Heated hose JH3F and JH3FR
Sampling Conditioning Systems
Process Analytics
System Integration
Gas Generators
FTIR-Analysers
conditioning systems
Heated hose JH3F and JH3FR
FEATURES
Customized construction
Robust construction
Excellent isolation
Rugged outer protection
Long lifetime
JH3F witn non replaceable core
JH3FR with replaceable core
APPLICATION
The heated hose series JH3F has especially been
developped for the gas analysis technology. The
flexible heated hose transports the sample gas from
the sampling point to the sample gas conditioning
unit. The heated JH3F keeps the temperature of the
sample gas above the water and acid dew point and
therefore avoids condensation and ensures that none of the gas components are discharged or lost.
The heated hose is available in different constructions and manufactured according to customer‘s specifications.
TECHNOLOGY
The basis of the heated hose is a smooth PTFE hose with one braided layer of stainless steel wire,
which ensures high flexibility and is used as a bend
protection. The stainless steel wire is wrapped with a
PTFE isolated heating conductor, which is protected
against humidity and is used for an optimum temperature distribution.
A reinforced thermovlies is used as a thermal isolation
and ensures low heat losses. As an outer protection
an abrasion-proof, UV resistant, non halogen and
non-slip PA corrugated hose is used. A thermo element type K (NiCr-Ni) or a PT100 is used as a temperature sensor.
FEATURES
The electrical and thermal construction of the heated
hose allows operating temperatures of up to 200°C.
JCT can offer a multitude of end configurations for,
which ensure easy integration in an existing analysis
system. The heated hose JH3FR features a replaceable inner core, which allows an easy replacement
at site in the case of contamination. Typical applications for the heated hose series JH3F are emission and
process monitoring for mobile application and for fixed
installation.
Page 1
TECHNICAL DATA
Specification of end configuration
Side 2 (without cable)
Side 1 (feed cable)
Type
see
note
see
note
JH3F
JH3FR
p
F
A
hard cap
p
RSL
G
hard cap
(stepped)
B
p
p
RSL
p
H
C
silicone cap
p
RSL
p
I
D
PG36
p
RSL
P
J
E
moveable PG42
P
RSL
Note:
p … PTFE core 200 mm protruded
RSL … SS 316 stubs, tube connector
JH3F with non replaceable PTFE core
JH3FR with replaceable PTFE core
DIMENSIONS OF HARD CAPS
DIMENSIONS OF SILICONE CAPS
NON REPLACEABLE CORE - TYPE JH3F
NON REPLACEABLE CORE - TYPE JH3F
Diameter of
heated hose
Length
Outer diameter
without cable
(Type F)
Outer diameter
with feed cable
(Type A und B)
Diameter of
heated hose
Length
DN 4/6 mm
DN 6/8 mm
110 mm
51 mm
75 mm
DN 4/6 mm
110 mm
51 mm
75 mm
DN 6/8 mm
REPLACEABLE CORE - TYPE JH3FR
Diameter of
heated hose
Length
DN 4/6 mm
DN 6/8 mm
Outer diameter
without cable
(Type H)
Outer diameter
with feed cable
(Type C)
89 mm
46 mm
66 mm
89 mm
46 mm
66 mm
REPLACEABLE CORE - TYPE JH3FR
Outer diameter
without cable
(Type F)
Outer diameter
with feed cable
(Type A und B)
Diameter of
heated hose
Length
Outer diameter
without cable
(Type H)
Outer diameter
with feed cable
(Type C)
110 mm
51 mm
75 mm
DN 4/6 mm
89 mm
46 mm
66 mm
120 mm
54 mm
79 mm
DN 6/8 mm
89 mm
46 mm
66 mm
SPECIFICATIONS
SPECIFICATIONS
Operating temperature
Max. 200°C
Feed cable
3 m long with 7-pin connector
Max. operating pressure
10 bar
Connector types
Ambient temperature
-40°C - +60°C
Application
Mobile and fixed installation indoor
and outdoor
7-pin connector for connection of temperature controller HT43 and HT55
HANQ8-connector for connection of
temperature controller HT41
Power supply
230 VAC or 115 VAC
Core
PTFE; Optional: PFA
Power consumption
100 W/meter
Heating conductor
Construction according to DIN,
protected against humidity, with
braided protection
Length
Up to 50 m
Outer diameter
DN 4/6 mm: 42 mm
DN 6/8 mm: 42 mm
Minimum bending radius
JH3F / JH3FR
DN 4/6 mm: 50 mm / 100 mm
DN 6/8 mm: 75 mm / 120 mm
Thermal isolation
Thermovlies
Outer protection
PA corrugated hose
End configuration
Hard caps, Silikone caps, PG36 or
PG42 (see above)
Page 2
ORDER CODE
ORDER CODE JH3F
Temperature sensor PT100
2
Temperature sensor PT100 + limiter
3
Temperature sensor NiCr-Ni
4
2 x Temperature sensor PT100
9
Outer protection PA corrugated hose
3
Without endconfiguration, core 200 mm protruded
0
Stainless steel stubs approx. 30 mm long
6
Length in dm (e.g.: 10 m = 100; 4,5 m = 045)
XXX
Diameter DN 4/6 mm
4
Diameter DN 6/8 mm
6
PTFE core
PTFE
PFA core
PFA
Power supply 230 V/50-60 Hz
2
Power supply 115 V/50-60 Hz
1
End configuration side 2 (without cable)
F
End configuration side 2 (without cable)
G
End configuration side 2 (without cable)
H
End configuration side 2 (without cable)
I
End configuration side 2 (without cable)
J
End configuration side 1 (feed cable)
A
End configuration side 1 (feed cable)
B
End configuration side 1 (feed cable)
C
End configuration side 1 (feed cable)
D
End configuration side 1 (feed cable)
E
Without calibration gas inlet
0
Calibration gas inlet 2/3 mm
2
Calibration gas inlet 4/6 mm
4
Order code
JH3F
Page 3
ORDER CODE
ORDER CODE JH3FR
Temperature sensor PT100
2
Temperature sensor PT100 + limiter
3
Temperature sensor NiCr-Ni
4
2 x Temperature sensor PT100
9
Outer protection PA corrugated hose
3
Without endconfiguration, core 200 mm protruded
0
Length in dm (e.g.: 10 m = 100; 4,5 m = 045)
XXX
Diameter DN 4/6 mm
4
Diameter DN 6/8 mm
6
PTFE core
PTFE
PFA core
PFA
Power supply 230 V/50-60 Hz
2
Power supply 115 V/50-60 Hz
1
End configuration side 2 (without cable)
F
End configuration side 2 (without cable)
G
End configuration side 2 (without cable)
H
End configuration side 2 (without cable)
I
End configuration side 2 (without cable)
J
End configuration side 1 (feed cable)
A
End configuration side 1 (feed cable)
B
End configuration side 1 (feed cable)
C
End configuration side 1 (feed cable)
D
End configuration side 1 (feed cable)
E
Without calibration gas inlet
0
Calibration gas inlet 2/3 mm
2
Calibration gas inlet 4/6 mm
4
Order code
JH3FR
Specification subject to change without notice.
JCT
PDS_E_JH3F_v1.4
Analysentechnik GmbH
Werner Heisenberg-Straße 4 A-2700 Wiener Neustadt
Tel. +43 (0) 2622 / 87201 Fax +43 (0) 2622 / 872011
E-Mail: sales@jct.at Web: www.jct.at
Page 4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising