Non-Halogen, Flame-Retardant, Flexible, Cross-Linked Polyethylene Insulated Electric Wire EM-LMFC EM-LMFC -An environmentally friendly electric wire that streamlines wiring on boards, etc. Environmental performance Streamlined wiring RoHS compliant Non-halogen Flame-retardant Unified wiring material and reduced size Lower cost It allows IV wires to be smaller! Although the EM-LMFC is an eco wire, it is as flexible as a conventional wire. What is more, its price is identical to that of the previous LMFC. A highly acclaimed electric wire, the EM-LMFC is now widely used for railway vehicles and various electric devices, as well as for wiring on boards. In addition, the EM-LMFC offers superior heat resistance. This means that its allowable current is higher than that of IV and KIV, permitting smaller electric wires. It therefore enables cost reductions, and contributes to boards with a lighter weight and smaller dimensions. 1. Space-saving The EM-LMFC comes in a smaller size, enabling space to be saved. IV wire 8mm2 EM-LMFC 3.5mm2 (use of 7 wires with an external diameter of 6.0mm each) (use of 7 wires with an external diameter of 4.6mm each) Comparison of allowable currents Allowable current (ambient temperature: 40°C) For the allowable currents of the EM-LMFC, values that apply to a Conductor maximum conductor temperature of 110°C were adopted and converted size into values that apply to an ambient temperature of 40°C. EM-LMFC (A) EM IE/F (A) IV (A) 2 3.5 5.5 8 14 22 38 60 100 150 200 250 325 41 56 75 93 134 175 247 331 455 604 717 850 994 29 39 51 65 94 123 173 232 319 424 503 596 697 22 30 40 49 71 93 132 177 243 322 382 453 530 3. Heat resistance With the conduction of a current at 60A, the EM-LMFC does not suffer from deformation or fusion, and does not cause the insulation lock to dig into the wires. Smaller size The insulation lock is digging into the wires. The insulation lock is not digging in. IV wire 8mm2 Conduction of current at 60A EM-LMFC 5.5mm2 Conduction of current at 60A 2. Flexible The EM-LMFC does not suffer from the reduction in flexibility typically caused by the use of environmentally friendly materials. This means that it permits easy wiring. 160 mm 310mm EM IE/F EM-LMFC Load: 100g Comparison of deflection narrow n i n e v e dense. s easy, i e r g a n i s r i e r i W w hen the w r o s space Applications Wiring on boards/Lead wires of electric devices Distribution boards, motors, power generators, welding machines, transformers Separator Railway vehicles (black only) Vehicles for conventional railways, subways, and industrial railways Non-halogen, flameretardant, flexible, crosslinked polyethylene insulator Tinned annealed copper stranded wires High-voltage distribution Features Halogen gas is not generated during its combustion. RoHS RoHS substances are not used. Railway Rollingstock & Machinery Association. Superior varnish resistance. Upper temperature limit: 110°C (registered as the upper temperature limit for insulating material used with an electrical appliance). Flame retardancy The EM-LMFC meets the criteria of “flame retardancy” in accordance with the railway vehicle material combustion test undertaken by the Japan *Proven in our own test. It is highly flexible and has little odor. It complies with the standards and specifications of WL, HF-WL, LMFC, and EM-LMFC. Six different colors are available in each size, ensuring ease of use. Labeling example FURUKAWA 600V HF-WL1 <PS> E FEIC TAINEN Year of Manufacture EcoAce 600V EM-LMFC 2mm2 The “HF-WL1” symbol for railway vehicles is available in black only. Wiring in dense wires Table of allowable currents 600V/6600V EM-LMFC Conductor temperature (°C) 110°C 105°C 90°C Cross-section Rated temperature Reference temperature Reference temperature area of the conductor (mm2) 0.75 22 22 19 1.25 29 28 24 2 41 39 35 3.5 56 54 48 5.5 75 72 63 8 93 90 79 14 134 129 113 22 175 169 148 (30) 212 204 179 38 247 238 209 (50) 290 279 245 60 331 319 280 (80) 392 378 332 100 455 438 384 (125) 525 506 444 150 604 581 510 200 717 690 605 250 850 818 718 325 994 957 839 Note: Values in ( ) indicate quasi-standard sizes. Wiring in a railway vehicle Wiring of lead wires Wiring on a board Table of structural dimensions 600V EM-LMFC Conductor CrossApproximate Structure section area Number of wires/ external (mm2) Wire diameter (mm) diameter (mm) 0.75 30/0.18 1.1 1.25 50/0.18 1.5 Insulation thickness (mm) Approximate Maximum Minimum finished conductor Test voltage insulation external resistance (at (V/minute) resistance diameter (mm) 20°C) (Ω/km) (MΩkm) Surface leakage resistance (MΩ) Approximate mass (kg/km) 1.0 3.2 25.8 2,200 80 300 16 1.0 3.6 15.5 2,200 70 300 22 2 37/0.26 1.8 1.0 3.9 9.91 2,200 60 300 30 3.5 45/0.32 2.5 1.0 4.6 5.38 2,200 50 300 48 5.5 35/0.45 3.1 1.0 5.2 3.50 2,200 50 200 68 8 50/0.45 3.7 1.0 5.8 2.45 2,200 50 200 92 14 88/0.45 4.9 1.0 7.0 1.39 2,200 40 200 155 22 7/20/0.45 6.7 1.2 9.6 0.892 2,200 40 100 255 (30) 7/27/0.45 7.8 1.2 10.7 0.661 2,200 40 100 335 38 7/34/0.45 8.7 1.2 11.7 0.525 2,200 40 100 410 (50) 19/16/0.45 10.0 1.5 13.6 0.411 2,500 30 100 530 60 19/20/0.45 11.2 1.5 14.8 0.329 2,500 30 100 650 (80) 19/27/0.45 13.0 1.5 16.7 0.243 2,500 30 90 860 100 19/34/0.45 14.6 2.0 19.4 0.193 3,000 30 80 1,110 (125) 19/42/0.45 16.3 2.0 20.5 0.156 3,000 20 70 1,350 150 27/34/0.45 18.0 2.0 22.2 0.136 3,000 20 60 1,540 200 37/34/0.45 20.4 2.5 25.6 0.0993 3,000 20 60 2,120 250 37/42/0.45 22.7 2.5 27.9 0.0803 3,000 15 50 2,580 325 37/55/0.45 26.0 2.5 31.1 0.0614 3,000 15 50 3,360 Surface leakage resistance (MΩ) Approximate mass (kg/km) Note: Values in ( ) indicate quasi-standard sizes. 6600V EM-LMFC Conductor CrossApproximate Structure section area Number of wires/ external (mm2) Wire diameter (mm) diameter (mm) 3.5 45/0.32 2.5 5.5 35/0.45 3.1 Insulation thickness (mm) Approximate Maximum Minimum finished conductor Test voltage insulation external resistance (at (V/minute) resistance diameter (mm) 20°C) (Ω/km) (MΩkm) 4.0 10.5 5.38 18,000 110 100 140 4.0 11.1 3.50 18,000 100 100 170 8 50/0.45 3.7 4.0 11.7 2.45 18,000 90 100 200 14 88/0.45 4.9 4.0 12.9 1.39 18,000 75 100 275 22 7/20/0.45 6.7 4.0 14.7 0.892 18,000 60 100 385 (30) 7/27/0.45 7.8 4.0 15.8 0.661 18,000 55 90 480 38 7/34/0.45 8.7 4.0 16.7 0.525 18,000 50 90 565 (50) 19/16/0.45 10.0 4.0 18.0 0.411 18,000 45 80 685 60 19/20/0.45 11.2 4.0 19.2 0.329 18,000 40 70 815 (80) 100 (125) 150 19/27/0.45 19/34/0.45 19/42/0.45 27/34/0.45 13.0 14.6 16.3 18.0 4.0 4.0 4.0 4.0 21.0 22.6 24.3 26.0 0.243 0.193 0.156 0.136 18,000 18,000 18,000 18,000 35 35 30 30 60 60 60 50 1,050 1,270 1,520 1,740 Note: Values in ( ) indicate quasi-standard sizes. http://www.feic.co.jp/ HEADQUARTERS: 6-48-10 Higashi-Nippori, Arakawa-ku, Tokyo, 116-0014 Japan Tel: +81-3-3803-1151 Fax: +81-3-3801-0581 For technical enquiries, please contact: HIRATSUKA WORKS: 5-1-9 Higashi-Yawata, Hiratsuka, Kanagawa Pref., 254-0016 Japan Tel: +81-463-21-8290 Fax: +81-463-21-8292 ● For more information, please contact: Furukawa Electric Group strives to develop environmentally considerate products. eFriendly Logo Mark This logo mark indicates that the products and services satisfy the standards Products listed in this catalog are subject to change without prior notice for improvement of appearance and/or specifications. of environmentally friendly products of the Furukawa Electric Group. DE-056 2D6 TR 200
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertising