CMS Series Carbon Monoxide Alarms - abrasive

CMS Series Carbon Monoxide Alarms - abrasive
Description
T ECHNICAL D ATA S HEET
Carbon monoxide monitor and alarm
for breathing air supplied from a
compressed air source. Features warning
lights, high-decibel audible alarm,
particulate/oil filter, and connections for
optional remote alarm and shutdown
devices.
Note: For safe, efficient blasting, read
and follow the owner's manual and seek
training for everyone who will use this
equipment.
CMS Series
Carbon Monoxide
Alarms
Model CMS-1 Wall-Mountable,
with Calibration Kit:
Stock No. 23017
Model CMS-2 Field-Portable,
with Calibration Kit:
Stock No. 22894
Purpose
The CMS monitor detects carbon
monoxide and hydrocarbons in a
compressed air supply and triggers visual
and audible alarms when CO is detected
in concentrations of 10 parts per million.
CMS-1 is wall-mountable; CMS-2 is
field-portable with integral rugged
carrying case.
Model CMS-2 Field-Portable
NOTE: CMS monitors do not remove
CO or convert CO to CO2
Requirements for Operation
• Compressed-air source (55 to 145 psi)
of Grade D breathing air as defined by
the Compressed Gas Association
commodity specification: G-7.1
(www.cganet.com).
• Air flow of 0.5 to 0.8 scfh at 55 psi or
more to operate and maintain adequate
sampling
• Power – 120 volt AC or 12 volt DC.
Line cord provided for 120 volt AC;
may be conduit wired.
Description of Operation
Connect the CMS to the air supply and
to an electric power source. The system
warms up and stabilizes in about five
minutes.
Once stabilized, the unit is operational
and continuously monitors the incoming
air. The indicator light glows green to
indicate adequate air pressure and flow,
and that the CO concentration is below 10
ppm. The alarm light glows yellow, and a
loud, intermittent alarms sounds if air
flow or pressure drops.
The air-quality light turns red and the
CMS sounds a loud, constant alarm if CO
reaches 10 ppm. To prevent CO
poisoning, the operators must immediately
remove their respirators and exit the blast
environment.
Model CMS-1 Wall-Mountable
CMS Remote Alarm
Once the source of CO has been
located, and corrected, the CMS will
continue to monitor the air and will glow
green automatically when the CO has
passed out of the air supply.
Advantages
• One monitor can serve multiple
respirators
• Microprocessor circuit and digital
readout provide accurate readings
• Simple, rugged construction for inplant or field use
• Manual calibration accomplished in
minutes
• Long-lasting replaceable sensor
• May be used with 120 volt AC or 12
volt DC power source
• Accommodates optional remote alarm
kit
Specifications
• Shielded to reject radio frequency
interference
• Includes 10 feet of 1/8-inch tubing
and connector fittings
• Electrochemical sensor responds
instantly to CO
• CMS-1 has polycarbonate case with
impact-resistant clear plastic cover
meets NEMA-4 specifications
• CMS-2 has polyethylene case with
dual hinges, dual latches, and dusttight, weather-resistant rubber seal
• Nominal noise rating of 98 dB at
distance of one foot for the standard
alarm; and 100 dB at distance of 3.1
feet for the optional remote alarm.
Options and Accessories
Humidifier ................ Stock No. 03600
Approvals and Certifications
Remote alarm kit includes: remote
alarm, stand, wiring connector,
and 50-ft. cord .......... Stock No. 22909
• Meets OSHA requirement for CO
monitoring
Remote alarm extension
cord .......................... Stock No. 22910
Item
Related Clemco Literature
Description
Replacement Parts
Item
Description
(-)
CMS-1 CO monitor package, includes:
monitor, calibration connector, and
10 PPM test gas ..................................................... 23017
CMS-1 CO monitor includes:
monitor & items 3 to 9 .......................................... 23012
Calibration connector assembly ........................... 23011
Test gas10 PPM .................................................... 22865
Test gas, impurity free .......................................... 11132
Regulator /Filter .................................................... 23013
Flowmeter ............................................................. 21376
Horn w/ wire, 12 Volt DC .................................... 22922
Adaptor, straight, 1/8” NPT x 1/8” barb .............. 11732
Adaptor, elbow, 1/8” NPT x 1/8” barb ................. 11733
Tubing, urethane, per foot .................................... 12475
Reducer, 1/4” x 1/8” ............................................. 02026
Sensor (not shown) ............................................... 23015
Filter element (not shown) .................................... 23014
2.
3.
4.
5.
6.
7.
8.
9.
10.
(-)
(-)
Stock No.
calibration connector, & 10 PPM test gas. Available
120 V AC &12 V DC; specify voltage ....................... 22894
CMS-2 CO monitor (instrument only) ....................... 22892
Calibration connector assembly .................................. 22893
Test gas10 PPM .......................................................... 22865
Test gas, impurity free ................................................ 11132
Flowmeter ................................................................... 21376
Horn w/ wire, 12 Volt DC .......................................... 22922
Alarm light, exterior w/ wire ..................................... 22923
Fitting, 1/4" OD, quick fit ............................................ 22924
Tubing, urethane, per foot ........................................... 12475
Sensor (not shown) ..................................................... 22919
Regulator/filter (not shown) ....................................... 22920
Filter element (not shown) .......................................... 22921
Air-line humidifier ..................................................... 03600
1.
2.
3.
4.
5.
6.
7.
8.
(-)
(-)
(-)
(-)
Optional
(-) Remote Alarm: includes: alarm, stand, wiring
connector and 50 ft. cord ............................................ 22909
1. Cable, remote alarm extension 50 feet ....................... 22910
2. Strobe light .................................................................. 22984
3. Horn ............................................................................. 22985
4. Wiring adaptor ............................................................ 22986
5. Stand assembly with internal wiring .......................... 22987
(7)
(6)
Stock No.
Stock No. (-) CMS-2 CO monitor package, includes: monitor,
Operator Safety Equipment ................................................. 07764
CMS-1 Owners Manual ...................................................... 23301
CMS-2 Owners Manual ...................................................... 22925
1.
Description
(1)
(7)
(1)
(9)
(6)
(5)
(2)
(10)
(8)
(2)
(8)
(3)
CMS-2
Portable
Contractor
Model
(3)
(4)
(5)
(4)
CMS-1
Wall Mountable
Industrial Model
(5)
(2)
(3)
(4)
Packaging:
Ships in one carton with owner’s manual.
Stock No.
Dimensions
23017
23012
22894
22892
7 1/2” H x 7 1/2” W x 5 1/2” D
7 1/2” H x 7 1/2” W x 5 1/2” D
9 1/4” H x 10 3/8” W x 5” D
9 1/4” H x 10 3/8” W x 5” D
Shipping Wt.
8 lb
6 lb
9 lb
7 lb
Authorized Distributor:
(1)
Color:
Remote
Alarm
CMS-2: black case w/ white graphic front
CMS-1: gray metal enclosure w/ white graphic front
Optional Remote Alarm: gray metal
ISO 9001-2000 certified. Clemco is committed to continuous product improvement. Specifications are subject to change without notice.
© 2004 Clemco Industries Corp. • One Cable Car Drive • Washington, MO 63090 • Phone (636) 239-4300 • Fax (800) 726-7559
www.clemcoindustries.com
Stock No. 23248
Job No. 1195-0901, Rev.B, 08/04
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising