a sub-part used in the preceding assembly.
27
28
Nut, Lock, 216QTW
039133
Nut, Lock, 215QTW
039134
Pipe TBE, 1-1/2" x 4"
R11493-90
Pipe TBE, 1" x 4-1/2"
R11495-22
29
IS Barrier Assembly
C06882
30
Reducer Bushing, Hex, 1-1/4" x 1 MI
K02309-22
31
Gusset, Pipe Support Bracket
042301
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-13
Parts List
Switch and Conduit Assembly (Illustration)
Switch and Conduit Assembly (Illustration)
Page 3-14
Item # Description
Part Number
1
Screw Set
053500
2
Plate, Start Shaft Weld
046054
3
Plate, Switch
M04395A001
4
Start Shaft Bearing
003184
5
1/2" UNY Explosion-proof Cond Union
N16289-20
6
Conduit, Switch/AC Box units before serial
numbers 6511869-T and 486470
023153
Conduit, Switch/AC Box units after serial
numbers 6511869-T and 486470
023149
7
Elbow, Conduit
025030
8
Pin, Collar
042912
9
Handle, Spring
029363
10
Spring Retainer
048794
11
Switch Housing and Wire Assy.
064461
12
Pipe TBE, 1/2" x 1-1/8"
N16771-78
13
Retaining Ring, Truarc®
K76238-20
14
Washer, Brass
067109
15
Wave Washer
16
Bearing, Nyliner , 1/2"
011958
17
Shaft, Start
054447
18
Stop, Spacer
056809
068951
®
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Switch Housing and Wire Assembly, 064461 (Illustration)
Parts List
Switch Housing and Wire Assembly, 064461 (Illustration)
Item # Description
Part Number
1
Cover, Switch
003517
2
Housing, Switch
003773
3
Switch, PDPDT
064333
4
Stop, 4-wire
063189
5
Washer, Stainless Steel,. 328" x 19/32" x 1/1"
068606
6
Retaining Ring, Stainless Steel
049491
7
Nut, Adjusting
038569
8
Pin, Cotter
K02125
9
Shaft
054419
10
Spring
057161
11
Terminal, Wire 1/4F QC Flag
C09602
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Page 3-15
Rubatex® is a registered trademark of Rubatex International, LLC. Stockham® is a registered trademark of Stockham. Truarc® is a registered trademark of
Truarc Company LLC. Nyliner® is a registered trademark of Thomson Nyliner.
© 2005 GASBOY
7300 West Friendly Avenue • Post Office Box 22087
Greensboro, North Carolina 27420
Phone 1-800-444-5529 • http://www.gasboy.com • Printed in the U.S.A.
PT-1942B Gasboy Satellite 215Q/216Q Dispenser Parts List • November 2005
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising