Notifier - Viking Fire Protection
A World of Solutions in
Fire Protection Systems
FireWarden-50C
• Single Data Communications Loop DCLA, DCLB, DCLC
• Loop has 50 addressable device capacity in any combination
of addressable detectors and modules
• Two independently programmable Class A or Class B Notification
Appliance Circuits (NACs)
• Enhanced drift compensation, maintenance alert and auto detector
test features
• New annunciator protocol with connections for up to eight remote
devices, including 80-character LCD annunciators, remote printers,
relays and graphic annunciators
• Built-in Digital Alarm Communicator Transmitter (DACT) with remote
upload/download programming and diagnostic capability (requires
VFWarden-CD)
• Multi-module series: NC-100-6A, NMM-100-10A, NC-100R-6A,
NZM-100-6A
Addressable Devices
i3 Photo Detector
NOT-BG12LX
Addressable
Manual Pull Station
NMM-100A/NMM-100PA
1451A
Ion Detector
NH-100A Series
Thermal Detector
Multi-module Series
NZM-100A
2-Wire Detector
Monitor Module
24 VDC
NI-100A
Ion Detector
NP-100A
Photo Detector
DCL Loop
To Central Station
Over Telephone
Network
NC-100A
Control Module
DNRA Duct Detector
NDM-100A
Dual Monitor Module
EIA-232
ANN BUS
PRN-6 Printer
ANN-80C
FireWarden-50C
Fire Alarm Control Panel
Peripheral Devices
N-ANN-LED
FireWarden-100C
•
•
•
•
•
•
Single Data Communications Loop DCLA, DCLB, DCLC
Supports 198 addressable points (99 detectors/99 modules)
80-character LCD Backlit Display (4 lines x 20 characters)
Four NACs with built-in synchronization
Built-in Digital Alarm Communicator Transmitter (DACT)
Fully programmable from local keypad, local PS-2 keyboard or PC
via VFWarden Windows® Programming Utility
• Enhanced drift compensation, maintenance alert and auto detector
test features
• EIA-485/ANN-BUS interface supports up to 32 ACS Series annunciators
or up to eight ANN-BUS devices
• Multi-module series: NC-100-6A, NMM-100-10A, NC-100R-6A,
NZM-100-6A
Addressable Devices
i3 Photo Detector
NOT-BG12LX
Addressable
Manual Pull Station
NMM-100A/NMM-100PA
1451A
Ion Detector
NH-100A
Thermal Detector
Multi-module Series
NZM-100A
2-Wire Detector
Monitor Module
NI-100A
Ion Detector
DNRA Duct Detector
NP-100A
Photo Detector
24 VDC
DCL Loop
NDM-100A
Dual Monitor Module
EIA-232
To Central Station
NC-100A
Control Module
ANN-BUS or ACS EIA-485 (one or the other)
Terminal Mode EIA-485
FireWarden-100C
Fire Alarm Control Panel
PRN-6 Printer
FDU-80C
ACS Annunciator
Peripheral Devices
NSP-25C Panel
•
•
•
•
•
•
•
•
•
Twenty-five DCL points
Two amp power supply
Two class B NACs
Spartan HFS family of devices
Five zones
Built-in dialer
LEDs for system status; alarm, trouble, supervisory, etc.
Uses Windows Internet Explorer® for programming via laptop Ethernet port
UL/ULC/ETL listed
NSP-25C
Fire Alarm Control Panel
Addressable Devices
NOT-BG12LX
Addressable
Manual Pull Station
HFS-MRA
Relay Module
HFS-TA Thermal Detector
HFS-PTA
Photo/Thermal Detector
HFS-DA
Duct Detector
Peripheral Devices
To Central Station
Over Telephone
Network
DCL Loop
HFS-PA Photo Detector
HFS-MMA
Monitor Module
Conventional Panels
RP-2001C Supression Control Panel Deluge-Preaction
• Designed for sprinkler standards NFPA 13, 15 and 16
• Dual hazard operation
• Adjustable waterflow discharge timer and two soak timers
• Cross-zone (double-interlock) capability
• Six programmable Class B Initiating Device Circuits (IDCs)
• Four programmable Class B output circuits
- (special application power)
• Built in Strobe synchronization
• 7.0 amps total 24 VDC output current
• 80-character LCD display (backlit)
• Disable/Enable control per input zone and output zone
• Built-in Programmer
• FM approved
SFP-5UDC 5-Zone Control Communicator
and SFP-10UDC 10-Zone Control Communicator
• SFP-5UDC has 5 Programmable Class B Initiating
Device Circuits (IDCs)
• SFP-10UDC has 10 programmable Class B Initiating
Device Circuits (IDCs)
• 4 Class B Notification Appliance Circuits (NACs)
• Optional CAC-5X Class A converter module for NAC’s
and IDCs (2 required)
• 7 amps of NAC power
• Programmable NACs
• Built-in strobe synchronization
• Built-in Digital Alarm Communicator/Transmitter,
LCD display and keypad
• Built-in programmer
• 24VDC
• FM approved
RP-2001C
SFP-5UDC
SFP-10UDC
RP-2002C Supression Control Panel Agent Release
• Designed for agent releasing standards
NFPA 12, 12A, 12B, and 2001
• Disable/Enable control per input zone and output zone
• Dual hazard operation
• Adjustable pre-discharge, discharge and waterflow
delay timers
RP-2002C
• Cross-zone (double-interlock) capability
• Six programmable Class B Initiating Device Circuits (IDCs)
• Four programmable Class B output circuits - (special application power)
• Built in Strobe synchronization
• 7.0 amps total 24 VDC output current
• Built-in Programmer
• 80-character LCD display (backlit)
• FM approved
CFP-2401B 1-Zone Control and CFP-2402B 2-Zone Control
• CFP-2401B has 1 Class B Initiating Device Circuit (IDCs)
• CFP-2402B has 2 Class B Initiating Device Circuits (IDCs)
• 1 Class B built-in NAC
• IDCs support normally-open contact
devices and two-wire detector
• 1.25 amps of NAC power
• NAC features 60-second Silence Inhibit, standard
• Alarm and Trouble, Form-C relays standard
• Fuseless, power-limited technology meets
all the latest ULC power-limiting requirements
CFP-2410B 10-Zone Control
• 10 Initiating Device Circuits (IDC)
- All zones accept two-wire smoke detectors
and any normally-open contact devices
- Zones 1 - 8 configured as general alarm zones
- Zones 9 and 10 programmable as smoke zones
or supervisory alarm zones
• 2 built-in, programmable NACs
• 2.5 amps of NAC power, expandable to 5.0 amps
• 3.6 amps of total system power expandable to 6.6 amps
• Alarm, Trouble and Supervisory, Form-C relays standard
CFP-2401B
CFP-2402B
CFP-2410B
ONYX® Series NFS-320C
ONYX NFS-320C
Intelligent Single Loop Fire Alarm Control Panel
• One Data Communications Line (DCLA, DCLB, DCLC) with 318 devices
• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal,
or multisensor) and 159 modules (N.O. manual stations, two-wire smoke,
notification, or relay)
• 6.0 Amp power supply with four Class A/B built-in Notification Appliance Circuits (NACs)
• Fully field programmable with 80-character display (includes QWERTY keypad)
or offline with VeriFireTM Tools Windows-based program utility
• USB Support for VeriFire Tools
• Removable chassis design for easy installation and service
• EIA-485 interface supports up to 32 annunciators
• ONYX Intelligent Sensing advanced set of software algorithms delivers rapid, intelligent
response to incipient fire signatures, while substantially reducing nuisance alarms
• Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks®
up to 200 nodes per NFN
• Listed for releasing
• FM approved
• Available in French
FSP-851A
Photo Detector
FAPT-851A
Acclimate Plus
Detector
FSI-851A
Ion Detector
FSL-751A
VIEWTM Detector
EIA-485
EIA-485 (Terminal)
DNRA Duct Detector
FST-851A
Thermal Detector
ACM-24AT
EIA-232
LCD2-80
PRN-6 Printer
XP Series Multi-module
FSC-851A
IntelliQuadTM Multicriteria Detector
FMM-1A
FMM-1A
Monitor Module
FZM-1A
2-Wire Detector Monitor Module
CO1224A
1451A
Ion Detector
i3 Photo Detector
Gas Detector
ACPS-610
Addressable Charger
Power Supply
RSG
Manual Pull
Station
Intelligent Devices
P2RA
Horn/Strobe
P2RA
Horn/Strobe
P2RA
Horn/Strobe
PF24VA
ExitPointTM
Peripheral Devices
Built for Speed
ONYX® Series NFS2-640
ONYX NFS2-640
Intelligent 1 to 2 Loop Fire Alarm Control Panel
• One Data Communications Line (DCLA, DCLB, DCLC), expandable to two
• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multisensor) and 159 modules
(N.O. manual stations, two-wire smoke, notification, or relay) per DCL
• 318 devices per DCL, 636 devices per panel
• 80-character, 640-character, or displayless options
• ONYX Intelligent Sensing - nine levels of sensitivity, drift compensation and maintenance alert, and auto detector test
• 6.0 Amp power supply with four Class A/B built-in Notification Appliance Circuits (NACs)
• Fully field programmable with 80-character display (includes QWERTY keypad) or offline
with VeriFireTM Tools Windows- based program utility
• Optional Integrated Digital Voice Command with eight channels of high quality digital audio on a single cable
• Unique environment detection includes VIEW® for clean environments, IntelliQuadTM for detection of
all four fire signatures, and Acclimate PlusTM multi sensor that adjusts sensitivity automatically
• Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks up to 200 nodes for NFN
• Listed for releasing
• FM approved
• Available in French
Digital or Analog Audio Loop*
FSP-851A
Photo Detector
FSI-851A
Ion Detector
DNRA Duct Detector
FAPT-851A
Acclimate Plus
Detector
Integrated
Digital Voice
Evacuation
FSL-751A
VIEW Detector
Speaker Circuit
Firefighter Telephone Circuit
Digital Audio Amplifier*
*640 must have an NCA-2 (not shown)
to support Digital Voice Evacuation
EIA-485
FST-851A
Thermal Detector
EIA-485
ACM-24AT
FDU-80C
EIA-232
PRN-6 Printer
XP Series Multi-module
FSC-851A
IntelliQuad Multicriteria Detector
FMM-1A
FMM-1A
Monitor Module
FZM-1A
2-Wire Detector Monitor Module
RSG
Manual Pull
Station
ACPS-610
Addressable Charger
Power Supply
CO1224A
1451A
Ion Detector
i3 Photo Detector
Gas Detector
Intelligent Devices
P2RA
Horn/Strobe
P2RA
Horn/Strobe
P2RA
Horn/Strobe
PF24VA
ExitPoint
Peripheral Devices
Unparalleled Agility
ONYX® Series NFS2-3030
ONYX NFS2-3030 - Intelligent 1 to 10 Loop Fire Alarm Control Panel
• Up to 10 Data Communications Lines (DCLA, DCLB, DCLC)
• Point Capacity: Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multisensor)
and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay) per DCL
• Large 640-character LCD backlit display (16 lines x 40 characters) or displayless (a node on a network)
• Networkable with NOTI•FIRE•NET (NFN), High Speed NOTI•FIRE•NET, and ONYXWorks compatible
up to 200 nodes for NFN
• Application code is saved in Flash memory
• Built-in Degraded Mode option. In the event of a CPU failure, the loop control modules will continue
to monitor fire alarm conditions
• ONYX Intelligent Sensing advanced set of software algorithms delivers rapid, intelligent response
to incipient fire signatures, while substantially reducing nuisance alarms including nine levels
of alarm and pre-alarm, cooperative sensing and self-optimizing pre-alarm
• Optional integrated Digital Voice Command with eight channels of high quality digital audio and five
channels of fire fighter’s telephone, all on a single riser
• EIA-485 annunciators, including custom graphics
• FM6320 approved gas detection system
• Listed for releasing
• FM approved
• Available in French
EIA-485
Audio Risers
Phone Risers
FAPT-851A
Acclimate Plus
Detector
FSP-851A
Photo Detector
EIA-485
LCD2-80*
LCD-160 Display
FSL-751A
VIEW Detector
SCS Smoke Control Station
Custom Graphics
Annunciator
ACM-24AT
EIA-232
FSI-851A
Ion Detector
FST-851A
Thermal Detector
PRN-6 Printer
Speaker Circuit
Digital or Analog Audio Loop
DNRA Duct Detector
Firefighter Telephone Circuit
Digital Audio Amplifier
To XPIQ Transponder
XP Series Multi-module
FSC-851A
IntelliQuad Multicriteria Detector
Speaker Circuit
FMM-1A
CO1224A
Firefighter Telephone Circuit
Digital Audio Amplifier
FMM-1A
Monitor Module
FZM-1A
2-Wire Detector Monitor
Module
RSG
Manual Pull
Station
ACPS-610
Addressable Charger
Power Supply
Intelligent Devices
Peripheral Devices
1451A
Ion Detector
i3 Photo Detector
P2RA
Horn/Strobe
P2RA
Horn/Strobe
P2RA
Horn/Strobe
Integrated
Digital Voice
Evacuation
PF24VA
ExitPoint
FMM-4-20A
Gas Detector
* RDP port can support LCD-160 or LCD2-80 in
Terminal Mode, but not both at the same time
Sheer Power and Performance
Networking and Integration
NOTIFIER Fire Panels
NOTIFIER Fire Panels
Ademco Vista Security
Competitive Fire Interface
FirstVisionTM
Telco Lines
DACR
ONYXWorks® Features
• Supports a client-server technology based on Echelon and a NOTI•FIRE•NET
peer-to-peer network
• Integrates competitive Fire Alarm Control Panel interfaces, security panels
and CCTV applications
• Connects new and existing equipment into a Local Area Network (LAN)
or Wide Area Network (WAN)
• Supports Digital Alarm Communicator Receiver (DACR) interface
for monitoring of remote panels
• Graphic Editing mode allows for onsite programming of floor plan screens,
devices and navigational buttons
• Windows XP Support
CCTV Integration
IP
High Speed NOTI•FIRE•NETTM Features
• Supports ONYX Series (NFS-320C, NFS-640, NFS2-640, NFS-3030, NFS2-3030),
NCA-2 and Digital Voice Command
• Supports BACnet Gateway, NWS and FirstVision Applications
• Increased network protocol communications; 12Mb VDSL for Wire and 100Mb
for Multi-Mode Fiber and Single-Mode Fiber
• Increased node count to 200 nodes including digital audio applications
Network Printer
Echelon
NOTI•FIRE•NETTM Features
• Supports ONYX Series (NFS-320C, NFS-640, NFS2-640, NFS-3030, NFS2-3030)
and Digital Voice Command
• Backward compatible to NOTIFIER classic series of Fire Alarm Control Panels
(AFP-200, AFP-400, AFP-1010 and AM2020)
• Network Control Annunciator (NCA) is used to annunciate network events,
and provide network control
• BACnet Gateway supports industry standard BACnet/IP connectivity
to Building Automation Systems (BAS/BMS)
• NOTI•FIRE•NET Web Server (NWS) provides remote read status
capabilities and instant email and text messaging
• ONYX FirstVision intuitive touch screen display for first responders
• Wire and Multi-Mode Fiber options
DACR
Fire and Security Panels with DACT
ONYXWorks Workstation
NCA-2
NOTIFIER Fire Panels
FirstVisionTM
NWS
Additional Network Literature
• Network & Integrated Product Brochure
• ONYXWorks Integrated Facilities Monitoring System Brochure
Unified Command
and Control
NOTIFIER
10 Whitmore Road, Woodbridge
Ontario L4L 7Z4 Canada
Tel: 1-905-856-8733 Toll Free: 1-888-289-1114
Fax: 1-905-856-9687
For additional offices in Canada, visit www.notifier.com
All NOTIFIER products in this catalogue are ULC listed.
For over 60 years, NOTIFIER has been a leader in the fire alarm industry. Today, we are
the largest manufacturer of engineered fire alarm systems with over 400 distributors
worldwide, and regional support operations on every continent to ensure we provide
the flexibility and options your business needs.
NOTIFIER - Leaders in Life. Safety. Technology.
M-B-PI2-CAN 3/11
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising