We measure it. Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring and early warning guarantee high system availability Calculation and presentation of the humidity parameters %RH relative humidity absolute humidity and dewpoint. P2A software for parameterization, adjustment and analysis °C saves time and costs in commissioning and maintenance Display with multi-language display High-quality plastic housing Not all measurement problems can be solved with „simple“ transmitters. The testo 6651 meets special challenges. When combined with the probe series testo 660x, the testo 6651 becomes the first choice in demanding air conditioning technology as well as in many other applications. www.testo.com testo 6651 – Humidity transmitter for critical climate applications We measure it. Technical data testo 6651 Parameters General technical data Humidity Design Units Relative humidity %RH , °Ctd, °Ftd, g/m³ Material Meas. range 0 to 100 %RH Dimensions 122 x 162 x 77 mm (without probe) Weight 0.675 kg (without probe, without Ethernet module) Temperature Units Temperature in °C / °F Meas. range Dependent on probe (testo 660x) Plastic Display Display Optional: 2-line LCD with clear text line and relay status display Resolution 0.1 %RH / 0.01 °C/°F / 0.1 °Ctd/°Ftd / 1 g/m3 Inputs and outputs Analog outputs Quantity 2 channels Output type 0/4 to 20 mA (2-wire/4-wire) 0 to 1/5/10 V (4-wire) Installation Measuring rate 1/s Cable screw fitting Galvanic isolation Galvanic isolation of the output signals (2-wire and 4-wire), isolation of supply from outputs (4-wire) Standard: PG screw fitting Optional: M16 or M20 M plug connection or optional: NPT 1/2 plug connection Probe connection Digital plug connection Resolution 12 bit Other features Accuracy of the analog outputs 0/4 to 20 mA / ±0.03 mA 0 to 1 V / ±1.5 mV 0 to 5 V / ±7.5 mV 0 to 10 V / ±15 mV 500 Ω at 24 VAC/DC Protection class IP65 EMC 2004/108/EG Operation Parameterization Max. load Further outputs Ethernet Relays Other outputs Optional: module can be fitted as intermediary layer Optional: 4 relays (free allocation to measurement channels or as collective alarm with operating menu/P2A software), up to 250 V AC/DC / 3 A (NO/NC) Mini DIN for Testo P2A parameterization software Power Voltage supply 2-wire: 24 VDC ±10 % 4-wire: 20 to 30 VAC/DC Current consumption max. 300 mA Four operating buttons for display / P2A software Operating conditions Operating temperature (with integrated relay) -40 to +60 °C Without display Operating temperature -40 to +70 °C / -40 to +158 °F Storage temperature -40 to +80 °C / -40 to +176 °F With display Operating temperature 0 to +50 °C / +32 to +122 °F Storage temperature -40 to +80 °C / -40 to +176 °F Measurement medium Air, nitrogen testo 6651 – Humidity transmitter for critical climate applications We measure it. Technical data probe series testo 660x testo 6601 testo 6602 testo 6603 testo 6604 testo 6605 Type Wall Duct Duct Cable Cable Operating range Room climate probe wall mounting Climate probe duct mounting Process climate probe duct mounting for higher process temperatures Climate probe with cable Stainless steel process probe with cable for higher process temperatures Measurement parameters Humidity Meas. range*** 0 to 100 %RH Measurement uncertainty* (+25 °C)** ±(1.7 + 0.007 * mv) %RH (0 to 90 %RH) / ±(1.9 + 0.007 * mv) %RH (90 to 100 %RH) +0.02 %RH per Kelvin dependent on the process and electronics temperature (for a deviation of 25 °C / 77 °F) Selectable units %RH; °Ctd/°Ftd Reproduceability better than ±0.2 %RH Sensor Testo capacitive humidity sensor, plug-in Testo capacitive humidity Testo capacitive humidity sensor, plug-in sensor, plug-in Testo capacitive humidity sensor, plug-in Testo capacitive humidity sensor; soldered t90 max. 10 sec. Response time (without protective filter) Temperature Selectable units °C/°F -20 to +70 °C/ -4 to +158 °F Sensor Measurement uncertainty* (at +25 °C / +77 °F) -30 ... +120 °C/ -22 ... +248 °F -20 ... +70°C/ -4 ... +158 °F ±0.15 °C / 0.27 °F (PT1000 Class A) -30 ... +120 °C/ -22 ... +248 °F Pt1000 Class AA General technical data Probe shaft Plastic ABS Cable Plug Plastic ABS Probe dimensions (diameter) Probe dimensions (probe shaft length) Cable length Stainless steel FEP coated 12 mm 70/200 mm 280 mm 140/280 mm 200/500 mm – specially for duct versions 1/2m 1/2/5m Operating conditions Pressure tightness without 1 bar positive pressure (probe tip) * Other accuracies apply for wall probe length 70 mm combined with a current output (P07): Operation: 2 channels at 12 mA, without display illumination, relay off, additional measurement error to above values at +25 °C (+77°F), humidity ± 2.5 % RH **The determination of measurement uncertainty takes place according to GUM (Guide to the Expression of Uncertainty in Measurement): For the determination of measurement uncertainty, the accuracy of the measuring instrument (hysteresis, linearity, reproduceability), the uncertainty contribution of the test site as well as the uncertainty of the adjustment site (works calibration) are taken into account. For this purpose, the value of k=2 of the extension factor, which is usual in measurement technology is used as a basis, which corresponds to a trust level of 95%. PN 10 (probe tip) PN 1 (probe tip) ***For continuous applications in high humidity (>80 %RH at ≤30 °C for >12 h, >60 %RH at >30 °C for >12h), please contact us via www.testo. com. testo 6651 – Humidity transmitter for critical climate applications We measure it. 162 Transmitter testo 6651 Transmitter testo 6651 Wall probe testo 6601 Transmitter testo 6651 Cable probe testo 6604/6605 L = Probe length L–A = Probe length – length protective cal A = 35 mm Duct probe testo 6602/6603 b 122 77 a Technical drawings testo 6651 – Humidity transmitter for critical climate applications Connection plan Connection plan 2-wire technology (4 to 20 mA) 18–24 VDC 2 channels 4 to 20 mA, max. load 500 Ω (at 24 V) 0V Connection plan 4-wire technology (0 to 20 mA / 4 to 20 mA / 0 to 1 V / 0 to 5 V / 0 to 10 V) 24V + - CH1 + - CH2 + - CH3 + - 20–30 V AC/CD + - 0V 2 channels 0 to 20 mA / 4 to 20 mA, max. load 500 Ω each, 0 to 1 V / 0 to 5 V / 0 to 10 V We measure it. testo 6651 – Humidity transmitter for critical climate applications We measure it. Options / Ordering example The following options can be specified for the testo 6651: Bxx Analog output / supply Cxx Display / menu language Dxx Cable entry ExxEthernet Fxx Humidity / temperature unit channel 1 Gxx Humidity / temperature unit channel 2 HxxRelay Bxx Analog output/supply B01 4 to 20 mA (2-wire, 24 VDC), not possible with relay or Ethernet module B02 0 to 1 V (4-wire, 24 VAC/DC) B03 0 to 5 V (4-wire, 24 VAC/DC) B04 0 to 10 V (4-wire, 24 VAC/DC) B05 0 to 20 mA (4-wire, 24 VAC/DC) B06 0 to 20 mA (4-wire, 24 VAC/DC) Cxx Display / menu language C00 without display / without operating menu C02 with display and operating menu / English C03 with display and operating menu / German C04 with display and operating menu / French C05 with display and operating menu / Spanish C06 with display and operating menu / Italian C07 with display and operating menu / Japanese C08 with display and operating menu / Swedish C02–C08: Clear text language. Operating menu only available with display. * The standard scaling is supplied if „min“ and „max“ are not specified. ** Plug connection M12, 5-pin plug and socket available as accessories. *** not with code „B01“. Relay parameterization in commissioning via oparating menu (display) or P2A software Dxx Cable entry D01 Cable entry M16 (relay: M20) D02 Cable entry NPT ½’’ D03 Cable contact via M plug connection for signal and supply (for optionale relay: M20 cable entry) ExxEthernet E00 Without Ethernet module E01 With Ethernet module Ordering example Order code for transmitter testo 6651 with the following options: - 4 to 20 mA (2-wire) - Cable entry M16/M20 - Factory configuration channel 1: - %RH with scaling min 0 %, max 100 % Fxx Humidity/temperature unit Channel 1* - Factory configuration channel 2: F01 %RH / min / max F02 °C / min / max F03 °F / min / max F04°Ctd / min / max F05°Ftd / min / max F08g/m3 - °C with scaling min -10 °C/-14 °F, Gxx Humidity/temperature unit Channel 2* G01 %RH / min / max G02 °C / min / max G03 °F / min / max G04°Ctd / min / max G05°Ftd / min / max HxxRelay H00 Without relay*** H01 4 relay outputs, limit value monitoring*** H02 4 relay outputs, limit values Channel 1 + collective alarm*** - max +70 °C/+158 °F* - without relay 0555 6651 A01 B01 C03 D01 E00 F01 0 100 G02 -10 70 H00 testo 6651 – Humidity transmitter for critical climate applications Options / Ordering example The following options can be specified for the probe testo 660x Ordering example Lxx Probe version Mxx Protective cap Order code for testo 6602 with the following options: - Duct probe (-20 to +70 °C/-4 to 158 °F sufficient) Nxx Probe shaft length Pxx Probe length / length mm - Sintered stainless steel probe - Probe length 280 mm Lxx Probe version L01 L02 L03 L04 L05 Probe Probe Probe Probe Probe 6601 6602 6603 6604 6605 (Wall version) (Duct version -20 (Duct version -30 (Duct version -20 (Duct version -30 to to to to 70 °C) 120 °C) 70 °C) 120 °C) Mxx Protective cap M01 Stainless steel protective cap M02 Wire mesh protective filter M03 PTFE protective cap M04 Metal protective cap, open M05 ABS plastic protective cap, open Nxx Probe length / length mm N00 N01 N02 N05 N10 N23 Without cable (for probe 6601) Probe length 1 m (for probe 6604/6605) Probe length 2 m (for probe 6604/6605) Probe length 5 m (for probe 6605 only) Probe length 10 m (for probe 6604/6605) Probe length 0.6 m, especially for duct versions (for probes 6602/6603) Pxx Probe length / length mm P07 P14 P20 P28 P50 Probe Probe Probe Probe Probe length length length length length 70 mm (only for L01) 140 mm (only for L04) 200 mm (only for L01, L05) 280 mm (only for L01, L05) 500 mm (only L05) 0555 6600 L02 M01 N23 P28 We measure it. 0981 8234/msp/I/01.2015 We measure it. Subject to change without notice. testo 6651 – Humidity transmitter for critical climate applications www.testo.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising