EBARA JITSUGYO OZSD-3000A Ozone Generator Instruction manual

EBARA JITSUGYO OZSD-3000A Ozone Generator Instruction manual

Below you will find brief information for Ozone Generator OZSD-3000A. This manual provides detailed guidance on the installation, operation, and maintenance of the OZSD-3000A Ozone Generator. It covers topics such as unpacking and checking the generator, requirements for installation, pipings, operation procedures both manual and automatic, and safety precautions.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Ozone Generator OZSD-3000A Instruction Manual | Manualzz

MODEL OZSD-3000A

OZONE GENERATOR

INSTRUCTION MANUAL

Published on July 28, 2011

EOP-P62-100-7-001-01E/a

EBARA JITSUGYO CO., LTD.

MEASURING INSTRUMENT

AND MEDICAL DIVISION

MEASURING INSTRUMENT SALES DEPARTMENT

EAST JAPAN SALES BRANCH

WEST JAPAN SALES BRANCH

: 3-12, Kurigi 2-Chome, Asao-ku,

Kawasaki-shi, Kanagawa, 215-0033 Japan

Tel. +81-44-981-0560 Fax. +81-44-981-0561

E-mail [email protected]

: 2-13, Hiranocho 3-Chome, Chuo-ku,

Osaka-shi, Osaka, 541-0046 Japan

Tel. +81-6-6231-3528 Fax. +81-6-6231-2929

E-mail [email protected]

TECHNICAL ENGINEERING DEPARTMENT

3-12, Kurigi 2-Chome, Asao-ku,

Kawasaki-shi, Kanagawa, 215-0033 Japan

Tel. +81-44-981-0560 Fax. +81-44-981-0561

E-mail [email protected]

E.J.OZONE PRODUCTS

EOP-P62-100-7-001-01E/a

SAFETY MESSAGE:

Please read this instruction manual before working with the products.

For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining the product.

Especially the following safety messages and marks are the most important information for human bodies.

Please ensure the safety of all users for our products by reviewing this information.

Important Safety Message

The following safety massages and marks are dangerous items in case of handling the monitor.

Please ensure the safety of all users for our products by reviewing this information.

Mark Description

DANGER Call your attention to serious dangerous items.

WARNING Call your attention to middle dangerous items.

CAUTION Call your attention to slight dangerous items.

Dangerous Characteristics for Ozone Treatment

Warning

Ozone gas is an injurious material and it may sometimes cause in death when directly breathed it.

And also it affects to accelerate the burning material explosively.

Requirements for precautions to use Ozone generator safety are described in this instruction manual, but in this section, it is shown to treat Ozone gas as important safety messages.

E.J.OZONE PRODUCTS

- 1 -

EOP-P62-100-7-001-01E/a

WARNING

1. Prohibition to exhaust ozone gas in atmosphere.

Do not discharge ozone gas in the room, and also do check and maintain loosened points, deteriorations and damage for piping as they do not make it to have a leakage.

When discharged it, dissolve and exhaust the ozone gas using deozonizer or commercial base catalyst.

2. Ventilation equipment

Ventilate room air sufficiently, as it dose not cause in serious injury when ozone gas is leaked.

3. Installation for ozone gas defector or gas alarm

We recommend you to install ozone gas detector or gas alarm, because the gas is dangerous.

4. Prohibition for using fire

Do complete to prohibit works with a fire in the room on which ozone generator is installed.

When work using a fire such as welding is happened, do not use this generator.

5. Shelter

When smelled the ozone gas, based on the leakage, take shelter outside of the room as soon as possible after the power is turned OFF.

6. Administrator

Decide an a administrator for controlling the ozone gas, and make him to manage the room i n order to avoid the mistreatment and a dangerous accident.

INTRODUCTION:

Thank you for purchasing the ozone generator Model OZSD-3000A called as "LABO OZONIZER."

We, Ebara Jitsugyo Co., LTD. is producing and selling the ozone generator giving attention to it, as the performance can be full used.

However, if you have only a mistake for the treatment, the generator will not give a plenty of the performance, but also it may sometimes cause in trouble.

This instruction manual provides the latest information in order to install and to use correctly and safety, so that their important messages are described in this manual.

CAUTION

Read this instruction manual before you begin working with product.

Do not operate this generator when used a fire, such as welding work.

When required more information on the operation or detailed technical information regarding this instruction, please consult us them.

Ebara Jitsugyo Co., Ltd. has two assistance number's

Tell : +81-44-981-0560

Fax : +81-44-981-0561

E.J.OZONE PRODUCTS

- 2 -

EOP-P62-100-7-001-01E/a

List of Contents

1. Unpacking and checking the ozone generator

・・・・・・・・・・ 4

2. Outline of the generator ・ ・・・・・・・・・・・・・・・・・

4

2.1 Characteristics ・・・・・・・・・・・・・・・・・・・・・

4

2.2 Specifications ・・・・・・・・・・・・・・・・・・・・・・

4

2.3 Outline and function parts

・・・・・・・・・・・・・・・・

5

3. Installation

・・・・・・・・・・・・・・・・・・・・・・・・ 6

3.1 Requirements for installation

・・・・・・・・・・・・・・・

6

3.2 Pipings

・・・・・・・・・・・・・・・・・・・・・・・・

7

3.3 Specification of ozone gas line

・・・・・・・・・・・・・・・

7

3.4 Accessory parts for pipings ・・・・・・・・・・・・・・・・

7

3.5 How to connect the piping joints

・・・・・・・・・・・・・・ 8

4. Operation

・・・・・・・・・・・・・・・・・・・・・・・・

10

4.1 Procedure for manual operation ・・・・・・・・・・・・・・

10

4.2 Procedure for automatic operation

・・・・・・・・・・・・・

10

4.3 Stopping operation of the monitor

・・・・・・・・・・・・・

10

5. Inspection and maintenance

・・・・・・・・・・・・・・・・・ 11

6. Warranty ・・・・・・・・・・・・・・・・・・・・・・・・・ 11

List of Illustrations and Table

Figure - 1 The front panel and the rear panel

・・・・・・・・・・

5

Figure - 2 Flow diagram for the ozone generator

・・・・・・・・・ 6

Figure - 3 Controlling ozone concentration in constant

・・・・・・

10

Table - 1 Piping specifications

・・・・・・・・・・・・・・・・ 7

Table - 2 Accessory parts for pipings

・・・・・・・・・・・・・

8

Table - 3 Abnormal phenomena and the countermeasures

・・・・

11

E.J.OZONE PRODUCTS

- 3 -

EOP-P62-100-7-001-01E/a

1. Unpacking and checking the ozone generator

(1) Unpack and check the ozone generator whether it has a damage or not under shipping.

(2) Check the generator whether it is the same one of which you specified or not, when you ordering.

(3) Confirm that screws and bolts installed on this generator are not loose.

2. Outline of the generator

2.1 Characteristics

This ozone generator is designed for the purpose of generating a small amount of ozone and it has some characteristics as follows.

It is possible to adjust extensively ozone generation in the range, because pulse counting system is adopted

to control the power for ozone generator.

It is possible to control ozone concentration by using external signal. (4 ~ 20 mA).

Ozone concentration in steady state is obtained from this generator, because the generator unit is controlled

with constant temperature.

2.2 Specifications

(1) Performances

Model

Control method

Material gas

Ozone generation

Concentration

Air to ozonize

Power supply

Power consumption

Dimensions

Weight

OZSD-3000A silent discharge dry air which has dew-drop at temperature lower than -40

(oxygen is suitable)

3.0

g/h

10.0 g/m3

5 L/min

100 V AC, 50/60 Hz

200 W

480 W

×360 D×199 H mm

approx. 18.5 kg

(2) Environment conditions

The environment conditions for this generator are as follows, and it must be used in accordance with this condition.

1) This equipment is only used indoors. Do not use it outdoors.

2) Temperature 5~35

3) Relative humidity less than 80 % RH

E.J.OZONE PRODUCTS

- 4 -

EOP-P62-100-7-001-01E/a

2.3 Outline and function parts

Refer to the following illustrations of the front panel and the rear panel.

Figure - 1 The front panel and the rear panel

Front panel

Flow meter

LABO OZONIZER

CONTROL. ADJ

FLOW

Output adjusting

trimmer

Rear panel

Pilot lamp

Power switch

AUTO

MANUAL

P.L

POWER

OUT

Auto/Manual switch

Joints

IN

Terminal

block

AC-100V FUSE

Fuse holder

Socket for power cable

Power switch

Pilot lamp

Auto / Manual switch

Manual

: This is used when electric power turned on and off.

: This lamp will light up when power switched on.

: It is possible to change the operation to Auto mode or to Manual mode

: It is able to adjust ozone concentration, turning output adjusting trimmer.

: This mode controls ozone concentration with external control signal Auto of 4~20 mA.

Output adjusting trimmer : This trimmer is used to adjust ozone concentration produced from

(CONTROL ADJ)

Flow meter

Joints

the generator.

: It is used to adjust flow rate of ozone gas.

: In ・・・・・ inlet for material gas

Fuse / holder

Socket for power cable

Terminal block

Out ・・・ outlet for ozone gas

: 100V, 3A /

φ6×20 mm

: This is used to connect the power cable.

: These terminals are used to connect external control signal of

4 ~ 20 mA as follows.

(1) ・・・・・・・・・・・≈ Polarity

(2) ・・・・・・・・・・・¬ Polarity

E.J.OZONE PRODUCTS

- 5 -

inlet for material gas supply pressure

0~0.MPa

Figure - 2 Flow diagram for the ozone generator

EOP-P62-100-7-001-01E/a flow meter outlet for ozone gas electric poles of ozone generator

3. Installation

3.1 Requirements for installation

The ozone gas generator must be installed on the position which is even level with ground, and the material gas should be kept in dry condition excepting the following precaution.

In order to use the generator in steady stale, and to protect in from any damage, proper considerations for installation, piping for material gas, power supply and etc., are required to refer to well the following paragraphs (1) through (5).

(1) Prohibition places for installation.

Install the generator on the places excepting the followings in order to avoid damage and failure and also to keep safety operation.

As this generator is designed as one of indoor type enclosure, it is not used where exposed to the water.

Dusty place and environments where such corrosive gas as hydrogen nitride gas, sulfurous gas, or halogen

gas is flowing around the generator.

Environments where is in high temperature and high humidity, and place of radical temperature changes.

Places where strong vibration may be happed, or place of which is receiving continuos vibration.

Place under direct sun shine.

Places under or near strong magnetic field and electric field, and close to high frequency source.

Places which have not sufficient spaces to maintain and / or inspect the generator.

Process plant where explosive gas may be made up in the environment.

DANGER

Explosion could result in death or serious injury.

Do not use the ozone generator in explosive environments.

Do not apply sampling gas or water with over pressure than 98kPa to the

generator.

It may have a chance to make the generator to be broken or to have a burst the encloser or the parts, and also this may cause ozone leakage.

Notice: This product is a precision instrument, so it should be free from shock or vibration.

E.J.OZONE PRODUCTS

- 6 -

EOP-P62-100-7-001-01E/a

(2) Power supply

When supplying the power source to the generator, use the power source recommended to instrumentation.

If an inductive load and / or a large capacities load are connected to the power line, it can sometimes cause a surge problem for disturbing the measurement.

(3) Wiring for external control input signal

It is acceptable that a shielded wire is not always used for this signal wiring, but at last, twist pair wire should be usually used for this wiring.

However, do not use these twisted wires without shielding with power cable in conduit or open tray, and also avoid to wire it near heavy electric machine.

CAUTION

In order to avoid dangerous and to protect the generator, install a no-fuse breaker at power line

outdoors.

3.2 Piping

s

In this section, requirements for pipings are described.

To prevent an ozone leakage, is required to do carefully the pipings for its gas line, and take care full the following items.

WARNING

As ozone is poisonous to human bodies, install the pipings as it may not have a leakage.

If water or liquid will flow backward, the generator may be failed in discharge unit, and it is

dangerous.

3.3 Specifications of ozone gas line

Regarding above specification, refer to Table - 1 below.

CAUTION

Use ozone resistant materials surely regarding pipings for ozone gas line.

Usage tubes, joints pickings, reaction vessel

Pipes, joints, reaction vessel

Table - 1 Piping Specifications

Recommended Materials Pressure limit (absolute)

Teflon

490.3 kPa

(5 kgf / cm2) stainless steel

(SUS 304, SUS 316)

3.4 Accessory parts for pipings

The pillowing parts is attached to this device, as it is materials of the pipings.

E.J.OZONE PRODUCTS

- 7 -

Table -2 Accessory parts for pipings

Usage

Pipings of inlet and outlet for ozone gas

Parts

Straight joints for tubes

Teflon tube

φ× 6

Quantities

2 PC

5m

EOP-P62-100-7-001-01E/a

3.5 How to connect the piping joints

(1) Stainless joint

Perform to connect a joint, referring the following sketches

Names of each part

PTFE tube Cap nut rear ferrule insert body front ferrule

Arrange parts as a cap nut (LR), a rear ferrule, a front ferrule and a insert in due order.

Insert PTFE tube till inner end of body, and connect the cap screw to body, after the parts are moved

toward body.

Drive the cap nut by fingers till it is not moved.

Tighting method

When tighting the cap nut finally, tighten it more 3/4 turn from position by fingers, using spanner.

E.J.OZONE PRODUCTS

- 8 -

EOP-P62-100-7-001-01E/a

(2) Teflon (PTFE) joint

Perform to connect a joint in accordance with the procedure with reference of the following sketches.

Names of each part

Insert tube into body and nut cap nut by fingers.

Tighten the cap nut more 1/4 turn from position which is driven by fingers.

After tightening the cap nut, pull the tube slightly and confirm whether it is surely fixed without

looseness.

cap nut tube

(a)

(b)

(c)

CAUTION

After connecting the joint, it must be checked for a leakage.

E.J.OZONE PRODUCTS

- 9 -

EOP-P62-100-7-001-01E/a

4. Operation

4.1 Procedure for manual operation

Operate the generator in accordance with the following procedure.

(1) Connect power plug cap to the socket for 100 V AC.

(2) Supply material gas into the generator and adjust flow rate to the specified one.

(3) Set Auto / Manual switch at "MANUAL."

(4) Rotate output adjusting trimmer (CONTROL ADJ.) to end of left side, and turn on the power switch.

(5) Adjust ozone concentration, using the trimmer. Regarding the position and ozone generation, refer to the performance curve on the ozonizer (ozonizer).

Note : The performance curve is only in reference of the concentration, it is affected by conditions for

Temperature Humidity and Material gas, and also is much changed itself.

4.2 Procedure for automatic operation

This automatic operation mode is used for performing the local operation of the ozone concentration or for controlling it to constant value, using the controller.

(1) Make wirings between controller output (4~20 mA) terminals and the input terminals on rear panel of the generator.

(2) Connect analog output (0~5V) of ozone monitor and the input of controller with cable.

(3) Set auto / manual switch at MANUAL position and turn output trimmer to zero.

(4) Adjust concentrations to required value, using ozone monitor and the controller.

(5) Supply material gas at flow rate of 5L/min, using attached air drier.

(6) Reset Auto / Manual switch at AUTO position and turn on the power.

This will make the generator to begin controlling the ozone concentration.

material air

Figure - 3 Controlling ozone concentration in constant

ozone gas ozone generator tester off gas treatment

4 ~ 20 mA DC controller ozone monitor

4.3 Stopping operation of the generator

(1) Under when manual operation, turn Output adjusting trimmer to zero position, and switch off the power.

(2) When automatic operation, Auto / Manual switch should be set at MANUAL position, and switch off the power.

Note : After when used the ozone generator, purge full an ozone gas in it (about 5 minutes) and have the custody of it.

After above performing, the ozone generator will soon stop its operation.

E.J.OZONE PRODUCTS

- 10 -

EOP-P62-100-7-001-01E/a

5. Inspection and maintenance

In order to use this device for long time without trouble, inspect and maintain the followings.

(1) Routine inspection

Do not small ozone.

Check the generator whether it has an abnormal sound and/or a vibration, or not.

Check and confirm that the earth terminal is connected to the ground surely.

Needs to check air flow rate and the pressure.

(2) Inspection every month

Check a loose points and a defected points on the pipings

(3) Countermeasure of the generator when has the failure, please consult us.

WARNING

As high voltage of 1000V is used for circuit inside of this generator.

Disconnect power cable from the plug socket when inspect inside of it.

Table -3 Abnormal phenomena and the countermeasure

Phenomena Countermeasure

Abnormal sound When this generator has an abnormal sound, stop the work as soon possible.

Abnormal vibration If the generator begins to vibrate itself, stop the work as soon as possible.

Ozone smell

(an offensive)

(1) By turning off no-fuse breaker outside, stop working the generator soon.

(2) Confirm there is not a fire, and open the windows in order to ventilate it.

6. Warranty

WARRANTY: We warrant the ozone generator as follows.

(1) Warranty period

12 months after customers acceptance inspection.

(2) Condition

The ozone generator should be operated under the specified condition described in this instruction

manual.

(3) Limitation of warranty

Liability and obligations are limited to the supply of parts for replacements.

E.J.OZONE PRODUCTS

- 11 -

MEMO

EOP-P62-100-7-001-01E/a

E.J.OZONE PRODUCTS

- 12 -

荏 原 実 業 株 式 会 社

計測器・医療本部

計測器営業部

■東日本営業課:〒215-0033

神奈川県川崎市麻生区栗木2丁目3番12号

TEL 044-981-0560 FAX 044-981-0561

E-mail ej-ozone@ejk.co.jp

■西日本営業課:〒541-0046

大阪市中央区平野町3丁目2番13号

平野町中央ビル5階

TEL 06-6231-3528 FAX 06-6231-2929

E-mail ozon-osaka@ejk.co.jp

技 術 部 :〒215-0033

神奈川県川崎市麻生区栗木2丁目3番12号

TEL 044-981-0560 FAX 044-981-0561

E-mail ejozndsn1@ejk.co.jp

取扱店:

advertisement

Key Features

  • Ozone generation up to 3.0 g/h
  • Adjustable ozone concentration
  • External control signal input (4~20 mA)
  • Constant temperature control for stable ozone generation
  • Compact design
  • Easy operation and maintenance
  • Safety features for ozone gas handling
  • Detailed instruction manual for safe and efficient operation

Frequently Answers and Questions

What are the requirements for installing the ozone generator?
The OZSD-3000A should be installed on a level surface, away from water, dust, corrosive gases, high temperatures, high humidity, strong vibration, direct sunlight, strong magnetic and electric fields, and high-frequency sources. Ensure sufficient space for maintenance and inspection. A no-fuse breaker should be installed on the power line outdoors for safety.
How do I connect the piping joints?
The manual provides detailed instructions for connecting both stainless steel and Teflon (PTFE) joints. Be sure to follow the steps carefully and check for leaks after connecting.
What are the safety precautions I need to take when using the ozone generator?
Ozone gas is harmful to human health, so it is crucial to follow all safety precautions listed in the manual. These include proper ventilation, prohibiting the use of fire in the same room as the generator, and having a designated administrator to manage the generator and control ozone gas usage.

Related manuals

Download PDF

advertisement