lead acid charger, 10a - Cell-Con
LEAD ACID CHARGER, 10A
Switch mode lead acid
chargers are designed to
effectively charge sealed
lead acid batteries
while protecting the
batteries from overcharging. All charger
ratings are based on
a nominal input of
110-120 VAC/ 50-60Hz.
The output current
ranges from 2.5A to 10A.
Features:
• 3 step charge control with timer
• Switch mode charger
• Available in 12V, 24V, 36V and 48V
versions
• LED status indicator
• Protected against reverse polarity
and short circuit
• Medical approved (EN60601)
• Custom specifications on request
• Waterproof version available
7.25"
2.13"
6.75"
Category
Specification (12V version)
Model number
459740-SB
Input rating
Nominal 110-120VAC/50-60Hz
Nominal voltage rating
12V
Maximum output power
120W
Input surge current limitation
<30A
Switch frequency
63 kHz
Leakage current from battery
2.5 mA (12V battery voltage)
Temperature range
-25ºC to +40ºC
Ripple
<100 mV p-p
Efficiency (at 100% load)
83%
Current limit
yes
Insulation voltage
Primary-ground: 1250VAC, Primary-secondary: 3750VAC, Secondary-ground: 500VAC
Insulation class
Class I
Electrical safety
EN 60601-1, EN 60335-2-29
EMC standards
EN 60601-1-2 (Medical), EN 61000-6-3 (Emission), EN 61000-6-1, EN55014 (Immunity)
Timer
Input connection
Output connection
Dimensions / weight
Recommended battery capacity
*other output connection options available upon request
4hr +/-30 min. (also available with other values)
Grounded US blades
Battery clips*
7.25” x 6.75” x 2.13” (184 x 171 x 54mm)/ 3.3 lbs. (1.5 kg)
40 - 400Ah
Functionality:
Once the charger is attached to a sealed lead acid battery and plugged in, the charging process will begin.
The charger will subject the lead acid battery to three steps of charging.
In the first step, the charger will enter into ‘boost’ mode. During this step, the charger is in constant current
mode with the current rate remaining at its maximum value (note- the battery voltage is lower than
the switching level of the timer).
In step two, the battery will be nominally 80-95% charged, and the charger will switch into time controlled/
constant voltage mode (current is no longer being provided at its maximum rate). The charger will
continue to provide a constant voltage until the time interval is completed.
The third and final step will place the charger in float/standby mode as the battery will be fully charged.
Because the charge voltage is at a standby level, the charger can continue to be connected to the battery.
Should the battery be used, the charger can return to rapid charging (step 1).
Charge control values:
Model number
459740-SB
459740-SC
459740-SD
459740-SE
Charger voltage rating
12V
24V
36V
48V
Step 1: Boost/ constant current
10A
5A
3.3A
2.5A
Step 2: Timer*/ constant voltage
4 hr. +/- 30 min. / 14.7V
4hr. +/- 30 min. / 29.4V
4hr. +/- 30 min. / 44.1V
4hr. +/- 30 min. / 58.8V
13.7V
27.4V
40.8V
54.8V
Step 3: Float/ constant voltage
*Timer is available with other values
LED status indicator:
The lead acid charger has an LED status indicator to inform the user of its status. During step 1, the
LED appears red. In step 2, the LED appears orange. During the third step, the LED appears green.
Charge curve
Charge voltage
Voltage (V)
refer to the
above table
Boost
Current (A)
refer to the
above table
Timer
Indication: RED
Float
ORANGE
GREEN
Charge current
80%
100%
Capacity
*When specifying product, please consult with Cell-Con to verify that the specifications identified on this data sheet are current.
305 Commerce Drive, #300 • Exton, PA 19341 • voice: 610.280.7630 • 800.771.7139 • fax: 610.280.7685 • web: www.cell-con.com
041506