Ammara Designs 14-05 Installation Instructions

Ammara Designs 14-05 Installation Instructions
14-05-PC
14-05-SN
14-05-PN
14-05-BZ
Installation Instructions
Series #14
Single Handle Floor Mounted Tub Filler
For easy installation of your faucet you will need:
To read all the installation completely before beginning.
To read all warnings, care, and maintenance information.
15122806
14-05-PC
14-05-SN
14-05-PN
14-05-BZ
Installation Instructions
1
2
FRONT
SEALING TAPE
HOT
HOT
FRO
N
COLD
T
COLD
Locate the position on the wood support where the
MANIFOLD MOUNTING BASE will be installed. Use the
MANIFOLD MOUNTING BASE as a guide to mark the four
mounting hole locations.Drill pilot holes if required.
Secure the MANIFOLD MOUNTING BASE to the WOOD
SUPPORT with SCREWS provided.Verify that the
MANIFOLD MOUNTING BASE is level and then fully
tighten SCREWS .
Sweat together Hot and Cold Supply assemblies. Apply
sealing tape to threaded connections. With the maximum
and minimum measurement in front, the hot supply is to be
installed on the left inlet and the cold on the right as shown
in the image above.
Note: The inlets are marked hot and cold on the bottom of
the MANIFOLD MOUNTING BASE for reference.
4
MIN
FINIS 10"
HED
D SU
FLO
OR L
PPO
RT
INE
WOO
FLOOR JOIST
MIN
MIN 2 11/16
MAX 4 13/16
3
2"
4
"
-12
10"
FRO
NT
ROUND BUBBLE LEVEL
HOT
COLD
Adequate floor support is required. The WOOD SUPPORT
must be a minimum of 2" (51mm) thick by 10" (254mm)
wide. 2x6 lumber is NOT adequate for this application.
WOOD SUPPORT must be located with in the MIN. and
MAX. arrows that are marked on the front of the PLASTER
GUARD .
IMPORTANT: Use a ROUND BUBBLE LEVEL to level the
WOOD SUPPORT . The WOOD SUPPORT must be
perfectly level. Secure WOOD SUPPORT to floor joists.
Check for level again.
15122806
Finish all Hot and Cold supply connections to the
MANIFOLD MOUNTING BASE .Loosen the two PLASTER
GUARD SCREWS and remove the PLASTER GUARD.
Make sure the two TEST PLUGS are tight, but do not over
tighten.Turn on water supplies and test for leaks.
Turn off water supplies. Replace PLASTER GUARD and
attach with SCREWS.
2
6
5
FINISHED FLOOR
FINISHED FLOOR
ROUGH FLOOR
Complete the installation of the Finished Floor. Tile as close When you are ready to install the TUB FILLER cut the
to the PLASTER GUARD as possible.Caulk between
exposed part of the PLASTER GUARD flush with the
Finished Floor and PLASTER GUARD.
finished floor. Be careful not to damage the floor.
7
8
6mm HEX WRENCH
38 5/8
C
N
N
Z
O-RING SEALS
6mm HEX WRENCH
REMOVE PLASTIC CAP
FRO
N
T
FRO
N
T
FIGURE “A”
FIGURE “B”
Remove PLASTIC CAP from bottom of the TUB FILLER.
Before final installation, check that all sealing surfaces are
clean and that the two O-RINGS are installed in the
MOUNTING ADAPTER.Install the MOUNTING ADAPTER
into the MANIFOLD MOUNTING BASE.Install the four
MOUNTING SCREWS and WASHERS through the
MOUNTING PLATE and into the MANIFOLD MOUNTING
BASE. Do not tighten.Rotate the TUB FILLER right or left
to align with Tub.Tighten MOUNTING SCREWS supplied
with 6mm Hex Wrench to secure TUB FILLER.
Turn off water supplies. With a wrench remove the center
TEST PLUG as shown in Figure A. If the TEST PLUGS
cannot be removed in one piece as shown in Figure A, the
lower half will have to be removed using the supplied 6mm
Hex Wrench as show in Figure B.
Repeat step for the second TEST PLUG.
3
15122806
9
10
1
N
APPLY SEALANT
FOAM PROTECTOR
6mm HEX WRENCH
A
2.5mm HEX WRENCH
Turn on water supplies and check all connections for leaks.
Check MANIFOLD connections for leaks.Remove foam
B
protector and apply sealant to under side edge on
ESCUTCHEON . Slide ESCUTCHEON down to finish floor. Mount handheld bracket onto spout base. Tighten using
Press into place.Clean up excess sealant.
supplied hex wrench.
11
12
Attach hose to spout and handheld shower.
Once hand shower is attached turn on TUB FILLER and
test the diverter
Installation is complete.
15122806
4
14-05-PC
14-05-SN
14-05-PN
14-05-BZ
10
Replacement Parts
NO.
1
2
3
4
5
6
7
8
9
10
11
12
Description
Hand Shower
Aerator Assembly
Diverter Knob Assembly
Hand Shower Hose
Hot & Cold Supply
Mounting Base Screw
Mounting Assembly
6mm hex wrench
Escutcheon
Hex screw and Key
Finished Cartridge Dome
Handle Plug & Screw
Handle
13
14 Cartridge Nut
Part No.
5F0M0178
5Q0M0025PL
9Q241700
51014603
5G0M0237CC
5T0F0143NT
9Q221900NT
5T4000400ZZ0
9Q241800
9Q241900NT
5L0P0120
9Q1229
9Q241500
15 Cartridge
16 Hand Shower Outlet
17 Diverter Cartridge
5D0M0041PL
5T1A0003AL
1
13mm HEX WRENCH
17
16
15
2
14
3
13
4
12
5Y0011100 0
5MD0M0006
2.5mm HEX WRENCH
11
10
9
5
6mm hex wrench
8
7
6
5
15122806
14-05-PC
14-05-SN
14-05-PN
14-05-BZ
5
Applicable Standards/Codes
IAPMO certified to meet or exceed the following:
Installation Dimensions
11 1/4
10 3/8
8 1/4
3 11/16
5 1/16
3 3/8
30 9/16 32 11/16
35 3/8
1 15/16
5 1/8
3 11/16
4 9/16
15122806
32 5/16 34 7/16
4 15/16
MAX 4 13/16
1 9/16
38 5/8
8 7/16
24 13/16 26 15/16
2-1/2-14 NPT
7
4
1 5/16
MIN 2 11/16
8 1/8
C
to
F
T
T
c
lo
H
R
6