CONNECTING THE SYSTEM
FmX integrated display
Ag25 GNSS antenna
Basic power cable
(P/N 68040-OOS)
(P/N 67258)
Power bus (P/N 67259)
TNC/TNC right-angle cable
(P/N 50449)
FmX power cable
(P/N 566694)
Cable assembly, display to
Field-IQ (P/N 50449)
Remote foot switch
(optional) (P/N 60490)
Connect to port A or B only.
Field-IQ master switch box (P/N 75050-01)
12-section switch box (optional) (P/N 75060-01)
Cable assembly, CAN, cab to hitch
(P/N 77368)
IBRC to DPT adaptor cable
(optional) (P/N 77413)
Cable assembly, power to cab
(P/N 76941)
FmX power bus
(P/N 67259)
Note: For more information on system calibration and settings, see the Field-IQ chapter in the FmX Integrated Display User Guide.
Field-IQ Master Switch Box
c
d
e
f
Field-IQ 12-section Switch Box (optional)
c
g
d
e
Switch
Positions
Item
c LED indicator
Rate 1, Rate 2, Manual
e Space to write which row the switch controls.
c Increment/decrement
d Rate
e LED indicator
f Automatic/Manual section
control
g Master
Master Switch
setting
Automatic
Switch from Automatic to Manual mode while
travelling.
Off, On, Jump Start. Use the Jump Start function if you
lose the GPS signal or if you want to start applying
before the implement is up to speed.
Manual
1
d Section switches
12-section switch
position
Up / On
Down / Off
Up / On
Down / Off
Then ...
Section controlled by display.
Section off.
Section turned on.
Section off.
Operating in the field
Run screen
c
d
e
f
g
h
i
j
Item
Description
c
Field-IQ Plugin tab
d
Tank/Bin button
Shows capacity, warning level, current volume, and the Refill Tank/Bin and Manual Flush button.
e
Gate Height button
On the Spinner Spreading Run screen the Gate opening button sets the current value of the gate opening.
f
Implement Switch Status
Green arrow down – The implement is lowered.
Red arrow up – The implement is raised.
g
Increase/Decrease buttons
Increases and decreases the application rate by the amount specified during setup.
h
Logging button
Green – Logging enabled.
Gray – Logging disabled.
i
Engage button
Green – Auto guidance engaged.
Gray – Auto guidance can be engaged.
Red – Auto guidance cannot be engaged.
j
Field-IQ Status tab
Shows the engage status of each row on the implement.
Green – Engaged.
Gray – Section closed due to overlap.
Red – Not engaged / Section manually turned off.
2
Setting up the field-iq plugin
Before starting
Features tab
Before configuring the Field-IQ plugin setup on the FmX integrated
display, ensure that:
• All components of the system are installed on the vehicle and
implement.
• The Field-IQ plugin has been added to the FmX integrated
display configuration.
From the Home screen, tap the Run icon.
Next to Implement, tap Edit. The Configuration screen appears.
Ensure that the Field-IQ icon appears in the list.
If the icon does not appear tap Add/Remove to add the plugin
to the configuration.
• The implement setup has the correct option selected.
From the Home screen, tap the Run icon.
Next to Implement, tap Edit. The Configuration screen appears.
Select the implement from the list on the left and then tap
Setup. The Implement Setup screen appears.
In the Operations tab, select the correct option:
–– For Liquid, select the Liquid option.
–– For Granular Fertilizer, select the Granular Fertilizer option.
–– For Anhydrous, select the Anhydrous option.
Tap OK.
Note: For additional information on settings, select the help icon
in the top right hand corner of the screen.
Select the following:
1. Application Type.
2. Section Switching:
On: Automatic Section Control is active.
Off: Automatic Section Control is not active.
3. Rate Control:
On: Rate Control is active.
Off: Rate Control is not active.
4. Implement Lift:
Enabled: Implement switch controls coverage logging.
Disabled: Implement switch is not used.
5. Anhydrous Units:
When Anhydrous is selected for the application type, select the
units that you want to control the rate by. Select either Lbs
Actual N or Lbs NH3.
Boom tab
1. Section Control Type:
Air Clutch: Using Tru Count Air Clutches® valves.
Electric Clutch: Using Tru Count electric section clutches.
Boom Valve: Using standard polarity boom valves.
Reverse Polarity: Using reverse polarity boom valves.
Caution – Selecting the incorrect value causes the system
to operate opposite of the required result.
2. Sections Off When Stopped:
Yes: Turns off sections when the GPS speed is zero
(recommended).
No: Sections remian active when the GPS speed is zero.
3. On Latency:
Default value is 0.0 seconds. Increase the On Latency value to
compensate for mechanical delay in the system (more common
for larger systems).
4. Off Latency:
Default value is 0.0 seconds. Increase the Off Latency value to
compensate for mechanical delay in the system (more common
for larger systems).
3
Rate tab
Hardware tab
The Rate tab is only visible if you have at least one Field-IQ Rate
and Section Control Module installed.
1. Rate 1 and Rate 2 fields:
Enter the rate to be used when the Rate Switch on the Field-IQ
Master Switch box is in the Rate 1 or Rate 2 position.
2. Rate Adjust field:
Increment to be used each time you press the Increment/
Decrement switch on the Master Switch Box or display.
3. Rate Snapping list:
Enabled: Shows the applied rate the same as the target rate (if
the applied rate is within 10% of the target rate).
Disabled: Shows the actual applied value.
4. Total Nozzles:
Enter the total number of nozzles on the applicator (do not
include fence row nozzles).
Note – The numbers beneath each switch are the number of
sections assigned to the switch. In this example, switch 1 controls
rows 1 through 2, switch 2 controls rows 3 through 4, and so on.
The numbers are assigned automatically and cannot be changed.
If you are use the optional 12 section switch box, you will see 12
instead of 6 switches.
1. Adjust the width value for each rate control module by tapping
the Width box and entering the appropriate value.
2. To adjust the sections value for each section control module, tap
the Sections box. Enter the appropriate value and then tap OK.
3. Verify that the serial numbers of the modules match the order
that the modules are mounted on the implement.
Tank/Bin tab
The Tank/Bin tab is only visible if at least one Field-IQ Rawson™ or
Rate and Section control module is installed. Select the following:
1. Tank/Bin Capacity:
Total tank/bin capacity.
2. Warning Level:
Level at which you will receive notification when the capacity
level drops below the assigned value.
3. Current Volume:
Current volume of the tank/bin.
Tips
–– Tap Refill Tank/Bin to set the current volume to the tank/
bin capacity.
–– Tap Manual Flush to open the control valve and allow the
system to operate at a preset speed. Use this feature to
flush the booms or prime the system.
Sections tab
1. Enter the number of rows controlled for each section.
2. If the implement has more than 12 sections, use the buttons
below the 12 section fields to scroll to the other sections.
Override tab
1. Jump Start Speed:
Controls the speed to be used when the Master switch is put
in the jump start position.
2. Minimum Override Speed:
This setting maintains the application rate when the actual
speed drops below the value entered. It is used to ensure
consistent material flow during slow speeds that may reach the
physical limitations of the system.
4
Calibrating the Granular or liquid system
Granular and Liquid Calibration
Select Gate Height Calibration
1. If there is a Gate Height sensor connected to the Field-IQ
system, select Yes in the Enabled menu, then select Run
Calibration.
2. Follow the on-screen instructions to complete the calibration.
warning – there are Moving parts during this operation.
Ensure that the implement is safe to operate.
The Field-IQ Calibrate option only appears on the Configuration
screen if you have at least one Field-IQ Rate and Section Control
Module installed.
1. From the Configuration screen, select the Field-IQ plugin and
then press Calibrate.
2. From the Field-IQ Calibration screen, select the Rate and Section
Control Module to be calibrated.
3. Select Valve Calibration.
4. Select Valve Type, Plumbing, Valve Behavior on Sections Closed,
Auxiliary Valve, and Pump Disarming Switch.
5. Select the Control tab.
6. Adjust the Allowable Error, Gain, and Minimum Response for
optimal system performance.
Liquid Calibration
Select Flow Calibration
1. Set the Flow Meter Type, Flow Meter Calibration, and Minimum
Flow values.
2. Press Run Calibration.
3. Set the Target Rate and Speed and then press Next.
4. Follow the on-screen instructions to complete the calibration.
Select Pressure Calibration
1. Select the pressure sensor to be calibrated and enable it.
2. Enter the appropriate name and then press Run Calibration.
3. Follow the on-screen instructions to complete the calibration.
4. Repeat Step 1 through Step 3 for the second pressure sensor if
one is connected.
Granular System Calibration
Select Flow Calibration
1. In the Calibrate tab, enter the Gate Height setting and the
Shaft Encoder constant.
2. Press Calculate and then enter the Gate Width and Drag Chain
Distance traveled per Rev.
3. Select the Limit tab to set the maximum and minimum RPM.
4. Select the Info tab to verify the speeds that the system is
capable of reaching.
5. Return to the Calibrate tab and press Calibrate.
6. Enter the Amount of material you want to disperse, the Target
Rate, and Target Speed and then press Start.
7. Run the calibration and then enter the actual amount of
material dispensed.
Configuring the OEM switch interface
1. From the Configuration screen, highlight the OEM Switch
Interface and then select Setup.
2. Activate the switch on the OEM console that you want to
configure. This highlights the input on the left side of the
screen that the switch is connected to.
3. From the right-hand side of the screen, select the action to
assign to the switch.
4. Repeat Step 1 through Step 3 for all switches to be assigned.
5
with the Field-IQ™ Crop Input Control System
Quick Reference Card
Calibrating the rawson modules
Planter calibration
The Field-IQ Calibrate option only appears on the Configuration
screen if you have at least one Field-IQ Rawson control module
installed.
1. From the Configuration screen, select the Field-IQ plugin and
then tap Calibrate.
2. From the Field-IQ Calibration screen, select the Rawson Control
Module to be calibrated.
3. In the Seeds Per Disk field, enter a value.
4. Enter a value in the Gear Ratio field or tap Calculate.
5. Use the Gear Ratio Calculator to determine the planter drive
gear ratio and then tap OK. The Calibration Constant field
contains a calculated value that the system determines during
calibration. To start out, Trimble recommends that you leave
the value at 1.000. After the calibration test, the system may
adjust this number.
6. Place a clean empty container under the rows that contain
seeds to capture the seeds dispensed during the calibration.
warning – Moving parts during this operation. Ensure
that the implement is safe to operate.
*93020-88-E03*
7. Tap Test.
8. In the Number of Seed Meter Revolutions field, enter a value
and then tap Start. The higher the number of revolutions the
more accurate the calibration. Trimble recommends 5 to 10
revolutions.
9. Follow the on-screen prompts of operating the master switch.
After the system turns the specified number of revolutions,
enter the number of seeds dispensed per row and then tap
Continue.
10.The next screen shows the minimum and maximum speeds for
the target rate specified. Tap OK and then either press Test to
repeat the calibration or tap OK to continue.
11.Tap OK.
Repeat Step 1 through Step 9 for other Rawson Control Modules
that need calibration.
© 2010. Trimble Navigation Limited. All rights reserved. Trimble, the Globe and Triangle logo, AgGPS, FmX, and Tru Count Air Clutch
are trademarks of Trimble Navigation Limited, registered in the United States and in other countries. Field-IQ is a trademark of Trimble
Navigation Limited. Version 3.00, Rev C (September 2010).
P/N 93020-88-E03
6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising