12V/24V Low Battery Protection - ibs

12V/24V Low Battery Protection - ibs
Users Manual
Installation
8A Fuse for LBP8 in
Load off
Sense
Reset
In
Out
8A
Appliances:
- 12V energy light
- Fridge
- Radio
- Heating system
- Charger
- Laptop
- Water pump
Features
The new IBS 8A and 16A Low Battery Protection with latest
RISK micro computer technology and solid state MOSFET
switch (no contacts) offers a huge range of features:
—Battery and wire sensing wih RiCT (RiCompensationTech.)
—Battery monitoring with Fuzzy Logic
—Battery status indication, full, medium, empty
—Low battery alarm and RunFlat function (emergencies)
—Forced and automatic battery sensing
—Auto reset with charge
—Shut down levels for Single and Dual Battery Systems
—Computer controlled short circuit protection
—Multiple load possible, dynamic load monitoring
—8A and 16A load range with 30% overload capability
—Surge load disconnection suppression, starts big loads
—Solid state switch, no relay contacts, low consumption
—12V/24V selectable with DIP switch on board
The system is fully automatic and in normal application
no action (Sense/Reset Button) is required.
µC
12/24V
Low Battery Protection
Load off, red LED:
on:
on if load disconnected
Flashing/Beep: - Overload/short circuit (Check load before
pushing reset: 3x Sense button)
LBP8
12V/24V
Low Battery
Protection
Plug receptacle
of cigarette lighter
12V or 24V
30A Fuse
for LBP16
only
12V
Red
Load off
Red
Sense
In
Reset
Out
Black
12/24V
µC
Low Battery Protection
Black
LBP16
12V or 24V
Battery Status, multi-colour LED:
Battery full:
on (green); battery>60%
Battery medium: on (orange); 20%<battery<60%
Battery empty:
on (red); battery<20%, flashing LED
Sense/Reset Button actuation:
3x:
complete system reset, all values lost
(Beeper tones indicate software version)
1x:
starts battery sense routine, see RiCT
1x:
to stop Beep if alarm occurred
Until Beep:
RunFlat function if UB<12.6V, Beep
reminder every 30 Sec
IBS-D
µC
5
attery
ans
Jahre
year
War
rant y
stem
Dynamic Battery Sensing
B
al
Open 4 screews in front panel
Beside square Chip is the DIP Switch
Change setting with a thin pin:
Default setting DIP1-3: Off
Sy
RiCT
u
RiCT Sensing:
DIP1: Off=12V, On=24V
DIP2: Off=Buzzer on, On=Buzzer off
DIP3: Off=Single battery SBS, On=Dual battery DBS
DIP4: never change this default setting!
- Automatic with preset value, dynamic
tuning over time
- Forced by pressing sense once,
achieves accurate value right from start.
Prior activation load has to be switched
on! After Load has been switched off, load
is switched on again after latest 2 Min,
process finishes latest after 12 Min.
Do not connect GND wire (black) on Load side to
vehicle/chassis GND. Always wire red and black on Load side
directly to power outlets.
Seestrasse 24
3600 Thun / Switzerland
Ph./Fax: +41 (0)33 221 06 16/17
www.ibs-tech.ch
www,ibs-dual-battery.ch
www.ibs-inverters.ch
Distributor:
LBP8_16_e_4.5 / 1.4.2011/SW4.5
MADE IN SWITZERLAND
RMS (Rugged Mounting System) for LBP16
LBP16 is equipped with a slide lock mounting system (RMS).
Action below shows how to mount and release the unit.
LBP8 is not equipped with a mounting system.
Load off
Sense
In
Reset
Out
12/24V
µC
Low Battery Protection
Mount unit
Release unit
RoHS OK