mr.steam® SteamGenie®

mr.steam® SteamGenie®
mr.steam SteamGenie
Wireless Control Installation and Operation Instructions
®
®
_____________________________________________________
SAFETY AND OPERATING INFORMATION
TABLE OF CONTENTS
Safety & Operating Information . . . . . . . .1
Steam Genie Interface Module Installation .2
Steam Genie Operation . . . . . . . . . . . . . .2
Steam Genie Interface Module Operation . .3
Pairing . . . . . . . . . . . . . . . . . . . . . . . . .3
Battery Replacement . . . . . . . . . . . . . . . .3
Installing the Steam Genie Holder . . . . . .4
Troubleshooting . . . . . . . . . . . . . . . . . . .4
List of Replacement Parts . . . . . . . . . . . .4
________________________________________________
BOX CONTENT
• Steam Genie®
• Steam Genie Holder
• Interface Module
• Lanyard
• 5 ft. Interface Module Connection Cable
• 2 Interface Module mounting Screws
• Installation and Operation Instructions
CAUTION
• Ensure the steam room door is closed when using a Steam Genie. Leaving the steam room
door open during steam generator operation may result in property damage.
• Do not route any eTEMPO/PLUS, eTEMPO, eTEMPO/START or STEAM GENIE
control wiring inside conduit with power lines or close to hot water or steam piping. Doing so
may result in an inoperative or hazardous installation.
• Do not alter or modify any eTEMPO/PLUS, eTEMPO, eTEMPO/START,
eTEMPO/REMOTE or STEAM GENIE controls. Doing so may result in an inoperative
or hazardous installation.
_________________________________________________________________________________
IMPORTANT:
WARNING
states a hazard which may cause serious injury or death
if precautions are not followed.
CAUTION
signals a situation where minor injury or product damage may
occur if you do not follow instructions.
IMPORTANT NOTE:
THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY
RELEVANT TO A PROBLEM-FREE INSTALLATION.
• Set the steambathing temperature according to personal preference, however it is
highly recommended to begin steambathing at a low temperature setting to gauge
comfort and safety levels. Set the duration at 10 minutes max. To gauge comfort and safety
levels. This will allow the steam generator to heat up and begin producing steam.
• Do not install or use any eTEMPO/PLUS®, eTEMPO®, eTEMPO/START®, eTEMPO/ REMOTE® or
STEAM GENIE® controls without reading and understanding the
Mr.Steam steam generator Installation and Operation Manual (part number 101289
Revision number 10.0/08 or higher). Failure to read and understand these
instructions may result in an inoperative or hazardous installation.
• A peel and stick warning is provided with the Mr.Steam steam generator Installation
and Operation Manual. Mr.Steam strongly recommends that this warning be read and posted
in a conspicuous location near the steam room.
• Install and use the eTEMPO or eTEMPO/PLUS controls according to instructions.
Failure to install and use according to instructions will result in an inoperative
control or hazardous overheating or inadequate heating of the steam room.
• A Steam Genie used in close proximity to multiple generators, may inadvertently turn them
on. Please read the paragraph on pairing in this manual if more than one Steam Genie is used
in close proximity.
!
IMPORTANT NOTE:
As you follow these instructions, you will notice warning
and caution symbols. This blocked information is important
for the safe and efficient installation and operation of this
Steam Genie. These are two types of potential hazards that
may occur during this installation and operation:
!
WARNING
_________________________________________________________________________________
________________________________________________
!
!
• Do not operate any eTEMPO/PLUS, eTEMPO, eTEMPO/START, eTEMPO/REMOTE or STEAM
GENIE control with anything other than a Mr.Steam eTEMPO compatible steam generator.
Mr.Steam residential steam generators with serial numbers lower than 900,000 or any other
brand of steam generator are not to be operated with eTEMPO controls. Doing so may result
in an inoperative installation.
• This document contains important safety, operation and maintenance information.
Leave this document with the homeowner. Do not discard this document.
• Discontinue use of the steam generator or control if the steam generator is damaged
or otherwise not functioning properly.
PUR 100449 8/11
mr.steam®
Sussman-Automatic Corp®
43-20 34th Street, Long Island City, NY 11101
TEL: 1 800 76 STEAM FAX: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301
TEL: 1 800 72 STEAM FAX: 310 216 2944
hello@mrsteam.com www.mrsteam.com
This device complies with Industry Canada license-exempt RSS standard(s). Operation is Subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
FCC ID: KSK-104058
IC ID: 9321A-104058
FCC ID: KSK-104059
IC ID:9321A-104059
Mr.Steam: Steam Genie
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Operation is subject to the following two conditions: 1) This device may not cause harmful interface, and
2) This device must accept any interface received, including interface that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
mr.steam® SteamGenie®
Installation and Operation Instructions
_______________________________________________________________________________________________________________
Plug the Steam Genie Interface
Module cable into the Steam Genie
location on the steam generator
STEAM GENIE® INTERFACE MODULE
INSTALLATION
• Connect the STEAM GENIE INTERFACE MODULE to the generator by
plugging in the provided 5 foot cable to the STEAM GENIE INTERFACE MODULE and the Steam Genie connector on the side of the
generator as shown.
• Mount the STEAM GENIE INTERFACE MODULE in a dry, indoor location. For maximum range, the Steam Genie Interface Module should
be mounted as high as practical and away from metal that could effect the radio signal. Securing it to a nearby wood stud is ideal. The
antenna should be pointing upwards.
• With the generator powered, the red light (steam off) or green light
(steam on) should come on when plugged in. Press the TOGGLE
STEAM button to confirm proper connection.
• Press the ON/OFF button and confirm that the Steam Genie lights
match the state of the steam generator.
Red for STEAM OFF (eTempo control is off)
and green for STEAM ON (eTempo control is on).
• The yellow RF activity light on the STEAM GENIE
INTERFACE MODULE should flash each time the button
on the Steam Genie FOB is pressed.
• Test the range of the Steam Genie FOB. It may be necessary to
change the location of the Steam Genie Interface Module to improve the range. Contact Mr.Steam technical service for an optional
60 foot cable, part number 103978-60.
STEAM GENIE
INTERFACE
MODULE
STEAM GENIE
INTERFACE
MODULE Cable
NOTE: For illustrative purposes only.
The eTempo control cable is not shown for clarity. An eTempo or
eTempo/Plus must be used in conjunction with the Steam Genie.
STEAM GENIE® FOB
STEAM GENIE® OPERATION:
Red & Green Light
• When the Steam Genie FOB light is off, press the button once and the
Steam Genie FOB light indicates if the steam is on or off. When you
press the button, the light will momentarily twinkle between red
and green. A red light indicates that the steam is off and a green
light indicates that the steam is on. If you are out of range, the
lights will twinkle for about 5 seconds and then shut off.
• To turn the steam on or off, press the ON/OFF button again while the
light is illuminated. After a short delay the light will change from red
to green (steam on) or green to red (steam off).
• The light will stay illuminated for 10 seconds and then shut off.
• A blinking red light indicates that an error condition exists in the
steam generator. An error code will be displayed on your eTempo or
eTempo/Plus control. Contact the Mr.Steam Technical Service Department at 800-76-STEAM (East coast) or 800-72-STEAM (West coast)
for assistance or additional information.
ON/OFF Button
! CAUTION The Steam Genie FOB may be used in the steam
room. Do not submerge the Steam Genie FOB in water.
Doing so may result in an inoperative or hazardous installation.
2
mr.steam® SteamGenie®
Installation and Operation Instructions
_______________________________________________________________________________________________________________
STEAM GENIE® INTERFACE MODULE:
PAIRING
• The STEAM GENIE FOB and STEAM GENIE INTERFACE MODULE come
paired from the factory with address 1. The Steam Genie FOB and Steam
Genie Interface Module can be set to one of eight different addresses.
• Pairing is required if you have more than one steam generator in your
home or if you experience interference from a neighbor’s steam generator.
• You can determine the pairing of an Steam Genie FOB and Steam Genie
Interface Module by pressing and holding the ON/OFF button for 2 seconds. If you are within range of the Steam Genie Interface Module, the
green light will flash from 1 to 8 times depending on the address. To
change the address of the Steam Genie Interface Module, you must
enter pairing mode.
• To enter pairing mode, press and hold the TOGGLE-STEAM
button on the STEAM GENIE INTERFACE MODULE for 2 seconds until
Antenna
43-20 34th Street
Long Island City, NY 11101 • 1 800 76 STEAM
STEAM GENIE
INTERFACE MODULE
mr.steam®
• The STEAM GENIE INTERFACE MODULE is connected to and mounted near your
steam generator and normally does not require any attention.
• The 4 lights on the STEAM GENIE INTERFACE MODULE indicate the status of the
steam generator that it is connected to. At least one light will be on to show you
that the STEAM GENIE INTERFACE MODULE is operating.
• If the red light is on, the steam cycle is off. If the green light is on, the steam
cycle is on.
• If the red light is blinking there is an error condition in the steam generator. An
error code will be displayed on your eTempo or eTempo/Plus control. Contact the
Mr.Steam Technical Service Department at 800-76-STEAM (East coast) or
800-72-STEAM (West coast) for assistance or additional information.
• The yellow light flashes to indicate when the ON/OFF button on the
STEAM GENIE FOB is pressed.
• The blue light is on to indicate that you are in pairing mode.
• While in pairing mode, the green light will continuously flash the
STEAM GENIE INTERFACE MODULE address (1-8).
• You can turn the generator on and off by pressing either button on the
STEAM GENIE INTERFACE MODULE (while not in pairing mode).
Mounting
Holes
mr.steam
STEAM OFF
STEAM ON
RF ACTIVITY
Toggle Steam
Adjust Address
Press and Hold to
enter pairing mode
Green LED blinks
address in pairing mode
Connection to Steam Toggle Steam
Generator (on the side of
button
the Interface Module)
PAIRING
Address
button
Status LEDs
the blue indicator light comes on. The green indicator light will start
flashing the current address every 4 seconds. Count from 1 to 8 flashes.
To change the STEAM GENIE INTERFACE MODULE address press the ADJUST-ADDRESS button. Observe that the flash increments from 1 to 8
and then back to 1 each time you press it.
• To change the address of the Steam Genie FOB, to match the address of
the STEAM GENIE INTERFACE MODULE, press and hold the ON/OFF
button while the STEAM GENIE INTERFACE MODULE is in pairing
mode. You will see the new flash count on the Steam Genie FOB.
• To exit pairing mode, press the TOGGLE-STEAM button on the STEAM
GENIE INTERFACE MODULE and observe that the blue light turns off.
Pairing mode will automatically exit after 60 seconds.
NOTE: The Steam Genie FOB and STEAM GENIE INTERFACE
MODULE address are maintained even when power is removed.
STEAM GENIE® BATTERY REPLACEMENT:
Your Steam Genie is equipped with a factory installed battery.
A replacement disk battery #CR2032 is available at most local drug stores.
Case
TO REPLACE THE BATTERY:
1. Unscrew the 2 Philips head screws on the Steam Genie FOB case
2. Pry open the hinged case.
3. Carefully lift out the circuit board.
4. Slide out the old battery.
5. Slide in a new battery making sure that the + side
is facing outwards (away from the circuit board).
6. Replace the circuit board in the case. Be sure the button
is facing the right way or else the case will not close.
7. Snap the case closed.
8. Test the remote.
9. Replace the 2 screws.
Circuit Board
NOTE: The Steam Genie FOB will remember its address when the battery is removed.
3
Battery
mr.steam® SteamGenie®
Installation and Operation Instructions
_______________________________________________________________________________________________________________
INSTALLING THE STEAM GENIE® HOLDER
TROUBLESHOOTING
A holder is provided with the Steam Genie™ Control as an
optional convenience.
NOTE: The Steam Genie FOB will not operate the generator
without an eTempo or eTempo/Plus control
Secure the holder to a wall so the Steam Genie™ is oriented
as shown. Determine if the two screws
provided are suitable for the installation conditions. Use alternate hardware or use with plastic anchors as required by
installation conditions. Seal screw holes in the wall against
moisture as required.
(2) Screws
provided
Holder
I cannot control my steam generator with my Steam Genie:
____________________________________________________
Is the light twinkling on the Steam Genie FOB when the button is
pressed?
If not, replace the batteries in the Steam Genie FOB.
If the light still does not twinkle, contact technical service.
_________________________________________________
Are you within range of the STEAM GENIE INTERFACE MODULE?
Go closer to the steam generator and see if that works. If the range
has diminished then the Steam Genie FOB battery may be getting
weak.
For new installations it my be necessary to change the location of the
Steam Genie Interface Module to improve the range. Contact Mr.Steam
technical service for an optional 60 foot cable, PN 103978-60.
_________________________________________________
Go to the Steam Genie Interface Module.
Are any of the Steam Genie Interface Module indicator lights on?
If not check the connection to the steam generator. Unplug and
re-plug the Steam Genie Interface Module from the steam generator.
Verify the steam generator is receiving the correct voltage.
_________________________________________________
Press the TOGGLE STEAM button on the STEAM GENIE INTERFACE
MODULE and verify that it can control the steam generator. If no
lights are on or you cannot manually control the steam generator,
contact technical service.
_________________________________________________
Press the ON/OFF button on the Steam Genie FOB. While the Steam
Genie FOB is twinkling, do you see the yellow RF activity light flashing
on the STEAM GENIE INTERFACE MODULE?
Steam Genie
in holder
LIST OF REPLACEMENT PARTS
If yes, then the address of the Steam Genie FOB and the STEAM GENIE
INTERFACE MODULE may not match. Enter pairing mode by pressing
the TOGGLE STEAM button on the Steam Genie Interface Module until
the blue light comes on. While the blue light on the Steam Genie Interface Module is on, press and hold the ON/OFF button for 2 second
until the LED flashes. Exit pairing mode and test the Steam Genie FOB.
_____________________________________________________
DESCRIPTION
PART NUMBER
_____________________________________________________
Steam Genie FOB
Steam Genie Interface Module
5 foot Interface Cable
60 foot Interface Cable
104058
104059
104060
103978-60
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising