llHGrFr-ril<r omerico corporolion StK-2 4FIn PHOTOELECTRIC/HEAT SMOI(E DEIECTOR APPLICATIONS The SLK-24FH can be used in all areas where Photoelectric Smoke Detectors are required. It is best suited for smoldering or flaming fires. The 135SFheat sensorcan initiatean alarm independently. The heat detector is UL listed for 50'spacing. HSB, HSC-4R,HSC-R,or YBA-NI sryle basesmay i'le used with the SLK-24FH.Currenr compatible devices are SLK-24F,SLK-24FL and SIH-24F. OPERATION STANDARD FEATURES o Self-restoringintegral 135Sheat sensor, 50' rating ' [.ow Profile, 1.8" high . 2 or 4 wire basecompatibility, relay basesavailable . Higtrly stable operation, RF/transient protection . Low standby crrrent, 45q4\nominal . Built-in power/alarm LED o Nondirectionalsmokechamber . Vandal resistantsecurritylocking featurre . Built-in magnetic detectorsensitivity featr-ue . Compatible with SIH-24Fionization detectors ' Meets otrtlined requiremens in the NFPAp, Irnpeaion Testingand Maintenance, Clnpter / PRODUCT SPECIFICATIONS Heat Detector Ught Source RatedVoltage '$TorkingVoltage Maximum Allowable Voltage Supervisory Current Surge Current Alarm Current AmbientTemperature 135'F Self-Restoring, Fixed Temperarure GaALAsInfrared Emitting Diode 17.6 - 33.0 VDC 15.0 - 363VDC 42VDC 45pe, @ 24 VDC 200pA @ 24 VDC 150mA @ 24 VDC 32"F to 120'F (0'C to 49"C) Color & CaseMaterial Ivory ACS SensitivityTestFeature: Magneticallyactivated dtral reed sq/itdl sensitivitytest Mounting: Referto FIA 24 YoltConventional Detector BaseData Sheet The unit is comprised of an LED light source and silicon photo diode receiving element. In a normal standby condition, the receiving element receivesno light from the pulsing light source. In the event of a fire, smoke entersthe detectors and light is reflected frorn the smoke particles to the receiving element. The light received is converted into an electronic signal.Signalsare processed in the comparator, and when two consecutive signals exceeding the basic level are received within a specified period of time, the time delay circuit triggers the SCR 'fhe switch to activate the alarm signal. StatusLED lights continuously during the alarm period, if the alarm is activatedby smoke. Vhen the alarm is activatedby heat the Status LED will not light. The fixed tempera re heat element opemtes independentlyfrom the smoke sensingchamber, and causesan alarmat the control panel when the air temperature reachesapproximately 135SF,whether or not smoke is present. ENGINEERING SPECIFICATIONS The contractor shall ftimish and install where indicated on the plans, the combination detector head and twistlock base shall be UL listed as compatible with a UL listed fire alarm panel. The base shall permit direct interchange with HOCHIKI America SLK-24F Photoelectric Detector. PRODUCT LISTINGS Underwriters laboratories: 51383 FactoryMunral: OQ3AO.AY, OV5A8.AY or O>6A4AY (rydins onhe Wifd) CSFM*: 7272-0470:707 HochakiAmerica corporation 7051 VillageDrive. BuenaPark,CA 90621-2268 Phone: 7141522-2246. Fax: 7141522-2268 TectnicalSupport 800/8456692or technkalsupport@hochiki.corn NNNlM M E Made in lhe USA /\ ./rso\ .,'9002\ r' nBgIttrEB,EDl ENGINEERING SPECIFICATIONS. continued 9LK-24FLlow sensitivity photoelectric smoke cletector, SIH-24F ionization type smoke detecto r, and/or DFE-135/ 190fixed temperatLlreheat detector. The base shall limit the alarm current avalableto detectors. Baseshall be appropnate twist-lock base HSB, HSC-4R,HSC-R,or yBA-M style. The smoke detector shall have a flashing stanrsLED forvisual supervision. \vhen the detector is acnrated,the flashing LED will latch on steady at ftrll brilliance. The detector may be resetby acnratingthe control panel resetswitch. The sensitivityof the detector shall be capable of being measured. The vandal-resistant,security locking feanrre shall be useclin those areasspecified. The locking feanrre shall be field removable when not required. It shall be possible to perfiorm a furnctional test of the detectorwithout the need of generating smoke. The test method shall simulate effects of products of combustion in the chamber to ensure testing Jf d"t".to, circuits. To facilitate installation, the detector shall be non-polayVe_d.voltage and RF transient suppression techniques shall be employed to minimize falre alarmpotential. Atxiliary SPDT relays"shallbe installed where indicated. SLK.Z4FH SENSITTWTY TEST PROCEDURE NOTE: This method of sensitivitv testing is only intended for HoGHIKI America smoke detector moclelsSIH-24F, and sLK Seriesthat contain a label which identiiies this specific feanrre. see Figure 1. Do Nor arremprro Lrserhis method of sensitivity tesring on derecrorswithout this labei. Figwr 1 BottomView of Identifring Label THIS DETECTORCONTAINS A BUILT.INSENSITIVITY TEST FEATURE TEST DEVICES Sensitiviry testing is performed with the Hochiki America Alarm Test Magner, parr Number 070G.00960,(Figure 2A) orrheHochiki America TRT-A 100 smoke Derecror Tester/Removal Tool (Figure 2B). r Figure 2A: Alarm Test Magnet TqVn Fr SideVm) Figure 28 TRT-A100Sensitiviry TestProcedure TEST PROCEDURE 1' \rith detectorwired toappropriate initiating circuit orcuffentlimited power source and with normal applied poq/er, place a magnet as shown in Figr.rre 3. 2. \Vait at least six seconds. Detector SHOULD alarmand LED shouldlightPlace magner on detector as shown in Figure 4 (opposite side). 1 4. tvait at least six seconds. Detector sHouLD Nor alarm. 5. If detector does not alarmwhen magnet is positioned as in Figure 3 or does produce anararm when lrlagnet is positioned as in Figure 4, detector is notwithii specrfied sensitivity limits and may require service' SeeTechnical Bulletin FIA-88(November,%) formore inforrnation. Fignrc f SLK-24FH: Placing the Magnet Figurc 4 SLK-24FH: The Magnet on the OppositeSide wARl\rNG: conduct testing only under Normal sundby conditions. Abnormal or Low power conditions rruly affect sensitivity Always reset power prior to testing of next unit. Magnet placement identical for all detectorswith built-in sensitivity test feanrre. Hochiki America Corporation. SIJ-24 Specificationssublect to change without notice.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising