Electronic Piezoelectric Basin Faucet

Electronic Piezoelectric Basin Faucet
※Special Statement※
※ The specification has been carefully proofreaded, our company reserves the right of
interpretation.
※ If this product has technical improvement in the future, we won’t make a special notice.
※ Please check specific parameters of the product with the nameplate .
※ Pictures are only for reference .
Electronic Piezoelectric Basin Faucet
SPECIFICATION
First of all, we must express our most sincere gratitude to you.
Please read the instructions carefully and use the product properly.
Designed and developed by Bravat/Dietsche Germany
INSTALLATION DIMENSION
CATALOGUE
Unit:mm
◎Introduction:
Safety Notice .................................................1~2
◎Usage:
Part Name.......................................................3
Before Use ......................................................6
Operation .....................................................7~8
MAX27
.Installation Step ....... ......................................4~6
◎Maintenance:
Daily Maintenance .............................................. 9
.
................................................10
Periodic Check
◎Fault and Elimination:
Fault and Elimination .......................................11~12
Standard .......................................................12
HELPFUL TOOLS
Pencil
Impact Drill Tape Measure
Spanner
Screwdriver
Flashlight
Teflo tape
13
Battery replacement
+
-
1.Remove the rubber stopper.
2.Get out screws with a screwdriver and remove the cover of battery box.
3. Remove the batteries from the control box, and replace them with new
alkaline dry batteries;
4.Replace the battery box cover, lock screws and stuff the rubber stopper.
5.Connect the wire.of sensor.
+
NOTE:
☆ Please note that the battery "+" and "-" pole position!
☆ Do not mix old and new batteries!
☆ Do not use non-alkaline batteries!
☆ Please deal with waste batteries properly!
I STANDARD
Once the faucet fails, first check whether it is caused because of without water. If not caused by water,please
check the faucet according to the above“Fault and Elimination”.
After check as the specification,if the failure continues or the reason is still unknown,please close the water
valve. Then contact our after-sales service department for inspection or repair.
A SAFETY NOTICE
Please read this “SAFETY NOTICE ”carefully before use.
◆ Having read the book, please be sure to save it to a place you can often see.
◆ In order to let you use this product safely, and avoid the risk of danger and damage to property
caused by you or others, a variety of markers are used in this specification.
◆ Mark and its meaning as follows:
Mark
Warning
This indicates if ignore the mark’s contents, the wrong operation may lead
to death or serious injury.
Attention
This indicates if ignore the mark’s contents, the wrong operation
may lead to injury or loss.
◆ Classify the type of contents with the following marks.
For maintenance service,please make clear these projests:
1.Products Name
: see the following "specification" description
2.Type
: see the following "specification" description
3.Fault Phenomenon : much detail as possible
4.Install Date
: Day,Month,Year
5.User Name
: name, address, telephone number
Type
Supply Voltage
Static Power Consumption
Power Consumption
Dynamic Power Consumption
Minimum Pressure (Dynamic)
Maximum Pressure (Static)
Hot Water Supply Temperature
Available Water
Water Supply Pressure
Available Environment Temperature
Induction Way
Length of Control Box Power Cord
Length of Control Box Control Line
Length of Sensor Control Line
Water Flow
Connecting Thread Sizes of Water Supply Hoses
Using
Protection Level
用途
Dismantlement Forbidden
Prohibited Contents
Must Do
Mandatory Contents
◆According to different numbers of products, maps and actual product shape is different.
Warning
Do not use a loose outlet,it may result in a fire or electric shock.
D650C
AC
Dry Battery
Input 100-240VAC,Output 6V/1A No.5 (1.5V*4=6V)
About 0.001W
About 0.8W
Do not splash water to the plug or functional parts,that may result in a fire or
electric shock.
Forbidden
0.12Mpa
0.8Mpa
70℃-75℃
Tap Water or Potable Well Water
0℃-45℃
Capacitance Type
550mm
550mm
Do not use a power which is not the specified power supply (100 ~ 240VAC) ,
that may result in a fire.
Do not bend the power cord, place heavy objects or other brutal actions,that may
lead to fire.
Do not exceed the rated power of outlet or cable apparatus when using.
100~240VAC The octopus cable beyond the rated power may cause a fire due to fever.
No-contact
Do not reform the power cord,that will cause a fire or electric shock.
Don't contact the plug with wet hands,and don’t touch the plug when it thunders,
that may cause an electric shock.
900mm
12L/Min
G1/2,M28
Public Places and Residential Wash Room
When you pull the power supply plug, you must grasp the plug body.
If you pull the power cord, you may damage the plug or the power cord and cause
a fire or electric shock.
IP
Must Do
12
Meaning
Clear the dust attached to the pins of the plug regular (1 per month).
The dust may result in a fire or electric shock. Please pull off the power plug, and
wipe it with a dry cloth.
1
触控屏表面是否有障碍物
清除障碍物
H FAULT AND ELIMINATION
! Warning
The water supply temperature must not exceed 85 ° C.
If more than 85 ° C, it may shorten the faucet’s life, and damage it.
The hot water may scald you and the water leakage may soak your property.
In addition, in order to prevent burns caused by wrong operation ,the water temperature of 60 ℃ is
recommended.
Do not directly touch the supply valve and pipeline on the hot water side.
Forbidden The higher supply temperature may cause burns.
Do not install non-structural parts or remove the parts of our product for reform.
That may cause a malfunction or electric shock.
And that operation may affect the product ‘s performance, make you injury, and bring you a
property loss by leaking.
Water places Forbidden
Do not install the product in bathrooms or other damp places.
That may result in a malfunction or electric shock.
Dismantlement Forbidden
Never disassemble, repair or reform it.
That may result in a fire or electric shock.
Turn off the supply water valve before clean the aerator .
Hot water may spray out and burn you, or bring you a property loss by leaking.
Must Do
Check the loose parts regularly (2 times a month).
The parts may be damaged with age and wear,leading burns,injuries or property loss by leaking.
When the spout body is loose, tighten the nut below it.
In order to ensure the safety of the check valve, you need to be replaced it periodically (see P10).
If the check valve can not work normally, it may caused by countercurrent or other unknown
reasons according to the different situation.
The following situations are not faults, please check the following items before repairs.
If you still can not return to normal, please contact the company which install the product for you,
vendors, or place of business.
Before request for repairs
Phenomenon
No Water
whether the surface of touch key is dirty
clear the dirty
whether obstacles on the surface
clear the obstacles
whether water supply valve is fully open
open the valve
whether plug has been inserted into outlet
insert the plug
whether the connector is firmly inserted
是否正在停电或者停水
whether
are blackouts or without water
insert the connector
whether aerator is blocked by waste
clean the aerator
P8
whether the surface of touch key is dirty
clear the dirty
P8
whether the water supply valve is fully open
fully open the water supply valve
P8
whether the aerator is blocked by dirty
clear the aerator
Water cann’t
clear the obstacles
P8
be stopped whether obstacles on the surface
After check above parts,if you still cann’t stop the water,please close the water supply valve.
Small Flow
In the event of emergencies, such as water leaks or cann’t be stopped,follow the points below
close the stopcock as the following picture.
Turn off cold and hot water inlet valve. If you still cann’t stop the water ,
please close the master supply valve.
Master
Valve
Do not use the product outdoor or in freeze place.
That may cause parts damage, resulting in a property loss by leaking.
The repairment for damage caused by freeze is not for free,even during its shelf life.
Do not block the woking spout.
The infiltration of water from the spout body, may cause a property loss by leaking.
P8
P8
等待恢复
wait for recovery
To ensure proper use, the supply pressure of cold water must be higher than or equal to the hot
water .If not,you’ll be unable to adjust the right temperature.
Forbidden
Page
Method
Please Check
Valve
Red light flashes when water flowing
Battery exchange period (low battery)
1.Weak: when the battery voltage is low
Do not force or impact the product ,that may damage the parts which may hurt you and lead
malfunction.
(1) When the battery voltage is lower than 3.6V, the red light will
flash with a frequency of once per second.
(2) When the battery voltage is not enough to drive the
electromagnetic valve,all electromagnetic valves will keep in closed.
Unused for long periods of time, please pull down the plug to avoid malfunction or other
unpredictable accidents.
Pull off Plug
2.Cut-off: Batteries are no power or the external power supply is
cutted off,all electromagnetic valves will keep in closed .
Confirm that the power plug has been used silicone for waterproofing treatment.
Touch screen’s lamp
Note: standard life for batteries: 4,000/month, about 2 years.
The life of poor battery is less 2 years in the same working conditions.
If that please change new dry batteries.
2
11
G PERIODIC CHECK
For safe and comfortable use, please check parts as the following examples.
No Leakage,
No Loose!
● Leakage Inspection (2 per year)
Confirm whether water is around the faucet.
The parts may be damaged with age and wear,leading burns,
injuries or property loss by leaking.
B PART NAME
◆ According to different numbers of products, maps and actual product shape is different.
Spout Body
Aerator Spanner
In the water leakage, please turn off the master valve, and require
installation company, sales shops or the sales offices.
Lock Nut
● Loose Checks for Spout Body and Control Box (2 per year)
Confirm whether spout body and control box is loose.
If you continue to use the loose parts,the pipes may leak.
When the spout body is loose, tighten the nut below it.
●Water temperature (1 per month)
Please rotate the knob for adjusting hot and cold temperature for
4 or 5 times.
Knob
Unused for long periods of time, control box may attach thermonatrite,
so as to damage the temperature adjustment function.
Strap
Braided Hose
Male connector of the power cord
Male connector of control line
●Cleaning for the power plug (1 per month)
Clean the dust on the power plug. Too much dust likely make the
outlet damp that may put it in poor insulation and cause a fire.
Female connector of the power cord
Female connector of control line
Capacitive induction control box
Pull down the plug and wipe it with a dry colth.
Knob
Check Valve
(two for cold and hot)
● Parts which need a regular replacement
For safe and comfortable use, it is necessary to change the
following parts regularly.
Power Supply
Replacement for check valve
If the check valve cann’t work normally, it may result in leaking or
other unexpected accidents.
If you need to replace check valve, please ask installation shops or
sales shops for help.
10
3
C INSTALLATION STEP
F DAILY MAINTENANCE
Installation for Control Box
Aerator Maintenance
Rubber stopper
1.Close the water supply valve.
1.(a)Remove the rubber stopper.
(b)Get out screws with a screwdriver and remove the cover
of the battery box.
Aerator Viscera
+
-
NOTE:
Don’t remove the cover with force to avoid the battery box falling,
so as not to cause wire breakage or welding points off.
+
Cover Screw
3.Wipe away the dirty in the aerator with things like brush.
Aerator Spanner
Way of turnning off water : manual way or automatic delay way.
(1)manual way: when the water is spouting, touch the key for
one time to stop the water.
9
2 3
7 8
Touch Key Maintenance
456
NOTE:
1.Either manual or automatic delay way ,the red ,orange and blue
light will put out at the same time when water is stopped ,and then
step into the "standby" state.
2.There’s need to restart the power supply or battery, the dynamic
settings of SW1 delay time (0-9 paragraphs) can take effect.
SW1 Rotary Switch
Touch Key
Touch key cann’t have a actual induction if some dirty is attached
it’s surface.
Maintain Touch keys regularly as one time of half a year.
Be careful not to hurt the surface.
3
Reset Switch
4
4.(a)Put 4 batteries(NO.5) into the battery box correctly, according
to the "+", "-" position on the batteries.
(b)Replace the cover and lock it .
1. Close the water inlet valve.
☆ Both hot and cold inlet valve must be closed.
2. Use a cotton swab with little cold or warm water to clean the
touch keys.
☆ If the dirty is difficult to wipe away,you can use the cotton swab
with some neutral detergent toclean the touch keys, then clean
them with water.
NOTE:
3.You can also turn off the water manually in automatical delay
way.
3.Click the reset switch, the whole circuit is automatically reset
to the first electric state; circuit will carry out self-examination,
and for indicator’s action please refer to the state when the
machine is powered on.
4. reinstall the aerator to spout body.
At first install and thread the aerator with hands, then tighten it with
aerator spanner.
5.Open water supply valve.
☆When the installation is completed, confirm whether there is water
leakage from the outside from its lateral.
(2)automatic delay way:You can set the delay time from 0-9
with SW1 Rotary Switch.
0: turn off the water with hands 1:delay 5 seconds
2: delay 10 seconds 3: delay 15seconds 4: delay 20 seconds
5: delay 30 seconds 6: delay 45 seconds 7: delay 60 seconds
8: delay 90 seconds 9: delay 120 seconds
When delay time is over, water will be stopped immediately.
01
2.Insert aerator spanner into the groove,or get out aerator spanner
from spout body.
Be careful not to hurt the aerator surface.
Use a cloth for maintenance
1. When there is a slight stain,wring out the soft colth soaked in cold or warm water,and use it to clean the
spout body and touch keys
2.When there are heavy stains,use a soft cloth with some diluted neutral detergent to clean them,then use a
soft cloth with water.
NOTE:
Use a non-abrasive wax to protect the surface of the product, such as car wax.
Don’t use the following things that may damage the surface of spout.
Acidic detergent, Chlorine bleach, alkaline detergent
Nylon bristled brush, Brush broom, Brush
+
-
+
4
NOTE:
The position of "+", "-" on the batteries must be matched with
the box.
NOTE: The plug and control box mustn’t dip water, it may cause a fire or electric .
9
Static selection of cold , warm or hot water:use Cycle key to
select the way of water supply. In the standby mode:
(1)Touch the key for once, the blue lamp flashes.Touch again to
spout cold water ,and touch the third time to close water.
5
Male Connector of power cord
5.(a)Connect the female connector of the power cord with its
male connector, tighten the nut.
(b)Connect the female connector of the control line with its
male connector , tighten the nut.
(2)Touch the key for once,the orange lamp flashes.Touch again to
spout warm water ,and touch the third time to close water.
(3)Touch the key for once,the red lamp flashes.Touch again to
spout hot water ,and touch the third time to close water.
NOTE:
Make sure the power is closed before installation.
Must choose the right joints to prevent wrong connection
which may lead rupture of the metal column.
Female
Connector
(4)Touch the key for once,the blue lamp flashes.Touch again to
spout cold water ,and touch the third time to close water.
NOTE : the above static cycle mode (the keys to Cycle or open) is
controlled by the automatic delay way.
Cold
Warm
6
Nut
Hot
Make sure the power and the supply Equipments are closed
before installation.
Braided
Hose
Dynamic selection of cold , warm or hot water: use cycle key
to select the way of water supply. In the standby mode:
Touch the key for once, blue lamp flashes,and cold water spouts.
Touch the key again,yellow lamp flashes,and warm water spouts.
Touch the key the third time,red lamp flashes,and hot water spouts.
Touch the key the forth time,blue lamp flashes,and cold water spouts.
Cold
6.Lock the nut of cold braided hose onto the cold water
supply valve.Lock the nut of hot braided hose onto the hot
water supply valve.
Hot
Valve
Installation for Faucet
The water circulate as these steps.
Control Line
NOTE:
1.The above dynamic cycle mode (the keys to Cycle or open) is
controlled by the automatic delay way.
2.If you shut down it or open it for the first time,it will spout cold
next time you open without memory.
cold water
warm water
Braided
Hose
1.(a)Thread the shank and braided hose below the faucet.
(b)Tie the control line with braided hose together.
Strap
Shank
hot water
2.(a)Put the washer in the mounting groove at the bottom of the faucet.
(b)Insert the faucet into countertop or the mounting hole.
Washer
Way of closing water: manual way or automatical way
The manual way can also be used into the process of automatic way.
1.manual control way: when the water is spouting, touch the key
for one time to stop the water.
2.automatic delay way:see the installation steps of 4-2.
3
Rubber
Washer
3.Set the rubber washer , washer and lock nut through shank,to make the
faucet cover the mounting hole.
Washer
NOTE:
Don’t over tighten the nut to avoid the connection cracking.
Lock Nut
8
Must install rubber washer to prevent leakage.
5
E OPERATION
Temperature adjustment knob
4
Male connector of control line
Rotate knob clockwise for cooling, counterclockwise for warming.
4.(a)Lock the nut of Braided Hose onto the connector
of control box.
(b)Connect the contrl line with the connector of
control box.
NOTE:The supply temperature of hot water must be in the range
of 60 ℃ ~ 85 ℃.
Due to the different conditions of water pressure or water
temperature, the water temperature will be different, so adjust the
right temperature you need.
Knob
NOTE:
When the supply temperature of hot water is too low or the
pressure is too small,you may cann’t get the preset temperature,
even you fully rotate the knob to the hot water side.
Make sure the power and supply equipments are closed
before installation.
Must choose the right joints to prevent wrong connection
Female connector
of control line which may lead rupture of the metal column.
D BEFORE USE
Male connector
of power cord
1.Connector confirmation
(3)Red lamp needs 2.5 seconds to light up slowly (brightness from
low to high within 2.5 seconds then off).
Cycle Key
Key
Whether the connector is connected.
Confirm connector of power are firmly connected.
Confirm connector of control box are firmly connected.
Female connector
of control line
Make sure all lines are connected correctly.
2.Battery box confirmation
Whether the battery is placed correctly.
+
Put 4 batteries(NO.5) into the battery box correctly,
according to the "+", "-" position on the batteries.
-
+
3
3.Power confirmation
Lamp
Touch Key
6
Orange
Lamp
Male connector
of control line
Female connector
of power cord
Blue
Native power: circuit will detect itself, tests of lamps as follows:
(1)Blue lamp needs 2.5 seconds to light up slowly (brightness from
low to high within 2.5 seconds then off).
(2)Orange lamp needs 2.5 seconds to light up slowly (brightness
from low to high within 2.5 seconds then off).
Whether the power supply is turned on.
When 100 ~ 240V AC power supply is used,please
insert the plug firmly into the end of outlet .
Red
NOTE: All solenoid valves are closed during the detection.
The blue,orange and red lames will keep in the standby state of
"no lights" after that 2.5 seconds.
1.Use the human touch piezoelectric potential difference sensor A / D chip 8bits processor
to control signals
2.Piezoelectric sensing response time: 100ms-120ms
3.Piezoelectric sensing input sensitivity: 10uV
4.Circuit operating temperature: -40 ℃ -85 ℃
5.Lights meaning: blue light: cold water orange lights: warm water red light: hot water
6.The reaction time of spouting water: 1 seconds or less
7.The life of electromagnetic valve : 500000 times at least
8.Low battery state: less than 3.6 VDC + / - 0.15 VDC per second ,you need to change the batteries
when red lamp flash for once
9.Temperature control: Cycle key to control Cold ,warm water and hot water.
10.The whole current consumption in standby state:120uA-130uA
11.The whole current consumption in working: 60mA
12.Electronic control keys: double bond
13.the highest pressure to bear:3.5Mpa
TIPS
NOTE:
Do not block the working spout.
The water leakage from spout may bring you a property loss by leaking.
For perception within about one minute after the power
is turned on, the indicator will flash,this is not a
malfunction (the indicator will stop flashing in about one
minute) (see P7).
7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising