kr.3 sliding door locking device

kr.3 sliding door locking device
Drive:
Release:
Security
Level:
Manual
Individual
and/or Gang
Medium
FOLGER ADAM LOCKING DEVICES
KR.3 SLIDING DOOR
LOCKING DEVICE
Description______________
Type KR.3 devices are medium security,
sliding cell door locking devices for use
with doors not exceeding 300 pounds.
Applications_____________
KR.3 devices are applicable to any
multiple cell or inmate room door
situation requiring selective, remote,
electrical unlocking and manual
movement of the door either open or
closed.
Functions________________
Unit unlocks selected individual doors
from a remote push button. A door
starter then opens the door(s) a few
inches.
Doors opened or closed manually
automatically snaplock and deadlock.
In event of emergency or power failure,
gang unlocking is accomplished in a
remote, mechanical release cabinet.
Doors are then opened the remainder
of the way by hand.
Locking System__________
Upon closure, each door automatically
deadlocks at two concealed points at
the top and bottom rear edge of the
door. Upon opening, each door
automatically deadlocks open at the
front edge of the door. Locking
components are not exposed or subject
to tampering. Components do not
project into the door opening.
Testing__________________
Standard Features_______
Type KR Series have been in service
since 1962, and has been tested to
500,000 cycles.
Motor voltage – 120 VAC.
Plug-type connectors – Simplified
wire harness installation.
Individual motor unlocking – Each
door is unlocked by its own motor.
For more information, please call 210.533.1231.
FA Rev. 02-10
D17
FOLGER ADAM LOCKING DEVICES
Drive:
Release:
KR.3 SLIDING DOOR
LOCKING DEVICE
Heavy duty construction – KR.3
devices are ruggedly built for a range
of detention environments.
Tamper-resistance – All openings in
housings are baffled to resist inmate
tampering.
Selective unlocking – Each door may
be unlocked by an individual control
switch, group-unlocked with an alldoor switch, or individually released
through a port.
Sloped-top housing – Resists hiding
of contraband.
Flat-top housing is provided where
the device must install close to the
ceiling.
Fixed hinge cover – Allows
maintenance without lifting heavy
covers off the device.
Automatic deadlocking – When fully
closed or open, independent top and
bottom locking points on the rear of
each door automatically deadlock.
Indication switch – Monitors the
deadlocked condition of both locking
points and mid-travel.
Two point locking mechanical
release cabinet – A three-position
lever handle or crank handle is
provided.
Lever provides:
1. Electric operation – Door control
from a remote location.
2. Release ports open – Opening of
individual release ports. Doors to
be individually released at the
door with a removable handle.
Covers are also individually
released from the port.
3. Emergency unlock – Gang
release of all doors in event of
emergency or power failure.
Full length wire tray – Simplifies
routing of electrical wire/harnesses.
Runs the full length of the housing.
Removable end battens – Simplify
installation of wire harnesses.
Locked open feature – Permits doors
to be held open and immovable.
Optional Features________
Motor voltage – 24 VDC.
Mechanical release column –
A release column containing a
No. 82 Deadlock may be added to
provide local mechanical locking and
unlocking by paracentric prison key.
Two-position motor (MC) – Unlocks
the door by an electric switch. Once
unlocked, the mechanism remains in
the unlocked position until electrically
selected to relock. The door may then
be deadlocked in either the open or
closed position.
Key switch – An electric key switch
may be added to the above column
for local electric control.
Inmate control feature – Release
columns may be equipped with an
inmate push button on the cell side,
and a key cylinder on the outside.
Inmates may exit by pressing the
push button, and reenter using a key.
Feature may be canceled at a remote
console or other control point.
Security
Level:
Manual
Individual
and/or Gang
Medium
Electrical/mechanical control
cabinet – Electrical switches may be
ordered to provide control of each
door in addition to mechanical
function. These switches may be built
into the mechanical release cabinet,
or located remotely as needs dictate.
1. Individual Push Button Unlocking.
2. Group Switch – Provides group
unlocking.
3. Power Cut-off Switch – Cuts
electric current to controls.
Indication lamps may be installed in
conjunction with switches to show
deadlocked closed or open status of
each door. When used, indication is
as follows:
Red – Open or locked open.
Green – Deadlocked closed.
Custom graphic consoles – In many
cases, it may be desirable to separate
electric controls from the mechanical
cabinet located near the cells. For
larger installations, or those with
particular needs, custom-built
consoles may be easily provided with
floor plan graphics screened on the
control panel, and an array of
specialized features.
Cell line cable – For applications
using a series of locking devices, a
cell line cable may be specified to
interconnect terminal strips in the
mechanical control/release cabinet to
a plug connector at the door
operating unit. Simplifies routing of
wire, and saves installation cost and
time.
G90 galvanized finish available.
P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211
Web: www.SouthernFolger.com Email: info@southernfolger.com
D18
Printed in USA
FA Rev. 02-10
Drive:
Release:
Security
Level:
FOLGER ADAM LOCKING DEVICES
Manual
Individual
and/or Gang
KR.3 SLIDING DOOR
LOCKING DEVICE
Medium
Rollers: Cold formed steel.
Rollers are mounted on hardened
ball bearings protected by
internal grease shields.
Specifications________
Unlocking system –
Type: Manual door movement.
Motor: 120 VAC, 60 HZ, or 24
VDC.
Hanger and guides: 1/4" thick
steel.
hinged to cover.
Vertical lock column housing:
7-gauge steel.
Finish: USP.
Mechanical release column
(optional): 7-gauge steel.
Mechanism housing/covers –
Wire tray: 16-gauge steel tray.
Housing: 7-gauge steel.
Front receiver: 10-gauge steel.
Housing covers: 10-gauge steel,
Finish: USP.
Typical KR.3 slope-top elevation.
Left hand (LH) as shown.
Right hand (RH) opposite as shown.
Dimensional Data_______
Note: Dimensions are for information
and planning purposes only, and should
not be used as templates.
The illustration shown is intended for general
information and planning purposes only. Folger
Adam locking devices are fabricated to the
design of the facility.
For more information, please call 210.533.1231.